1.
Fluorescence imaging of green fluorescent protein (GFP) may be used to locate proteins in live cells and fluorescence lifetime imaging (FLIM) may be employed to probe the local microenvironment of proteins. Here we apply FLIM to GFP-tagged proteins at the cell surface and at an inhibitory natural killer (NK) cell immunological synapse (IS). We present a novel quantitative analysis of fluorescence lifetime images that we believe is useful to determine whether apparent FLIM heterogeneity is statistically significant. We observe that, although the variation of observed fluorescence lifetime of GFP-tagged proteins at the cell surface is close to the expected statistical range, the lifetime of GFP-tagged proteins in cells is shorter than recombinant GFP in solution. Furthermore the lifetime of GFP-tagged major histocompatibility complex class I protein is shortened at the inhibitory NK cell IS compared with the unconjugated membrane. Following our previous work demonstrating the ability of FLIM to report the local refractive index of GFP in solution, we speculate that these lifetime variations may indicate local refractive index changes. This application of our method for detecting small but significant differences in fluorescence lifetimes shows how FLIM could be broadly useful in imaging discrete membrane environments for a given protein.  相似文献   

2.
Frequency-domain fluorescence lifetime imaging microscopy (FLIM) has become a commonly used technique to measure lifetimes in biological systems. However, lifetime measurements are strongly dependent on numerous experimental parameters. Here, we describe a complete calibration and characterization of a FLIM system and suggest parameter optimization for minimizing measurement errors during acquisition. We used standard fluorescent molecules and reference biological samples, exhibiting both single and multiple lifetime components, to calibrate and evaluate our frequency domain FLIM system. We identify several sources of lifetime precision degradation that may occur in FLIM measurements. Following a rigorous calibration of the system and a careful optimization of the acquisition parameters, we demonstrate fluorescence lifetime measurements accuracy and reliability. In addition, we show its potential on living cells by visualizing FRET in CHO cells. The proposed calibration and optimization protocol is suitable for the measurement of multiple lifetime components sample and is applicable to any frequency domain FLIM system. Using this method on our FLIM microscope enabled us to obtain the best fluorescence lifetime precision accessible with such a system. Microsc. Res. Tech., 2009. © 2008 Wiley-Liss, Inc.  相似文献   

3.
Although single-photon fluorescence lifetime imaging microscopy (FLIM) is widely used to image molecular processes using a wide range of excitation wavelengths, the captured emission of this technique is confined to the visible spectrum. Here, we explore the feasibility of utilizing near-infrared (NIR) fluorescent molecular probes with emission >700 nm for FLIM of live cells. The confocal microscope is equipped with a 785 nm laser diode, a red-enhanced photomultiplier tube, and a time-correlated single photon counting card. We demonstrate that our system reports the lifetime distributions of NIR fluorescent dyes, cypate and DTTCI, in cells. In cells labelled separately or jointly with these dyes, NIR FLIM successfully distinguishes their lifetimes, providing a method to sort different cell populations. In addition, lifetime distributions of cells co-incubated with these dyes allow estimate of the dyes' relative concentrations in complex cellular microenvironments. With the heightened interest in fluorescence lifetime-based small animal imaging using NIR fluorophores, this technique further serves as a bridge between in vitro spectroscopic characterization of new fluorophore lifetimes and in vivo tissue imaging.  相似文献   

4.
5.
A microscope set-up and numerical methods are described which enable the measurement and reconstruction of three-dimensional nanosecond fluorescence lifetime images in every voxel. The frequency domain fluorescence lifetime imaging microscope (FLIM) utilizes phase detection of high-frequency modulated light by homodyne mixing on a microchannel plate image intensifier. The output signal at the image intensifier's phosphor screen is integrated on a charge coupled device camera. A scanning stage is employed to obtain a series of phase-dependent intensity images at equally separated depths in a specimen. The Fourier transform of phase-dependent data gives three-dimensional (3D) images of the Fourier coefficients. These images are deblurred using an Iterative Constrained Tikhonov–Miller (ICTM) algorithm in conjunction with a measured point spread function. The 3D reconstruction of fluorescence lifetimes are calculated from the deblurred images of the Fourier coefficients. An improved spatial and temporal resolution of fluorescence lifetimes was obtained using this approach to the reconstruction of simulated 3D FLIM data. The technique was applied to restore 3D FLIM data of a live cell specimen expressing two green fluorescent protein fusion constructs having distinct fluorescence lifetimes which localized to separate cellular compartments.  相似文献   

