首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 562 毫秒
1.
Background/PurposeAlthough scleral contact lenses are prescribed with increasing frequency, little is known about their long-term effects on ocular physiology. The main goal of this paper is to predict values of oxygen transmissibility of scleral lens systems by applying the concept of resistors in series to parameters characteristic of current scleral lenses. A second aim is to find the maximal lens and post-lens tear layer thickness combinations above which hypoxia-induced corneal swelling would be found.MethodsTheoretical calculations were used to predict the oxygen transmissibility of scleral lens systems, considering several material permeabilities (Dks 100–170), varying lens thicknesses (250–500 μm), the known tear permeability (Dk of 80) and expected post-lens tear layer thicknesses (100–400 μm). The Holden–Mertz Dk/t criteria of 24 Fatt units for the central cornea and the Harvitt–Bonanno criteria of 35 Fatt units for the limbal area were used as reference points.ResultsOur calculations of oxygen transmissibility, with varying tear layer and lens thicknesses, ranged from 10 to 36.7 at the scleral lens centers and from 17.4 to 62.6 at the peripheries. Our calculations of maximum central lens thicknesses show a practical range of 250–495 μm, in conjunction with a post-lens tear layer thickness of 100–250 μm.ConclusionOur computations show that most modern scleral lenses, with recommended fitting techniques, should lead to some level of hypoxia-induced corneal swelling. Recommendations are made to minimize hypoxia-induced corneal swelling: highest Dk available (>150) lens with a maximal central thickness of 250 μm and fitted with a clearance that does not exceed 200 μm.  相似文献   

2.
3.
PurposeTo evaluate the success rate of highly gas permeable scleral contact lenses (SCL) for visual rehabilitation after penetrating keratoplasty (PK), over a period of up to 9 years.MethodsA total database of 31 consecutive patient fitted with SCL between January 2004 and December 2009 was retrospectively reviewed. Demographic data, etiology prior to lens fitting, visual outcomes, follow up time and complications were analyzed.ResultsAll eyes were fitted due to inadequate spectacle-corrected vision after successful penetrating keratoplasty or failure of other contact lens modalities. Out of 31 patients fitted, 28 (33 eyes) continue to wear SCL for periods between 0.5 and 8.8 years. The mean duration of follow-up after contact lens fitting was 5.2 ± 2.2 years. The mean age of corneal graft was 17.6 ± 11.4 years (range 4.3–42), and the mean interval between PK and initial contact lens fitting was 12.2 ± 10.7 years (range 0.7–36.0). The average steepest keratometry of our cohort was 55.0 ± 7.5 diopter (D) and the refractive astigmatism was 8.0 ± 4.4 D. The mean contact lens corrected visual acuity (BCVAcl) was 0.78 ± 0.25 (range 0.3–1.2). Twenty-three (82%) patients achieved a functional vision of 0.5 or more.During the studied period, ten (30.0%) eyes presented at least one graft rejection episode and two eyes (6%) had an episode of microbial keratitis. Corneal transplants of 20 years or more show a higher rate of refits due to ectasia recurrence.ConclusionsScleral lenses should be considered as lens of choice in eyes with complex corneal geometry, as besides visual rehabilitation, their use may delay or prevent further surgical involvement.  相似文献   

