首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The effect of thermal conductivity of the absorber plate of a solar collector on the performance of a thermo-siphon solar water heater is found by using the alternative simulation system. The system is assumed to be supplied of hot water at 50 °C and 80 °C whereas both are used in domestic and industrial purposes, respectively. According to the Rand distribution profile 50, 125 and 250 l of hot water are consumed daily. The condition shows that the annual solar fraction of the planning functions and the collector's configuration factors are strongly dependent on the thermal conductivity for its lower values. The less dependence is observed beyond a thermal conductivity of 50 W/m °C for the solar improper fraction and above 100 W/m °C for the configuration factors. In addition, the number of air ducts and total mass flow rate are taken to show that higher collector efficiency is obtained under the suitable designing and operating parameters. Different heat transfer mechanisms, adding natural convection, vapor boiling, cell nucleus boiling and film wise condensation is observed in the thermo-siphon solar water heater with various solar radiations. From this study, it is found that the solar water heater with a siphon system achieves system characteristic efficiency of 18% higher than that of the conventional system by reducing heat loss for the thermo-siphon solar water heater.  相似文献   

2.
低流速净蒸汽产生点模型预测过冷沸腾空泡率   总被引:2,自引:0,他引:2       下载免费PDF全文
孙奇  杨瑞昌 《热能动力工程》2004,19(2):124-126,174
空泡率是汽液两相流动的基本参数之一,而已有过冷沸腾空泡率计算方法研究以高质量流速为主,且大量文献报道现有空泡率模型难以适用于低流速过冷沸腾工况。本文基于低流速过冷沸腾净蒸汽产生点(NVG)理论模型,进一步建立了计算过冷沸腾空泡率的分布拟合模型。在较宽广的压力、质量流速、热流密度和流道尺寸范围内将模型计算结果与现有空泡率实验数据进行了比较,低流速工况下该模型与实验数据符合良好,表明该模型可适用于低流速过冷沸腾工况。  相似文献   

3.
In this paper, an analytical steady state model is developed to study the thermal performance of an individual vacuum tube solar collector with coaxial piping (direct flow type) incorporating both single and two-phase flows. A system of equations which describe the different heat transfer mechanisms and flow conditions was established, discretised, and solved in an iterative manner. For the case of good vacuum condition (10?5 mb) the calculated efficiency curve for single phase flow deviates significantly from the experiments with increasing collector temperature, but agrees well for the case of gas conduction inside the glass envelope at very low pressure (?1 mb) due to the corresponding increase in overall heat loss coefficient (U-value).For two-phase flow, the occurrence and propagation of flow boiling and condensation inside the collector piping under saturated condition is hypothesized. The modeling results indicate that for all-liquid-single-phase fluid flow, the collector efficiency decreases with decreasing mass flow rate. Once the fluid reaches the boiling point at a certain mass flow rate, no significant reduction in efficiency is observed anymore, which is in accordance with the experimental study.  相似文献   

4.
Numerical simulations were conducted to investigate the refrigerant flow boiling in a horizontal serpentine round tube with the Eulerian multiphase flow model and a phase-change model for the mass transfer. Correspondingly, an experimental investigation was conducted to provide validation and data for the simulations. The liquid/vapor phase distributions show stratification in horizontal tubes, indicating the buoyancy force caused by gravity acceleration is dominant, especially when the vapor void fraction is sufficiently high. The adiabatic bend sections served to redistribute the vapor phase, which was induced by the centrifugal force and re-condensation of the vapor (due to thermal non-equilibrium of two phases). The phase distributions in the bend sections showed the competitive influence of buoyancy force and centrifugal force at different operating conditions. In all cases, the numerical simulations appear reasonably consistent with the experimental observations. In particular, the simulation very well explains the bend effects on flow reconstruction and thermal non-equilibrium release observed in the experiments.  相似文献   