6.
Fluorescence lifetime imaging (FLIM) provides a complementary contrast mechanism to fluorescence intensity and ratio imaging in intact tissue. With FLIM the time-resolved decay in fluorescence intensity of (interacting) fluorophores can be quantified by means of time correlated single photon counting (TCSPC). Here we focus on fluorescence lifetime imaging in intact blood vessels. Requisites for imaging in intact tissue are good penetration depth and limited tissue damage. Therefore, in this pilot-study, we performed TCSPC-FLIM using two-photon laser scanning microscopy to determine, with sub-cellular resolution, the fluorescence lifetime of two fluorescent probes. First, we focused on the nucleic acid dye SYTO41 in the various compartments of cells in vitro and in situ in the wall of intact mouse carotid arteries. Second, it was assessed whether the interaction of the lectin WGA-FITC with the endothelial glycocalyx affects its fluorescence lifetime. Results showed comparable mono-exponential fluorescence lifetimes of SYTO41 in the nuclei of cells in vitro and in situ. The slightly shorter fluorescence lifetime observed in the cytoplasm allowed discrimination of the nuclei. SYTO41 displayed strong mitochondrial staining, as was verified by the mitochondrion-specific probe CMXRos. In addition, mitochondrial staining by SYTO41 was accompanied by a green shift in emission. In the mitochondrial region, SYTO41 showed a highly bi-exponential and relatively fast decay, with two distinct lifetime components. It is hypothesized that the fitted bi-exponential decay can either be contributed to (1) the mathematical approximation of the fluorescence intensity decay or (2) the presence of free and DNA-bound SYTO41 in the mitochondrial compartment, leading to two lifetime components. The fluorescence lifetime of WGA-FITC decreased by approximately 25% upon binding to the endothelial glycocalyx. From this study, we conclude that FLIM offers an additional contrast mechanism in imaging intact tissue and provides information on binding status between a probe and its ligand.  相似文献   

7.
A spectrograph with continuous wavelength resolution has been integrated into a frequency‐domain fluorescence lifetime‐resolved imaging microscope (FLIM). The spectral information assists in the separation of multiple lifetime components, and helps resolve signal cross‐talking that can interfere with an accurate analysis of multiple lifetime processes. This extends the number of different dyes that can be measured simultaneously in a FLIM measurement. Spectrally resolved FLIM (spectral‐FLIM) also provides a means to measure more accurately the lifetime of a dim fluorescence component (as low as 2% of the total intensity) in the presence of another fluorescence component with a much higher intensity. A more reliable separation of the donor and acceptor fluorescence signals are possible for Förster resonance energy transfer (FRET) measurements; this allows more accurate determinations of both donor and acceptor lifetimes. By combining the polar plot analysis with spectral‐FLIM data, the spectral dispersion of the acceptor signal can be used to derive the donor lifetime – and thereby the FRET efficiency – without iterative fitting. The lifetime relation between the donor and acceptor, in conjunction with spectral dispersion, is also used to separate the FRET pair signals from the donor alone signal. This method can be applied further to quantify the signals from separate FRET pairs, and provide information on the dynamics of the FRET pair between different states.  相似文献   

8.
Video-rate fluorescence lifetime-resolved imaging microscopy (FLIM) is a quantitative imaging technique for measuring dynamic processes in biological specimens. FLIM offers valuable information in addition to simple fluorescence intensity imaging; for instance, the fluorescence lifetime is sensitive to the microenvironment of the fluorophore allowing reliable differentiation between concentration differences and dynamic quenching. Homodyne FLIM is a full-field frequency-domain technique for imaging fluorescence lifetimes at every pixel of a fluorescence image simultaneously. If a single modulation frequency is used, video-rate image acquisition is possible. Homodyne FLIM uses a gain-modulated image intensified charge-coupled device (ICCD) detector, which unfortunately is a major contribution to the noise of the measurement. Here we introduce image analysis for denoising homodyne FLIM data. The denoising routine is fast, improves the extraction of the fluorescence lifetime value(s) and increases the sensitivity and fluorescence lifetime resolving power of the FLIM instrument. The spatial resolution (especially the high spatial frequencies not related to noise) of the FLIM image is preserved, because the denoising routine does not blur or smooth the image. By eliminating the random noise known to be specific to photon noise and from the intensifier amplification, the fidelity of the spatial resolution is improved. The polar plot projection, a rapid FLIM analysis method, is used to demonstrate the effectiveness of the denoising routine with exemplary data from both physical and complex biological samples. We also suggest broader impacts of the image analysis for other fluorescence microscopy techniques (e.g. super-resolution imaging).  相似文献   

