首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study, an indirect forced convection solar drying system was tested for drying of palm oil fronds. The drying of 100 kg of palm oil fronds via solar drying system reduced the moisture content from 60% (w.b) to 10% (w.b) in 22 h (3 d of drying). During the drying process, the daily mean values of the drying chamber inlet temperature, drying chamber outlet temperature, drying chamber air temperature, and solar radiation ranged from 26 °C to 75 °C, 25 °C–65 °C, 26 °C–67 °C, and 96 W/m2 to 1042 W/m2 respectively, with corresponding average values of 53 °C, 46 °C, 48 °C, and 580 W/m2. At average solar radiation of about 600 W/m2 and air flow rate 0.13 kg/s, the collector, drying system and pick-up efficiencies were found about 31%, 19% and 67% respectively. The specific moisture extraction rate (SMER) was 0.29 kg/kWh. The exergy efficiency varied between 10% and 73%, with an average of 47%. In addition, the improvement potential of solar drying system for palm oil fronds ranged from 8 W to 455 W, with an average of 172 W.  相似文献   

2.
《Applied Thermal Engineering》2001,21(17):1813-1828
Influence of thermal emittance on the performance of laminated solar control glazing is presented. A transient one-dimensional mathematical model allowing the prediction of conductive heat transfer within the glazing and convective and radiative heat transfer from the glazing towards the interior and exterior are considered separately. A constant normal incidence of air mass 2 solar radiation of 750 W/m2 was assumed. The redistribution of the component of the solar radiation absorbed by the laminated glass and the shading coefficient (SC) were calculated for solar transmittance, 0.05 to 0.35; thermal emittance of the inner surface of the glazing, 0.15 to 0.85; convective heat transfer coefficient for the exterior surface, 10–100 W/m2 K and exterior ambient temperatures of 15°C, 32°C and 45°C. The results indicate that as the emittance decreases, the SC decreases by 10–20% for all cases of ambient temperatures considered. The contribution from the convective mechanisms to the heat transfer to the interior is always higher than that from radiative process in the range of ambient temperatures considered. The results presented in this paper would help to decide whether for a given location of interest, the incorporation of a heat mirror glazing would make a meaningful reduction in the cooling load in enclosures with single glazed windows.  相似文献   

3.
An experimental and numerical model of a solar chimney was proposed in order to predict its performance under varying geometrical features in Iraqi environmental conditions. Steady, two dimensional, turbulent flow was developed by natural convection inside an inclined solar chimney. This flow was investigated numerically at inclination angles 15° to 60°, solar heat flux 150–750 W/m2 and chimney thickness (50, 100 and 150) mm. The experimental study was conducted using a single solar chimney installed on the roof of a single room with a volume of 12 m3. The chimney was 2 m long; 2 m wide has three gap thicknesses namely: 50, 100 and 150 mm. The performance of the solar chimney was evaluated by measuring the temperature of its glass cover, the absorbing wall and the temperature and velocity of induced air. The results of numerical model showed that; the optimum chimney inclination angle was 60° to obtain the maximum rate of ventilation. At this inclination angle, the rate of ventilation was about 20% higher than 45°. Highest rate of ventilation induced with the help of solar energy was found to be 30 air changes per hour in a room of 12 m3 volumes, at a solar radiation of 750 W/m2, inclined surface angle of 60°, aspect ratio of 13.3 and chimney length of 2 m. The maximum air velocity was 0.8 m/s for a radiation intensity of 750 W/m2 at an air gap of 50 mm thickness. No reverse air flow circulation was observed even at the largest gap of 150 mm. The induced air stream by solar chimney can be used for ventilation and cooling in a natural way (passive), without any mechanical assistance.  相似文献   

