首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 127 毫秒
1.
We report rapid and efficient electrophoretic separations of N-glycans on microfluidic devices. Using a separation length of 22 cm and an electric field strength of 750 V/cm, analysis times were less than 3 min, and separation efficiencies were between 400,000 and 655,000 plates for the N-glycans and up to 960,000 plates for other sample components. These high efficiencies were necessary to separate N-glycan positional isomers derived from ribonuclease B and linkage isomers from asialofetuin. Structural isomers of N-glycans derived from a blood serum sample of a cancer patient were also analyzed to demonstrate that clinically relevant, complex samples could be separated on-chip with efficiencies similar to those derived from model glycoproteins. In addition, we compared microchip and capillary electrophoresis under similar separation conditions, and the microchips performed as well as the capillaries. These results confirmed that the noncircular cross section of the microchannel did not hamper separation performance. For all experiments, the glycan samples were derivatized with 8-aminopyrene-1,3,6-trisulfonic acid to impart needed charge for electrophoresis and a fluorescent label for detection.  相似文献   

2.
The detailed characterization of protein N-glycosylation is very demanding given the many different glycoforms and structural isomers that can exist on glycoproteins. Here we report a fast and sensitive method for the extensive structure elucidation of reducing-end labeled N-glycan mixtures using a combination of capillary normal-phase HPLC coupled off-line to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) and TOF/TOF-MS/MS. Using this method, isobaric N-glycans released from honey bee phospholipase A2 and Arabidopsis thaliana glycoproteins were separated by normal-phase chromatography and subsequently identified by key fragment ions in the MALDI-TOF/TOF tandem mass spectra. In addition, linkage and branching information were provided by abundant cross-ring and "elimination" fragment ions in the MALDI-CID spectra that gave extensive structural information. Furthermore, the fragmentation characteristics of N-glycans reductively aminated with 2-aminobenzoic acid and 2-aminobenzamide were compared. The identification of N-glycans containing 3-linked core fucose was facilitated by distinctive ions present only in the MALDI-CID spectra of 2-aminobenzoic acid-labeled oligosaccharides. To our knowledge, this is the first MS/MS-based technique that allows confident identification of N-glycans containing 3-linked core fucose, which is a major allergenic determinant on insect and plant glycoproteins.  相似文献   

3.
Recently, glycans have been recognized as valuable biomarkers for various disease states. In particular, sialoglycans, which have sialic acids at their terminal end, are likely to have relevance to diseases such as cancer and inflammation. Mass spectrometry (MS) has become an indispensable tool for biomarker discovery. However, matrix-assisted laser desorption ionization (MALDI) MS of sialoglycans normally causes loss of sialic acid. Methylesterification or amidation of carboxyl functionality in sialic acid has been reported to suppress the loss of sialic acids. We found that the modifications of alpha2,3-linked sialic acids proceed less efficiently than those at alpha2,6-linkages. Furthermore, the modifications of the alpha2,3-linked sialic acids are incomplete. This variability in the extent of derivatization presents a major problem in terms of glycan biomarker discovery using MALDI MS. In this study, we developed a novel amidation using acetohydrazide which can completely modify both types of linkages of sialoglycans. With the use of this method, we demonstrate MS profiling of N-linked glycans released from a bovine fetuin which is rich in alpha2,3-linked sialic acids.  相似文献   

4.
A capillary electrophoresis-mass spectrometric (CE-MS) method is described for the simultaneous analysis of uncharged and charged glycans. The glycans were labeled with the negatively charged tag 8-aminopyrene-1,3,6-trisulfonate by reductive amination and separated in an ammonium acetate buffer. A Q-Trap instrument was used for mass spectrometric detection. The CE-MS method was first optimized using maltooligosaccharides and ribonuclease B N-glycans and then applied to the characterization of enzymatically released N-glycans from the glycoprotein cellobiohydrolase I. The method, as developed, allowed differentiation of phosphorylated isomers and MS/MS provided useful structural information. Further structural evidence was obtained by studying the methylated glycans in off-line ESI-MS/MS experiments and by using a combination of chemical and enzymatic sequencing.  相似文献   