9.
The deconvolution of fluorescence lifetime imaging microscopy (FLIM) data that were processed with global analysis techniques is described. Global analysis of FLIM data enables the determination of relative numbers of molecules in different protein reaction states on a pixel-by-pixel basis in cells. The three-dimensional fluorescence distributions of each protein state can then be calculated and deconvolved. High-resolution maps of the relative concentrations of each state are then obtained from the deconvolved images. We applied these techniques to quantitatively image the phosphorylation state of ErbB1 receptors tagged with green fluorescent protein in MCF7 cells.  相似文献   

10.
The utility of fluorescence lifetime imaging microscopy (FLIM) for identifying bacteria in complex mineral matrices was investigated. Baseline signals from unlabelled Bacillus subtilis and Euglena gracilis, and Bacillus subtilis labelled with SYTO 9 were obtained using two-photon excitation at 730, 750 and 800 nm, identifying characteristic lifetimes of photosynthetic pigments, unpigmented cellular autofluorescence, and SYTO 9. Labelled and unlabelled B. subtilis were seeded onto marble and gypsum samples containing endolithic photosynthetic cyanobacteria and the ability to distinguish cells from mineral autofluorescence and nonspecific dye staining was examined in parallel with ordinary multichannel confocal imaging. It was found that FLIM enabled discrimination of SYTO 9 labelled cells from background, but that the lifetime of SYTO 9 was shorter in cells on minerals than in pure culture under our conditions. Photosynthetic microorganisms were easily observed using both FLIM and confocal. Unlabelled, nonpigmented bacteria showed weak signals that were difficult to distinguish from background when minerals were present, though cellular autofluorescence consistent with NAD(P)H could be seen in pure cultures, and phasor analysis permitted detection on rocks. Gypsum and marble samples showed similar autofluorescence profiles, with little autofluorescence in the yellow-to-red range. Lifetime or time-gated imaging may prove a useful tool for environmental microbiology. LAY DESCRIPTION : The standard method of bacterial enumeration is to label the cells with a fluorescent dye and count them under high-power fluorescence microscopy. However, this can be difficult when the cells are embedded in soil and rock due to fluorescence from the surrounding minerals and dye binding to ambiguous features of the substrate. The use of fluorescence lifetime imaging (FLIM) can disambiguate these signals and allow for improved detection of bacteria in environmental samples.  相似文献   

11.
Photon counting detectors currently used in fluorescence lifetime microscopy have a number of deficiencies that result in less‐than‐ideal signal‐to‐noise ratio of the lifetimes obtained: Either the quantum efficiency is unsatisfactory or the active area is too small, and afterpulsing or tails in the temporal response contribute to overall timing inaccuracy. We have therefore developed a new FLIM detector based on a GaAsP hybrid photomultiplier. Compared with conventional PMTs and SPADs, GaAsP hybrid detectors have a number of advantages: The detection quantum efficiency reaches or surpasses the efficiency of fast SPADs, and the active area is on the order of 5 mm2, compared with 2.5 10?3 mm2 for a SPAD. The TCSPC response is clean, without the bumps and the diffusion tails typical for PMTs and SPADs. Most important, the hybrid detector is intrinsically free of afterpulsing. FLIM results are therefore free of signal‐dependent background, and FCS curves are free of the known afterpulsing peak. We demonstrate the performance of the new detector for multiphoton NDD FLIM and for FCS. Microsc. Res. Tech., 2011. © 2010 Wiley‐Liss, Inc.  相似文献   