4.
A solar test collector has been designed for the testing of thermally absorbing coatings under controlled conditions. The design consists of a collector fed by a controlled temperature fluid within the range of 25–90°C (77–194°F). This temperature is maintained by a custom electronic controller. A small variable flow pump circulates water through three collector pipes at selected flow rates. Strip heaters coupled with a differential temperature controller compensate for edge losses associated with small collectors. Detailed design and operation data are presented and three black chrome and one non-selective absorber are analysed in detail by test collector measurements. Results show that efficiencies as high as 77 and 75 per cent (ΔT = 0) are obtained for 1.0 μm black chrome on copper and nickel plated steel, respectively. The lowest loss coefficients are about 3.8 W/mC for all black chrome/metal surfaces, with the highest being 8.4 W/mC for the black paint/metal sample. Also, a collector model is presented for comparison.  相似文献   

5.
An experimental investigation was carried out to study the effects of operating parameters on the local bed-to-wall heat transfer coefficient in a 4.5 m tall, 0.150 m diameter circulating fluidized bed with a bed temperature in the range of 65°C to 80°C, riser flow rate varying from 1400 litres/min to 2000 litres/min, bed inventory in the range of 15 kg to 25 kg of sand, and average sand sizes of 200 μm, 400 μm and 500 μm. A heat flux probe was attached to the riser wall at five different vertical locations for measuring the heat flux from the bed to the wall surface. From the present work, the heat transfer coefficient in the dilute phase was found to be in the range of 62 to 83 W/m2K, 51 to 74 W/m2K, and 50 to 59 W/m2 K for sand sizes of 200 μm, 400 μm and 500 μm, respectively. Relevant mathematical correlations were developed to predict local heat transfer coefficient based on the results of the practical work.  相似文献   

6.
Ultra-thin-channel solar water collector efficiency (UCSWC) was investigated theoretically and experimentally. An ultra-thin-channel solar water collector was constructed using several flat plates with an ultra-thin fluid channel formed using an adjustable flexible silicon frame inserted between the absorber plate and bottom plate. The advantages of the ultra-thin-channel solar water collector are low absorber plate temperature and low total water mass flow rate, resulting in considerable collector efficiency improvement with high outlet fluid temperature and low pump power requirement. A simple and general modeling method was developed to predict the collector efficiencies and mean temperatures of the glass cover, absorber plate and fluid. Good agreement was achieved between the calculated and experimental values. The superior collector efficiencies of the UCSWC are obtained as 82.2% and 75.5% for the inlet temperatures 30°C and 70°C, respectively, operating at a total fluid mass flow 8.3 × 10?3 kg/s and solar radiation incident of 1100 W/m2.  相似文献   

7.
The current paper presents experimental investigation of nucleate pool boiling of R-134a and R-123 on enhanced and smooth tubes. The enhanced tubes used were TBIIHP and TBIILP for R-134a and R-123, respectively. Pool boiling data were taken for smooth and enhanced tubes in a single tube test section. Data were taken at a saturation temperature of 4.44 °C. Each test tube had an outside diameter of 19.05 mm and a length of 1 m. The test section was water heated with an insert in the water passage. The insert allowed measurement of local water temperatures down the length of the test tube. Utilizing this instrumentation, local heat transfer coefficients were determined at five locations along the test tube. The heat flux range was 2.5–157.5 kW/m2 for the TBIIHP tube and 3.1–73.2 kW/m2 for the TBIILP tube. The resulting heat transfer coefficient range was 4146–23255 W/m2. °C and 5331–25950 W/m2. °C for both tubes, respectively. For smooth tube testing, the heat flux ranges were 7.3–130.7 kW/m2 and 7.5–60.7 kW/m2 for R-134a and R-123, respectively; with resulting heat transfer coefficient ranges of 1798.9–11,379 W/m2. °C and 535.4–3181.8 W/m2. °C. The study provided one of the widest heat flux ranges ever examined for these types of tubes and showed significant structure to the pool boiling curve that had not been traditionally observed. Additionally, this paper presented an investigation of enhanced tubes pool boiling models.  相似文献   

