1.
BACKGROUND: The development of pulsatile ventricular assist devices for children has been limited mainly by size constraints. The purpose of this study was to evaluate the MEDOS trileaflet-valved, pulsatile, pediatric right ventricular assist device (stroke volume = 9 mL) in a neonatal lamb model of acute right ventricular failure. METHODS: Right ventricular failure was induced in ten 3-week-old lambs (8.6 kg) by right ventriculotomy and disruption of the tricuspid valve. Control group 1 (n = 5) had no mechanical support whereas experimental group 2 (n = 5) had right ventricular assist device support for 6 hours. The following hemodynamic parameters were measured in all animals: heart rate and right atrial, pulmonary arterial, left atrial, and systemic arterial pressures. Cardiac output was measured by an electromagnetic flow probe placed on the pulmonary artery. RESULTS: All results are expressed as mean +/- standard deviation and analyzed by Student's t test. A p value less than 0.05 was considered statistically significant. Base-line measurements were not significantly different between groups and included systemic arterial pressure, 80.6 +/- 12.7 mm Hg; right atrial pressure, 4.6 +/- 1.6 mm Hg; mean pulmonary arterial pressure, 15.6 +/- 4.2 mm Hg; left atrial pressure, 4.8 +/- 0.8 mm Hg; and cardiac output, 1.4 +/- 0.2 L/min. Right ventricular injury produced hemodynamics compatible with right ventricular failure in both groups: mean systemic arterial pressure, 38.8 +/- 10.4 mm Hg; right atrial pressure, 16.8 +/- 2.3 mm Hg; left atrial pressure, 1.4 +/- 0.5 mm Hg; and cardiac output, 0.6 +/- 0.1 L/min. All group 1 animals died at a mean of 71.4 +/- 9.4 minutes after the operation. All group 2 animals survived the duration of study. Hemodynamic parameters were recorded at 2, 4, and 6 hours on and off pump, and were significantly improved at all time points: mean systemic arterial pressure, 68.0 +/- 13.0 mm Hg; right atrial pressure, 8.2 +/- 2.3 mm Hg; left atrial pressure, 6.4 +/- 2.1 mm Hg; and cardiac output, 1.0 +/- 0.2 L/min. CONCLUSIONS: The results demonstrate the successful creation of a right ventricular failure model and its salvage by a miniaturized, pulsatile right ventricular assist device. The small size of this device makes its use possible even in small neonates.  相似文献   

2.
Life-threatening, recurrent ventricular tachycardia developed in a 54-year-old heart transplant candidate with ischemic cardiomyopathy. The episodes of ventricular tachycardia were refractory to aggressive medical management and implantable cardiac defibrillator placement. A Heartmate left ventricular assist device was implanted, in combination with isolated right coronary artery bypass grafting, which abolished any further episode of ventricular tachycardia. The patient successfully underwent cardiac transplantation 79 days later.  相似文献   

3.
Eleven infants weighing 2.3 to 7.8 kg underwent mechanical circulatory support for post cardiotomy cardiogenic shock. Initiated pre-operatively in two patients, extracorporeal membrane oxygenation was used in a total of eight patients aged 6 days to 3 months in association with repair of cyanotic congenital heart disease with increased pulmonary blood flow or with a right sided obstructive lesion. Ventricular assist devices were used in three other patients: a centrifugal left ventricular assist device in Patient 1 (10 months, 5.7 kg) after repair of the anomalous left coronary artery, and a pneumatic biventricular assist device (stroke volume 12 ml) in Patient 2 (6 months, 7.0 kg) for cardiac arrest after closure of ventricular septal defect and in Patient 3 (10 months, 7.8 kg) for post transplant graft failure. Duration of extracorporeal membrane oxygenation duration ranged from 26 to 192 hr (mean, 88 hr). Three patients were weaned from extracorporeal membrane oxygenation and two survived. Two others were separated from extracorporeal membrane oxygenation because of bleeding, but both subsequently died. Patient 1 was weaned from the left ventricular assist device after 192 hr and discharged from the hospital. Support was discontinued after 45 hr in Patient 2 who exhibited irreversible brain damage. Patient 3 was weaned from a biventricular assist device after 174 hr, but suffered recurrent graft failure. Our results show that an appropriate circulatory support system should be selected according to the cardiac anatomy in infants.  相似文献   