12.
A scanning microscope utilizing two-photon excitation in combination with fluorescence lifetime contrast is presented. The microscope makes use of a tunable femtosecond titanium:sapphire laser enabling the two-photon excitation of a broad range of fluorescent molecules, including UV probes. Importantly, the penetration depth of the two-photon exciting (infra)red light is substantially greater than for the corresponding single-photon wavelength while photobleaching is significantly reduced. The time structure of the Ti:Sa laser can be employed in a straightforward way for the realization of fluorescence lifetime imaging. The fluorescence lifetime is sensitive to the local environment of the fluorescent molecule. This behaviour can be used for example to quantify concentrations of ions, such as pH and Ca2+, or pO2 and pCO2. In the set-up presented here the fluorescence lifetime imaging is accomplished by time-gated single photon counting. The performance and optical properties of the microscope are investigated by a number of test measurements on fluorescent test beads. Point-spread functions calculated from measurements on 230-nm beads using an iterative restoration procedure compare well with theoretical expectations. Lifetime imaging experiments on a test target containing two different types of test bead in a fluorescent buffer all with different lifetimes (2.15 ns, 2.56 ns and 3.34 ns) show excellent quantitative agreement with reference values obtained from time correlated single photon counting measurements. Moreover, the standard deviation in the results can be wholly ascribed to the photon statistics. Measurements of acridine orange stained biofilms are presented as an example of the potential of two-photon excitation combined with fluorescence lifetime contrast. Fluorescence lifetime and intensity images were recorded over the whole sample depth of 100 μm. Fluorescence intensity imaging is seriously hampered by the rapid decrease of the fluorescence signal as a function of the depth into the sample. Fluorescence lifetime imaging on the other hand is not affected by the decrease of the fluorescence intensity.  相似文献   

13.
The real-time uptake of serotonin, a neurotransmitter, by rat leukemia mast cell line RBL-2H3 and 5-hydroxytryptophan by Chinese hamster V79 cells has been studied by fluorescence lifetime imaging microscopy (FLIM), monitoring ultraviolet (340 nm) fluorescence induced by two-photon subpicosecond 630 nm excitation. Comparison with two-photon excitation with 590 nm photons or by three-photon excitation at 740 nm shows that the use of 630 nm excitation provides optimal signal intensity and lowered background from auto-fluorescence of other cellular components. In intact cells, we observe using FLIM three distinct fluorescence lifetimes of serotonin and 5-hydroxytryptophan according to location. The normal fluorescence lifetimes of both serotonin (3.8 ns) and 5-hydroxytryptophan (3.5 ns) in solution are reduced to approximately 2.5 ns immediately on uptake into the cell cytosol. The lifetime of internalized serotonin in RBL-2H3 cells is further reduced to approximately 2.0 ns when stored within secretory vesicles.  相似文献   

14.
In this work, we characterized streptavidin-conjugated quantum dots (QDs) manufactured by Quantum Dot Corporation. We present data on: (1) two-photon excitation; (2) fluorescence lifetimes; (3) ensemble and single QD emission anisotropy; (4) QDs as donors for Forster resonance energy transfer (FRET); and (5) spectral conversion of QDs exposed to high-intensity illumination. We also demonstrate the utility of QDs for (1) imaging the binding and uptake of biotinylated transferrin on living cells, and (2) resolving by fluorescence lifetime imaging microscopy (FLIM) signals originating from QDs from those of spatially and spectrally overlapping visible fluorescent proteins (VFPs).  相似文献   

15.
Fluorescence lifetime imaging (FLIM) uses the fact that the fluorescence lifetime of a fluorophore depends on its molecular environment but not on its concentration. Molecular effects in a sample can therefore be investigated independently of the variable, and usually unknown concentration of the fluorophore. There is a variety of technical solutions of lifetime imaging in microscopy. The technical part of this paper focuses on time‐domain FLIM by multidimensional time‐correlated single photon counting, time‐domain FLIM by gated image intensifiers, frequency‐domain FLIM by gain‐modulated image intensifiers, and frequency‐domain FLIM by gain‐modulated photomultipliers. The application part describes the most frequent FLIM applications: Measurement of molecular environment parameters, protein‐interaction measurements by Förster resonance energy transfer (FRET), and measurements of the metabolic state of cells and tissue via their autofluorescence. Measurements of local environment parameters are based on lifetime changes induced by fluorescence quenching or conformation changes of the fluorophores. The advantage over intensity‐based measurements is that no special ratiometric fluorophores are needed. Therefore, a much wider selection of fluorescence markers can be used, and a wider range of cell parameters is accessible. FLIM‐FRET measures the change in the decay function of the FRET donor on interaction with an acceptor. FLIM‐based FRET measurement does not have to cope with problems like donor bleedthrough or directly excited acceptor fluorescence. This relaxes the requirements to the absorption and emission spectra of the donors and acceptors used. Moreover, FLIM‐FRET measurements are able to distinguish interacting and noninteracting fractions of the donor, and thus obtain independent information about distances and interacting and noninteracting protein fractions. This is information not accessible by steady‐state FRET techniques. Autofluorescence FLIM exploits changes in the decay parameters of endogenous fluorophores with the metabolic state of the cells or the tissue. By resolving changes in the binding, conformation, and composition of biologically relevant compounds FLIM delivers information not accessible by steady‐state fluorescence techniques.  相似文献   