4.
PurposeTo evaluate the refractive and corneal topographical changes of overnight orthokeratology in myopia with two brands of contact lenses.MethodsFourty-four eyes of 22 myopic patients with manifest refraction spherical equivalent (MRSE) of −1.00 to −5.00 D (cylinder  −1.0) were fitted with either DreamLens (Hanita Lenses Investments, Hanita, Israel) (group A) or Rinehart–Reeves (R&R; Danker Laboratories, Sarasota, FL) (group B) reverse-geometry lenses. Each subject eye was evaluated in regards to the uncorrected and corrected distance visual acuities, manifest refraction, slit lamp biomicroscopy, and corneal topography at each follow-up examination.ResultsThe follow-up was 1 year. For groups A and B, the mean uncorrected distance visual acuity was −0.02 ± 0.10 log MAR (20/20) and −0.08 ± 0.12 log MAR (20/20) respectively at year-1 examination. The mean MRSE decreased from −2.70 ± 0.9 D to −0.50 ± 0.08 D in group A and −3.1 ± 1.1 to −0.62 ± 0.18 D in group B at week-1; and remained stable thereafter in each group. For both groups, starting with week-1, the mean anterior best-fit sphere (ABFS) was statistically significantly flatter from baseline. A high correlation was found between the change in apical corneal power (ACP) and MRSE (r1 = 0.79, r2 = 0.71), and there was a good correlation between the change in ABFS and MRSE (r1 = 0.67, r2 = 0.64) in both groups. No significant ocular adverse events were observed during study.ConclusionsBoth types of contact lenses safely and effectively decreased the myopic refractive error at 1 year follow-up. The refractive effect was mainly induced by the changes in the anterior corneal shape and the ACP.  相似文献   

5.
PurposeThe aim of this cross-over study was to investigate the changes in corneal thickness, anterior and posterior corneal topography, corneal refractive power and ocular wavefront aberrations, following the short term use of rigid contact lenses.MethodFourteen participants wore 4 different types of contact lenses (RGP lenses of 9.5 mm and 10.5 mm diameter, and for comparison a PMMA lens of 9.5 mm diameter and a soft silicone hydrogel lens) on 4 different days for a period of 8 h on each day. Measures were collected before and after contact lens wear and additionally on a baseline day.ResultsAnterior corneal curvature generally showed a flattening with both of the RGP lenses and a steepening with the PMMA lens. A significant negative correlation was found between the change in corneal swelling and central and peripheral posterior corneal curvature (all p  0.001). RGP contact lenses caused a significant decrease in corneal refractive power (hyperopic shift) of approximately 0.5 D. The PMMA contact lenses caused the greatest corneal swelling in both the central (27.92 ± 15.49 μm, p < 0.001) and peripheral (17.78 ± 12.11 μm, p = 0.001) corneal regions, a significant flattening of the posterior cornea and an increase in ocular aberrations (all p  0.05).ConclusionThe corneal swelling associated with RGP lenses was relatively minor, but there was slight central corneal flattening and a clinically significant hyperopic change in corneal refractive power after the first day of lens wear. The PMMA contact lenses resulted in significant corneal swelling and reduced optical performance of the cornea.  相似文献   

6.
PurposeTo compare conventional method of contact lens fitting with software based contact lens fitting using Medmont corneal topographer in eyes with nebular and macular corneal scars.MethodsFifteen participants who were diagnosed with nebular and macular scars were fitted with rigid gas permeable lenses using conventional method of contact lens fitting. During the lens dispensing visit, participants underwent Medmont corneal topography. Agreement between the two methods of contact lens fitting was studied.ResultsParameters of contact lenses which were concluded using conventional method was compared to that of software based fitting. Mean difference in base curve of contact lens between the two methods was 0.094 mm ± 0.147 mm (95% CI: +0.383 to −0.194). Mean difference in diameter of contact lens between the two methods was 0.16 mm ± 0.172 mm (95% CI: +0.497 to −0.177). Contact lens parameters that were achieved using two different methods of fitting showed good correlation. Correlation coefficients, as comparison of two methods in base curve and diameter were 0.96 (P < 0.05) and 0.94 (P < 0.05), respectively.ConclusionSoftware based contact lens fitting would be useful for contact lens practitioners to predict initial base curve of contact lens in corneal scars.  相似文献   

