首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
传统超声成像方法受瑞利准则的约束,难以对缺陷间距小于成像分辨率阈值的多缺陷进行成像。提出了一种基于时域拓扑能量的超声兰姆波成像方法,将逆散射拓扑成像方法中的拓扑渐进过程转换成求解直接声场和伴随声场。然后通过将伴随声场进行时间反转,两个声场将具有在缺陷处聚焦,在非缺陷处不聚焦的特性。将直接声场和伴随声场进行融合,以时域拓扑能量值作为像素值进行成像,从而使表征缺陷的精度较高。建立了缺陷间距小于分辨率阈值的多盲孔缺陷有限元模型,通过“一发多收”的方式激发S0模式和采集缺陷散射信号,并进行时域拓扑能量成像。仿真结果表明:对于多盲孔缺陷,时域拓扑能量成像法能够获得比延时叠加法和时间反转成像法更高的分辨率,并且能在缺陷间距小于成像分辨率阈值时进行成像。  相似文献   

2.
Annular arrays provide a means to achieve enhanced image quality with a limited number of elements. Synthetic-focusing (SF) strategies that rely on beamforming data from individual transmit-to-receive (TR) element pairs provide a means to improve image quality without specialized TR delay electronics. Here, SF strategies are examined in the context of high-frequency ultrasound (>15 MHz) annular arrays composed of five elements, operating at 18 and 38 MHz. Acoustic field simulations are compared with experimental data acquired from wire and anechoic-sphere phantoms, and the values of lateral beamwidth, SNR, contrast-to-noise ratio (CNR), and depth of field (DOF) are compared as a function of depth. In each case, data were acquired for all TR combinations (25 in total) and processed with SF using all 25 TR pairs and SF with the outer receive channels removed one by one. The results show that removing the outer receive channels led to an overall degradation of lateral resolution, an overall decrease in SNR, and did not reduce the DOF, although the DOF profile decreased in amplitude. The CNR was >1 and remained fairly constant as a function of depth, with a slight decrease in CNR for the case with just the central element receiving. The relative changes between the calculated and measured quantities were nearly identical for the 18- and 38-MHz arrays. B-mode images of the anechoic phantom and an in vivo mouse embryo using full SF with 25 TR pairs or reduced TR-pair approaches showed minimal qualitative difference.  相似文献   

3.
Linear approach to axial resolution in elasticity imaging   总被引:2,自引:0,他引:2  
Thus far axial resolution in elasticity imaging has been addressed only empirically. No clear analytical approaches have emerged because the estimator is non-linear in the data, correlation functions are nonstationary, and system responses vary spatially. This paper describes a linear systems approach based on a small-strain impulse approximation that results in the derivation of a local impulse response (LIR) and local modulation transfer function (LMTF). Closed-form solutions for strain LIR are available to provide new insights on the role of instrumentation and processing on axial strain resolution. Novel phantom measurements are generated to validate results. We found that the correlation window determines axial resolution in most practical situations, but that the the same system properties that determine B-mode resolution ultimately limit elasticity imaging.  相似文献   

4.
Gao F  Zhao H  Yamada Y 《Applied optics》2002,41(4):778-791
In the field of diffuse optical tomography (DOT), it is widely accepted that time-resolved (TR) measurement can provide the richest information on photon migration in a turbid medium, such as biological tissue. However, the currently available image reconstruction algorithms for TR DOT are based mostly on the cw component or some featured data types of original temporal profiles, which are related to the solution of a time-independent diffusion equation. Although this methodology can greatly simplify the reconstruction process, it suffers from low spatial resolution and poor quantitativeness owing to the limitation of effectively applicable data types. To improve image quality, it has been argued that exploiting the full TR data is essential. We propose implementation of a DOT algorithm by using full TR data and furthermore a variant algorithm with time slices of TR data to alleviate the computational complexity and enhance noise robustness. Compared with those algorithms where the featured data types are used, our evaluations on the spatial resolution and quantitativeness show that a significant improvement in imaging quality can be achieved when full TR data are used, which convinces the DOT community of the potential advantage of the TR domain over cw and frequency domains.  相似文献   