16.
A whole-field time-domain fluorescence lifetime imaging (FLIM) microscope with the capability to perform optical sectioning is described. The excitation source is a mode-locked Ti:Sapphire laser that is regeneratively amplified and frequency doubled to 415 nm. Time-gated fluorescence intensity images at increasing delays after excitation are acquired using a gated microchannel plate image intensifier combined with an intensified CCD camera. By fitting a single or multiple exponential decay to each pixel in the field of view of the time-gated images, 2-D FLIM maps are obtained for each component of the fluorescence lifetime. This FLIM instrument was demonstrated to exhibit a temporal discrimination of better than 10 ps. It has been applied to chemically specific imaging, quantitative imaging of concentration ratios of mixed fluorophores and quantitative imaging of perturbations to fluorophore environment. Initially, standard fluorescent dyes were studied and then this FLIM microscope was applied to the imaging of biological tissue, successfully contrasting different tissues and different states of tissue using autofluorescence. To demonstrate the potential for real-world applications, the FLIM microscope has been configured using potentially compact, portable and low cost all-solid-state diode-pumped laser technology. Whole-field FLIM with optical sectioning (3D FLIM) has been realized using a structured illumination technique.  相似文献   

17.
Multimode fluorescence resonance energy transfer (FRET) microscopy was applied to study the plasma membrane organization using different lipidated green fluorescent protein (GFP)‐fusion proteins co‐expressed in cowpea protoplasts. Cyan fluorescent protein (CFP) was fused to the hyper variable region of a small maize GTPase (ROP7) and yellow fluorescent protein (YFP) was fused to the N‐myristoylation motif of the calcium‐dependent protein kinase 1 (LeCPK1) of tomato. Upon co‐expressing in cowpea protoplasts a perfect co‐localization at the plasma membrane of the constructs was observed. Acceptor‐photobleaching FRET microscopy indicated a FRET efficiency of 58% in protoplasts co‐expressing CFP‐Zm7hvr and myrLeCPK1‐YFP, whereas no FRET was apparent in protoplasts co‐expressing CFP‐Zm7hvr and YFP. Fluorescence spectral imaging microscopy (FSPIM) revealed, upon excitation at 435 nm, strong YFP emission in the fluorescence spectra of the protoplasts expressing CFP‐Zm7hvr and myrLeCPK1‐YFP. Also, fluorescence lifetime imaging microscopy (FLIM) analysis indicated FRET because the CFP fluorescence lifetime of CFP‐Zm7hvr was reduced in the presence of myrLeCPK1‐YFP. A FRET fluorescence recovery after photobleaching (FRAP) analysis on a partially acceptor‐bleached protoplast co‐expressing CFP‐Zm7hvr and myrLeCPK1‐YFP revealed slow requenching of the CFP fluorescence in the acceptor‐bleached area upon diffusion of unbleached acceptors into this area. The slow exchange of myrLeCPK1‐YFP in the complex with CFP‐Zm7hvr reflects a relatively high stability of the complex. Together, the FRET data suggest the existence of plasma membrane lipid microdomains in cowpea protoplasts.  相似文献   