5.
Guttman M  Scian M  Lee KK 《Analytical chemistry》2011,83(19):7492-7499
Hydrogen/deuterium exchange coupled to mass spectrometry (HDX-MS) has emerged as a technique for studying glycoproteins, which are often refractory to classical methods. Glycan chains are generally assumed to exchange protons very rapidly, making them invisible to this technique. Here, we show that under conditions commonly used for HDX-MS, acetamido groups within glycan chains retain a significant amount of deuterium. Using mono- and polysaccharide standards along with glycopeptides from a panel of glycoproteins, we demonstrate that N-acetyl hexosamines, along with modified Asn side chains, are responsible for this effect. Model compounds for sialic acid also displayed similar exchange kinetics, but terminal sialic acids in the context of an entire glycan chain did not contribute to deuterium retention. Furthermore, the presence of sialic acid appears to enhance the exchange rate of the nearby N-acetyl glucosamines. The ability to detect deuterium exchange at the glycan level opens the possibility of applying HDX-MS to monitor glycan interactions and dynamics.  相似文献   

6.
Post-translational modifications, in particular glycosylation, represent critical structural attributes that govern both the pharmacodynamic and pharmacokinetic properties of therapeutic glycoproteins. To guarantee safety and efficacy of recombinant therapeutics, characterization of glycosylation present is a regulatory requirement. In the current paper, we applied a multidimensional strategy comprising a shallow anion exchange gradient in the first dimension, followed by analysis using the recently introduced 1.7 μm HILIC phase in the second dimension for the comprehensive separation of complex N-glycans present on the European Biological Reference Preparation (BRP) 3 erythropoietin standard. Tetra-antennary glycans with multiple sialic acids and poly-N-acetyl lactosamine extensions were the most abundant oligosaccharides present on the molecule. Site-specific glycan analysis was performed to examine microheterogeneity. Tetra-antennary glycans with up to four sialic acids and up to five poly-N-acetyl lactosamine extensions were observed at asparagine 24 and 83, while biantennary glycans were the major structures at asparagine 38. The combined AEC x UPLC HILIC allows for the rapid and comprehensive analysis of complex N-glycosylation present on therapeutic glycoproteins, such as BRP3 erythropoietin.  相似文献   

7.
Glycosylated proteins play important roles in a large number of biological processes. Therefore, a complete characterization in terms of glycan structures and glycoform heterogeneity is needed. In this paper, a combined approach based on glycan and intact glycoprotein analysis by capillary zone electrophoresis-electrospray-mass spectrometry (CZE-ESI-MS) is presented. Based on a new capillary coating, a CZE-ESI-MS method for the separation and characterization of intact glycoproteins has been developed and compared to a method recently introduced for the characterization of erythropoietin. The excellent glycoform separation results in high-quality mass spectra, high dynamic range, and good sensitivity, allowing the correct characterization of minor glycan modifications. Additionally, a CZE-ESI-MS separation method for underivatized N-glycans has been developed. The separation of glycans differing in the degree of sialic acids and repeats of noncharged carbohydrates is achieved. The separation power of the method is demonstrated by obtaining mobility differences in glycans differing only by 16 Da. A time-of-flight mass spectrometer allowed the correct identification of the glycan composition based on high mass accuracy and resolution, identifying even minor modifications such as the exchange of "O" by "NH". An ion trap mass spectrometer provided structural information of the underivatized glycans from fragmentation spectra. The general applicability of both methods to glycoprotein analysis is illustrated for erythropoietin, fetuin, and alpha1-acid glycoprotein. The results obtained by the glycan analysis allowed an unequivocal glyco-assignment to the masses obtained for the intact proteins as long as the protein backbone is well characterized. Furthermore, modifications found for intact proteins can be attributed to differences in the glycostructure.  相似文献   

8.
2-Aminopyridine (PA)-derivatized oligosaccharides from IgG were analyzed by using reversed-phase HPLC/mass spectrometry (RP-HPLC/MS) and a MS(n) spectral library, in particular, focusing on two pairs of isomers incompletely separated or coeluted in chromatograms. We previously reported that MS(n) spectral matching considering both major fragment ions (m/z) and intensities is useful and applicable to the structural assignment of PA-oligosaccharide isomers. In this study, MS(n) spectral matching based on the MS(n) spectral library was applied to the assignment of these PA-oligosaccharide isomers in IgG. Its usefulness was investigated by comparing it to the conventional two-dimensional mapping method based on retention time indexes. Specifically, we focus on the assignment and quantification of the isomers, which are coeluted in chromatograms. From this, we propose a new method using MS(n) spectral matching and the working curve on which are plotted the relative intensities of selected fragment ions in their MS(2) spectra versus various mixtures of the isomers. This new method demonstrated that the obtained quantities coincide very well with those estimated after separating by a combination of lectin and reversed-phase columns. This means that separation by RP-HPLC/MS is greatly simplified because complete separation of the isomers is no longer required. Application of this new method was tested by using the two other pairs of fucosylated and nonfucosylated PA-oligosaccharides from IgG. The results showed that this method works for them as well.  相似文献   

