1.
结合静电和电容传感技术各自的特点,提出了阵列式静电-电容传感器用于气固两相流中固相颗粒的局部速度、局部浓度以及局部流量测量。利用静电极片阵列与电容极片阵列获取管道内颗粒的速度分布与浓度分布,进而计算出颗粒的局部流量。该阵列式传感器参数测量的准确性直接取决于它的空间灵敏度分布特性。对静电极片阵列和电容极片阵列的灵敏度特性进行了研究。首先,建立了静电极片阵列的三维静电场模型,通过有限元法分析静电极片阵列的结构参数(电极长度、电极覆盖角等)对传感器灵敏度特性的影响;然后根据电磁场理论建立电容极片阵列的数学模型,并对其进行数值计算,研究管道厚度、管道介电常数、电极覆盖角等参数对传感器灵敏度特性的影响;最后搭建了传动带装置进行了实验研究,实验结果证实了模拟结果的准确性,为阵列式静电-电容传感器的优化设计提供理论依据。  相似文献   

2.
The concentration measurement of pulverized coal in a pneumatic pipeline is a challenging issue in power plant. A thermal probe manufactured with abrasion-proof steel was developed for coal concentration measurement in such a situation. The probe generates 15 W of heat. This method is based on the heat transfer between the thermal probe and the gas–solid two-phase flow. Experiments were conducted in a horizontal pneumatic pipeline to assess the accuracy of the thermal probe, where the gas was air and the solid was pulverized coal with mean diameter of 65 µm. The wall temperature of the thermal probe was found to be dependent on both coal powder concentration and air velocity. A new heat transfer correlation was proposed in terms of the modified Reynolds and Nusselt numbers for the gas–solid two-phase flow across the thermal probe. In the range of coal powder concentration from 0.1 to 0.65 kg/kg, the standard deviation is 0.01 kg/kg for the thermal probe. The thermal probe has potential application for concentration measurement of pulverized coal in the pneumatic pipelines of power plants.  相似文献   

3.
气固两相流质量流量测量的新方法   总被引:1,自引:0,他引:1  
文提出了一种采用电容传感器测量气固两相流质量流量的新方法。通过电容传感器对固相浓度的测量,可以求出气固两相流的固气比,结合气固混合之前所测得的载气流量,便可测出固相的质量流量。实测结果显示,测量误差小于5  相似文献   

4.
It is necessary to monitor and balance the pulverized coal velocity and flowrate among the conveying pipelines leading to injection burners and to optimize the air-coal ratio for safety, economical operation, and reduction of pollution of coal-fired boilers in power plants. A novel electrostatic sensing system is reported for monitoring the velocity and relative mass flowrate of pulverized coal. The design, implementation, and on-plant trials of the system are reported. The velocity of pulverized coal was determined by autocorrelating the output derived from a linear electrostatic sensor array. The relative concentration and mass flowrate were obtained by the root mean square values of the output of two ring-shaped electrodes with the consideration of the pulverized coal velocity. The instrumentation was evaluated on a full-scale 600 MW power generation unit. The results demonstrate that the technique provides reliable measurement of pulverized coal velocity, relative flowrate, and split distribution among the injection pipes from the same pulverizing mill. The prototype achieved split balance and optimized air/coal ratio in combination with the pulverized coal balancing control valve and proportional-integral-derivative controller in fuel injection pipes in a power plant.  相似文献   

5.
Two miniaturized liquid film sensors (MLFS) based on electrical conductance measurement have been developed and tested. The sensors are non-intrusive and produced with materials and technologies fully compatible and integrable with standard microfluidics. They consist of a line of 20 electrodes with a purpose-designed shape, flush against the wall, covering a total length of 5.00 and 6.68 mm. The governing electronics achieve 10 kHz of time resolution. The electrode spacing of the two sensors is 230 μm and 330 μm, which allows measurements of liquid films up to 150 μm and 400 μm for sensors MLFSA and MLFSB, respectively. The sensor characteristics were obtained by imposing static liquid films of known thickness on top of the actual sensor. Further dynamic measurements of concurrent air-water flow in a horizontal microchannel were performed. The line of electrodes is placed across the flow direction with an angle of 3.53° from the direction of flow, allowing for a spatial resolution perpendicular to the flow of 14.2 μm for sensor MLFSA and 20.5 μm for sensor MLFSB. The high time and spatial resolution allows for fast and accurate detection of the presence of bubbles, and even measurement of film thickness and bubble velocity. Further information, such as the bubble shape, can be gathered based on the shape of the liquid layer underneath the bubble, which is particularly important for heat transfer studies in microchannels.  相似文献   

