相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper investigated the transmission of respiratory droplets between two seated occupants equipped with one type of personalized ventilation (PV) device using round movable panel (RMP) in an office room. The office was ventilated by three different total volume (TV) ventilation strategies, i.e. mixing ventilation (MV), displacement ventilation (DV), and under-floor air distribution (UFAD) system respectively as background ventilation methods. Concentrations of particles with aerodynamic diameters of 0.8 μm, 5 μm, and 16 μm as well as tracer gas were numerically studied in the Eulerian frame. Two indexes, i.e. intake fraction (IF) and concentration uniformity index RC were introduced to evaluate the performance of ventilation systems. It was found that without PV, DV performed best concern protecting the exposed manikin from the pollutants exhaled by the polluting manikin. In MV when the exposed manikin opened RMP the inhaled air quality could always be improved. In DV and UFAD application of RMP might sometimes, depending on the personalized airflow rate, increase the exposure of the others to the exhaled droplets of tracer gas, 0.8 μm particles, and 5 μm particles from the infected occupants. Application of PV could reduce RC for all the three TV systems of 0.8 μm and 5 μm particles. PV enhanced mixing degree of particles under DV and UFAD based conditions much stronger than under MV based ones. PV could increase the average concentration in the occupied zone of the exposed manikin as well as provide clean personalized airflow. Whether inhaled air quality could be improved depended on the balance of pros and cons of PV.  相似文献   

2.
This paper adopts an Eulerian-Lagrangian approach to investigate the lock-up phenomenon (or trap phenomenon) of human exhaled droplets in a typical office room under displacement ventilation (DV). A particle-source-in-cell (PSI-C) scheme is used to correlate the concentration with the Lagrangian particle trajectories in computational cells. Respiratory droplets with sizes of 0.8 μm, 5 μm and 16 μm are released from a numerical thermal manikin (NTM). The influence factors including indoor temperature gradient, heat source configuration and exhalation modes are studied. It is found that large temperature gradient would result in trap phenomenon of small exhaled droplets (smaller than 5 μm). The intensive heat source near the NTM could help to transport the small droplets to the upper zone and decrease the concentration level in the trapped zone. Both nose-exhaled and mouth-exhaled small droplets would be trapped at the breathing height when temperature gradient is sufficiently high. However, the trap height of the droplets from mouth is a little bit higher. Because of large gravitational force, it is difficult for the thermal plume to carry 16 μm respiratory droplets to the upper zone.  相似文献   

3.
A computer model for predicting aerosol dispersion in indoor spaces was validated with experimental data found in the literature. The validated model was used to explore the effect of the area or point source locations on aerosol particle transportation in ventilation rooms with rough surfaces. Two different ventilation strategies were studied: mixing ventilation (MV) and underfloor air distribution (UFAD) system. The simulation results show that in MV, the particle concentration and removal effectiveness are little dependent on the position of the pollutant sources. In UFAD, the source location has a strong impact on the distribution and removing of the contaminants. The particle removal performance strongly depends on the ventilation efficiency and the particle deposition loss in the room with rough surfaces. The important consideration in both the relative ventilation efficiency and the deposition rate is the relative position of the sources to the main airflow and the occupied zone in an UFAD room.  相似文献   

4.
The risk of cross‐infection is high when the susceptible persons are exposed to the pathogen‐laden droplets or droplet nuclei exhaled by infectors. This study proposes a jet integral model to predict the dispersion of exhaled contaminants, evaluating the exposure risk and determining a threshold distance to identify the direct and indirect exposures in both thermally uniform and stratified environments. The results show that the maximum concentration of contaminants exhaled by a bed‐lying infector clearly decreases in a short distance (<1.8 m) in a uniform environment, while it maintains high values in a long distance in a stratified environment. The lock‐up phenomenon largely weakens the decay of the concentration. The direct exposure of the receiver is determined primarily by the impact scope of the exhaled airflow, while the indirect exposure is mainly related to the ventilation rate and air distribution in the room. In particular, the distance of direct exposure is the longest (approximately 2 m) when the receiver's breathing height is at the lock‐up layer in a stratified environment. Our study could be useful for developing effective prevention measures to control cross‐infection in the initial stage of design of indoor layouts and ventilation systems.  相似文献   