5.
This work presents a numerical model to simulate steady state refrigerant flow along capillary tube-suction line heat exchangers, commonly used in small refrigeration systems. The flow along the straight and horizontal capillary tube is divided into two regions: a single-phase and a two-phase flow region. The flow is taken as one-dimensional and the metastable flow phenomenon is neglected. The two-fluid model is employed for the two-phase flow region, considering the hydrodynamic and the thermodynamic non-equilibrium between the liquid and vapor phases. Comparisons are made with experimental measurements of the mass flow rate and temperature distribution along capillary tube-suction line heat exchangers working with refrigerant R134a in different operating conditions. The results indicate that the present model provides a good estimation of the refrigerant mass flow rate. Moreover, comparisons with a homogeneous model are also made. Some computational results referring to the quality, void fraction and velocities of each phase are also presented and discussed.  相似文献   

6.
The objective of this work is to theoretically and experimentally investigate the flow and temperature distribution in a solar collector panel with an absorber consisting of horizontally inclined strips. Fluid flow and heat transfer in the collector panel are studied by means of computational fluid dynamics (CFD) calculations. Further, experimental investigations of a 12.5 m2 solar collector panel with 16 parallel connected horizontal fins are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the backside of the absorber tubes. The measured temperatures are compared to the temperatures determined by the CFD model and there is a good similarity between the measured and calculated results.

Calculations with the CFD model elucidate the flow and temperature distribution in the collector. The influences of different operating conditions such as flow rate, properties of solar collector fluid, solar collector fluid inlet temperature and collector tilt angle are shown. The flow distribution through the absorber fins is uniform if high flow rates are used. By decreased flow rate and decreased content of glycol in the glycol/water mixture used as solar collector fluid, and by increased collector tilt and inlet temperature, the flow distribution gets worse resulting in an increased risk of boiling in the upper part of the collector panel.  相似文献   


7.
Cheol Huh  Moo Hwan Kim 《传热工程》2013,34(8-9):730-737
The boiling heat transfer and two-phase pressure drop of water in a microscale channel were experimentally investigated. The tested horizontal rectangular microchannel had a hydraulic diameter of 100 μ m and length of 40 mm. A series of microheaters provided heat energy to the working fluid, which made it possible to control and measure the local thermal conditions in the direction of the flow. Both the microchannel and microheaters were fabricated using a micro-electro-mechanical systems (MEMS) technique. Flow patterns were obtained from real-time flow visualizations made during the flow boiling experiments. Tests were performed for mass fluxes of 90, 169, and 267 kg/m2s and heat fluxes from 200 to 500 kW/m2. The effects of the mass flux and vapor quality on the local flow boiling heat transfer coefficient and two-phase frictional pressure gradient were studied. The evaluated experimental data were compared with existing correlations. The experimental heat transfer coefficients were nearly independent of the mass flux and vapor quality. Most of the existing correlations did not provide reliable heat transfer coefficient predictions for different vapor quality values, nor could they predict the two-phase frictional pressure gradient except under some limited conditions.  相似文献   

8.
《传热工程》2012,33(9):786-791
Two-phase hydraulic characteristics, in terms of pressure drop and void fraction data, are reported for boiling of single-component hydrocarbon fluids in vertical upflow. These data were obtained simultaneously with the boiling heat transfer measurements. The systematic trends of the measured pressure gradient with respect to vapor quality, mass flux, and pressure are examined. This provides useful information in terms of the relative importance of the constituent parts of the two-phase pressure gradients and confirms the internal consistency of the measured data. These two-phase pressure-drop data under flow boiling conditions are then compared with various correlations from the open literature and also with a proprietary correlation used in commercial heat exchanger design and simulation software. Typical results of these comparisons are presented. It is noted that in the near-zero vapor quality region the measured pressure-gradient data may be lower than expected because of the effect of subcooled boiling.  相似文献   