4.
Recently it has been shown that inhaled nitric oxide (NO), which has been proven to contribute to improvement in critical pulmonary hypertension, may provide a favorable effect early after left ventricular assist device (LVAD) support. To improve right ventricular function, inhalation of NO was added to treatment with conventional catecholamines for four consecutive dilated cardiomyopathy (DCM) patients following institution of LVAD. In two patients 1 hr after inhalation of NO, central venous pressure (CVP), mean pulmonary arterial pressure (PAm), and pulmonary vascular resistance (PVR) were improved. These results led to better LVAD output and resulted in an adequate cardiac index. On the other hand, a right VAD (RVAD) was implemented in one patient whose high CVP, PAm, and PVR continued; he was weaned after 8 days of RVAD support. Another patient who had a high CVP but normal PAm and PVR before and after inhalation of NO had no improvement in his hemodynamic state. These data suggest that inhaled NO may improve systemic circulation by reducing right ventricular afterload and may become a promising and convenient therapy before placing RVAD in DCM patients under LVAD support. RVAD should be conducted in patients with right ventricular failure or when pulmonary hypertension is associated with impaired right ventricular reserve, even after inhalation of NO.  相似文献   

5.
An intracorporeal left ventricular assist device was placed as a bridge to cardiac transplantation in a 51-year-old man after an acute myocardial infarction. After 126 days of support, the left ventricular assist device malfunctioned. The pump, which had a tear in its pneumatic drive line, was successfully replaced.  相似文献   

6.
A 14-year-old girl with congenital heart disease underwent ventricular assist device placement before cardiac transplantation. The inability to close her abdominal fascia necessitated the placement of Prolene mesh, which subsequently became exposed and contaminated when her incision dehisced. Stable closure was obtained with Vicryl mesh and a rectus abdominis turnover flap. Her posttransplant course was notable for compression of the donor heart, necessitating prolonged open sternotomy. She failed an attempt at delayed sternal closure due to compression of the right ventricle by the sternum. In addition to standard pectoralis advancement flaps, a pedicled osseous sternal flap based on her left internal mammary artery was developed to avoid ventricular compression yet still provide some protection to the mediastinum. Alternative uses of this vascularized bone flap to assist with chest wall reconstruction are discussed.  相似文献   

7.
OBJECTIVES: We studied the effects of left ventricular (LV) unloading by an implantable ventricular assist device on LV diastolic filling. BACKGROUND: Although many investigators have reported reliable systemic and peripheral circulatory support with implantable LV assist devices, little is known about their effect on cardiac performance. METHODS: Peak velocities of early diastolic filling, late diastolic filling, late to early filling ratio, deceleration time of early filling, diastolic filling period and atrial filling fraction were measured by intraoperative transesophageal Doppler echocardiography before and after insertion of an LV assist device in eight patients. A numerical model was developed to simulate this situation. RESULTS: Before device insertion, all patients showed either a restrictive or a monophasic transmitral flow pattern. After device insertion, transmitral flow showed rapid beat to beat variation in each patient, from abnormal relaxation to restrictive patterns. However, when the average values obtained from 10 consecutive beats were considered, overall filling was significantly normalized from baseline, with early filling velocity falling from 87 +/- 31 to 64 +/- 26 cm/s (p < 0.01) and late filling velocity rising from 8 +/- 11 to 32 +/- 23 cm/s (p < 0.05), resulting in an increase in the late to early filling ratio from 0.13 +/- 0.18 to 0.59 +/- 0.38 (p < 0.01) and a rise in the atrial filling fraction from 8 +/- 10% to 26 +/- 17% (p < 0.01). The deceleration time (from 112 +/- 40 to 160 +/- 44 ms, p < 0.05) and the filling period corrected by the RR interval (from 39 +/- 8% to 54 +/- 10%, p < 0.005) were also significantly prolonged. In the computer model, asynchronous LV assistance produced significant beat to beat variation in filling indexes, but overall a normalization of deceleration time as well as other variables. CONCLUSIONS: With LV assistance, transmitral flow showed rapidly varying patterns beat by beat in each patient, but overall diastolic filling tended to normalize with an increase of atrial contribution to the filling. Because of the variable nature of the transmitral flow pattern with the assist device, the timing of the device cycle must be considered when inferring diastolic function from transmitral flow pattern.  相似文献   