7.
PurposeThis study compared the biocompatibility and comfort of 4 lens care solutions currently marketed in France.MethodsThis was a randomized, interventional, double-masked, single-center crossover study assessing balafilcon A silicone hydrogel contact lenses, bilaterally, straight from the blister pack solution (control) and pre-soaked in the following lens care solutions: Regard® (containing sodium chlorite), ReNu® (containing a PHMB [polyhexamethylene biguanide] derivative), CyClean™ and MeniCare™ Soft (both containing PHMB). Subjects were randomized to the order of test solution use. For each of the 5 solutions tested, subjects attended a baseline/lens dispensing visit and an intervention visit 2 h later. At both visits, evaluation included slit-lamp examination, corrected-distance visual acuity, corneal staining, and subject-assessed photophobia, ocular comfort, and ocular redness.ResultsThirty subjects were enrolled and 28 were evaluable. Corneal staining severity was significantly worse than baseline after 2 h of wearing lenses soaked in CyClean, MeniCare, or ReNu (P  0.001). The MeniCare group alone demonstrated a significant improvement in ocular comfort after 2 h of lens wear (P = 0.02). No group demonstrated significant changes in ocular redness or photophobia. Corrected-distance visual acuity was similar between baseline and intervention visits for each test solution. No adverse events were reported during the study.ConclusionsSilicone hydrogel contact lenses presoaked in lens solutions containing PHMB or a PHMB derivative produced an increase in corneal staining after 2 h of lens wear. The higher levels of corneal staining in the 2 solutions did not correlate with increased discomfort within this 2-h timeframe.  相似文献   

8.
PurposeTo examine the influence of short-term miniscleral contact lens wear on corneal shape, thickness and anterior surface aberrations.MethodsScheimpflug imaging was captured before, immediately following and 3 h after a short period (3 h) of miniscleral contact lens wear for 10 young (mean 27 ± 5 years), healthy participants. Natural diurnal variations were considered by measuring baseline diurnal changes obtained on a separate control day without contact lens wear.ResultsSmall but significant anterior corneal flattening was observed immediately following lens removal (overall mean 0.02 ± 0.03 mm, p < 0.001) which returned to baseline levels 3 h after lens removal. During the 3 h recovery period significant corneal thinning (−13.4 ± 10.5 μm) and posterior surface flattening (0.03 ± 0.02 mm) were also observed (both p < 0.01). The magnitude of posterior corneal flattening during recovery correlated with the amount of corneal thinning (r = 0.69, p = 0.03). Central corneal clearance (maximum tear reservoir depth) was not associated with corneal swelling following lens removal (r = −0.24, p > 0.05). An increase in lower-order corneal astigmatism Z(2,2) was also observed following lens wear (mean −0.144 ± 0.075 μm, p = 0.02).ConclusionsFlattening of the anterior corneal surface was observed immediately following lens wear, while ‘rebound’ thinning and flattening of the posterior surface was evident following the recovery period. Modern miniscleral contact lenses that vault the cornea may slightly influence corneal shape and power but do not induce clinically significant corneal oedema during short-term wear.  相似文献   

9.
PurposeTo evaluate the impact of differente soft contact lens power in the anterior corneal curvature and regularity in subjects with keratoconus.MethodsNineteen subjects (30 eyes) with keratoconus were included in the study. Six corneal topographies were taken with Pentacam Eye System over the naked eye and successively with soft lens (Senofilcon A) powers of −3.00, −1.50, 0.00, +1.50 and +3.00 D. Corneal measurements of mean central keratometry (MCK), maximum tangential curvature (TK), maximum front elevation (MFE) and eccentricity (Ecc) at 6 and 8 mm diameters as well as anterior corneal surface high order aberrations (i.e. total RMS, spherical- and coma-like and secondary astigmatism) were evaluated.ResultsNegative- and plano-powered soft lenses flattened (p < 0.05 in all cases), whereas positive-powered lenses did not induce any significant changes (p > 0.05 in all cases) in MCK in comparison to the naked eye. The TK power decreased with negative lenses (p < 0.05 in both cases) and increased with +3.00 D lenses (p = 0.03) in comparison to the naked eye. No statistically significant differences were found in MFE with any soft lens power in comparison to the naked eye (p > 0.05 in all cases). Corneal eccentricity increased at 8 mm diameter for all lens powers (p < 0.05 in all cases). No statistically differences were found in HOA RMS and spherical-like aberration (both p > 0.05). Statistically differences were found in coma-like and secondary astigmatism (both p < 0.05).ConclusionNegative-powered soft contact lenses provide a flatter anterior surface in comparison to positive-powered lenses in subjects with keratoconus and thus they might be more suitable for piggyback contact lens fitting.  相似文献   