9.
In a photovoltaic/thermal (PV/T) collector, a portion of absorbed solar energy is transformed into electrical energy, and the remaining part is transformed into thermal energy. Increasing waste heat collection and energy conversion rates are important to improve the performance of the PV/T collector. The utilization of microencapsulated phase change slurry (MPCS) in a PV/T collector to cool photovoltaic modules is an effective way, and electrical and thermal performances of the collector are improved. To investigate influences of operating parameters on performances of PV/T collector, numerical simulation is put into effect to analyze influences of the mass fraction of MPCS on the collector performance. The influences of MPCS mass flow rate and collector channel height on collector performances are also studied. When the flow rate is 0.005 kg/s and the channel height is 0.010 m, the PV/T collector obtains the best net efficiency with a MPCS mass concentration of 20 wt%. But electrical efficiency difference between 15 and 20 wt% is not obvious. With the growth in mass fraction, PV temperature drops more and more slowly because outlet fluid has not fully melt. Take PV/T collector performances into consideration, 15 wt% MPCS is a better choice to cool photovoltaic modules.  相似文献   

10.
In the last decade, no comprehensive numerical and experimental analyses have been performed to find the maximum possible power generation from a concentrated photovoltaic thermal (CPV/T) system by varying the flow rate of the fluid. This paper describes numerical and experimental studies of a U-shaped solar energy collector model of a CPV/T system, with the goal of determining the maximal thermal and electrical power outputs against a specific volumetric flow rate also called an optimum flow rate. The CPV/T system was based on the union of 8 triple junction solar cells, 8 SOG Fresnel lenses, effective dual-axis tracking, and a forced cooling system. Analyses were performed by changing the flow rate of the working fluid at a considered solar irradiation and ambient temperature. The thermal and electrical power outputs also varied with changes in the ambient temperature and available solar radiation. The relatively high value of CPV/T power was observed against the optimum flow rate at a given irradiation and ambient temperature. Analysis of the energy of the U- shaped solar energy collector system was evaluated experimentally. The numerical results and experimental measurements of the U-shaped solar energy collector model showed great harmony, with minimal deviations of <7% between them.  相似文献   

11.
Mini-channel heat exchangers with boiling flows present optimal performances: they are highly efficient and compact and require low fluid mass. However, classical correlations for two-phase flow in macro-channels fail in predicting the heat transfer coefficient and the eventual premature dry-out in mini-channels. Therefore, new studies are needed to provide better knowledge on flow boiling phenomena in small, confined spaces. The proposed paper presents an experimental study of vertical flow boiling in mini-channels. The pressure drop and the heat transfer coefficient in the test section have been measured for a variety of conditions. Different heat flux, inlet vapor quality, and mass flow rate values have been tested. A critical dry-out vapor quality depending on the mass flow rate has been found. Nevertheless, the superficial velocity appears to be much more appropriate than the vapor quality or the mass flow rate for the dry-out occurrence prediction. A clean dependence with a single critical velocity value has been found.  相似文献   

12.
《Applied Thermal Engineering》2001,21(10):1049-1065
Analytical and experimental studies were performed on a solar assisted heat pump water heating system, where unglazed, flat plate solar collectors acted as an evaporator for the refrigerant R-134a. The system was designed and fabricated locally, and operated under meteorological conditions of Singapore. The results obtained from simulation are used for the optimum design of the system and enable determination of compressor work, solar fraction and auxiliary energy required for a particular application. To ensure proper matching between the collector/evaporator load and compressor capacity, a variable speed compressor was used. Due to high ambient temperature in Singapore, evaporator can be operated at a higher temperature, without exceeding the desired design pressure limit of the compressor, resulting in an improved thermal performance of the system. Results show that, when water temperature in the condenser tank increases with time, the condensing temperature, also, increases, and the corresponding COP and collector efficiency values decline. Average values of COP ranged from about 4 to 9 and solar collector efficiency was found to vary between 40% and 75% for water temperatures in the condenser tank varying between 30°C and 50°C. A simulation model has been developed to analyse the thermal performance of the system. A series of numerical experiments have been performed to identify important variables. These results are compared with experimental values and a good agreement between predicted and experimental results has been found. Results indicate that the performance of the system is influenced significantly by collector area, speed of the compressor, and solar irradiation. An economic analysis indicates a minimum payback period of about two years for the system.  相似文献   