6.
Wafer-level characterization of functional prototypes of solid state current sensors is usually the first step in the development stage, therefore a dedicated wafer-level measurement systems are required. Especially for MHz characterization, where electromagnetic interference issues became strongly relevant. Thus, for frequencies above 1 MHz, a sophisticated measurement techniques are needed, because parasitic couplings can significantly affect sensor response and other signal processing stages, causing errors or malfunction of the whole system. We propose technique for high immunity MHz current measurement by solid state sensor in wafer-level configuration. The system is especially well-suited for MHz characterization, where electromagnetic interference issues become highly relevant. We showed that balanced transmission provides possibility to reduce interference in the sensor biasing circuit of about 60 dB compared to single-ended method. The effectiveness of the proposed technique was tested in monitoring MHz current in the external line by single magnetoresistive sensors on wafer level.  相似文献   

7.
We propose a refractive index optical fiber sensor based on the micro cavities generated through the fiber catastrophic fuse effect. This sensor was tested in the measurement of solutions with refractive indices ranging from 1.3320 to 1.4280. The linear dependence of the reflection spectra modulation period as function of the surrounding environment refractive index leads to a resolution of 3 × 10−4 RIU. The proposed sensor is an innovative solution based on optical fiber damaged by the fuse effect, resulting in a cost effective solution.  相似文献   

8.
The design and development of an Abbe-compliant linear encoder-based measurement system for position measurement with a targeted 20 nm uncertainty (k = 2) in machine tools and CMMs is presented. It consists of a linear scale and a capacitive sensor, mounted in line on an interface which is guided in the scale's measurement direction and driven by a linear motor based on the output signal of the capacitive sensor. The capacitive sensor measures the displacement of a target surface on the workpiece table. The functional point, which is the center of a tool or touch probe, is always aligned with the scale and capacitive sensor such that this configuration is compliant with the Abbe principle. Thermal stability is achieved by the application of a thermal center between the scale and capacitive sensor at the tip of the latter, which prevents both components to drift apart. Based on this concept, a prototype of a one-DOF measurement system was developed for a measurement range of 120 mm, together with an experimental setup aimed at verifying the reproducibility of the system for changing ambient conditions of ±0.5 °C and ±5%rh and the repeatability during tracking of a target surface over a short period of time. These experiments have shown that the measurement uncertainty of the one-DOF system is below 29 nm with a 95% confidence level.  相似文献   

9.
Combination of X-ray Digital Industrial Radiography (DIR) and Particle Tracking Velocimetry (PTV) techniques for local liquid velocity measurement (VLL) has been newly developed and successfully applied for trickle bed reactor (TBR). The technique was validated against newly developed fiber optical probe technique. This work attempts to highlight the applicability of this newly developed technique on a liquid–solid packed bed reactor. In this work, liquid was represented by water and solids were represented by EPS beads. The EPS beads were chosen because of its low density property. Three superficial liquid velocities (VSL) were applied to the system. The experiment was replicated four times. The digital industrial radiography (DIR) consists of a complementary metal oxide semiconductor (CMOS) digital detector and X-ray source. Results of this work suggest that the technique has been successfully applied and comparable with previous work that has been done in the literature. It also suggests that there will be a maximum measurable interstitial liquid velocity when it travel inside the packed bed. The measured VLL can have a maximum range that is between 4 and 4.7 times that of its VSL. For VSL=0.42±±2%, the VLL-Max is in between 1.7 cm/s and 1.9 cm/s, VSL=0.84±±2%, the VLL-Max is in between 3.6 cm/s and 4.0 cm/s, and for VSL=1.11±±2%, the VLL-Max is in between 4.3 cm/s and 4.8 cm/s.  相似文献   