10.
PurposeTo investigate the efficacy and safety of a fenestrated and channelled soft contact lens (F-SCL) compared to a standard and non-fenestrated soft contact lens (S-SCL) in experienced soft contact lens (SCL) wearers.MethodsThis was a randomised, crossover, single-blinded (subject), and multicentre clinical trial. Sixteen experienced SCL wearers were randomly divided into two groups (FS and SF). The FS group first wore F-SCLs followed by S-SCLs, each for 10 days, separated by a 1-week washout period, whereas the SF group wore the S-SCLs first and crossed over to F-SCLs in the same manner. The F-SCLs were designed with three equally spaced, symmetrical fenestrations and a partial-thickness, connecting, circumferential channel on the back surface of the mid-periphery of the lens. Measurement of central corneal thickness using ultrasonic pachymetry was performed on the day of screening, after the 1-week washout period, and after 10 days of wearing each kind of lens, based on which central corneal swelling was calculated and compared. One eye in each subject was chosen at random for analysis.ResultsCentral corneal swelling was 1.92 ± 1.73% vs. 5.26 ± 2.14% in F-SCLs vs. S-SCLs wearers, which was statistically significant (P < 0.001). There was no significant difference between the groups in terms of SCL-corrected visual acuity or SCL-related adverse events.ConclusionThe use of F-SCLs led to reduced corneal swelling compared to S-SCLs. The newly incorporated features appear to improve tear mixing and thereby the oxygen supply to the cornea, which results in reduced corneal oedema.  相似文献   

11.
PurposeThe aim of the present study was to compare the objective and subjective visual performance of three different soft multifocal contact lenses.Methods10 subjects (habitual soft contact lens wearers) between the ages of 40 and 45 years participated in the study. Three different multifocal silicone hydrogel contact lenses (Acuvue Oasys, Air Optix and Biofinity) were fit within the same visit. All the lenses were fit according to the manufacturers’ recommendation using the respective fitting guide. Visual performance tests included low and high contrast distance and near visual acuity, contrast sensitivity, range of clear vision and through-focus curve. Objective visual performance tests included measurement of open field accommodative response at different defocus levels and optical aberrations at different viewing distances.ResultsAccommodative response was not significantly different between the three types of multifocal contact lenses at each of the accommodative stimulus levels (p > 0.05). Accommodative lag increased for higher stimulus levels for all 3 types of contact lenses. Ocular aberrations were not significantly different between these 3 contact lens designs at each of the different viewing distances (p > 0.05). In addition, optical aberrations did not significantly differ between different viewing distances for any of these lenses (p > 0.05). ANOVA revealed no significant difference in high and low contrast distance visual acuity as well as near visual acuity and contrast sensitivity function between the 3 multifocal contact lenses and spectacles (p > 0.05).ConclusionsThere was no statistically significant difference in accommodative response, optical aberrations or visual performance between the 3 multifocal contact lenses in early presbyopes.  相似文献   

12.
ObjectivesTo evaluate the utility of the Rose K2 XL semi-scleral contact lens (Menicon Co. Ltd., Nagoya, Japan) in the management of the irregular cornea.MethodsTwenty-seven subjects (34 eyes) with irregular corneas referred for contact lens fitting were evaluated. A diagnostic trial set was used in the fitting process. Once the trial lens was considered optimal, a final lens was ordered from the manufacturer with the necessary changes in power, edge lift and diameter. We analyzed visual acuity, number of lenses ordered and patients’ ability to wear and handle lenses.ResultsTwenty-three subjects (30 eyes) were fitted with the Rose K2 XL lens. Four subjects (4 eyes) decided not to conclude the fitting process for different reasons. Average logMAR visual acuity without correction and with the lens was 0.82 and 0.09, respectively (p < 0.001). An average of 1.4 ordered lenses (range 1–3) were necessary to achieve the optimal fit. Nineteen eyes (63%) were fitted with the first lens ordered. Three subjects (13%) had problems with lens handling, and three subjects (4 eyes) abandoned the wear of the lenses after three months due to discomfort (3 eyes) and unsatisfactory visual acuity (1 eye), respectively. Follow-up ranged from 6 to 9 months.ConclusionRose K2 XL semi-scleral contact lens provides good visual acuity and comfort in patients with irregular corneas.  相似文献   