5.
Y. Cheng  Z. Lin 《Indoor air》2015,25(6):662-671
The motivation of this study is stimulated by a lack of knowledge about the difference of airflow characteristics between a novel air distribution method [i.e., stratum ventilation (SV)] and conventional air distribution methods [i.e., mixing ventilation (MV) and displacement ventilation (DV)]. Detailed air velocity and temperature measurements were conducted in the occupied zone of a classroom with dimensions of 8.8 m (L) × 6.1 m (W) × 2.4 m (H). Turbulence intensity and power spectrum of velocity fluctuation were calculated using the measured data. Thermal comfort and cooling efficiency were also compared. The results show that in the occupied zone, the airflow characteristics among MV, DV, and SV are different. The turbulent airflow fluctuation is enhanced in this classroom with multiple thermal manikins due to thermal buoyancy and airflow mixing effect. Thermal comfort evaluations indicate that in comparison with MV and DV, a higher supply air temperature should be adopted for SV to achieve general thermal comfort with low draft risk. Comparison of the mean air temperatures in the occupied zone reveals that SV is of highest cooling efficiency, followed by DV and then MV.  相似文献   

6.
The main objective of this study was to examine the performance of protected zone ventilation (PZV) and hybrid protected zone ventilation (HPZV) to reduce the direct exposure to exhaled air from others' breathing. Experimental measurements are carried out to test the performance of PZV in a full‐scale office room with two breathing thermal manikins. The measurements were performed under three configurations, including two standing manikins at different distances: 0.35, 0.5, and 1.1 m. When the supply air velocity is increased to 4 m/s in the downward plane jet, the dimensionless concentration is 40% lower than for fully mixed ventilation, which can be considered as a measure of protection from the zoning condition. The measurement results showed that in both the PZV and the HPZV system it is possible to decrease the transmission of tracer gas from one manikin to the opposite manikin; therefore, it probably would reduce the risk of air borne cross‐infection between two people at the same relative positions. The results suggest that PZV and HPZV may be used to reduce the exposure of people in a protected zone from indoor pollutants emitted in a source zone.  相似文献   

7.
X. Li  J. Niu  N. Gao 《Indoor air》2013,23(2):162-171
Personalized ventilation (PV) system in conjunction with total ventilation system can provide cleaner inhaled air for the user. Concerns still exist about whether the normally protecting PV device, on the other hand, facilitates the dispersion of infectious agents generated by its user. In this article, two types of PV systems with upward supplied fresh air, namely a chair‐based PV and one kind of desk‐mounted PV systems, when combined with mixing ventilation (MV) and displacement ventilation (DV) systems, are investigated using simulation method with regard to their impacts on co‐occupant's exposure to the exhaled droplet nuclei generated by the infected PV user. Simulation results of tracer gas and particles with aerodynamic diameter of 1, 5, and 10 μm from exhaled air show that, when only the infected person uses a PV, the different PV air supplying directions present very different impacts on the co‐occupant's intake under DV, while no apparent differences can be observed under MV. The findings demonstrate that better inhaled air quality can always be achieved under DV when the adopted PV system can deliver conditioned fresh air in the same direction with the mainly upward airflow patterns of DV.  相似文献   

8.
The study investigated the separate and combined effects of ventilation rate, free convection flow produced by a thermal manikin, and the presence of objects on the distribution of tracer gas and particles in indoor air. The concentration of aerosol particles and tracer gas was measured in a test room with mixing ventilation. Three layouts were arranged: an empty room, an office room with an occupant sitting in front of a table, and a single‐bed hospital room. The room occupant was simulated by a thermal manikin. Monodisperse particles of three sizes (0.07, 0.7, and 3.5 μm) and nitrous oxide tracer gas were generated simultaneously at the same location in the room. The particles and gas concentrations were measured in the bulk room air, in the breathing zone of the manikin, and in the exhaust air. Within the breathing zone of the sitting occupant, the tracer gas emerged as reliable predictor for the exposure to all different‐sized test particles. A change in the ventilation rate did not affect the difference in concentration distribution between tracer gas and larger particle sizes. Increasing the room surface area did not influence the similarity in the dispersion of the aerosol particles and the tracer gas.  相似文献   

9.
Bjørn E  Nielsen PV 《Indoor air》2002,12(3):147-164
The influence of the human exhalation on flow fields, contaminant distributions, and personal exposure in displacement ventilated rooms is studied together with the effects of physical movement. Experiments are conducted in full-scale test rooms with life-sized breathing thermal manikins. Numerical simulations support the experiments. Air exhaled through the mouth can lock in a thermally stratified layer, if the vertical temperature gradient in breathing zone height is sufficiently large. With exhalation through the nose, exhaled air flows to the upper part of the room. The exhalation flow from both nose and mouth is able to penetrate the breathing zone of another person standing nearby. The stratification of exhaled air breaks down if there is physical movement in the room. As movement increases, the concentration distribution in the room will move towards a fully mixed situation. The protective effect of the boundary layer flow around the body of a moving person disappears at low speed, and is reduced for a seated person placed nearby due to horizontal air movements, which can also cause rebreathing of exhaled air for the seated person. The results indicate that the effect of the exhalation flow is no acute problem in most normal ventilation applications. However, exhalation and local effects caused by movement may be worth considering if one wishes to contain contaminants in certain areas, as in the case of tobacco smoking, in hospitals and clinics, or in certain industries.  相似文献   