9.
A reversed-phase high-performance liquid chromatography (HPLC) separation approach has been combined with ion mobility/time-of-flight (TOF) mass spectrometry in order to characterize a combinatorial peptide library designed to contain 4000 peptides of the general form NH2-Xxx-Xxx-XXX-CO2H, NH2-Ala-Xxx-Xxx-Xxx-CO2H, NH2-Ser-Ala-Xxx-Xxx-Xxx-CO2H and NH2-Leu-Ser-Ala-Xxx-Xxx-Xxx-CO2H (where Xxx represents a randomization over 10 different amino acids: Ala, Arg, Asp, Glu, Gly, Leu, Lys, Phe, Ser, and Val). Addition of the gas-phase mobility separation between the HPLC separation and TOF measurement dimensions makes it possible to resolve many peptide isomers that have identical retention times (and masses).  相似文献   

10.
Characterization of the N-glycosylation present in the Fc region of therapeutic monoclonal antibodies requires rapid, high-resolution separation methods to guarantee product safety and efficacy during all stages of process development. Determination of fucosylated oligosaccharides is particularly important during clone selection, product characterization, and lot release as fucose has been shown to adversely affect the ability of mAbs to induce antibody dependent cellular cytotoxicity (ADCC). Here, we apply a general capillary electrophoresis optimization strategy to separate functionally relevant fucosylated and afucosylated glycans on mononclonal antibody products in the presence of several high mannose oligosaccharides. The N-glycans chosen represent those most commonly reported on CHO cell derived therapeutic antibodies. A rapid (<7 min) high-resolution separation of 12 commonly reported and functionally important IgG glycans was developed by systematically evaluating the effects of selectivity (boric acid) and efficiency (linear polyacrylamide) enhancing additives. The approach can be used to rapidly optimize capillary electrophoresis separation of other glycan mixtures. Following optimization, the method was applied to overnight sample processing for automated 96 well plate-based glycosylation analyses of two nonproprietary therapeutic monoclonal antibodies, demonstrating ruggedness and suitability for high-throughput process and product monitoring applications.  相似文献   

11.
Extensive cross-ring fragmentation ions, which are very informative of the linkages of the monosaccharide residues constituting these molecules, were readily observed in the MALDI-TOF/TOF/MS/MS spectra of oligosaccharides. These ions, in some cases, were more intense than the commonly observed Y and B ions. The A-type ions observed for the simple oligosaccharides allowed the distinction between alpha(1-4)- and alpha(1-6)-linked isobaric structures. The distinction was based not merely on the differences in the type of ions formed, but also on the ion intensities. For example, both alpha(1-4)- and alpha(1-6)-linked isobaric structures produce ions resulting from the loss of approximately 120 m/z units, but with different intensities, as a result of the fact that they correspond to two different ions (i.e., 0,4A- and 2,4A-ions), requiring different energies to be formed. Abundant A- and X-type ions were also observed for high-mannose N-glycans, allowing the determination of linkages. In addition, the high resolution furnished by MALDI-TOF/TOF allowed determination of certain ions that were commonly overlooked by MALDI-TOF or MALDI-magnetic sector instruments as a result of their lower resolution. Moreover, as a result of the fact that MS/MS spectra for parent ions and all fragment ions are acquired under the same experimental conditions, accurate determination of the molar ratios of isomeric glycans in a mixture analyzed simultaneously by MALDI-TOF/TOF tandem MS becomes possible.  相似文献   

12.
A bottom-up approach to achieve full oligosaccharide and glycan characterization has been described that is based on an MSn fragment spectral library and associated tools. The library, identified as FragLib, was initiated with known standards and commercially available oligomers prepared as methylated derivatives. As a component of this effort a set of software tools has been written for storing, organizing, and comparing spectral files, including the identification of isobaric mixtures. These tools provide a facile and objective evaluation of structural details including interresidue linkage, monomer identification, anomeric configuration, and branching. The tools are components of a web-based data sharing interface for sample tracking, spectral searching, and structural confirmation. Applications have been detailed with unknown samples and previously characterized glycoconjugates.  相似文献   