13.
PurposeTo investigate the efficacy of spherical aberration (SA) correction with aspheric contact lenses (aspheric lenses) based on lens power, and compare the results with those of spherical contact lenses (spherical lenses).MethodsOcular higher-order aberrations were measured with a wavefront sensor, in 11 myopic subjects wearing an aspheric lens (Medalist Fresh fit (PUREVISION 2 HD); Bausch + Lomb) or a spherical lens (ACUVUE Oasys; Johnson & Johnson). Six different lens powers (−7.00 diopters (D), −5.00 D, −3.00 D, −1.00 D, +1.00 D, +3.00 D) were used for all subjects. The amount of SA correction from the contact lens at each power was calculated as the difference between SA with the contact lens on-eye and SA of the eye alone.ResultsFor the spherical lenses, SA correction was close to 0.00 μm for the +1.00 D lens, became more positive as the labeled lens power increased and became more negative as the labeled lens power decreased. For the aspheric lenses, SA correction was consistent, from −0.15 to −0.05 μm, for all lens powers except for the −1.00 D lens. SA correction for the spherical and aspheric lenses was significantly different at −7.00 D (p = 0.040), −3.00 D (p = 0.015), −1.00 D (p < 0.001), +1.00 D (p = 0.006), and +3.00 D (p < 0.001) powers.ConclusionAn aspheric lens is capable of correcting SA at different lens powers, and has SA correction in the range of −0.15 to −0.05 μm over a 6 mm aperture.  相似文献   

14.
ObjectiveTo evaluate the efficacy of contact lenses in visual rehabilitation of a series of patients with corneal scars/opacities.MethodRetrospective review of case records of 158 patients (n = 162 eyes) with poor vision subsequent to corneal scar/opacity, who underwent contact lens fitting, was done. Primary outcome assessed was quantum of additional improvement in vision with rigid gas permeable (RGP) or soft lenses over spectacles. Success was defined as visual improvement of ≥2 lines over that of spectacles and/or improvement of vision to ≥20/60 (LogMAR 0.48).ResultsRigid gas permeable lenses were fitted in 137 eyes and soft contact lenses in 25 eyes. Lenses were successful in improving visual acuity by two or more lines over that of spectacles in 70% eyes (113 of 162 eyes), of which RGP lens accounted for 85% (96 of 113 eyes). Alternative outcome of success was defined as attainment of reasonable functional vision of >20/60 (LogMAR 0.48). This could be achieved in 65% cases (105 of 162 eyes) of which 83% (88 eyes) were with use of RGP lenses. Almost one-fourth (23.4%) patients were children less than 15 years old. Soft contact lenses were attempted in 25 instances, where RGP lens could not be fitted and were successful in 17 (68%) of these. All these 17 patients were aphakes.ConclusionsRehabilitation of corneas with visually disabling corneal opacities is possible with usage of appropriate contact lenses even in young children.  相似文献   

15.
This six-year retrospective longitudinal study was conducted to examine the changes in the pattern of prescribing soft contact lenses in an optometry centre located in a University in South India. Details regarding the type of lenses, lens material, wearing pattern and the clinical diagnoses were analyzed from January 2006 to December 2011. A total of 1273 soft contact lens fits (n = 1273) were analyzed. Two-third of the total lenses dispensed was for females and their mean age (24.0 ± 8.3 yrs) was less than that of male (27.0 ± 11.2 yrs) lens users. Nearly 70% of them had myopia and 48% wore conventional soft contact lenses. During the studied six years, the percentage of conventional lenses declined by 60%. This study demonstrated a gradual and significant increase in popularity of disposable contact lenses and silicone hydrogel lens material which is comparable to the global trend.  相似文献   

