Estimation and Reduction of Motor Input Surge Voltage Using Frequency Response Analysis
Authors:Toru Wakimoto  Yoshimitsu Takahashi  Norihito Kimura  Yukitoshi Narumi  Naoki Hayakawa
Affiliation:1. Nippon Soken Inc., Japan;2. DENSO Corp., Japan;3. Nagoya University, Japan
Abstract:This paper presents a plain method of calculating the voltage waveform at motor input terminals from the inverter output terminal voltage and also a method of reducing the voltage. The voltage waveform at the motor input terminals is obtained by a frequency domain calculation using the transfer function of the cable and the frequency characteristics of the voltage waveform at the inverter output terminals. The analysis using this method clarifies the mechanism of the rise of the maximum voltage at the motor input terminals, that is, ringing at the motor input terminals, which occurs at specific frequencies at which the transfer gain increases, causing the rise of the maximum voltage. Therefore, to decrease the maximum voltage at the motor input terminals, it is effective to shorten the cable length or cancel the ringing voltage by preswitching. © 2013 Wiley Periodicals, Inc. Electr Eng Jpn, 186(4): 11–19, 2014; Published online in Wiley Online Library ( wileyonlinelibrary.com ). DOI 10.1002/eej.22482
Keywords:inverter  cable  surge voltage  frequency response  fast Fourier transform