首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Conventional balloon angioplasty treatment of aorto-ostial stenoses in native coronary arteries and saphenous vein grafts is associated with a low primary success rate, a high complication rate and a high incidence of restenosis. The short-term outcome of Palmaz-Schatz stent implantation in aorto-ostial lesions was compared with that of balloon angioplasty. Thirteen patients underwent stent implantation for 13 de novo lesions (four in the left main coronary trunk, two in the right coronary artery, seven in the vein graft) between January 1994 and December 1995. Fourteen patients underwent balloon angioplasty for 14 de novo lesions (five in the left main coronary trunk, four in the right coronary artery, five in the vein graft between January 1986 and April 1992. Both groups had similar clinical characteristics. Initial success was obtained in all patients in the stent group, compared with 71% of the balloon angioplasty group. Insufficient dilation was the main cause for such failure in the balloon angioplasty group. Baseline reference diameters were similar (3.40 +/- 0.65 mm in the stent group vs 3.36 +/- 0.42 mm in the balloon angioplasty group) and there was no difference in baseline minimal luminal diameter (1.41 +/- 0.74 vs 1.08 +/- 0.56 mm). Minimal luminal diameter was significantly greater in the stent group than in the balloon angioplasty group at both post-procedure and follow-up examinations (post: 3.36 +/- 0.58 vs 2.69 +/- 0.45 mm, p < 0.01; follow-up: 2.33 +/- 0.96 vs 1.52 +/- 0.68 mm, p < 0.05). There was no subacute occlusion in either group. The overall angiographic restenosis rate (> 50% stenosis) was lower in the stent group (17%) than in the balloon angioplasty group: the restenosis rates of native lesions were 0% in the stent group and 40% in the balloon angioplasty group; those of saphenous vein graft lesions were 33% in the stent group and 50% in the balloon angioplasty group. Although the number of patients was limited, these results suggest that Palmaz-Schatz stent implantation may be a safe and effective strategy for treating aorto-ostial lesions in both native coronary arteries and saphenous vein grafts.  相似文献   

2.
We investigated smooth muscle cell proliferation associated with restenosis after percutaneous transluminal coronary angioplasty (PTCA) in 8 arteries with fragmented internal elastic lamina obtained at autopsy in 7 patients who died between 2 months to 2 years 11 months after coronary angioplasty. The internal elastic lamina fragmentation, measured longitudinally along the blood vessels, measured 6.6 +/- 6.9 mm. Smooth muscle cell proliferation was concentrated around the fragmented internal elastic lamina, extending longitudinally even to unfragmented areas. The proliferation of smooth muscle cells extended for 1.8 +/- 2.2 mm in the proximal portion of the fragmentation, and for 2.0 +/- 2.9 mm in the distal portion. The possibility of new stenoses resulting from smooth muscle cell proliferation at sites adjacent to those subjected to PTCA should be borne in mind when PTCA of the proximal segments of the left anterior descending coronary artery is contemplated.  相似文献   

3.
Management of in-stent restenosis has become a significant challenge in interventional cardiology. The results of balloon angioplasty have been disappointing due to the high recurrence of restenosis at follow-up. Debulking of the restenotic tissue within the stents using directional coronary atherectomy (DCA) may offer a therapeutic advantage. We report the immediate clinical and angiographic outcomes and long-term clinical follow-up results of 45 patients (46 lesions), mean age 63+/-12 years, 73% men, with a mean reference diameter of 2.9+/-0.6 mm, treated with DCA for symptomatic Palmaz-Schatz in-stent restenosis. DCA was performed successfully in all 46 lesions and resulted in a postprocedural minimal luminal diameter of 2.7+/-0.7 mm and a residual diameter stenosis of 17+/-10%. There were no in-hospital deaths, Q-wave myocardial infarctions, or emergency coronary artery bypass surgeries. Four patients (9%) suffered a non-Q-wave myocardial infarction. Target lesion revascularization was 28.3% at a mean follow-up of 10+/-4.6 months. Kaplan-Meier event-free survival (freedom from death, myocardial infarction, and repeat target lesion revascularization) was 71.2% and 64.7% at 6 and 12 months after DCA, respectively. Thus, DCA is safe and efficacious for the treatment of Palmaz-Schatz in-stent restenosis. It results in a large postprocedural minimal luminal diameter and a low rate of both target lesion revascularization and combined major clinical events at follow-up.  相似文献   