16.
PurposeTo evaluate and compare the distribution of refractive power within the optic zone of different soft contact lenses and to investigate the effect of lens decentration on the power profiles.MethodsThe Nimo TR1504 instrument was used to measure the optical power across different aperture diameters (from 1.5 mm to 5.5 mm in steps of 0.5 mm) of four daily disposable contact lenses: DAILIES TOTAL1, Proclear 1-Day, SofLens daily disposable and 1-DAY ACUVUE MOIST. Measurements were performed using a wet cell. Power data were evaluated when contact lenses were in its centered position and after inducing different amounts of lens decentration (from 0.2 mm to 1.0 mm in steps of 0.2 mm).ResultsAll contact lenses showed an increase – more negative – in lens power with distance from the lens center. The amount of change varied depending on the lens. It was about 10% of lens power for DAILIES TOTAL1 (−0.29 diopters (D)), SofLens daily disposable (−0.36 D), and Proclear 1-Day (−0.32 D) whereas 1-DAY ACUVUE MOIST showed a percentage variation of 3.3% (−0.10 D). After inducing a lens decentration up to 1 mm, the power curves were shifted in the negative direction. However, the change obtained in lens power compared with well-centered position was always lower than a quarter of diopter both for all the lenses and aperture diameters.ConclusionsOur results showed a variation of the refractive power from the lens center, becoming more negative toward the periphery, with a negligible effect of the decentration for all disposable contact lenses studied.  相似文献   

17.
PurposeTo evaluate the performance of two experimental contact lenses (CL) designed to induce relative peripheral myopic defocus in myopic eyes.MethodsTen right eyes of 10 subjects were fitted with three different CL: a soft experimental lens (ExpSCL), a rigid gas permeable experimental lens (ExpRGP) and a standard RGP lens made of the same material (StdRGP). Central and peripheral refraction was measured using a Grand Seiko open-field autorefractometer across the central 60° of the horizontal visual field. Ocular aberrations were measured with a Hartman-Shack aberrometer, and monocular contrast sensitivity function (CSF) was measured with a VCTS6500 without and with the three contact lenses.ResultsBoth experimental lenses were able to increase significantly the relative peripheral myopic defocus up to −0.50 D in the nasal field and −1.00 D in the temporal field (p < 0.05). The ExpRGP induced a significantly higher myopic defocus in the temporal field compared to the ExpSCL. ExpSCL induced significantly lower levels of Spherical-like HOA than ExpRGP for the 5 mm pupil size (p < 0.05). Both experimental lenses kept CSF within normal limits without any statistically significant change from baseline (p > 0.05).ConclusionsRGP lens design seems to be more effective to induce a significant myopic change in the relative peripheral refractive error. Both lenses preserve a good visual performance. The worsened optical quality observed in ExpRGP was due to an increased coma-like and spherical-like HOA. However, no impact on the visual quality as measured by CSF was observed.  相似文献   

18.
PurposeTo evaluate the efficacy of two silicone hydrogel (SiH) contact lenses, approved for continuous wear for one week, following photorefractive keratectomy (PRK).MethodsForty seven myopic patients (94 eyes) undergone bilateral PRK were enrolled in this prospective, double-masked, comparative study. One eye of each patient was fitted with a Lotrafilcon B lens (Ciba Vision, Duluth, US; 30-day recommended replacement) whereas the fellow eye was fitted with an Asmofilcon A lens (Menicon, Nagoya, Japan; 14-day recommended replacement). Epithelial defect size was assessed using slit lamp biomicroscopy on the day of surgery and at days 1–4 post-operatively. Uncorrected and best-corrected visual acuity and retinal straylight (C-Quant, Oculus Optigerate, Germany) were evaluated pre-operatively and one month post-operatively.ResultsAverage epithelial defect size for Asmofilcon A and Lotrafilcon B was 25.5 ± 11.0 mm2 vs. 27.1 ± 9.9 mm2 at day 1 (p = 0.007) and 6.3 ± 7.0 mm2 vs. 9.2 ± 9.5 mm2 at day 2 (p = 0.012) post-operatively. Re-epithelialization at day 3 was completed in 87.2% of the eyes fitted with Asmofilcon A lenses, compared to 74.5% with Lotrafilcon B lenses (p = 0.012). At the 3rd post-operative day 29.8% of re-epithelialized eyes showed irregular suture with Lotrafilcon B, compared to 12.8% eyes with Asmofilcon A lenses (p < 0.001). Finally, no statistically significant differences were found post-operatively between the two lenses retinal straylight (p = 0.98) and best-corrected visual acuity (p = 0.68).ConclusionsSiH lenses can be used as an effective bandage after PRK due to the limited time requested for achieving complete corneal re-epithelialization. Faster and smoother epithelial healing is provided with Asmofilcon A over Lotrafilcon B lenses.  相似文献   