5.
Zhao H  Gao F  Tanikawa Y  Homma K  Yamada Y 《Applied optics》2005,44(10):1905-1916
We present in vivo images of near-infrared (NIR) diffuse optical tomography (DOT) of human lower legs and forearm to validate the dual functions of a time-resolved (TR) NIR DOT in clinical diagnosis, i.e., to provide anatomical and functional information simultaneously. The NIR DOT system is composed of time-correlated single-photon-counting channels, and the image reconstruction algorithm is based on the modified generalized pulsed spectral technique, which effectively incorporates the TR data with reasonable computation time. The reconstructed scattering images of both the lower legs and the forearm revealed their anatomies, in which the bones were clearly distinguished from the muscles. In the absorption images, some of the blood vessels were observable. In the functional imaging, a subject was requested to do handgripping exercise to stimulate physiological changes in the forearm tissue. The images of oxyhemoglobin, deoxyhemoglobin, and total hemoglobin concentration changes in the forearm were obtained from the differential images of the absorption at three wavelengths between the exercise and the rest states, which were reconstructed with a differential imaging scheme. These images showed increases in both blood volume and oxyhemoglobin concentration in the arteries and simultaneously showed hypoxia in the corresponding muscles. All the results have demonstrated the capability of TR NIR DOT by reconstruction of the absolute images of the scattering and the absorption with a high spatial resolution that finally provided both the anatomical and functional information inside bulky biological tissues.  相似文献   

6.
Based on the extended Huygens–Fresnel integral and the theory of coherence of light field, we have investigated the correlated imaging by using the transverse normalized second-order intensity fluctuation correlation function with partially coherent light radiation. The imaging for a reflected object with relative long distance is determined by the feature of speckle-to-speckle correlation. By using the correlation function, we study the effects of imaging distance, the sizes of object lens and reference lens, the source’s transverse coherent width and its transverse size on the quality of correlated imaging. Numerical results show that the parameters of imaging system and the properties of partially coherent light source have significant influences on the imaging resolution and visibility. For an object lens with large enough diameter, the resolution is determined by the transverse coherent width of light source. On the contrary, it depends on the aperture of object lens. The magnification of the system depends only on the propagation distance. This speckle-to-speckle correlated imaging with unbalanced arms have potential applications in remote sensing due to its unique features.  相似文献   

7.
邱芳  唐雨嘉  崔崤峣  焦阳 《声学技术》2023,42(2):184-191
超声平面波成像是近年来一种应用较广泛的超快速超声成像方法,多角度相干平面波复合(Coherent Plane Wave Compounding,CPWC)成像在不过多损失速率的情况下,提升成像质量。但普通的CPWC方法只是简单复合多个角度延时叠加(Delay and Sum,DAS)后的数据,并未考虑到单个角度内以及多个角度之间数据的相关性。文章提出了一种联合空间与角度的符号相干系数(Angular Spatial Sign Coherence Factor,asSCF)平面波成像方法,将空间符号相干因子和角度符号相干因子创新性地融合到波束合成的过程中,充分考虑信号之间的相关性,旨在提升多角度复合成像质量。进行了仿真实验、仿体实验以及在体组织实验,对asSCF-CPWC方法、单一的符号相干系数法以及传统CPWC方法成像进行对比,结果发现asSCF-CPWC方法具有更好的横向分辨能力和成像对比度。  相似文献   

8.
In ultrasound elasticity imaging, strain decorrelation is a major source of error in displacements estimated using correlation techniques. This error can be significantly decreased by reducing the correlation kernel. Additional gains in signal-to-noise ratio (SNR) are possible by filtering the correlation functions prior to displacement estimation. Tradeoffs between spatial resolution and estimate variance are discussed, and estimation in elasticity imaging is compared to traditional time-delay estimation. Simulations and experiments on gel-based phantoms are presented. The results demonstrate that high resolution, high SNR strain estimates can be computed using small correlation kernels (on the order of the autocorrelation width of the ultrasound signal) and correlation filtering.  相似文献   