13.
Accurate and reproducible quantification of glycans from protein drugs has become an important issue for quality control of therapeutic proteins in biopharmaceutical and biotechnology industries. Mass spectrometry is a promising tool for both qualitative and quantitative analysis of glycans owing to mass accuracy, efficiency, and reproducibility, but it has been of limited success in quantitative analysis for sialylated glycans in a high-throughput manner. Here, we present a solid-phase permethylation-based total N-glycan quantitative method that includes N-glycan releasing, purification, and derivatization on a 96-well plate platform. The solid-phase neutralization enabled us to perform reliable absolute quantification of the acidic N-glycans as well as neutral N-glycans from model glycoproteins (i.e., chicken ovalbumin and porcine thyroglobulin) by only using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Furthermore, low-abundance sialylated N-glycans from human serum prostate specific antigen (PSA), an extremely valuable prostate cancer marker, were initially quantified, and their chemical compositions were proposed. Taken together, these results demonstrate that our all-inclusive glycan preparation method based on a 96-well plate platform may contribute to the precise and reliable qualitative and quantitative analysis of glycans.  相似文献   

14.
Liu X  Li X  Chan K  Zou W  Pribil P  Li XF  Sawyer MB  Li J 《Analytical chemistry》2007,79(10):3894-3900
A simple and rapid "one-pot" methylation method to esterify sialic acids and construct a permanent charge was developed for N-linked glycan analysis, which combined complete nonspecific proteolytic digestion and methylation. A mixture of Asn-glycans prepared from Pronase E digestion of the glycoprotein was passed through a cation-exchange column to convert carboxylic acids to the Na+ form before being methylated with methyl iodide. Derivatives could be easily purified with a hydrophilic affinity chromatography cartridge. Mass spectrometry analysis was performed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF) and MALDI-TOF/TOF. The mass spectrometric data indicated that carboxylic acids were methylated in addition to the formation of a quaternary ammonium in the amino group of asparagine residues. Three model glycoproteins, including ribonuclease B, ovalbumin, and transferrin, were employed to demonstrate the merits of this technique. Results showed that the stabilization of sialic acid was achieved in addition to the formation of a permanent charge. Compared to the analysis of underivatized N-glycans, detection sensitivity improved approximately 10-fold. The new technique was further evaluated with glycan profiling of serum transferrin and proved to be a sensitive method for the characterizing protein glycosylation.  相似文献   

15.
An automated analytical approach is proposed for simultaneous characterization of glycan and peptide moieties in pronase-generated glycopeptides. The proposed method is based on the use of a new pronase-immobilized enzyme reactor for the on-line rapid digestion of the target glycoprotein. By coupling the bioreactor to a Hypercarb chromatographic trap column, on-line selective glycopeptide enrichment prior to normal-phase liquid chromatography-mass spectrometry was obtained. A detailed study was carried out for integration and automation of each phase of the proposed analytical procedure. On-line digestion allowed extensive cleavage of the model protein (ribonuclease B), yielding to glycopeptides with peptide moieties up to eight amino acids, carrying the Man5-Man9 N-glycans each, selectively resolved on an Amide-80 column. The use of a linear ion trap instrument resulted in efficient ion capture and led to MS3 acquisition times and spectra quality similar to those for MS2, allowing the unambiguous identification of glycan (MS2) and peptide (MS3) sequences. The proposed procedure reduces the glycoprotein analysis time from approximately 3 days, as in most of the traditional off-line methods, to approximately 1 h.  相似文献   

16.
Negative-ion fragmentation of N-glycans has been proven to be more informative than that of positive-ion. In particular, it defines structural features such as the specific composition of the two antennae and the location of fucose. However, negative-ion formation of neutral N-glycans by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) remains a challenging task, and the detection limit of N-glycans in negative-ion mode is merely at the subpicomole level. Thus, practical applications are limited. In this study, combinations of five liquid matrices and nine anions were used to ionize N-glycans as anionic adducts, and their performances for sensitive analyses were evaluated. The best results were obtained with anion-doped liquid matrix G(3)CA, which consists of p-coumaric acid and 1,1,3,3-tetramethylguanidine; the detection limits of anion adducted N-glycans were 1 fmol/well for NO(3)(-), and 100 amol/well for BF(4)(-). Negative-ion MS(2) spectra of 1 fmol N-glycans were successfully acquired with a sufficient signal-to-noise ratio and were quite useful for MS-based structural determination. The anion-doped G(3)CA matrix opens the way for sensitive and rapid analysis of neutral N-glycans in negative-ion MALDI at a low femtomole level.  相似文献   