18.
Fluorescence lifetime‐resolved images of chlorophyll fluorescence were acquired at the maximum P‐level and during the slower transient (up to 250 s, including P‐S‐M‐T) in the green photosynthetic alga Chlamydomonas reinhardtii. At the P‐level, wild type and the violaxanthin‐accumulating mutant npq1 show similar fluorescence intensity and fluorescence lifetime‐resolved images. The zeaxanthin‐accumulating mutant npq2 displays reduced fluorescence intensity at the P‐level (about 25–35% less) and corresponding lifetime‐resolved frequency domain phase and modulation values compared to wild type/npq1. A two‐component analysis of possible lifetime compositions shows that the reduction of the fluorescence intensity can be interpreted as an increase in the fraction of a short lifetime component. This supports the important photoprotection function of zeaxanthin in photosynthetic samples, and is consistent with the notion of a ‘dimmer switch’. Similar, but quantitatively different, behaviour was observed in the intensity and fluorescence lifetime‐resolved imaging measurements for cells that were treated with the electron transport inhibitor 3‐(3,4‐dichlorophenyl)‐1,1‐dimethyl urea, the efficient PSI electron acceptor methyl viologen and the protonophore nigericin and. Lower fluorescence intensities and lifetimes were observed for all npq2 mutant samples at the P‐level and during the slow fluorescence transient, compared to wild type and the npq1 mutant. The fluorescence lifetime‐resolved measurements during the slow fluorescence changes after the P level up to 250 s for the wild type and the two mutants, in the presence and absence of the above inhibitors, were analyzed with a graphical procedure (polar plots) to determine lifetime compositions. At higher illumination intensity, wild type and npq1 cells show a rise in fluorescence intensity and corresponding rise in the species concentration of the slow lifetime component after the initial decrease following the P level. This reversal is absent in the npq2 mutant, and for all samples in the presence of the inhibitors. Lifetime heterogeneities were observed in experiments averaged over multiple cells as well as within single cells, and these were followed over time. Cells in the resting state (induced by several hours of darkness), instead of the normal swimming state, show shortened lifetimes. The above results are discussed in terms of a superposition of effects on electron transfer and protonation rates, on the so‐called ‘State Transitions’, and on non‐photochemical quenching. Our data indicate two major populations of chlorophyll a molecules, defined by two ‘lifetime pools’ centred on slower and faster fluorescence lifetimes.  相似文献   

19.
Fluorescent protein-based FRET is a powerful method for visualizing protein-protein interactions and biochemical reactions in living cells. It can be difficult, however, to avoid photobleaching when observing fluorescent cells under the microscope, especially those expressing CFP. We compared the sensitivity of two protein-based FRET pairs to light-induced fluorescence changes in the donor, on FRET determination by fluorescence lifetime imaging microscopy (FLIM). Thanks to the very low excitation light levels of the time- and space-correlated single photon counting (TSCSPC) method, FLIM acquisitions were achieved without donor photobleaching. Here, we show that photobleaching of CFP by a mercury lamp under the microscope induced a decrease in the mean fluorescence lifetime, which interfered with FRET determination between CFP and YFP. Importantly, the range of light-induced variation of the mean fluorescence lifetime of CFP was not proportional to the decrease in the steady state fluorescence intensity and varied from cell to cell. The choice of the CFP/YFP pair therefore requires that the cells be observed and analyzed at very low light levels during the whole FRET experiment. In contrast, the GFP/mCherry pair provided an accurate FRET measurement by FLIM, even if some GFP photobleaching took place. We thus demonstrate that CFP can be an unreliable donor for FRET determination in living cells, due to its photosensitivity properties. We demonstrate that the GFP/mCherry pair is better suited for FRET measurement by FLIM in living cells than the CFP/YFP pair.  相似文献   

20.
Imaging FRET standards by steady-state fluorescence and lifetime methods   总被引:1,自引:0,他引:1  
Imaging fluorescence resonance energy transfer (FRET) between molecules labeled with fluorescent proteins is emerging as a powerful tool to study changes in ions, ligands, and molecular interactions in their physiological cellular environment. Different methods use either steady-state fluorescence properties or lifetime to quantify the FRET rate. In addition, some provide the absolute FRET efficiency whereas others are simply a relative index very much influenced by the actual settings and instrumentation used, which makes the interpretation of a given FRET rate very difficult. The use and exchange of FRET standards in laboratories using these techniques would help to overcome this drawback. We report here the construction and systematic evaluation of FRET standard probes of varying FRET efficiencies. The standards for intramolecular FRET were protein fusions of the cyan and yellow variants of A. victoria green fluorescent protein (ECFP and citrine) joined by short linkers or larger protein spacers, or ECFP tagged with a tetracysteine motif and labeled with the biarsenical fluorochrome, FlAsH. Negative and positive controls of intermolecular FRET were also used. We compared these FRET standards with up to four FRET quantification methods: ratioing of acceptor to donor emission, donor intensity recovery upon acceptor photobleach, sensitized emission after spectral unmixing of raw images, and fluorescence lifetime imaging (FLIM). The latter was obtained with a frequency-domain setup able to provide high quality lifetime images in less than a second, and is thus very well suited for live cell studies. The FRET rates or indexes of the standards were in good agreement regardless of the method used. For the CFP-tetraCys/FlAsH pair, the rate calculated from CFP quenching was faster than that obtained by FLIM.  相似文献   