9.
High-frame rate ultrasound imaging is necessary to track fast deformation in ultrasound elasticity imaging, but the image quality may be degraded. Previously, we investigated the performance of strain imaging using numerical models of conventional and ultrafast ultrasound imaging techniques. In this paper, we performed experimental studies to quantitatively evaluate the strain images and elasticity maps obtained using conventional and high frame rate ultrasound imaging methods. The experiments were carried out using point target and tissue mimicking phantoms. The experimental results were compared with the results of numerical simulation. Our experimental studies confirm that the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and axial/lateral resolution of the displacement and strain images acquired using high-frame rate ultrasound imaging are slightly lower but comparable with those obtained using conventional imaging. Furthermore, the quality of elasticity images also exhibits similar trends. Thus, high-frame rate ultrasound imaging can be used reliably for static elasticity imaging to capture the internal tissue motion if the frame rate is critical.  相似文献   

10.
Neutron imaging by color center formation in LiF crystals was applied to a sensitivity indicator (SI) as a standard samples for neutron radiography. The SI was exposed to a 5 mm pinhole-collimated thermal neutron beam with an LiF crystal and a neutron imaging plate (NIP) for 120 min in the JRR-3M thermal neutron radiography facility. The image in the LiF crystal was read out using a laser confocal microscope. All gaps were clearly observed in images for both the LiF crystal and the NIP. The experimental results showed that LiF crystals have excellent characteristics as neutron imaging detectors in areas such as high spatial resolution.  相似文献   

11.
Past studies have demonstrated that combined fluorescence and diffuse reflectance spectroscopy can successfully discriminate between normal, tumor core, and tumor margin tissues in the brain. To achieve efficient, real-time surgical resection guidance with optical biopsy, probe-based spectroscopy must be extended to spectral imaging to spatially demarcate the tumor margins. We describe the design and characterization of a combined fluorescence and diffuse reflectance imaging system that uses liquid-crystal tunable filter technology. Experiments were conducted to quantitatively determine the linearity, field of view, spatial and spectral resolution, and wavelength sensitivity of the imaging system. Spectral images were acquired from tissue phantoms, mouse brain in vitro, and human cortex in vivo for functional testing of the system. The spectral imaging system produces measured intensities that are linear with sample emission intensity and integration time and possesses a 1 in. (2.54 cm) field of view for a 7 in. (18 cm) object distance. The spectral resolution is linear with wavelength, and the spatial resolution is pixel-limited. The sensitivity spectra for the imaging system provide a guide for the distribution of total image integration time between wavelengths. Functional tests in vitro demonstrate the capability to spectrally discriminate between brain tissues based on exogenous fluorescence contrast or endogenous tissue composition. In vivo imaging captures adequate fluorescence and diffuse reflectance intensities within a clinically viable 2 min imaging time frame and demonstrates the importance of hemostasis to acquired signal strengths and imaging speed.  相似文献   

12.
Application of mass spectrometry imaging (MS imaging) analysis to single cells was so far restricted either by spatial resolution in the case of matrix-assisted laser desorption/ionization (MALDI) or by mass resolution/mass range in the case of secondary ion mass spectrometry (SIMS). In this study we demonstrate for the first time the combination of high spatial resolution (7 μm pixel), high mass accuracy (<3 ppm rms), and high mass resolution (R = 100?000 at m/z = 200) in the same MS imaging measurement of single cells. HeLa cells were grown directly on indium tin oxide (ITO) coated glass slides. A dedicated sample preparation protocol was developed including fixation with glutaraldehyde and matrix coating with a pneumatic spraying device. Mass spectrometry imaging measurements with 7 μm pixel size were performed with a high resolution atmospheric-pressure matrix-assisted laser desorption/ionization (AP-MALDI) imaging source attached to an Exactive Orbitrap mass spectrometer. Selected ion images were generated with a bin width of Δm/z = ±0.005. Selected ion images and optical fluorescence images of HeLa cells showed excellent correlation. Examples demonstrate that a lower mass resolution and a lower spatial resolution would result in a significant loss of information. High mass accuracy measurements of better than 3 ppm (root-mean-square) under imaging conditions provide confident identification of imaged compounds. Numerous compounds including small metabolites such as adenine, guanine, and cholesterol as well as different lipid classes such as phosphatidylcholine, sphingomyelin, diglycerides, and triglycerides were detected and identified based on a mass spectrum acquired from an individual spot of 7 μm in diameter. These measurements provide molecularly specific images of larger metabolites (phospholipids) in native single cells. The developed method can be used for a wide range of detailed investigations of metabolic changes in single cells.  相似文献   

