首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
In the presented work, alpha-benzoin oxime immobilized SP70 chelating resin was synthesized for separation and preconcentration of Pb(II), Cd(II), Co(II) and Cr(III). The optimization procedure for analytical parameters including pH, eluent type, flow rate, etc. was examined in order to gain quantitative recoveries of analyte ions. The effects of foreign ions on the recoveries of studied metal ions were also investigated. The detection limits (3sigma) were found to be 16.0, 4.2, 1.3, 2.4microgL(-1) for Pb, Cd, Co and Cr, respectively. The preconcentration factor was 75 for Pb, 100 for Cd, Co and Cr. The optimized method was validated with certified reference materials and successfully applied to the waters, crops and pharmaceutical samples with good results (recoveries greater than 95%, R.S.D. lower than 10%).  相似文献   

2.
A new tris(2-aminoethyl) amine (TREN) functionalized silica gel (SG-TREN) was prepared and investigated for selective solid-phase extraction (SPE) of trace Cr(III), Cd(II) and Pb(II) prior to its determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). Identification of the surface modification was characterized and performed on the basis of FT-IR. The separation/preconcentration conditions of analytes were investigated, including effects of pH, the shaking time, the sample flow rate and volume, the elution condition and the interfering ions. At pH 4, the maximum adsorption capacity of Cr(III), Cd(II) and Pb(II) onto the SG-TREN were 32.72, 36.42 and 64.61 mg g(-1), respectively. The adsorbed metal ions were quantitatively eluted by 5 mL of 0.1 mol L(-1) HCl. Common coexisting ions did not interfere with the separation. According to the definition of International Union of Pure and Applied Chemistry, the detection limits (3sigma) of this method for Cr(III), Cd(II) and Pb(II) were 0.61, 0.14 and 0.55 ng mL(-1), respectively. The relative standard deviation under optimum conditions is less than 4.0% (n=11). The application of this modified silica gel to preconcentration trace Cr(III), Cd(II) and Pb(II) of two water samples gave high accurate and precise results.  相似文献   

3.
Wang Q  Chang X  Li D  Hu Z  Li R  He Q 《Journal of hazardous materials》2011,186(2-3):1076-1081
In this work, the immobilization of 4-aminoantipyrine onto bentonite was carried out and it was then used to investigate the adsorption behavior of Cr(III), Hg(II) and Pb(II) ions from aqueous solutions. The separation and preconcentration conditions of analytes were investigated, including effects of pH, the shaking time, the sample flow rate and volume, the elution condition and the interfering ions. Under optimum pH value (pH 4.0), the maximum static adsorption capacity of the sorbent was found to be 38.8, 52.9 and 55.5 mg g(-1) for Cr(III), Hg(II) and Pb(II), respectively. 2.0 mL of 2% thiourea in 1.0 M HCl solution effectively eluted the adsorbed metal ions. The detection limit (3σ) of this method defined by IUPAC was found to be 0.12, 0.09 and 0.23 ng mL(-1) for Cr(III), Hg(II) and Pb(II), respectively. The relative standard deviation (RSD) was lower 3.0% (n=8). The developed method has been validated by analyzing certified reference materials and successfully applied to the determination of trace Cr(III), Hg(II) and Pb(II) in water samples with satisfactory results.  相似文献   

4.
An enrichment-separation procedure based on the coprecipitation of gold(III), palladium(II) and lead(II) ions with nickel(II)-5-methyl-4-(2-thiazolylazo) resorcinol complex has been developed. The analytical parameters including pH, amounts of 5-methyl-4-(2-thiazolylazo) resorcinol, sample volume, etc. was investigated for quantitative recoveries of Au(III), Pd(II) and Pb(II). Interference due to various cations and anions has also been investigated. The detection limits for analyte ions by 3sigma were 2.6 microg L(-1) for lead, 1.5 microg L(-1) for gold, 2.1 microg L(-1) for palladium. The accuracy of the method was evaluated by the analysis of certified reference materials (NIST SRM 2711 Montana soil, GBW 07309 Stream sediment). The proposed procedure was successfully applied to environmental samples for the determinations of analytes.  相似文献   