8.
An investigation has been made into the effect of oil concentration on evaporation heat transfer coefficients in refrigerant-oil mixtures flowing in a horizontal tube. A new correlation is presented for heat transfer coefficients in convective evaporation of refrigerant-oil mixtures that predicts the results of the present study within approximately ±20%. The paper reports measurements of evaporation heat transfer coefficients in refrigerants R12 and R22, both oil-free and with two concentrations of Shell Clavus 32 oil. A 1·8 m long ⅜ in O/D copper tube (8·05 mm I/D) was used, at evaporation temperatures of −5°C, 0°C and +5°C. Heat flux and mixture mass velocity were kept constant at 2500 W m−2 and 155 kg m−2 s−1, respectively, and measured coefficients were in the range of 1400 to 3900 W m−2 K−1. The results showed that, for a complete evaporator, 2% oil may be expected to increase the heat transfer coefficient by 12%, but 10% oil returns the coefficient to oil-free values.  相似文献   

9.
The thermal loss coefficient k of evacuated load bearing transparent silica aerogel tiles is determined for temperatures between 280 K and 400 K. The measurements were performed with the large guarded hot plate high vacuum system LOLA I, the reference plates of which can be pressed onto the samples with an adjustable load (0... 1 bar). For a 22mm layer of aerogel (density ρ ≈ 100...110g/liter) the loss coefficient varied between about k = 0.36 W//m2 K) at 280 K and k = 1.45 W/(m2.K) at 400 K, corresponding to a pseudo-conductivity λ = 8. 10?3 W/(m. K) and λ = 32. 10?3 W/(m. K), respectively. Thus at typical winter temperatures (inside 20 °C, outside ?10 °C to 0 °C), evacuated transparent aerogel could provide excellent thermal insulation as a spacer in double pane windows. It also could be used in passive solar systems, for example as a cover for Trombe walls or as a transparent insulating structure around house walls. The dramatic increase of thermal losses at higher temperatures is due to a transmission window for infrared radiation between 3 and 7 μm, Additional data reveal the influence of water adsorption and of air pressure on the thermal conductivity of aerogel.  相似文献   

10.
In this study, thermal performance of the salt gradient solar pond (SGSP), which of density gradient is artificially with sodium carbonate solution, was tested under Karabuk prevailing weather conditions in Turkey. A small‐scale prismatic glass tank was constructed with an area of 0.45 × 0.20 m2 and a depth of 0.25 m as solar pond. A series of experiments with four different density levels were conducted in July–August 2004. The variations of the temperature and density profiles were observed for each of experiment for a week. It was found that the maximum temperature difference between the bottom and surface of the pond is 21°C and maximum temperature in the lower convective zone (LCZ) has been measured as 49°C at the first experiment. The efficiency of the pond was evaluated 13.33% weekly mean radiation intensity of 524 W m?2 for the first experiment. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

11.
An analytical moisture diffusion model which considers the influence of external resistance to mass transfer is developed. The methodology to determine constant and variable moisture diffusion coefficients, Deff is proposed. A laboratory model of mixed-mode solar dryer is constructed to perform 16 experiments for different performance dependent variables under simulated indoor conditions. The potatoes (Solanum tuberosum) of Kufri Safed variety have been chosen as the test food product. The range of variables investigated is absorbed thermal energy (150–750 W/m2); air mass flow rate (0.009–0.022 kg/s); loading density (1.08–4.33 kg/m2) and sample thickness (5–18 mm). The efficiency results have been analysed to identify the value of each process variable leading to optimal operation of dryer. The study reveals that dryer with sample thickness of 8 mm and loading density of 4.33 kg/m2 can operate optimally for absorbed energy of 450 W/m2 and air mass flow rate of 0.017 kg/s.  相似文献   