10.
A potential step method was used to characterize the electrooxidation of methanol on a chemically modified electrode in an ionic liquid solvent. Two major findings were reported from this study. Firstly, the oxidation was dominant 2.2 s after the potential step. Before that, the double layer charging and adsorption were dominant. Therefore, there should be a waiting time of a few seconds if a methanol sensor is developed with a potential step method. Secondly, the oxidation of methanol on the electrode was diffusion controlled. The concentration of methanol affected the diffusion. The diffusion constant D0 was 8.37 × 10−17 m2/s when the concentration was lower than 0.5 M and was 2.66 × 10−13 m2/s when the concentration was higher than 1.0 M. This suggests that the methanol concentration should be kept higher than a threshold in an ionic liquid based fuel cell.  相似文献   

11.
A simplified technique using short term Fourier transform to reduce the errors in distributed temperature measurement with a Raman scattering based optical fiber sensor system is presented. The two main sources of errors are differential attenuation to anti-Stokes and Stokes signal by fiber and local change in Stokes due to change in temperature. The proposed technique compensates these errors and extracts correct temperature profile in spite of practical difficulties encountered in applying the theoretical concept. Moreover proposed technique is less complex, self-reliant, can tolerate variation in laser power, requires less dead zone and suits automation using embedded solution. Results of measurement carried out, using the system developed at RRCAT, Indore, for two hot zones having spatial width of 1.9 m (kept at 56 °C) and 1.5 m (kept at 78 °C), located at 47 m and 85 m respectively, show that these parameters can be recovered with significantly small errors.  相似文献   

12.
The paper presents an approach toward an enhancement of the measuring range of high-speed sensors for the measurement of liquid film thickness distributions based on electrical conductance. This type of sensors consists of electrodes mounted flush to the wall. The sampling of the current generated between a pair of neighboring electrode is used as a measure of the film thickness. Such sensors have a limited measuring range, which is proportional to the lateral distance between the electrodes. The range is therefore coupled to the spatial resolution. The proposed new design allows an extension of the film thickness range by combining electrode matrices of different resolution in one and the same sensor. In this way, a high spatial resolution is reached with a small thickness range, whereas a film thickness that exceeds the range of the high resolution measurement can still be acquired even though on the costs of a lower spatial resolution. A simultaneous signal acquisition with a sampling frequency of 3.2 kHz combines three measuring ranges for the characterization of a two-dimensional film thickness distribution: (1) thickness range 0–600 µm, lateral resolution 2×2 mm2, (2) thickness range 400–1300 µm, lateral resolution 4×4 mm2, and (3) thickness range 1000–3500 µm, lateral resolution 12×12 mm2. The functionality of this concept sensor is demonstrated by tests in a horizontal wavy stratified air–water flow at ambient conditions. Using flexible printed circuit board technology to manufacture the sensor makes it possible to place the sensor at the inner surface of a circular pipe.  相似文献   

13.
The present paper describes a moving permanent magnet linear synchronous motor (MPM LSM) that can move with an acceleration above 100 G (=980 m/s2), and is also capable of high-precision and high-speed positioning. The MPM LSM consists of a mover including permanent magnets and a double-sided electromagnet stator. It can produce a thrust of 4.56 × 103 N and has a working range wider than 1 m. The MPM LSM mover is improved for light weight and is driven using a suitable phase lead for flux weakening. The combination of the improved mover and the suitable phase lead provides motion at an acceleration above 100 G and a velocity above 12 m/s. The positioning characteristics of the improved MPM LSM are examined using a controller with two suitable phase lead functions. The control system shows a positioning accuracy and a positioning resolution of 500 nm, which is similar to the vibration amplitude of the sensor output in open loop. In 300-mm step positioning, the improved MPM LSM shows an acceleration above 660 m/s2 and a velocity above 8.3 m/s. It takes less than 101 ms to reduce the positioning error to less than 5 μm. The temperature rise during positioning is also examined experimentally. Continuous positioning for longer than 30 minutes increases the temperature of the MPM LSM, but by less than 6 °C.  相似文献   