5.
A separation-preconcentration procedure based on the coprecipitation of lead(II) and chromium(III) ions with copper(II)-5-chloro-2-hydroxyaniline system has been developed. Effects of pH, sample volume and interferences on the recovery of the metal ions were investigated. The detection limits corresponding to three times the standard deviation of the blank were found to be 2.72 microg L(-1) for lead and 1.20 microg L(-1) for chromium. The preconcentration factor is 50. The effectiveness of the present method was assessed by determining analyte metals in GBW 07309 stream sediment and NIST SRM 1633b coal fly ash certified reference materials. The method was successfully applied to the determination of trace lead and chromium in environmental samples.  相似文献   

6.
A method for separation-preconcentration of Pb(II), Cr(III), Cu(II), Ni(II) and Cd(II) ions by membrane filtration has been described. The method based on the collection of analyte metal ions on a cellulose nitrate membrane filter and determination of analytes by flame atomic absorption spectrometry (FAAS). The method was optimized for several parameters including of pH, matrix effects and sample volume. The recoveries of analytes were generally in the range of 93-100%. The detection limits by 3 sigma for analyte ions were 0.02microgL(-1) for Pb(II), 0.3microgL(-1) for Cr(III), 3.1microgL(-1) for Cu(II), 7.8microgL(-1) for Ni(II) and 0.9microgL(-1) for Cd(II). The proposed method was applied to the determination of lead, chromium, copper, nickel and cadmium in tap waters and RM 8704 Buffalo River Sediment standard reference material with satisfactory results. The relative standard deviations of the determinations were below 10%.  相似文献   

7.
This paper describes a simple and accurate procedure for preconcentration of trace amounts of Fe(III), Pb(II) and Cr(III) ions. The preconcentration procedure is based on retention of p-xylenol blue chelates on Amberlite XAD-7. The analytes retained were eluted from Amberlite XAD-7 by using 1 mol L(-1) HCl. The influences of the analytical parameters including amounts of reagents, pH and type of eluent were also investigated. The detection limits of Fe, Pb and Cr were found to be 3.07, 18.6 and 3.27 microg L(-1), respectively. The accuracy of the procedure was checked by the analysis of an electrolytic copper wire sample. The relative error was less than 5%. The presented method was applied to the determination of Fe(III), Pb(II) and Cr(III) in water samples from Denizli, Turkey with good results such as recoveries more than 95%, relative standard deviations below 10%.  相似文献   

8.
A method for the preconcentration of some transition elements at trace level was proposed using a column filled with Amberlite XAD-2000 resin. Metal ions were adsorbed on XAD-2000 as their diethyldithiocarbamate chelates, then analytes retained on the resin were eluted by 1 mol L(-1) nitric acid in acetone and determined by flame atomic absorption spectrometry (FAAS). The influences of some analytical parameters including pH of sample solution, ligand amount, the type, concentration and volume of elution solution, flow rates of the sample and eluent solutions, adsorption capacity of the resin and sample volume on the preconcentration efficiency have been investigated. The influences of some matrix elements were also examined. The detection limit (N=20, 3 sigma) for Mn(II), Fe(II), Co(II), Cu(II), Cd(II), Zn(II), Pb(II) and Ni(II) were found as 0.20, 0.35, 0.25, 0.20, 0.20, 0.15, 0.45 and 0.25 microg L(-1), respectively. The validation of the procedure was carried out by analysis of certified reference materials. The proposed method was applied to natural waters and kale vegetable (Brassica oleracea var. acephala).  相似文献   

9.
Iminodiacetic acid functionality has been introduced on styrene-divinyl benzene co-polymeric beads and characterized by FT-IR in order to develop weak acid based cation exchange resin. This resin was evaluated for the removal of different heavy metal ions namely Cd(II), Cr(VI), Ni(II) and Pb(II) from their aqueous solutions. The results showed greater affinity of resin towards Cr(VI) for which 99.7% removal achieved in optimal conditions following the order Ni(II)>Pb(II)>Cd(II) with 65%, 59% and 28% removal. Experiments were also directed towards kinetic studies of adsorption and found to follow first order reversible kinetic model with the overall rate constants 0.3250, 0.2393, 0.4290 and 0.2968 for Cr(VI), Ni(II), Pb(II) and Cd(II) removal respectively. Detailed studies of Cr(VI) removal has been carried out to see the effect of pH, resin dose and metal ion concentration on adsorption and concluded that complexation enhanced the chromium removal efficacy of resin drastically, which is strongly pH dependent. The findings were also supported by the comparison of FT-IR spectra of neat resin with the chromium-adsorbed resin.  相似文献   