10.
The level of exposure to human exhaled contaminants in a room depends not only on the air distribution system but also on people's different positions, the distance between them, people's activity level and height, direction of exhalation, and the surrounding temperature and temperature gradient. Human exhalation is studied in detail for different distribution systems: displacement and mixing ventilation as well as a system without mechanical ventilation. Two thermal manikins breathing through the mouth are used to simulate the exposure to human exhaled contaminants. The position and distance between the manikins are changed to study the influence on the level of exposure. The results show that the air exhaled by a manikin flows a longer distance with a higher concentration in case of displacement ventilation than in the other two cases, indicating a significant exposure to the contaminants for one person positioned in front of another. However, in all three cases, the exhalation flow of the source penetrates the thermal plume, causing an increase in the concentration of contaminants in front of the target person. The results are significantly dependent on the distance and position between the two manikins in all three cases. PRACTICAL IMPLICATIONS: Indoor environments are susceptible to contaminant exposure, as contaminants can easily spread in the air. Human breathing is one of the most important biological contaminant sources, as the exhaled air can contain different pathogens such as viruses and bacteria. This paper addresses the human exhalation flow and its behavior in connection with different ventilation strategies, as well as the interaction between two people in a room. This is a key factor for studying the airborne infection risk when the room is occupied by several persons. The paper only takes into account the airborne part of the infection risk.  相似文献   

11.
The gaseous contaminant diffusion under stratum ventilation is investigated by numerical method which is validated by experiments carried out. The concentration of gaseous contaminants along the supply air jet is found to be lower than the other parts of the room. Compared with displacement ventilation, the formaldehyde concentration in breathing zone is lower when a contaminant source locates close to the occupant. The concentration is at the same level when the contaminant source locates up-steam to the occupant. The concentration in the occupied zone (<1.9 m from the floor) is also lower when the contaminant source locates on the floor. At supply air temperature optimized for displacement ventilation, the toluene concentration in breathing zone for stratum ventilation is higher than that for displacement ventilation when the area source locates on the four surrounding walls of the room.  相似文献   

12.
The inhalation intake fraction was used as an indicator to compare effects of desktop personalized ventilation and mixing ventilation on personal exposure to directly released simulated cough droplets. A cough machine was used to simulate cough release from the front, back, and side of a thermal manikin at distances between 1 and 4 m. Cough droplet concentration was measured with an aerosol spectrometer in the breathing zone of a thermal manikin. Particle image velocimetry was used to characterize the velocity field in the breathing zone. Desktop personalized ventilation substantially reduced the inhalation intake fraction compared to mixing ventilation for all investigated distances and orientations of the cough release. The results point out that the orientation between the cough source and the breathing zone of the exposed occupant is an important factor that substantially influences exposure. Exposure to cough droplets was reduced with increasing distance between cough source and exposed occupant.  相似文献   

13.
This study investigated contaminant transport and evaluated the ventilation performance in a single-bed inpatient room. The study performed comparative experimental analysis on the distributions of respiratory contaminants breathed out and coughed out by a patient in a full-scale chamber, which simulated a single-bed inpatient room. The contaminant exhaled by the patient was simulated by an SF6 tracer gas and 3-μm particles at steady-state conditions. The differences in the contaminant distribution between the coughing and breathing cases were insignificant for the mixing ventilation case, while for the displacement ventilation, the contaminant concentrations in the upper part of the room were higher for the coughing case. The contaminant concentrations in the inpatient room for the case with the patient sitting on the bed were lower than those for the patient supine on the bed for the displacement ventilation under the same supply airflow rate. The SF6 tracer gas and 3-μm particles released at a notable initial velocity for simulating a cough could give similar contaminant distributions in the inpatient room. Therefore, the experimental data can be used to validate a CFD model, and the validated CFD model can be used to investigate transient coughing and breathing processes.  相似文献   

14.
In this study, numerical prediction using computational fluid dynamics (CFD) was utilized to investigate air temperature stratification in a room with an underfloor air distribution (UFAD) system. The numerical modeling using CFD computation was validated with physical test in a full size experimental room with an UFAD system. The different supply air conditions and heat loads were discussed. The results show that the effect of three parameters, heat load, supply volume flux and supply air velocity, on room air temperature would be expressed by the length scale of the floor supply jet. When the length scale increased from 0.8 to 1.56 m, the ratio of vertical temperature difference between 2.5 and 0.1 m at the occupied zone to the difference between return and supply air temperature decreased from 0.62 to 0.25. When there was only one local heat source in the room, there was a thermal stratified interface at the occupied zone. The interface height was about 1.42 times the length scale. The results may suggest ways to optimize UFAD design and operation.  相似文献   