17.
A high-speed quantitative analysis of aromatic isomers in a jet fuel sample is performed using comprehensive two-dimensional gas chromatography (GC x GC) and chemometrics. A GC x GC separation time of 2.8 min is achieved for three aromatic isomers in jet fuel, which is 5 times faster than a reference method in which a singlecolumn separation resolves two of the three isomers of interest. The high-speed GC x GC separation is more than 10 times faster than a recent GC x GC separation that fully resolves the three components of interest in gasoline. The high-speed GC x GC analysis of jet fuel is accomplished through short GC columns, high gas velocities, and partial chromatographic peak resolution followed by chemometric resolution of overlapped peaks. The standard addition method and an objective retention time alignment algorithm are used to correct for retention time variations prior to the chemometric data analysis. The standard addition method corrects for chemical matrix effects that cause analytes in complex samples to have peak shapes, widths, and retention times that differ considerably from those of calibration standards in pure solvents. The retention time alignment algorithm corrects for the relatively small retention time variations caused by fluctuating instrumental parameters such as flow rate and temperature. The use of data point interpolation in the retention time alignment algorithm results in a more accurate retention time correction then previously achieved. The generalized rank annihilation method (GRAM) is the chemometric technique used to resolve the overlapped GC x GC peaks. The correction of retention time variations allows for successful GRAM signal deconvolution. Using the retention time alignment algorithm, GRAM quantification accuracy and precision are improved by a factor of 4. The methodology used in this paper should be applicable to other comprehensive separation methods, such as two-dimensional liquid chromatography, liquid chromatography coupled with capillary electrophoresis, and liquid chromatography coupled with gas chromatography.  相似文献   

18.
Glycopeptides prepared from 1 nmol of a mixture of glycoproteins, transferrin, and ribonuclease B by lysylendopeptidase digestion were isolated by lectin and cellulose column chromatographies, and then they were analyzed by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry and MALDI-quadrupole ion trap (QIT)-TOF mass spectrometry which enables the performance of MS ( n ) analysis. The lectin affinity preparation of glycopeptides with Sambucus nigra agglutinin and concanavalin A provides the glycan structure outlines for the sialyl linkage and the core structure of N-glycans. Such structural estimation was confirmed by MALDI-TOF MS and MALDI-QIT-TOF MS/MS. Amino acid sequences and location of glycosylation sites were determined by MALDI-QIT-TOF MS/MS/MS. Taken together, the combination of lectin column chromatography, MALDI-TOF MS, and MALDI-QIT-TOF MS ( n ) provides an easy way for the structural estimation of glycans and the rapid analysis of glycoproteomics.  相似文献   

19.
Minor N-linked glycans containing N-glycolylneuraminic acid residues and/or α-Gal epitopes (i.e., galactose-α1,3-galactose residues) have been reported to be present in recombinant monoclonal antibody (mAb) therapeutics. These contaminations are due to their production processes using nonhuman mammalian cell lines in culture media containing animal-derived materials. In case of the treatment of tumors, we inevitably use such mAbs by careful risk-benefit considerations to prolong patients' lives. However, expanding their clinical applications such as for rheumatism, asthma, and analgesia demands more careful evaluation of the product characteristics. The present work for detailed evaluations of N-glycans demonstrates the methods using capillary electrophoresis with laser-induced fluorescence detection (CE-LIF) and a combination of high-performance liquid chromatography and electrospray ionization time-of-flight mass spectrometry. The CE-LIF method provides excellent separation of both major and minor N-glycans from six commercial mAb pharmaceuticals within 30 min and clearly indicates that a possible trigger of immunogenicity in humans due to the presence of nonhuman N-glycans is present. We strongly believe that the proposed method will be a powerful tool for the analysis of N-glycans of recombinant mAb products in various development stages, such as clone selection, process control, and routine release testing to ensure safety and efficacy of the products.  相似文献   

20.
Zhang W  Wang H  Tang H  Yang P 《Analytical chemistry》2011,83(12):4975-4981
Stable isotopic labeling coupled with mass spectrometry analysis is a promising method of detecting quantitative variations in glycans, which may result in aberrant glycosylation in many disorders and diseases. Although various isotopic labeling methods have been used for relative glycan quantitation, enzymatic (18)O labeling, which offers advantages for glycomics similar to those by protease-catalyzed (18)O labeling for proteomics, has not been developed yet. In this study, endoglycosidase incorporated (18)O into the N-glycan reducing end in (18)O-water as N-glycans were released from glycoproteins, rendering glycan reducing-end (18)O labeling (GREOL) a potential strategy for relative glycan quantitation. This proposed method provided good linearity with high reproducibility within 2 orders of magnitude in dynamic range. The ability of GREOL to quantitatively discriminate between isomeric hybrid N-glycans and complex N-glycans in glycoproteins was validated due to the distinct substrate specificities of endoglycosidases. GREOL was also used to analyze changes in human serum N-glycans associated with hepatocellular carcinoma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号