8.
Ventricular interdependence is important for the successful use of a left ventricular assist device (LVAD) because the filling of the device depends on right ventricular (RV) function as well as the interactions between the ventricles. The pulmonary arterial (PAP) and systemic arterial (AP) response to inferior vena caval (IVC) occlusion before and after insertion of an LVAD in 15 patients was used to "dissect out" the determinants of these interactions. PAP and AP were recorded during each IVC occlusion and peak systolic values calculated for each beat. Linear regression analysis was used to calculate the slope (k) between peak systolic AP values and peak systolic PAP values. k, a measure of preload responsiveness of the heart, is predominantly linear. k is relatively "flat" in selected LV failure patients pre-LVAD but increases significantly (P < 0.001) after LVAD (0.67 +/- 0.55 vs. 2.71 +/- 1.39). The increase in this parameter after LVAD suggests that the loss of RV-to-LV ventricular interdependence in patients with congestive heart failure appears to recover somewhat once an LVAD is inserted.  相似文献   

9.
A 19-year-old man who had fulminant heart failure caused by an idiopathic dilated cardiomyopathy was supported with a left ventricular assist device for 183 days as a bridge to heart transplantation. At the time of intended transplantation it was noted that the patient's heart had returned to normal size, had a normal ejection fraction, and was able to maintain normal pressures and flows. In view of the apparent recovery of cardiac properties, the left ventricular assist device was explanted and the transplantation was not performed. However, the heart dilated, ejection fraction worsened, and the patient died of heart failure exacerbated acutely by a systemic viral illness. Although such recovery of systolic function is uncommon, as use of the left ventricular assist devices becomes more widespread other physicians might encounter similar findings and, in this regard, they might find our experience useful as they contemplate their treatment options.  相似文献   

10.
Experiments were designed to assess the performance of an intracorporeal (abdominal) left ventricular assist device (ALVAD) in the presence of induced tachycardias, multiple premature ventricular contractions (PVC's), and ventricular fibrillation in calves. Performance criteria were the degree of left ventricular unloading and the per cent cardiac output assumed by the ALVAD. During synchronous pumping, left ventricular unloading was complete and the entire cardiac output was captured by the device. During induced tachycardias up to rates of 120 beats per minute, these degrees of performance were maintained. At rates in excess of 120 beats per minute, performance declined due to decreased biologic stroke volumes and prosthetic filling times. In the presence of induced PVC's, performance during synchronous pumping decreased because of erratic R-wave sensing. Left ventricular unloading was complete but irregular, and the total cardiac output was captured. When asynchronous pumping was utilized, mean left ventricular systolic pressures increased, but total cardiac output was still captured. During induced ventricular fibrillation, ALVAD actuation maintained cardiac outputs equal to control values for periods up to 5 1/2 hours. These experiments indicate that, during normal sinus rhythm, synchronous pumping is optimal; asynchronous pumping is optimal during complex dysrhythmias; and either can be utilized to support the circulation with varying degrees of left ventricular unloading.  相似文献   

11.
To evaluate hemodynamic effectiveness and physiologic changes on the HeartMate 1000 IP left ventricular assist device (Thermo Cardiosystems, Inc., Woburn, Mass.), we studied 25 patients undergoing bridge to heart transplantation (35 to 63 years old, mean 50 years). All were receiving inotropic agents before left ventricular assist device implantation, 21 (84%) were supported with a balloon pump, and 7 (28%) were supported by extracorporeal membrane oxygenation. Six patients died, primarily of right ventricular dysfunction and multiple organ failure. Nineteen (76%) were rehabilitated, received a donor heart, and were discharged (100% survival after transplantation). Pretransplantation duration of support averaged 76 days (22 to 153 days). No thromboembolic events occurred in more than 1500 patient-days of support with only antiplatelet medications. Significant hemodynamic improvement was measured (before implantation to before explantation) in cardiac index (1.7 +/- 0.3 to 3.1 +/- 0.8 L/min per square meter; p < 0.001), left atrial pressure (23.7 +/- 7 to 9 +/- 7.5 mm Hg; p < 0.001), pulmonary artery pressure, pulmonary vascular resistance, and right ventricular volumes and ejection fraction. Both creatinine and blood urea nitrogen levels were significantly higher before implantation in patients who died while receiving support. Renal and liver function returned to normal before transplantation. We conclude that support with the HeartMate device improved hemodynamic and subsystem function before transplantation. Long-term support with the HeartMate device has a low risk of thromboemboli and makes a clinical trial of a portable HeartMate device a realistic alternative to medical therapy.  相似文献   