10.
A simple and effective method is presented for the separation and preconcentration of Th(IV), Ti(IV), Fe(III), Pb(II) and Cr(III) by solid phase extraction on 2-nitroso-1-naphthol impregnated MCI GEL CHP20P resin prior to their inductively coupled plasma-mass spectrometric determinations. The influence of analytical parameters including pH of the aqueous solution, flow rates of sample and eluent solutions and sample volume on the quantitative recoveries of analyte ions was investigated. Matrix effects caused by the presence of alkali, earth alkali and some metal ions in the analyzed solutions were investigated. The presented solid phase extraction method was applied to BCR-144R Sewage Sludge (domestic origin), BCR-141R Calcareous Loam Soil, NIST 1568a Rice Flour and NIST 1577b Bovine Liver certified reference materials (CRMs) for the determination of analyte ions and the results were in good agreement with the certified values. The separation procedure presented was also applied to the various natural water samples collected from Turkey with satisfactory results.  相似文献   

11.
A new method for the preconcentration of some trace metals (Co, Ni, Cu, and Cd) as complexed with ammonium pyrrolidynedithiocarbamate (APDC) was developed using a mini-column filled with Amberlite XAD-2000 resin. Metal contents were determined by flame atomic absorption spectrometry (FAAS) after the metal complexes accumulated on the resin were eluted with 1M HNO(3) in acetone. The effects of the analytical parameters such as sample pH, quantity of complexing agent, eluent type, resin quantity, sample volume, sample flow rate, and matrix ions were investigated on the recovery of the metals from aqueous solutions. The relative standard deviation (R.S.D.) of the method was <6%. The validation of the method was confirmed using two certified reference materials (CRM TMDW-500 Drinking Water and CRM SA-C Sandy Soil C). The method was successfully applied to some stream waters and mushroom samples from Eastern Black Sea Region (Trabzon city) of Turkey.  相似文献   

12.
A separation-preconcentration procedure based on the coprecipitation of cobalt(II) and manganese(II) ions with copper(II)-8-hydroxquinoline system has been developed. The analytical parameters including pH, amount of copper(II) as carrier element, amount of 8-hydroxquinoline, sample volume, etc., was investigated for the quantitative recoveries of Co(II) and Mn(II). No interferic effects were observed from the concomitant ions which are present in real samples. The detection limits for analyte ions by three sigma criteria were 0.86microgL(-1) for cobalt and 0.98microgL(-1) for manganese. The validation of the presented preconcentration procedure was performed by the analysis of NIST SRM 2711 Montana soil and GBW 07605 Tea certified reference materials. The procedure presented was applied to the analyte contents of real samples including natural waters and some food samples with successfully analytical results.  相似文献   

13.
An on-line solid phase extraction method for the preconcentration and determination of Cu(II) by flame atomic absorption spectrometry (FAAS) has been described. It is based on the adsorption of copper(II) ion onto a home made mini column of Chromosorb 105 resin loaded with pyrocatechol violet at the pH range of 5.0-8.0, then eluted with 1 mol L(-1) HNO(3). Several parameters, such as pH of the sample solution, amount of Chromosorb 105 resin, volume of sample and eluent, type of eluent, flow rates of sample and eluent, governing the efficiency and throughput of the method were evaluated. The concentration of the copper ion detected after preconcentration was in agreement with the added amount. At optimized conditions, for 15 min of preconcentration time (30 mL of sample volume), the system achieved a detection limit of 0.02 microg L(-1), with relative standard deviation 1.1% at 0.03 microg mL(-1) copper. The present method was found to be applicable to the preconcentration of Cu(II) in natural water samples.  相似文献   

