摘    要:为了减小转台误差对激光陀螺捷联惯组(SIMU)标定精度的影响,采用模观测法设计了正二十面体-12点的位置和速率试验计划。首先,利用在重力场下的12个静态位置标定加速度计的零偏、标度因子和安装误差矩阵;然后,采用外环角速率、中内环双轴翻滚至12点位置来标定陀螺的零偏、标度因子和安装误差矩阵;最后,利用SIMU框架坐标系为桥梁,实现了加速度计和陀螺参数坐标系的统一。仿真分析表明:该方法能有效抑制转台误差对SIMU标定结果的影响,当转台各轴系垂直度误差为角秒级且角位置误差小于1'时,加速度计和陀螺的标度因子相对误差和安装误差矩阵的标定误差均小于10-5,加速度计零偏的标定误差小于10g ,陀螺零偏的标定误差小于0.01()/h与测量噪声处于同一数量级。

关 键 词:模观测    激光陀螺    加速度计    标定    三轴转台
收稿时间:2018-04-13

Calibration method for the laser gyro strapdown inertial navigation system based on norm-observation
Affiliation:1.Space Control and Inertial Technology Research Center,Harbin Institute of Technology,Harbin 150001,China
Abstract:In order to reduce the influence of turntable's errors on the calibration accuracy of SIMU, the position and the rate test plans of the regular icosahedrons-12 points were designed by using norm observation of the specific force and the angular velocity vectors. Firstly, the twelve static positions were utilized to calibrate the accelerometers' biases, scale factors and mounting errors in the gravity field. Secondly, using single-axis rate and double-axis position mode, namely the outer axis of the three-axis turntable was working in angular rate mode, both the inner and the middle axes were in the twelve positions, the RLGs' biases, scale factors and mounting errors were calibrated. At the same time, unification of the accelerometer and the gyro parameter coordinate systems was realized by using the SIMU frame coordinate system. Finally, simulation analysis shows that this method can effectively suppress the influence of turntable's errors on the calibration results of SIMU, the relative calibration errors of the scale factors of the accelerometers' and the gyros', and the calibration errors of the installation error matrix are less than 10-5, the calibration errors of accelerometer biases are less than 10g, the calibration errors of gyro biases are less than 0.01()/h which are in the same order of magnitude of the measurement noises, in the situation that perpendicularities between the turntable's adjacent axis lines are at the arc second level and that angular position errors are less than 1'.
Keywords:
点击此处可从《红外与激光工程》浏览原始摘要信息
点击此处可从《红外与激光工程》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号