13.
王梦圆  卓颉  刘雄厚  樊宽  陈哲 《声学技术》2016,35(5):414-420
为验证密集式多输入多输出(Multi-Input Multi-Output,MIMO)声呐高分辨成像算法的有效性,进行了水池实验并获得了期望的高分辨成像结果。首先,将成像算法分为角度维高分辨成像和距离维高分辨成像两种,分别建立了各自的成像处理流程。角度维高分辨成像基于虚拟阵列波束形成算法,距离维高分辨成像基于大带宽信号合成算法。然后,根据两种处理流程选择合适的发射信号和阵型,并据此搭建密集式MIMO声呐高分辨成像平台进行水池实验。最后,通过与传统单输入多输出(Single-Input Multi-Output,SIMO)声呐的成像结果进行对比,证明了MIMO声呐可结合发射信号、阵型和相应的处理流程获得更高的角度分辨率和距离分辨率。  相似文献   

14.
Attenuated total reflection-Fourier transform infrared (ATR-FT-IR) imaging is a very useful tool for capturing chemical images of various materials due to the simple sample preparation and the ability to measure wet samples or samples in an aqueous environment. However, the size of the array detector used for image acquisition is often limited and there is usually a trade off between spatial resolution and the field of view (FOV). The combination of mapping and imaging can be used to acquire images with a larger FOV without sacrificing spatial resolution. Previous attempts have demonstrated this using an infrared microscope and a Germanium hemispherical ATR crystal to achieve images of up to 2.5 mm x 2.5 mm but with varying spatial resolution and depth of penetration across the imaged area. In this paper, we demonstrate a combination of mapping and imaging with a different approach using an external optics housing for large ATR accessories and inverted ATR prisms to achieve ATR-FT-IR images with a large FOV and reasonable spatial resolution. The results have shown that a FOV of 10 mm x 14 mm can be obtained with a spatial resolution of approximately 40-60 microm when using an accessory that gives no magnification. A FOV of 1.3 mm x 1.3 mm can be obtained with spatial resolution of approximately 15-20 microm when using a diamond ATR imaging accessory with 4x magnification. No significant change in image quality such as spatial resolution or depth of penetration has been observed across the whole FOV with this method and the measurement time was approximately 15 minutes for an image consisting of 16 image tiles.  相似文献   

15.
In multiplexed computational imaging schemes, high-resolution images are reconstructed by fusing the information in multiple low-resolution images detected by a two-dimensional array of low-resolution image sensors. The reconstruction procedure assumes a mathematical model for the imaging process that could have generated the low-resolution observations from an unknown high-resolution image. In practical settings, the parameters of the mathematical imaging model are known only approximately and are typically estimated before the reconstruction procedure takes place. Violations to the assumed model, such as inaccurate knowledge of the field of view of the imagers, erroneous estimation of the model parameters, and/or accidental scene or environmental changes can be detrimental to the reconstruction quality, even if they are small in number. We present an adaptive algorithm for robust reconstruction of high-resolution images in multiplexed computational imaging architectures. Using robust M-estimators and incorporating a similarity measure, the proposed scheme adopts an adaptive estimation strategy that effectively deals with violations to the assumed imaging model. Comparisons with nonadaptive reconstruction techniques demonstrate the superior performance of the proposed algorithm in terms of reconstruction quality and robustness.  相似文献   

16.
Haim H  Konforti N  Marom E 《Applied optics》2012,51(14):2739-2746
Present determination of optical imaging systems specifications are based on performance values and modulation transfer function results carried with a 1D resolution template (such as the USAF resolution target or spoke templates). Such a template allows determining image quality, resolution limit, and contrast. Nevertheless, the conventional 1D template does not provide satisfactory results, since most optical imaging systems handle 2D objects for which imaging system response may be different by virtue of some not readily observable spatial frequencies. In this paper we derive and analyze contrast transfer function results obtained with 1D as well as 2D templates.  相似文献   