14.
A sensitive and selective extractive preconcentration procedure for the determination of traces of lead in water samples has been developed. An alumina-sodium dodecyl sulfate (SDS) coated modified with 4-(4-methoxybenzylidenimine) thiophenole (MBITP) was used for preconcentration and determination of Pb(II) by flame atomic absorption spectrometry. Lead was adsorbed quantitatively on modified column due to its complexation with MBITP and quantitatively eluted using 5 mL 1 mol L(-1) nitric acid in acetone. The effects of parameters such as pH, amount of solid phase, amount of MBITP, flow rate, type and concentration of eluting agent were examined. The effect of interfering ions on the determination of Pb(II) was also investigated. The response of proposed method is linear in the concentration range 0.05-1.2 microg mL(-1) of Pb(II). The limit of detections (3S.D.(b)/m, n=4) and relative standard deviations (n=11) are 1.6 ng mL(-1) and 0.9%, respectively. The presented procedure was successfully applied for determination of lead content in real samples such as river, spring, waste and drinking water.  相似文献   

15.
A method for solid phase extraction (SPE) of gold(III) using Dowex M 4195 chelating resin has been developed. The optimum experimental conditions for the quantitative sorption of gold(III), pH, effect of flow rates, eluent types, sorption capacity and the effect of diverse ions on the sorption of gold(III) have been investigated. The chelating resin can be reused for more than 100 cycles of sorption-desorption without any significant change in sorption of gold(III) ions. The recovery values for gold(III) and detection limit (LOD) of gold were greater than 95% and 1.61 microg L(-1), respectively. The preconcentration factor was 31. The relative standard deviation of the method was <5%. The adsorption capacity of the resin was 8.1 mg g(-1). The proposed method has been applied for the determination of gold(III) in some real samples including water, soil and sediment samples.  相似文献   

16.
A two in one attempt for the removal of tartrazine and metal ions on activated carbon has been developed. The method was based on the modification of activated carbon with tartrazine then its application for the removal of Pb(II), Cd(II) and Cr(III) ions at different pH values. Tartrazine adsorption data were modelled using both Langmuir and Freundlich classical adsorption isotherms. The adsorption capacities qm were 121.3, 67 and 56.7mgg(-1) at initial pH values of 1.0, 6.0 and 10, respectively. The adsorption of tartrazine onto activated carbon followed second-order kinetic model. The equilibrium time was found to be 240min at pH 1.0 and 120min at pH 10 for 500mgL(-1) tartrazine concentration. A maximum removal of 85% was obtained after 1h of contact time. The presence of tartrazine as modifier enhances attractive electrostatic interactions between metal ions and carbon surface. The adsorption capacity for Pb(II), Cd(II) and Cr(III) ions has been improved with respect to non-modified carbon reaching a maximum of 140%. The adsorption capacity was found to be a pH dependent for both modified and non-modified carbon with a greater adsorption at higher pH values except for Cr(III). The enhancement percent of Pb(II), Cd(II) and Cr(III) at different pH values was varied from 28% to 140% with respect to non-modified carbon. The amount of metal ions adsorbed using static regime was 11-40% higher than that with dynamic mode. The difference between adsorption capacities could be attributed to the applied flow rate.  相似文献   

17.
An on-line flow system was used to develop a selective and efficient on-line sorbent extraction preconcentration system for cadmium. The method is based on adsorption of cadmium ions onto the activated carbon modified with methyl thymol blue. Then the adsorbed ions were washed using 0.5M HNO(3) and the eluent was used to determine the Cd(II) ions using flame atomic absorption spectrometry. The results obtained show that the modified activated carbon has the greatest adsorption capacity of 80 microg of Cd(II) per 1.0 g of the solid phase. The optimal pH value for the quantitative preconcentration was 9.0 and full desorption is achieved by using 0.5M HNO(3) solution. It is established that the solid phase can be used repeatedly without a considerable adsorption capacity loss. The detection limit was less than 1 ngmL(-1) Cd(II), with an enrichment factor of 1000. The calibration graph was linear in the range of 1-2000 ngmL(-1) Cd(II). The developed method has been applied to the determination of trace cadmium (II) in water samples and in the following reference materials: sewage sludge (CRM144R), and sea water (CASS.4) with satisfactory results. The accuracy was assessed through recovery experiments.  相似文献   

