首页 | 本学科首页   官方微博 | 高级检索  
     


Cyclic fracture behaviour of 20MnMoNi55 steel at room and elevated temperatures
Authors:T. Chowdhury  S. Sivaprasad  H. N. Bar  S. Tarafder  N. R. Bandyopadhyay
Affiliation:1. Submersibles & Gas Hydrates, National Institute of Ocean Technology, Chennai, India;2. Fatigue & Fracture Group, Materials Science and Technology Division, CSIR‐National Metallurgical Laboratory, Jamshedpur, India;3. School of Materials Science and Engineering, Indian Institute of Engineering, Science and Technology, Shibpur, Howrah, India
Abstract:Cyclic fracture behaviour of 20MnMoNi55 steel has been evaluated at room temperature and elevated temperature of 300 °C. Fracture resistance at elevated temperature was found to be lower than that at room temperature. The deterioration in fracture resistance was due to dynamic strain ageing. Cyclic loading amplitude and frequency were also found to have an influence on fracture resistance. The features of the stretch zone during cyclic fracture were different from those at monotonic fracture. Stretch zone dimensions were found to be insensitive to cyclic load amplitudes whereas marginally affected by frequency of load cycles under dynamic strain ageing conditions.
Keywords:cyclic fracture  R ratio  incremental plastic displacement  stretch zone width  elevated temperature
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号