12.
The radiative panel is an equipment combining the solar heating and nocturnal radiant cooling technology. This study conducted the thermal performance of radiative panels for both radiation and convection cooling. Using the cover test by the mirror polished aluminum plate, the net cooling capacity of radiative panel was tested. The net cooling capacity of the radiative panel and contribution degree of the radiation heat transfer and convection heat transfer to the net cooling capacity was computed using the simulation model, and the influences of the cloud, ambient temperature and inclination angle on the radiation cooling were discussed. From the experimental results, the net cooling capacity was 45–70 W/m2 when the radiative panel wasn’t covered, and the net cooling capacity was 10–30 W/m2 when the mirror polished aluminum plate existed on a clear night in February in Tianjin. From the simulation results, the net cooling capacity of the radiative panel was about 50–70 W/m2, and the radiation cooling was about 45 W/m2, being responsible for 64%–90% of the net cooling capacity. The temperature differences between radiative panel and environment were the main influencing factors for the radiation cooling capacity. With an increase of the temperature difference, the radiation cooling capacity increased, and when the variation 5 °C of the temperature difference, the radiation cooling capacity will increase about 10–20 W/m2. When it was partly cloudy, the radiation cooling capacity was about 50 W/m2 and the fall rate of the radiation cooling capacity was less than 24%. With an increase of the cloud, the radiation cooling will decrease significantly. When it was overcast, the radiative panel even absorbed heat around 45 W/m2 from the environment. When the tilt angle of radiative panel was less than 30°, the fall rate of the radiation cooling capacity was less than 11.3%. When the tilt angle was greater than 30°, the radiation cooling decreased significantly. In the case of being placed vertically, the radiation cooling capacity reduced by 84.8%.  相似文献   

13.
To contribute to the use of bio-based materials in the building sector, a novel bio-based wall panel, with a high thermal performance level, is proposed in this work. The panel is based on an ancient rural technique, widely diffused in southern Italy, which makes use of Arundo donax L. canes combined with gypsum plaster to build walls and ceilings of rural buildings. The enhancement of the thermal capacity of these panels by means of the introduction in the canes of a natural wax oleogel (WO) is proposed in this paper. A specific experimental campaign aiming at the comparison of traditional and innovative panels was carried out to assess the enhanced thermal performance of the proposed solution. The maximum value of heat flow absorbed from the panel with WO was 61.08 W/m2 around a mean panel temperature of 24°C, corresponding to the melting temperature range of the WO. The panel without WO at the same temperature absorbed an incoming heat flow of 34.64 W/m2 which is about 57% of the panel with WO. The panel with WO released at a temperature of about 27.5°C, a heat flow of 43.42 W/m2. At the same temperature of about 27.5°C, the panel without WO released a heat flow of 34.38 W/m2 which is about 80% that of the panel with WO. The results highlighted that the addition of natural WO has enhanced the thermal capacity of the panel facilitating heat dissipation through the borders. These characteristics make the panel a suitable component for internal partitions of controlled temperature zones such as residential rooms, storage food areas, livestock buildings, and where it is necessary to obtain a constant environmental temperature. In particular, the null or low toxicity of the panel's materials allows for partition use, also in hygienically safe environments.  相似文献   

14.
《Geothermics》2001,30(1):111-132
Equilibrium temperatures based on log data acquired during drilling stops in the Los Azufres geothermal field were used to study the relationship between temperature, depth and conductive heat flow that differentiate production from non-production areas. Temperature and thermal conductivity data from 62 geothermal wells were analyzed, displaying temperature–depth, gradient–depth, and ternary temperature–gradient–depth plots. In the ternary plot, the production wells of Los Azufres are located near the temperature vertex, where normalized temperatures are over 0.50 units, or where the temperature gradient is over 165°C/km. In addition, the temperature data were used to estimate the depth at which 600°C could be reached (5–9 km) and the regional background conductive heat flow (≈ 106 mW/m2). Estimates are also given for the conductive heat flow associated with the conductive cooling of an intrusive body (≈ 295 mW/m2), and the conductive heat flow component in low-permeability blocks inside the reservoir associated with convection in limiting open faults (from 69 to 667 mW/m2). The method applied in this study may be useful to interpret data from new geothermal areas still under exploration by comparing with the results obtained from Los Azufres.  相似文献   