4.
BACKGROUND: Diabetes is a major risk factor for restenosis after coronary balloon angioplasty. Recent studies have shown that coronary stenting significantly reduces restenosis compared with balloon angioplasty alone. However, limited information is available on the effect of coronary stenting in diabetic patients. METHODS AND RESULTS: We designed this study to analyze the effect of diabetes on restenosis in patients treated with either balloon angioplasty or coronary stenting who were enrolled in a 6-month angiographic follow-up program. Three hundred consecutive patients, 19% of whom were diabetics, who underwent coronary stent implantation during a single-vessel procedure on native coronary vessels and who had 6-month angiographic follow-up constituted the study group (stent group). Three hundred consecutive patients who underwent 6-month angiographic follow-up after single-vessel conventional balloon angioplasty served as control patients (balloon group). Preprocedural, postprocedural, and follow-up angiograms were analyzed with quantitative angiography. In the balloon group, the restenosis rate was almost twofold higher in diabetic than in nondiabetic patients (63% versus 36%; P=.0002) owing to both a greater late loss (0.79+/-0.70 versus 0.41+/-0.61 mm, respectively; P<.0001) and a higher rate of late vessel occlusion (14% versus 3%, respectively; P<.001). In the stent group, restenosis rates were similar in diabetics and nondiabetics (25% versus 27%, respectively). Furthermore, in the stent group, late loss (0.77+/-0.65 versus 0.79+/-0.57 mm, respectively) and the rate of late vessel occlusion (2% versus 1%, respectively) did not differ significantly between diabetic and nondiabetic patients. CONCLUSIONS: Although diabetics have increased rates of restenosis and late vessel occlusion after simple balloon angioplasty, they have the same improved outcome with coronary stenting that has been documented in nondiabetic patients.  相似文献   

5.
OBJECTIVES: We assessed the safety and efficacy of stent placement in patients with poorly controlled hypertension and renal artery stenoses, which are difficult to treat with balloon angioplasty alone. BACKGROUND: Preliminary experience with stent placement suggests improved results over balloon angioplasty alone in patients with atherosclerotic renal artery stenosis. METHODS: Balloon-expandable stents were placed in 100 consecutive patients (133 renal arteries) with hypertension and renal artery stenosis. Sixty-seven of the patients had unilateral renal artery stenosis treated and 33 had bilateral renal artery stenoses treated with stents placed in both renal arteries. RESULTS: Angiographic success, as determined by quantitative angiography, was obtained in 132 (99%) of 133 lesions. Early clinical success was achieved in 76% of the patients. Six months after stent placement, the systolic blood pressure was reduced from 173 +/- 25 to 147 +/- 23 mm Hg (p < 0.001); the diastolic pressure from 88 +/- 17 to 76 +/- 12 mm Hg (p < 0.001); and the mean number of antihypertensive medications per patient from 2.6 +/- 1 to 2.0 +/- 0.9 (p < 0.001). Angiographic follow-up at a mean of 8.7 +/- 5.0 months in 67 patients revealed restenosis (>50% diameter narrowing) in 15 (19%) of 80 stented vessels. CONCLUSIONS: Renal artery stenting is an effective treatment for renovascular hypertension, with a low angiographic restenosis rate. Stent placement appears to be a very attractive therapy in patients with lesions difficult to treat with balloon angioplasty such as renal aorto-ostial lesions and restenotic lesions, as well as after a suboptimal balloon angioplasty result.  相似文献   