12.
BACKGROUND: Right ventricular failure can lead to circulatory collapse while on left ventricular assist device support. By shunting blood from the femoral vein to the left ventricular assist device, cardiac output can be increased, but arterial oxygen saturation will decrease. METHODS: To determine the effects on O2 delivery, a model was developed on the basis of O2 uptake in the lungs and whole body O2 consumption. An equation was derived that related cardiac output, pulmonary venous O2 saturation, O2 consumption, and the ratio of shunt-to-systemic blood flow to systemic O2 delivery. RESULTS: When total cardiac output increases, the shunt will increase systemic O2 delivery while decreasing arterial O2 saturation and leaving systemic venous O2 saturation unaltered. When total output does not increase, the shunt will decrease systemic O2 delivery, arterial O2 saturation, and systemic venous O2 saturation. CONCLUSIONS: The analysis suggests that measuring systemic venous oxygen saturation may be a useful way to monitor patient safety. A decrease in systemic venous O2 saturation when creating the shunt implies an inadequate increase in cardiac output.  相似文献   

13.
Right ventricular (RV) function is a limiting factor in maintaining systemic circulation with circulatory assist. There is, however, no easy way to institute RV assist, such as the intraarterial axial flow pump (Hemopump) used for left heart assist. In this study, the feasibility and hemodynamic effect of intravenous use of an axial flow pump was examined. A pump system was developed with an outflow cannula and an impeller that were newly designed for intravenous insertion with a Hemopump driving system. The pump system characteristics using goat blood at a hematocrit of 26% indicated that maximum flow at a pressure differential against 40 mmHg is 3.2 l/min at a pump speed of 28,000 rpm. The pump was tested in adult goats by intravenous insertion through a 14 mm, low porosity graft anastomosed to the infrarenal inferior vena cava. The pump was advanced until the tip of the cannula was positioned at the main pulmonary artery, using balloon catheter guidance under fluoroscopy. RV assistance was evaluated by pressure tracing, and aortic flow (AF) measured by electromagnetic flowmeter under 1) induced pulmonary stenosis (PS), and 2) electrically induced ventricular fibrillation (VF) in combination with left heart assist. Under PS, right atrial pressure decreased from 11 to 2 mmHg and AF increased from 1.0 to 4.1 l/min after initiation of the pump. Under VF, AF and aortic pressure were 2.6 l/min and 78 mmHg, respectively, with left ventricular assist. After initiation of the pump, they increased to 4.0 l/min and 98 mmHg, respectively. In chronic experiments using three adults goats for up to 48 hr, levels of plasma hemoglobin and platelet counts were maintained within an acceptable range. There was no prominent damage to the hearts. These data suggest that an axial flow pump introduced by an intravenous approach without thoracotomy is feasible and provides sufficient right heart assist.  相似文献   

14.
A coronary artery dissection is a rare but well-known lethal complication associated with coronary perfusion. We herein report the case of a right coronary dissection that occurred after an aortic valve replacement. Coronary bypass grafting was successful after the establishment of mechanical biventricular support with an intra-aortic balloon pump and a right ventricular assist device.  相似文献   