15.
An experimental study of a closed-loop impingement spray cooling system to cool a 1 kW 6U electronic test card has been conducted. The system uses R134a as working fluid in a modified refrigeration cycle. The spray from four vapor assisted nozzles is arranged to cover a large ratio of the heated area of the card. Investigations are currently focused on effects of mass flow rate, nozzle inlet pressure and spray chamber pressure. Experimental results are promising with a stable average temperature of around 23 °C being maintained at the heated surface, and maximum temperature variation of about 2 °C under suitable operating conditions. Heat transfer coefficients up to 5596 W/m2 K can be achieved with heat flux input around 50,000 W/m2 in this study. It is found that cooling performance improved with increasing mass flow rate, nozzle inlet pressure and spray chamber pressure, whereas uniformity of the heated surface temperature can only be improved with higher mass flow rate and nozzle inlet pressure. The mechanisms for the enhanced performance are also presented.  相似文献   

16.
In this study, experiments were performed to examine characteristics of flow boiling heat transfer and pressure drop of a low global warming potential refrigerant R32 flowing in a horizontal copper circular tube with 1.0 mm inside diameter for the development of a high-performance heat exchanger using small-diameter tubes or minichannels for air conditioning systems. Axially local heat transfer coefficients were measured in the range of mass fluxes from 30 to 400 kg/(m2·s), qualities from 0.05 to 1.0, and heat fluxes from 2 to 24 kW/m2 at the saturation temperature of 10°C. Pressure drops were also measured in the rage of mass fluxes from 30 to 400 kg/(m2·s) and qualities from 0.05 to 0.9 at the saturation temperature of 10°C under adiabatic condition. In addition, two-phase flow patterns were observed through a sight glass fixed at the tube exit with a digital camera. The characteristics of boiling heat transfer and pressure drop were clarified based on the measurements and the comparison with data of R410A obtained previously. Also, measured heat transfer coefficients were compared with two existing correlations.  相似文献   

17.
We performed tests for heat storage-type floor heating that employs a heat pump driven with nighttime electric power for 8 h (11 PM to 7 AM) as the heat source. The phase change material (PCM) applied was a package of mirabilite (Na2SO4 · 10H2O). The melting point is 32 °C, the freezing point 30 °C, and the stored heat amount 43 W · h/kg (ΔT = 10 °C). The test room for floor heating was a wooden structure without windows, and the floor area was 40 m2. The hot water panel (5 mm in thickness, made of plastic, 26 m2) was laid on the stage (1.2 m in height) inside the room and the PCM was superimposed on the upper surface of the stage (the total stored heat amount was 28.5 kW). Since the heat pump runs in cycles of 8-h operation and 16-h nonoperation, it needs an extracted heat amount of three times compared with the case of round-the-clock operation. For this reason, we have developed a wet film-type vertical heat extracting tube with a built-in Freon flashing pump to obtain extracted heat about three times greater than was previously possible. We have calculated the heat balance from the results of the tests for floor heating and have studied the practicability of this system. © 1998 Scripta Technica, Inc. Heat Trans Jpn Res, 26(2): 122–130, 1997  相似文献   