14.
Prism signal processing is a new recursive FIR technique that facilitates the rapid tracking of sinusoidal signals, such as those used in a Coriolis Mass Flow Meter (CMFM). A Prism-based CMFM prototype has been developed using a commercial flowtube and a dual ARM processor-based transmitter, which is capable of generating flow measurement updates at 48 kHz. This has been applied in a feasibility study to the tracking of fast (e.g. 1.5 ms) injections of diesel fuel on a laboratory rig at engine speeds of up to 4000 rpm equivalent and at fuel pressures of up to 100 MPa. Due to the high level of vibration in the system, Prism-based notch filtering is used to suppress undesired modes of flowtube vibration in the sensor signal. Individual flow pulses can be detected by the system, but the relatively long period of oscillation of the flowtube compared to the fuel injection duration results in a spreading out over time of each flow pulse measurement. More precise measurement results may be obtained using a higher frequency resonant flowtube.  相似文献   

15.
This research investigates the effects of flow pattern and salinity of oil-water two-phase flow on water holdup measurement using a conductance method. Firstly, vertical upward oil-water two-phase flow experiment is conducted in a 20 mm inner diameter (ID) pipe, in which the salinities of aqueous solutions are set as 151 ppm, 1003 ppm, 2494 ppm and 4991 ppm respectively. Experimental water-cut and mixture velocity are set as 80–100% and 0.0184–0.2576 m/s. In the experiment, three different flow patterns, i.e., dispersed oil-in-water slug flow (D OS/W), dispersed oil-in-water flow (D O/W) and very fine dispersed oil-in-water flow (VFD O/W) are observed and recorded by a high speed camera. Meanwhile, we collect the response of Vertical Multiple Electrode Array (VMEA) conductance sensor excited by a sine voltage signal. The result shows that, for VFD O/W, the water holdup from VMEA sensor shows a satisfied agreement with that of quick closing valve (QCV) method under certain salinities, i.e., 1003 ppm as well as 2494 ppm. For D OS/W flow and D O/W flow characterized by dispersed oil droplets with various sizes, considerable deviations of water holdup between VMEA sensor and QCV method under four kinds of salinity aforementioned are presented. Afterward, according to experimental analysis along with theoretical deviation, it is concluded that the deviation of the measurement system reaches its minimum when reference resistance in the measurement circuit and salinity of the aqueous solution satisfy constraint conditions, and the accuracy of water holdup using the conductance method can be improved through adjusting reference resistance to match the salinity of water phase. Finally, the recurrence plot algorithm is utilized to identify typical flow patterns mentioned above and it shows satisfied results on comprehending the discrepancies among different flow patterns, demonstrating that the recurrence plot algorithm can be effectively applied in flow pattern identification regarding oil-water flows.  相似文献   

16.
Industrial applications involving pulsed ultrasound instrumentation require complete non-invasive setups due to high temperatures, pressures and possible abrasive fluids. Recently, new pulser-receiver electronics and a new sensor unit were developed by Flow-Viz. The complete sensor unit setup enables non-invasive Doppler measurements through high grade stainless steel. In this work a non-invasive sensor unit developed for one inch pipes (22.5 mm ID) and two inch pipes (48.4 mm ID) were evaluated. Performance tests were conducted using a Doppler string phantom setup and the Doppler velocity results were compared to the moving string target velocities. Eight different positions along the pipe internal diameter (22.5 mm) were investigated and at each position six speeds (0.1–0.6 m/s) were tested. Error differences ranged from 0.18 to 7.8% for the tested velocity range. The average accuracy of Doppler measurements for the 22.5 mm sensor unit decreased slightly from 1.3 to 2.3% across the ultrasound beam axis. Eleven positions were tested along the diameter of the 48.4 mm pipe (eight positions covered the pipe radius) and five speeds were tested (0.2–0.6 m/s). The average accuracy of Doppler measurements for the 48.4 mm sensor unit was between 2.4 and 5.9%, with the lowest accuracy at the point furthest away from the sensor unit. Error differences varied between 0.07 and 11.85% for the tested velocity range, where mostly overestimated velocities were recorded. This systematic error explains the higher average error difference percentage when comparing the 48.4 mm (2.4–5.9%) and 22.5 mm (1.3–2.3%) sensor unit performance. The overall performance of the combined Flow-Viz system (electronics, software, sensor) was excellent as similar or higher errors were typically reported in the medical field. This study has for the first time validated non-invasive Doppler measurements through high grade stainless steel pipes by using an advanced string phantom setup.  相似文献   