6.
BACKGROUND: Intracoronary stenting reduces the rate of restenosis after angioplasty in patients with new coronary lesions. We conducted a prospective, randomized, multicenter study to determine whether intracoronary stenting, as compared with standard balloon angioplasty, reduces the recurrence of luminal narrowing in restenotic lesions. METHODS: A total of 383 patients who had undergone at least one balloon angioplasty and who had clinical and angiographic evidence of restenosis after the procedure were randomly assigned to undergo standard balloon angioplasty (192 patients) or intracoronary stenting with a Palmaz-Schatz stent (191 patients). The primary end point was angiographic evidence of restenosis (defined as stenosis of more than 50 percent of the luminal diameter) at six months. The secondary end points were death, Q-wave myocardial infarction, bypass surgery, and revascularization of the target vessel. RESULTS: The rate of restenosis was significantly higher in the angioplasty group than in the stent group (32 percent as compared with 18 percent, P= 0.03). Revascularization of the target vessel at six months was required in 27 percent of the angioplasty group but in only 10 percent of the stent group (P=0.001). This difference resulted from a smaller mean (+/-SD) minimal luminal diameter in the angioplasty group (1.85+/-0.56 mm) than in the stent group (2.04+/-0.66 mm), with a mean difference of 0.19 mm (P=0.01) at follow-up. Subacute thrombosis occurred in 0.6 percent of the angioplasty group and in 3.9 percent of the stent group. The rate of event-free survival at 250 days was 72 percent in the angioplasty group and 84 percent in the stent group (P=0.04). CONCLUSIONS: Elective coronary stenting was effective in the treatment of restenosis after balloon angioplasty. Stenting resulted in a lower rate of recurrent stenosis despite a higher incidence of subacute thrombosis.  相似文献   

7.
BACKGROUND: Restenosis remains the major limitation of coronary angioplasty. Coronary stents have reduced the incidence of restenosis in selected patients with relatively large vessels. No strategies to date have demonstrated a beneficial effect in vessels < 3.0 mm in diameter. We have shown in the MultiVitamins and Probucol (MVP) Trial that probucol, a potent antioxidant, reduces restenosis after balloon angioplasty. The purpose of this study was to determine whether the benefit of probucol therapy is maintained in the subgroup of patients with smaller coronary vessels. METHODS AND RESULTS: We studied a subgroup of 189 patients included in the MVP trial who underwent successful balloon angioplasty of at least one coronary segment with a reference diameter < 3.0 mm. One month before angioplasty, patients were randomly assigned to one of four treatments: placebo, probucol (500 mg), multivitamins (beta-carotene 30000 IU, vitamin C 500 mg, and vitamin E 700 IU), or probucol plus multivitamins twice daily. The treatment was maintained until follow-up angiography was performed at 6 months. The mean reference diameter of this study population was 2.49+/-0.34 mm. Lumen loss was 0.12+/-0.34 mm for probucol, 0.25+/-0.43 mm for the combined treatment, 0.35+/-0.56 mm for vitamins, and 0.38+/-0.51 mm for placebo (P=.005 for probucol). Restenosis rates per segment were 20.0% for probucol, 28.6% for the combined treatment, 45.1% for vitamins, and 37.3% for placebo (P=.006 for probucol). CONCLUSIONS: Probucol reduces lumen loss and restenosis rate after balloon angioplasty in small coronary arteries.  相似文献   