18.
A study on water solar collector performance having silver nanofluid as working fluid was carried out. In this study, 20-nm silver particles mixed with water at the concentrations of 1,000 and 10,000 ppm were undertaken in 3 small identical closed-loop flat-plate solar collectors, each with an area of 0.15 m × 1.0 m. The mass flux of the working fluid varied between 0.8 and 1.2 L/min-m2 and the inlet temperatures were controlled in the range of 35–65°C. The tests were performed outdoor under a steady-state condition. The experimental results showed that at the same Reynolds number, the convective heat transfer coefficient of the nanofluid inside the solar absorber tube at 1,000 ppm was slightly higher than that of water, and at 10,000 ppm, the heat transfer coefficient was about 2 times that of water. This meant that the overall heat loss coefficient of the solar collector with nanofluid could be reduced and more solar heat gain could be obtained, especially with a high inlet temperature of the working fluid. In our experiments, for 10,000 ppm concentration of silver nanoparticles, the optical characteristic and the thermal loss characteristic of the solar collector, under steady-state condition with a mass flux of 1.2 kg/min-m2, were 0.691 and 4.869 W/m2-K, compared with 0.684 and 7.178 W/m2-K, respectively for 1,000 ppm concentration and 0.702 and 8.318 W/m2-K for water. When the flow rate was different from the standard value, the solar thermal characteristics were also improved with the nanofluid.  相似文献   

19.
《Applied Thermal Engineering》2007,27(8-9):1352-1362
An experimental study of steady state flow and heat transfer has been conducted for the multiple plate porous insulation used in the reactor pressure vessels of ‘Magnox’ nuclear power stations. The insulation pack studied, consisting of seven dimpled stainless steel sheets and six plane stainless steel sheets, was of the type installed in the Sizewell A plant. A large scale experimental test facility, based on the guarded hot plate method, was used for measuring the effective thermal conductivity of Magnox reactor pressure vessel insulation, which consists of alternate layers of plain steel foil and dimpled foil. The measurements were made both with the fluid within the insulation pack nominally stationary and with an imposed flow through it, simulating leakage through the insulation pack. The experimental conditions corresponded to a heat flux of 75–1000 W/m2, fluid pressures of atmospheric to 5 bar gauge, pack orientations in range of 0°–45° relative to the horizontal, leakage velocities ranging from 0.05 m/s to 0.20 m/s and inlet air bulk temperatures ranging from 18 °C to 290 °C. Local values of effective thermal conductivity of 0.04–0.23 W/m K were obtained for the above experimental conditions. The heat transfer modes in the insulation pack were conduction through the contacting metallic foils, thermal radiation across the gas gaps, and conduction and convection in the air. The effective thermal conductivity of the porous insulation increased with increasing air pressure, inclination angle, and air velocity. Buoyancy effects increased with increasing inclination angle and air pressure.  相似文献   

20.
Non-uniform heat flux generated by microchips causes “hot spots” in very small areas on the microchip surface. These hot spots are generated by the logic blocks in the microchip bay; however, memory blocks generate lower heat flux on contrast. The goal of this research is to design, fabricate, and test an active cooling micro-channel heat sink device that can operate under atmospheric pressure while achieving high-heat dissipation rate with a reduced chip-backside volume, particularly for spot cooling applications. An experimental setup was assembled and electro-osmotic flow (EOF) was used thus eliminating high pressure pumping system. A flow rate of 82 μL/min was achieved at 400 V of applied EOF voltage. An increase in the cooling fluid (buffer) temperature of 9.6 °C, 29.9 °C, 54.3 °C, and 80.1 °C was achieved for 0.4 W, 1.2 W, 2.1 W, and 4 W of heating powers, respectively. The substrate temperature at the middle of the microchannel was below 80.5 °C for all input power values. The maximum increase in the cooling fluid temperature due to the joule heating was 4.5 °C for 400 V of applied EOF voltage. Numerical calculations of temperatures and flow were conducted and the results were compared to experimental data. Nusselt number (Nu) for the 4 W case reached a maximum of 5.48 at the channel entrance and decreased to reach 4.56 for the rest of the channel. Nu number for EOF was about 10% higher when compared to the pressure driven flow. It was found that using a shorter channel length and an EOF voltage in the range of 400–600 V allows application of a heat flux in the order of 104 W/m2, applicable to spot cooling. For elevated voltages, the velocity due to EOF increased, leading to an increase in total heat transfer for a fixed duration of time; however, the joule heating also got elevated with increase in voltage.  相似文献   