15.
Ventilation effectiveness is an indicator of the quality of supply air distribution in ventilated rooms. It is a representation of how well a considered space is ventilated compared to a perfect air mixing condition. Depending on pollutant properties and source position relative to the airflow, ventilation effectiveness can more or less successfully be used as an indicator of air quality and human exposure. This paper presents an experimentally and numerically based study that examines the relationship between ventilation effectiveness and particle concentration in typical indoor environments. The results show that the relationship varies predominantly with airflow pattern and particle properties. Fine particles (1 μm) follow the airflow pattern more strictly than coarse particles (7 μm), and the high ventilation effectiveness indicates better removal of fine particles than coarse particles. When a ventilation system provides high mixing in the space and ventilation effectiveness is close to one, particle sizes and source location have a relatively small effect on particle concentration in the breathing zone. However, when the supply air is short circuited and large stagnation zones exist within the space, the particle concentration in the breathing zone varies with particle size, source location, and airflow pattern. Generally, the results show that for fine particles (1 μm), increase of ventilation effectiveness reduces occupant exposure; while for coarser particles (7 μm), source location and airflow around the pollutant source are the major variables that affect human exposure.  相似文献   

16.
Many airborne infectious diseases can be transmitted via exhaled contaminants transported in the air. Direct exposure occurs when the exhaled jet from the infected person directly enters the breathing zone of the target person. Indirect exposure occurs when the contaminants disperse in the room and are inhaled by the target person. This paper presents a simple method for differentiating the direct and indirect exposure to exhaled contaminants in mechanically ventilated rooms. Experimental data for 191 cases were collected from the literature. After analyzing the data, a simple method was developed to differentiate direct and indirect exposure in mixing and displacement ventilated rooms. The proposed method correctly differentiated direct and indirect exposure for 120 out of the 133 mixing ventilation cases and 47 out of the 58 displacement ventilation cases. Therefore, the proposed method is suitable for use at the early design stage to quickly assess whether there will be direct exposure to exhaled contaminants in a mechanically ventilated room.  相似文献   

17.
The importance of the intake positioning height above the floor level on the performance of “ductless” personalized ventilation (“ductless” PV) in conjunction with displacement ventilation (DV) was examined with regard to the quality of inhaled air and of the thermal comfort provided. A typical office room with two workstations positioned one behind the other was arranged in a full-scale room. Each workstation consisted of a table with an installed “ductless” PV system, PC, desk lamp and seated breathing thermal manikin. The “ductless” PV system sucked the clean and cool displacement air supplied over the floor at four different heights, i.e. 2, 5, 10 and 20 cm and transported it direct to the breathing level. Moreover, two displacement airflow rates were used with a supply temperature adjusted in order to maintain an exhaust air temperature of 26 °C. Two pollution sources, namely air exhaled by one of the manikins and passive pollution on the table in front of the same manikin were simulated by constant dosing of tracer gases. The results show that the positioning of a “ductless” PV intake height up to 0.2 m above the floor will not significantly influence the quality of inhaled air and thermal comfort.  相似文献   

18.
基于地板送风与置换通风原理的相似性,参考办公室中置换通风的设计方法,结合旋流风口地板送风系统的特性,提出旋流风口地板送风系统的设计方法。通过实验对设计方法进行了验证,并对室内热舒适性进行了评价。  相似文献   

19.
The potential for improving occupants’ thermal comfort with personalized ventilation (PV) system combined with under-floor air distribution (UFAD) system was explored through human response study. The hypothesis was that cold draught at feet can be reduced when relatively warm air is supplied by UFAD system and uncomfortable sensation as “warm head” can be reduced by the PV system providing cool and fresh outdoor air at the facial level. A study with 30 human subjects was conducted in a Field Environmental Chamber. The chamber was served by two dedicated systems – a primary air handling unit (AHU) for 100% outdoor air that is supplied through the PV air terminal devices and a secondary AHU for 100% recirculated air that is supplied through UFAD outlets. Responses of the subjects to the PV-UFAD system were collected at various room air and PV air temperature combinations. The analyses of the results obtained reveal improved acceptability of perceived air quality and improved thermal sensation with PV-UFAD in comparison with the reference case of UFAD alone or mixing ventilation with ceiling supply diffuser. The local thermal sensation at the feet was also improved when warmer UFAD supply air temperature was adopted in the PV-UFAD system.  相似文献   

20.
地板送风与置换通风的差异   总被引:14,自引:2,他引:14  
探讨了地板送风和置换通风两种下送风方式在概念、机理、主要功能、特性及应用等诸多方面的差异与联系,分析比较了各自的优越性及局限性,提出了地板送风和置换通风各自的适用范围。地板送风作为一种节能空调系统应同时处理好通风换气和温度控制功能;置换通风由于加热和除湿问题,其应用在一定程度上受到了限制,但只要将其应用在恰到好处的场合,也可发挥出优势。  相似文献   