首页 | 官方网站   微博 | 高级检索  
     

永磁同步风电机组发电机定子温度建模方法
引用本文:杨明岱,王宪,赵前程,胡芳,阳雪兵.永磁同步风电机组发电机定子温度建模方法[J].太阳能学报,2022,43(5):319-326.
作者姓名:杨明岱  王宪  赵前程  胡芳  阳雪兵
作者单位:1.湖南科技大学 风电机组运行数据挖掘与利用技术湖南省工程研究中心,湘潭 411201; 2.湘电风能有限公司,湘潭 411000
基金项目:国家自然科学基金(51875199);;国家重点研发计划(2016YFF0203400);;湖南省重点研发计划(2018GK2073);
摘    要:针对山地风电场大型永磁同步风电机组发电机定子温度的变化特点及传热过程进行分析,提出一种基于风电机组SCADA数据的发电机定子温度建模方法。首先,分析风电机组在实际运行过程中定子温度的变化情况;然后,根据永磁同步发电机内部的传热过程,对发电机定子温度建模;最后,采用风电机组正常运行时的SCADA数据求解模型参数。实例分析表明,风电机组状态正常时,定子温度估计的平均误差绝对值为0.59 ℃,模型精度较高;风电机组状态异常时,模型温度估计的平均误差绝对值为5.17 ℃,精度显著降低。

关 键 词:风力发电  风电机组  定子  永磁同步发电机  温度数据分析  状态监测  
收稿时间:2020-08-31

MODELING METHOD OF STATOR TEMPERATURE OF PMSG WIND TURBINE
Yang Mingdai,Wang Xian,Zhao Qiancheng,Hu Fang,Yang Xuebing.MODELING METHOD OF STATOR TEMPERATURE OF PMSG WIND TURBINE[J].Acta Energiae Solaris Sinica,2022,43(5):319-326.
Authors:Yang Mingdai  Wang Xian  Zhao Qiancheng  Hu Fang  Yang Xuebing
Affiliation:1. Engineering Research Center of Hu’nan Province for the Mining and Utilization of Wind Turbines Operation Data, Hunan University of Science and Technology, Xiangtan 411201, China; 2. XEMC Windpower Co., Ltd., Xiangtan 411000, China
Abstract:By analyzing the temperature change characteristics and heat transfer process of the generator stator of large permanent magnet synchronous generator (PMSG) in mountain wind farm, a wind turbine SCADA data-based generator stator temperature modeling method was proposed in this paper. Firstly, the change of stator temperature in the operating process of wind turbine was analyzed and then the generator stator temperature was modeled according to the heat transfer process in PMSG; Finally, the model parameters were solved by using SCADA data of wind turbine in normal operation. According to the instance analysis results, the average error absolute of temperature estimation of the model is 0.59 ℃ and the model is highly accurate when the wind turbine is in normal state; when the wind turbine state is abnormal, the average error absolute of the model temperature estimation is 5.17 ℃, and the accuracy is significantly reduced. The model can be used for wind turbine state assessment.
Keywords:wind power  wind turbines  stators  PMSG  temperature data analysis  status report  
点击此处可从《太阳能学报》浏览原始摘要信息
点击此处可从《太阳能学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23