15.
Complement activity and platelet glycoprotein (GP) IIb/IIIa dysfunction have been demonstrated during in vitro ventricular assist device circulation. Platelets contain C1 serine protease inhibitor (C1 INH) in secretory granules, which normally regulates complement. Complement activity may result from a loss of platelet regulation on complement during ventricular assist device circulation as platelets lose viability. The purpose of this study was to assess the ability of a platelet GP IIb/IIIa receptor inhibitor to attenuate ventricular assist device associated complement activation during in vitro ventricular assisted circulation. Eight in vitro nonpulsatile centrifugal ventricular assist device circuits were simulated for 4 days using 450 ml fresh human whole blood. Cardiac index, temperature, pH, PO2, PCO2, Ca, glucose, and activated clotting time were maintained at physiologic levels. Levels of C1 INH and C3a were measured with and without a reversible glycoprotein IIb/IIIa inhibitor (MK-383). Concentrations of C1 INH increase on exposure to ventricular assist device, and decrease to a plateau within 12 hr. The decrease in circulating unbound C1 INH was attenuated with pre treatment with MK-383. Concentrations of C3a increase 34 fold within 4 hr of exposure to a ventricular assist device with and 22 fold without pre treatment with MK-383. These findings suggest that protection of the platelet GP IIb/IIIa complex delays complement activation during in vitro ventricular assist device circulation.  相似文献   

16.
BACKGROUND: Implantation of a mechanical cardiac support system (MCSS) in patients with idiopathic dilated cardiomyopathy (IDC) may improve cardiac function and allow explantation of the device. Our experience now includes 13 patients who have been "weaned" from MCSS and we report about the overall results of this treatment as well as the effects of ventricular unloading on cardiac function, anti-beta 1-adrenoceptor-autoantibody (A-beta 1-AAB) level and the degree of myocardial fibrosis. METHODS: 13 patients with non-ischemic IDC who had been admitted here in cardiogenic shock (CI < 1.61.min-1.m2, left ventricular ejection fraction [LVEF] < 16% and left ventricular internal diameter in diastole [LVIDd] > 68 mm) and who all tested positive for A-beta 1-AABs were implanted with an uni-(12 patients) or a biventricular (1 patient) mechanical assist device. Echocardiographic evaluation and A-beta 1-AAB-level-monitoring was routinely performed after implantation and explantation of the MCSS and the degree of myocardial fibrosis was assessed at the time of implantation and after explantation. RESULTS: During a mean duration of mechanical support of 236 +/- 201 days (range: 30 to 794 days), LV-EF improved to a mean of 46% and LVIDd decreased to a mean value of 56 mm in these 13 patients. A-beta 1-AABs decreased and disappeared 11.7 weeks after implantation of the device and did not reincrease thereafter. The highly pathologic degree of fibrosis at the time of implantation diminished to normal values about 1 year after explantation. One patient died of anesthesiologic complications and another patient shortly presented with a new episode of cardiac insufficiency 6 months after explantation. He was implanted again with an univentricular assist device was successfully transplanted 3 weeks later. Mean observation period of the remaining 11 patients now amounts to 12.6 +/- 9.77 (range: 3 to 26) months after explantation of the device--as of May, 31, 1997--with a cumulative observation period of 139 patient months. CONCLUSION: Temporary implantation of a MCSS may normalize cardiac function in selected patients with IDC. The striking degree of myocardial fibrosis can reduce to normal values after explantation of the device. A-beta 1-AABs disappear during ventricular unloading and do not increase thereafter. "Weaning" from mechanical device may constitute an alternative treatment to cardiac transplantation in selected patients.  相似文献   

17.
An important consideration for clinical application of rotary blood pump based ventricular assist is the avoidance of ventricular collapse due to excessive operating speed. Because healthy animals do not typically demonstrate this phenomenon, it is difficult to evaluate control algorithms for avoiding suction in vivo. An acute hemodynamic study was thus conducted to determine the conditions under which suction could be induced. A 70 kg calf was implanted with an axial flow assist device (Nimbus/UoP IVAS; Nimbus Inc., Rancho Cordova, CA) cannulated from the left ventricular apex to ascending aorta. On initiation of pump operation, several vasoactive interventions were performed to alter preload, afterload, and contractility of the left ventricle. Initially, dobutamine increased contractility and heart rate ([HR] = 139; baseline = 70), but ventricular collapse was not achievable, even at the maximal pump speed of 15,000 rpm. Norepinephrine decreased HR (HR = 60), increased contractility, and increased systemic vascular resistance ([SVR] = 24; baseline = 15), resulting in ventricular collapse at a pump speed of 14,000 rpm. Isoproterenol (beta agonist) increased HR (HR = 103) and decreased SVR (SVR = 12), but ventricular collapse was not achieved. Inferior vena cava occlusion reduced preload, and ventricular collapse was achieved at speeds as low as 11,000 rpm. Esmolol (beta1 antagonist) decreased HR (HR = 55) and contractility, and ventricular collapse was achieved at 11,500 rpm. Episodes of ventricular collapse were characterized initially by the pump output exceeding the venous return and the aortic valve remaining closed throughout the cardiac cycle. If continued, the mitral valve would remain open throughout the cardiac cycle. Using these unique states of the mitral and aortic valves, the onset of ventricular collapse could reliably be identified. It is hoped that the ability to detect the onset of ventricular collapse, rather than the event itself, will assist in the development and the evaluation of control algorithms for rotary ventricular assist devices.  相似文献   