18.
A new sorbent 1-acylthiosemicarbazide-modified activated carbon (AC-ATSC) was prepared as a solid-phase extractant and applied for removing of trace Cu(II), Hg(II) and Pb(II) prior to their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The separation/preconcentration conditions of analytes were investigated, including effects of pH, the shaking time, the sample flow rate and volume, the elution condition and the interfering ions. At pH 3, the maximum static adsorption capacity of Cu(II), Hg(II) and Pb(II) onto the AC-ATSC were 78.20, 67.80 and 48.56 mg g−1, respectively. The adsorbed metal ions were quantitatively eluted by 3.0 mL of 2% CS(NH2)2 and 2.0 mol L−1 HCl solution. Common coexisting ions did not interfere with the separation. According to the definition of IUPAC, the detection limits (3σ) of this method for Cu(II), Hg(II) and Pb(II) were 0.20, 0.12 and 0.45 ng mL−1, respectively. The relative standard deviation under optimum conditions is less than 4.0% (n = 8). The prepared sorbent was applied for the preconcentration of trace Cu(II), Hg(II) and Pb(II) in certified and water samples with satisfactory results.  相似文献   

19.
Gallic acid was immobilized on Amberlite XAD-16 by coupling it through -N=N group. The resulting chelating resin Amberlite XAD-16 gallic acid, characterized by thermogravimetric analysis (TGA), infrared (IR) spectra and BET analysis, was used to preconcentrate Cr(III), Mn(II),Fe(III),Co(II), Ni(II) and Cu(II)ions. The resin was employed for the preconcentration of the metal ions present in river water and industrial area aqueous samples. Several parameters like effect of pH, effect of time, effect of sample volume and flow rate of sample were investigated. The sorption capacities for the resin were 216 micromol g(-1), 180 micromol g(-1), 403 micromol g(-1), 281 micromol g(-1), 250 micromol g(-1) and 344 micromol g(-1) for Cr(III), Mn(II), Fe(III), Co(II), Ni(II) and Cu(II) respectively. The preconcentration factors for Cr(III), Mn(II), Fe(III), Ni(II), Co(II) and Cu(II) were found out to be 300, 200, 400, 285.7, 300 and 400 respectively. The effect of various interfering ions was also studied. Results were validated by using standard addition method for river water sample.  相似文献   

20.
A method has been developed for the speciation of trace dissolved Fe(II) and Fe(II) in water by on-line coupling of flow injection separation and preconcentration with inductively coupled plasma mass spectrometry (ICPMS). Selective determination of Fe(III) in the presence of Fe(II) was made possible by on-line formation and sorption of the Fe(III)-pyrrolidinecarbodithioate (PDC) complex in a PTFE knotted reactor over a sample acidity range of 0.07-0.4 mol L(-1) HCl, elution with 1 mol L(-1) HNO3, and detection by ICPMS. Over a sample acidity range of 0.001-0.004 mol L(-1) HCl, the sum of Fe(III) and Fe(II), i.e., Fe(III + II), could be determined without the need for preoxidation of Fe(II) to Fe(III). The concentration of Fe(II) was obtained as the difference between those of Fe(III + II) and Fe(III). With a sample flow rate of 5 mL min(-1) and a 30-s preconcentration time, an enhancement factor of 12, a retention efficiency of 80%, and a detection limit (3s) of 0.08 microg L(-1) were obtained at a sampling frequency of 21 samples h(-1). The relative standard deviation (n = 11) was 2.9% at the 10 microg L(-1) Fe(III) level. Recoveries of spiked Fe(III) and Fe(II) in local tap water, river water, and groundwater samples ranged from 95% to 103%. The concentrations of Fe(III) and Fe(II) in synthetic aqueous mixtures obtained by the proposed method were in good agreement with the spiked values. The result for total iron concentration in the river water reference material SLRS-3 was in good agreement with the certified value. The method was successfully applied to the determination of trace dissolved Fe(III) and Fe(II) in local tap water, river water, and groundwater samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号