17.
Computational ghost imaging is a structured-illumination active imager coupled with a single-pixel detector that has potential applications in remote sensing. Here we report on an architecture that acquires the two-dimensional spatial Fourier transform of the target object (which can be inverted to obtain a conventional image). We determine its image signature, resolution, and signal-to-noise ratio in the presence of practical constraints such as atmospheric turbulence, background radiation, and photodetector noise. We consider a bistatic imaging geometry and quantify the resolution impact of nonuniform Kolmogorov-spectrum turbulence along the propagation paths. We show that, in some cases, short-exposure intensity averaging can mitigate atmospheric-turbulence-induced resolution loss. Our analysis reveals some key performance differences between computational ghost imaging and conventional active imaging, and identifies scenarios in which theory predicts that the former will perform better than the latter.  相似文献   

18.
Native tissue imaging at superharmonic frequencies   总被引:3,自引:0,他引:3  
The second harmonic imaging mode has been adapted to image tissue and shown considerable improvements in image quality in several applications compared to the fundamental mode. The improvements were attributed to the effects of wave distortion due to nonlinear propagation in tissue. However, imaging tissue at the second harmonic frequency only has various drawbacks. Because the energy in the second harmonic frequency band is much lower than that in the fundamental frequency band, there must be excellent sensitivity and dynamic range in the receiving system to achieve an acceptable amount of signal-to-noise ratio. To increase the sensitivity, the spectral overlap between the fundamental and the second harmonic has to be diminished, which in return deteriorates the imaging resolution. Consequently, a trade-off is mandatory between resolution and sensitivity. Using simulations and measurements, we show that, at appropriate scanning acoustic settings, higher harmonics are generated in tissue. The higher harmonics represent additional, relevant information for tissue imaging and characterization. An elegant way to take advantage of the higher harmonics and to bring all the information together is to combine and incorporate all the multiple higher harmonics into a single component that we call the superharmonic component. Using a newly developed array transducer having a wide frequency band, B-mode images of a phantom were made in the superharmonic mode transmitting at 1.2 MHz. These images have exceptionally improved clarity and yield a dramatically cleaner and sharper contrast between the different structures being imaged. In addition to increased signal-to-noise ratio, superharmonic imaging shows better contrast and axial resolution as well as acceptable penetration depth.  相似文献   

19.
Recently, adaptive beamforming methods have been successfully applied to medical ultrasound imaging, resulting in significant improvement in image quality compared with non-adaptive delay-and-sum (DAS) beamformers. Most of the adaptive beamformers presented in the ultrasound imaging literature are based on the minimum variance (MV) beamformer which can significantly improve the imaging resolution, although their success in enhancing the contrast has not yet been satisfactory. It is desirable for the beamformer to improve the resolution and contrast at the same time. To this end, in this paper, we have applied the eigenspace-based MV (EIBMV) beamformer to medical ultrasound imaging and have shown a simultaneous improvement in imaging resolution and contrast. EIBMV beamformer utilizes the eigenstructure of the covariance matrix to enhance the performance of the MV beamformer. The weight vector of the EIBMV is found by projecting the MV weight vector onto a vector subspace constructed from the eigenstructure of the covariance matrix. Using EIBMV weights instead of the MV ones leads to reduced sidelobes and improved contrast, without compromising the high resolution of the MV beamformer. In addition, the proposed EIBMV beamformer presents a satisfactory robustness against data misalignment resulting from steering vector errors, outperforming the regularized MV beamformer.  相似文献   

20.
A high-resolution large-area terahertz (THz) scanning imaging system is demonstrated based on a 124×124 pyroelectric array camera and a CO(2) pumped continuous-wave THz laser. By applying a scanning mechanism to the real-time imaging setup, images of large-area targets were accomplished. Self-made resolution charts were employed to test the resolution. In order to improve the image quality, the noise in the images was studied and modeled, and then the performance of several denoising methods was compared with real-time THz original images. The experimental results show that, with the help of anisotropic diffusion, noise can be effectively suppressed, and the results are visually pleasant even when there is great attenuation. Those results greatly confirm application potentials of THz imaging using pyroelectric cameras in the field of concealed object detection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号