18.
Individuals with diabetes are at increased risk for both peripheral vascular disease and coronary artery disease. In patients with severe coronary artery disease, a cardiac assist device called an intra-aortic balloon pump (IABP) often is used to aid the failing heart and prevent further cardiac ischemia. Because this device is inserted via the femoral artery, patients are at risk of limb ischemia distal to the insertion site. Patients with diabetes are particularly prone to this complication. Detecting the early signs and symptoms of ischemia is crucial to preventing serious sequelae. Standard vascular examination techniques, in addition to being subjective and not easily reproducible, may be misleading in patients with diabetes. This article provides a review of the signs and symptoms of lower limb ischemia and noninvasive vascular tests that clinicians can use to evaluate lower extremity circulation. Also included are protocols for patient care during and after hospitalization, and two case studies of cardiac patients with diabetes who were treated with an IABP.  相似文献   

19.
Mechanical assisted circulation by the means of cardiac assist devices is a routine procedure in modern cardiac surgery and cardiology. We investigated the impact of mechanical unloading on regional myocardial "stunning" and the influence of assisted circulation on left heart and right heart failure persevered by an ultimate addition of pulmonary hypertension in experimental set ups. We found that mechanical unloading either during ischemia or in the early reperfusion phase attenuates stunning and enhances the return of synchronous heart performance. In our global dysfunction model we showed that the right heart is dispensable. Sufficient inflow to the left heart is provided unless pulmonary hypertension is present. Also additional left heart support can not overcome the deleterious situation and in select cases only additional right heart support can prevent the "low LVAD output" syndrome. We conclude that mechanical assisted circulation and mechanical unloading are beneficial in case of regional and global dysfunction persevered by pulmonary hypertension, however, the knowledge about interactions of assist systems and the circulation has to be improved in order to optimize clinical assist device performance.  相似文献   

20.
BACKGROUND: Both crystalloid and blood cardioplegia result in cardiac dysfunction associated with myocardial edema. This edema is partially due to the lack of myocardial contraction during cardioplegia, which stops myocardial lymph flow. As an alternative, acceptable surgical conditions have been created in patients undergoing coronary artery bypass operations with esmolol-induced minimal myocardial contraction. We hypothesized that minimal myocardial contraction during circulatory support using either standard cardiopulmonary bypass (CPB) or a biventricular assist device would prevent myocardial edema by maintaining cardiac lymphatic function and thus prevent cardiac dysfunction. METHODS: We placed 6 dogs on CPB and 6 dogs on a biventricular assist device and serially measured myocardial lymph flow rate and myocardial water content in both groups and preload recruitable stroke work only in the CPB dogs. In all dogs we minimized heart rate with esmolol for 1 hour during total circulatory support. RESULTS: Although myocardial lymph flow remained at baseline level during CPB and increased during biventricular assistance, myocardial water accumulation still occurred during circulatory support. However, as edema resolved rapidly after separation from circulatory support, myocardial water content was only slightly increased after CPB and biventricular assistance, and preload recruitable stroke work was normal. CONCLUSIONS: Our data suggest that minimal myocardial contraction during both CPB and biventricular assistance supports myocardial lymphatic function, resulting in minimal myocardial edema formation associated with normal left ventricular performance after circulatory support. The concept of minimal myocardial contraction may be a useful alternative for myocardial protection, especially in high-risk patients with compromised left ventricular function.  相似文献   