17.
Oil-in-water two-phase flows are often encountered in the upstream petroleum industry. The measurement of phase flow rates is of particular importance for managing oil production and water disposal and/or water reinjection. The complexity of oil-in-water flow structures creates a challenge to flow measurement. This paper proposes a new method of two-phase flow metering, which is based on the use of dual-modality system and multidimensional data fusion. The Electrical Resistance Tomography system (ERT) is used in combination with a commercial off-the-shelf Electromagnetic Flow meter (EMF) to measure the volumetric flow rate of each constituent phase. The water flow rate is determined from the EMF with an input of the mean oil-fraction measured by the ERT. The dispersed oil-phase flow rate is determined from the mean oil-fraction and the mean oil velocity measured by the ERT cross-correlation velocity profiling. Experiments were carried out on a vertical upward oil-in-water pipe flow, 50 mm inner-diameter test section, at different total liquid flow rates covering the range of 8–16 m3/hr. The oil and water flow rate measurements obtained from the ERT and the EMF are compared to their respective references. The accuracy of these measurements is discussed and the capability of the measurement system is assessed.  相似文献   

18.
On-line continuous monitoring of pulverized coal in fuel injection pipes will allow power plant operators to optimize fuel conveying conditions and ultimately to achieve higher combustion efficiency and lower atmospheric emissions. This paper presents the design, implementation and trials of a prototype instrumentation system for the on-line measurement of pulverized coal on a full-scale power plant. An array of three identical arc-shaped electrostatic electrodes is housed in a sensing head to derive particle flow signals. Pulverized coal flow parameters such as velocity, mass flow rate and fuel distribution among the injection pipes from the same pulverizing mill are obtained by processing the signals and fusing the resulting measurements. On-plant demonstration trials on 560 mm bore pneumatic conveying pipes feeding a 600 MW boiler were undertaken following system evaluation tests on a 50 mm bore laboratory test rig. Experimental results demonstrate that reliable monitoring of pulverized coal flow parameters is achieved and that the system is able to track both transient and long-term fluctuations of pulverized coal flow in fuel injection pipes under real power plant conditions.  相似文献   

19.
Within the framework of a research project regarding investigations on a high-pressure Coriolis mass flow meter (CMF) a portable flow test rig for traceable calibration measurements of the flow rate (mass - and volume flow) in a range of 5 g min−1 to 500 g min−1 and in a pressure range of 0.1 MPa to 85 MPa was developed. The measurement principle of the flow test rig is based on the gravimetrical measuring procedure with flying-start-and-stop operating mode. Particular attention has been paid to the challenges of temperature stability during the measurements since the temperature has a direct influence on the viscosity and flow rate of the test medium. For that reason the pipes on the high-pressure side are double-walled and insulated and the device under test (DUT) has an enclosure with a separate temperature control. From the analysis of the first measurement with tap water at a temperature of 20 °C and a pressure of 82.7 MPa an extensive uncertainty analysis has been carried out. It was found that the diverter (mainly due to its asymmetric behaviour) is the largest influence factor on the total uncertainty budget. After a number of improvements, especially concerning the diverter, the flow test rig has currently an expanded measurement uncertainty of around 1.0% in the lower flow rate range (25 g min−1) and 0.25% in the higher flow rate range (400 g min−1) for the measurement of mass flow. Additional calibration measurements with the new, redesigned flow test rig and highly viscous base oils also indicated a good agreement with the theoretical behaviour of the flow meter according to the manufacturers׳ specifications with water as test medium. Further improvements are envisaged in the future in order to focus also on other areas of interest.  相似文献   

20.
The detection of contaminated food in every stage of processing required new technology for fast identification and isolation of toxicity in food. Since effect of food contaminant are severe to human health, the need of pioneer technologies also increasing over last few decades. In the current study, MDA was prepared by hydrolysis of 1,1,3,3-tetramethoxypropane in HCl media and used in the electrochemical studies. The electrochemical sensor was fabricated with modified glassy carbon electrode with polyaniline. These sensors were used for detection of sodium salt of malonaldehyde and observed that a high sensitivity in the concentration range ∼1 × 10−1 M and 1 × 10−2 M. Tafel plots show the variation of over potential from  1.73 V to  3.74 V up to 10−5 mol/L indicating the lower limit of detection of the system.  相似文献   