8.
BACKGROUND: Antioxidant treatment seems to reduce the development of restenosis after percutaneous transluminal angioplasty. In this study, the effect of Nicanartine, a new antioxidant drug with both antiproliferative and lipid-lowering properties, on the proliferative and inflammatory response after balloon angioplasty was investigated in a rabbit model of restenosis. METHODS: To induce pre-interventional plaques in the common carotid artery of 48 New Zealand White rabbits, electrostimulation was carried out for 28 days. After a break of 7 days, balloon angioplasty was performed in 36 animals, of which 18 received Nicanartine at a dose of 120 mg/kg body weight; the other 18 served as a control group. The vessels were excised by day 7 and 28 after balloon angioplasty and examined for intimal plaque size, macrophage content and proliferative activity. Bromodeoxyuridine labeling was used to determine proliferating cells in the dilated segment; macrophages were detected using the RAM-11 antibody. RESULTS: In the Nicanartine-treated group, immunohistological quantification 7 days after intervention showed a statistically significant (P< 0.05) reduction of both cells undergoing DNA synthesis (1.6+/-1.4% versus 3.7+/-2.2%) and intimal macrophages (0.7+/-1.2% versus 1.3+/-0.6%). Twenty-eight days after balloon angioplasty, proliferative activity in both groups was decreased to a level comparable to the non-dilated control groups. A clear trend towards smaller plaques could be seen in the Nicanartine group (0.146+/-0.077 mm2 versus 0.255+/-0.174 mm2). Total cholesterol levels did not differ significantly between the groups. CONCLUSION: Under treatment with Nicanartine a clear reduction in the proliferative and inflammatory response after balloon angioplasty was observed. Antioxidant treatment, especially with compounds having antiproliferative and lipid-lowering properties, appears to be an effective secondary preventive strategy after interventional treatment in patients with coronary artery disease.  相似文献   

9.
OBJECTIVES: The purpose of this prospective study was to evaluate the immediate results and the 6-month angiographic recurrent restenosis rate after balloon angioplasty for in-stent restenosis. BACKGROUND: Despite excellent immediate and mid-term results, 20% to 30% of patients with coronary stent implantation will present an angiographic restenosis and may require additional treatment. The optimal treatment for in-stent restenosis is still unclear. METHODS: Quantitative coronary angiography (QCA) analyses were performed before and after stent implantation, before and after balloon angioplasty for in-stent restenosis and on a 6-month systematic coronary angiogram to assess the recurrent angiographic restenosis rate. RESULTS: Balloon angioplasty was performed in 52 patients presenting in-stent restenosis. In-stent restenosis was either diffuse (> or =10 mm) inside the stent (71%) or focal (29%). Mean stent length was 16+/-7 mm. Balloon diameter of 2.98+/-0.37 mm and maximal inflation pressure of 10+/-3 atm were used for balloon angioplasty. Angiographic success rate was 100% without any complication. Acute gain was lower after balloon angioplasty for in-stent restenosis than after stent implantation: 1.19+/-0.60 mm vs. 1.75+/-0.68 mm (p=0.0002). At 6-month follow-up, 60% of patients were asymptomatic and no patient died. Eighteen patients (35%) had repeat target vessel revascularization. Angiographic restenosis rate was 54%. Recurrent restenosis rate was higher when in-stent restenosis was diffuse: 63% vs. 31% when focal, p=0.046. CONCLUSIONS: Although balloon angioplasty for in-stent restenosis can be safely and successfully performed, it leads to less immediate stenosis improvement than at time of stent implantation and carries a high recurrent angiographic restenosis rate at 6 months, in particular in diffuse in-stent restenosis lesions.  相似文献   

10.
BACKGROUND: There is controversy regarding the immediate and long-term effects of PTCA on the coronary flow reserve. METHODS AND RESULTS: A total of 54 patients with 1-vessel disease and normal left ventricular function were studied after balloon angioplasty (n=34) or stent implantation (n=20). Distal coronary blood flow velocity reserve (CFR) was defined as the ratio of adenosine-induced hyperemic versus baseline blood flow velocity with a 0.014-in Doppler guidewire. The relative CFR was defined as the ratio of the distal CFR and the reference CFR measured in the normal adjacent coronary artery. Hemodynamic and angiographic measurements were performed before and directly after balloon angioplasty or stent implantation and at 6-month follow-up. CFR after PTCA 相似文献   