13.
In this technical article, a novel experimental setup is designed and proposed to produce a hydrogen by using solar energy. This system comprises a hybrid or photovoltaic Thermal (PVT) solar collector, Hoffman's voltameter, heat exchanger unit and Phase Change Material (PCM). The effect of PCM and mass flow rate of water on the hybrid solar collector efficiency and hydrogen yield rate is studied. This experimental results clearly showed that by adding the thermal collector with water, decreases PV module temperature by 20.5% compared with conventional PV module. Based on the measured values, at 12.00 and 0.011 kg/s mass flow rate, about 33.8% of thermal efficiency is obtained for water based hybrid solar collector. Similarly, by adding Paraffin PCM to the water based thermal collector, the maximum electrical efficiency of 9.1% is achieved. From this study, the average value of 17.12% and 18.61% hydrogen yield rate is attained for PVT/water and PVT/water with PCM systems respectively.  相似文献   

14.
Inspired by the sunflower, we report a new structure of a solar collector that integrates a pulsating heat pipe (PHP) into a flat-plate collector. The proposed flower-type PHP solar collector is designed after a sunflower with petals that absorb sunlight and transfer nutrients to the stem after photosynthesis. The evaporator section adopts the shape of a flower to absorb sunlight fully, and the condenser section is rolled into a cylinder and placed in the lower part of the structure. A systematic experimental study is conducted upon start-up, and the performance characteristics, with acetone as the working fluid, are evaluated. We also did a heat loss analysis, which has a deviation of 8%. The effects of the mass flow rate of cooling water, filling ratio, length of the condenser section, and solar intensity are assessed. As the temperature of the heat absorber plate increases, the thermal resistance of the PHP can decrease to a minimum of 0.14°C/W. Under sunny weather conditions, the instantaneous thermal efficiency of the system with a filling ratio of 50% reaches 50%. Besides, we discussed the unstable operation conditions and possible dryout phenomenon that happened inside the PHP.  相似文献   

15.
Direct steam generation (DSG) in parabolic trough solar collectors is a feasible option for economic improvement in solar thermal power generation. Three-dimensional Eulerian two-fluid simulations are performed under OpenFOAM to study the turbulent flow in the evaporation section of the parabolic trough receiver and investigate the phase change, and pressure drop of water as a heat transfer fluid. First, the model's validity has been tested by comparing the numerical results of a laboratory scale boiler with the available correlations and semi-correlations of boiling flows from the literature. Simulations agreed well with Rouhani–Axelsson correlation for horizontal tubes, with a mean relative error of less than 7.1% for all studied cases. However, despite a mean relative error of less than 13.19% compared to the experimental data in the literature, the reported pressure drop factor remains valid; overprediction remains tolerable for most engineering applications. Second, the scaling effect on the mathematical model, from laboratory to commercial-scale configuration, was tested with experimental data of the DISS test loop in Platforma Solar de Almeria, Spain. The Monte Carlo Ray Tracing method under the Tonatiuh package allowed for obtaining the nonuniform heat flux distribution. Due to the large size of the evaporation section in the DISS loop (eight collectors), each collector is considered independently in the simulations. Thus, simulations follow each other, taking the numerical results of each collector output as input data in the next collector and so on until the last. The numerical results showed an excellent agreement for the void fraction with 3.53% against the Rouhani–Axelsson correlation. Frictional pressure losses are within a 17.06% error of the Friedel correlation, in the range of previous work in the literature, and the heat loss is less than 4.69% error versus experimental correlation.  相似文献   

16.
In gas–liquid two-phase flow, the prediction of two-phase density and hence the hydrostatic pressure drop relies on the void fraction and is sensitive to the error in prediction of void fraction. The objectives of this study are to analyze dependence of two-phase density on void fraction and to examine slip ratio and drift flux model-based correlations for their performance in prediction of void fraction and two-phase densities for the two extremes of two-phase flow conditions, that is, bubbly and annular flow or, alternatively, the low and high region of the void fraction. It is shown that the drift flux model-based correlations perform better than the slip ratio model-based correlations in prediction of void fraction and hence the two-phase mixture density. Another objective of this study is to verify performance of different two-phase dynamic viscosity models in prediction of two-phase frictional pressure drop. Fourteen two-phase dynamic viscosity models are assessed for their performance against 616 data points consisting of 10 different pipe diameters in annular flow regime. It is found that none of these two-phase dynamic viscosity models are able to predict the frictional pressure drop in annular flow regime for a range of pipe diameters. The correlations that are successful for small pipe diameters fail for large pipe diameters and vice versa.  相似文献   