19.
PurposeReplacing soft contact lenses (CLs) on a daily basis brings a number of advantages, most notably, reduced exposure to deposits, disinfectants, allergens, and other contaminants. This retrospective study estimated the prevalence of problems in current wearers of reusable soft CLs and tested the effect of refitting “problem” patients with daily disposable (DD) hydrogel lenses.MethodsPrevalence was estimated from 398 current reusable CL wearers for: frequent/constant discomfort or dryness, ≥2 h of uncomfortable wear, ≥grade 2 conjunctival hyperaemia (0–4), or ≥grade 3 corneal staining (0–15). In the second part of the study, 217 reusable CL wearers classified as problem patients were randomly refitted with DD lenses manufactured from one of two materials: etafilcon A (n = 96) or nelfilcon A (n = 121) and reassessed 1 week later.ResultsThirty-nine percent (154/398) had some qualifying criterion: reduced comfortable wearing time (CWT), 20%; dryness, 20%; irritation, 5%; corneal staining, 8%; and hyperaemia, 7%. After refitting with DDs, the prevalence of reduced CWT was decreased from 65% to 51% (P = 0.0039), dryness from 60% to 41% (P < 0.0001) and corneal staining from 28% to 21% (P = 0.04). There was no significant change in the prevalence of irritation, or hyperaemia. Some differences were noted between the two lens materials.ConclusionsA high proportion of reusable soft lens wearers encounter clinically relevant signs or symptoms with their current CLs. This study provides evidence that refitting with DD lenses is a useful strategy for alleviating some of the common problems of CL wear.  相似文献   

20.
PurposeTo investigate the differences of functional visual acuity (FVA) and high order aberrations (HOAs) in relation to tinted and clear hydrogel soft contact lens (SCL) wear.MethodsA prospective comparative study was performed in 16 eyes of 16 healthy volunteers. Dynamic visual acuity (using a FVA measurement system) and higher-order aberrations (using a wavefront sensor) were compared in subjects wearing two types of soft contact lenses: 1-day Acuvue® (Vistakon, Jacksonville, FL) clear and the 1-day Acuvue® DefineTM (Vistakon, Jacksonville, FL) tinted lens. The blink rates were recorded during FVA testing. The correlation between the difference of HOAs and differences in FVA values was analyzed.ResultsThe mean LogMAR FVA scores with clear and tinted SCLs were 0.07 ± 0.13 and 0.14 ± 0.17 (P < 0.05). The mean blink frequencies with clear and tinted SCL wear were 18.4 ± 8.3 and 25.3 ± 4.7 blinks/min (P < 0.05). Both 3rd-order aberrations and total HOAs showed statistically significant differences between the two types of soft contact lenses for 6 mm pupil measurements (P < 0.05). A significant positive linear correlation was observed between ΔHOAs and ΔLogMAR FVA for 6 mm pupil measurements (R = 0.53, P = 0.04).ConclusionsTinted contact lens wear appears to induce a reduction in optical quality. Functional visual acuity measurement is a useful procedure to study the changes of visual performance and quality in tinted contact lens wear.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号