17.
基于VC 6.0开发了一种单相流沸腾传热模型,通过引入空泡份额的概念将沸腾发生时的流场看作一个气液均匀混合的单相流,从数学上对该模型进行了描述并介绍了模型的数值实现方法。通过与实验结果的对比,表明模型适用于缸盖冷却水腔内沸腾传热计算。实验和计算结果还表明,压力对沸腾传热的影响较为明显。最后以226B型发动机水腔为工程应用对象,计算出了水腔内的空泡份额分布和水腔内的流度分布情况。  相似文献   

18.
In this paper, an experimental study of the condensation of water vapor from a binary mixture of air and low‐grade steam has been depicted. The study is based upon diffusion heat transfer in the presence of high concentration of noncondensable gas. To simplify the study, experimental analysis is supported by empirical solutions. The experimental setup is custom designed for testing a new shell and tube type heat exchanger supplied by the manufacturer. Air–vapor mixture at 80 °C (max) and 20.2% relative humidity enters the heat exchanger at a mass flow rate of 480 kg/h and condenses 27 kg/h vapor using cooling water at an inlet temperature of 7 °C to 10 °C and mass flow rate of 3500 kg/h. By using the experimental data of constant inlet air mass fraction, mixture gas velocity, and different volumetric flow rate of the cold fluid, the local heat transfer coefficients are obtained. The main objective of this work is to establish an approximate value for surface area and overall heat transfer coefficient of a horizontal shell and tube condenser used in process space. Under designed working conditions, the condenser is found to work efficiently with 90% vapor condensation by mass.  相似文献   

19.
This paper describes a parametric improvement study of a solar adsorption refrigerator, using a flat plate collector with silica-gel and water as the adsorption pair. Based on a set of experimental results obtained with a prototype, used mainly for model validation purposes, a numerical study is conducted to determine the influence of the most relevant parameters and to improve the overall performance.The main parameters considered in this study are: the mass of silica-gel, the number of metallic fins in the silica-gel bed, the orientation of the solar collector (azimuth angle), the improvement of the collector's cooling during the night, the thermal contact resistance between silica-gel and the collector plate, the condenser surface area, the evaporation surface area, the radiant properties of the collector plate, and the thermal insulation of the refrigerated cabinet. The influence of each individual parameter is analyzed, and its optimum value is determined. The refrigeration system with all the individually obtained optimum parameters has an overall performance considerably higher than that corresponding to the analyzed prototype, providing useful information for a better integrated understanding of the solar adsorption refrigeration systems, and for a better design of such systems looking for their maximum overall performance.  相似文献   

20.
A new cooling scheme is proposed where the primary working fluid flowing through a micro-channel heat sink is pre-cooled to low temperature using an indirect refrigeration cooling system. Cooling performance was explored using HFE 7100 as working fluid and four different micro-channel sizes. High-speed video imaging was employed to help explain the complex interrelated influences of hydraulic diameter, micro-channel width, mass velocity and subcooling on cooling performance. Unlike most prior two-phase micro-channel heat sink studies, which involved annular film evaporation due high void fraction, the low coolant temperatures used in this study produced subcooled flow boiling conditions. Decreasing coolant temperature delayed the onset of boiling, reduced bubble size and coalescence effects, and enhanced CHF. Heat fluxes in excess of 700 W/cm2 could be managed without burnout. Premature CHF occurred at low mass velocities and was caused by vapor flow reversal toward the inlet plenum. This form of CHF was eliminated by decreasing coolant temperature and/or increasing flow rate.  相似文献   