11.
Proliferation of vascular smooth muscle cells (VSMCs) is considered to be one key event underlying the pathophysiology of restenosis after angioplasty. The parathyroid hormone-related peptide (PTHrP) and its receptor, a local autocrine and paracrine regulator of cellular growth in a variety of normal cell types, have been reported in the vicinity of VSMCs. To investigate how PTHrP might be involved in the process of neointimal formation after balloon angioplasty, we examined PTHrP expression in balloon-denuded rat carotid arteries and human coronary arteries that had been retrieved by directional atherectomy. In rat carotid arteries, the RNase protection assay and in situ hybridization demonstrated that PTHrP mRNA expression increased fourfold to sixfold 1 to 7 days after denudation and continued for 28 days, coincident with downregulation of PTH/PTHrP receptor mRNA expression. In situ hybridization and immunohistochemistry revealed that PTHrP expression in balloon-denuded carotid arteries was mainly localized to the neointima. To confirm the involvement of the PTHrP in human coronary artery restenotic lesions, immunohistochemical analysis of human coronary atherectomy specimens (23 primary and 10 restenotic lesions) was then performed. The number of intimal cells that expressed PTHrP protein was significantly higher in restenotic (407 +/- 53 cells/mm2; range, 143 to 739) than in stable angina (50 +/- 12 cells/mm2; range, 18 to 132; P<.05) or unstable angina (129 +/- 16 cells/mm2; range, 21 to 232; P<.05) specimens. These data demonstrate that PTHrP gene expression in VSMCs markedly increases during neointimal formation, supporting the hypothesis that PTHrP may play an important role in vascular stenosis as a regulator of VSMC proliferation.  相似文献   

12.
BACKGROUND: Experimental studies suggest that the antiproliferative effect of heparin after arterial injury is maximized by pretreatment. No previous studies of restenosis have used a pretreatment strategy. We designed this study to determine whether treatment with nadroparin, a low-molecular-weight heparin, started 3 days before the procedure and continued for 3 months, affected angiographic restenosis or clinical outcome after coronary angioplasty. METHODS AND RESULTS: In a prospective multicenter, double-blind, randomized trial, elective coronary angioplasty was performed on 354 patients who were treated with daily subcutaneous nadroparin (0.6 mL of 10,250 anti-Xa IU/mL) or placebo injections started 3 days before angioplasty and continued for 3 months. Angiography was performed just before and immediately after angioplasty and at follow-up. The primary study end point was angiographic restenosis, assessed by quantitative coronary angiography 3 months after balloon angioplasty. Clinical follow-up was continued up to 6 months. Clinical and procedural variables and the occurrence of periprocedural complications did not differ between groups. At angiographic follow-up, the mean minimal lumen diameter and the mean residual stenosis in the nadroparin group (1.37+/-0.66 mm, 51.9+/-21.0%) did not differ from the corresponding values in the control group (1.48+/-0.59 mm, 48.8+/-18.9%). Combined major cardiac-related clinical events (death, myocardial infarction, target lesion revascularization) did not differ between groups (30.3% versus 29.6%). CONCLUSIONS: Pretreatment with the low-molecular-weight heparin nadroparin continued for 3 months after balloon angioplasty had no beneficial effect on angiographic restenosis or on adverse clinical outcomes.  相似文献   

13.
Assessment of the hemodynamic and anatomic results following balloon angioplasty of discrete native coarctation of the aorta, with particular attention to "remodeling," has required repeat cardiac catheterization and angiography, which is invasive and has limited resolution. Eight patients with hypertension and discrete native coarctation with an otherwise normally developed aortic arch underwent angioplasty at 5.0 +/- 6.8 years of age. Angiographic cross-sectional areas of the aorta indexed to body surface area at the isthmus (I), coarctation site (C), and 1 cm distal to the coarctation site (Cd) pre- and postangioplasty were compared with MRI-indexed cross-sectional areas 18 +/- 10 months (MRI-1) and 35 +/- 11 months (MRI-2) postangioplasty. From preangioplasty to MRI-2, the isthmus was smaller (149 +/- 22 versus 127 +/- 27 mm2/m2; p < 0. 05). The coarctation site was larger postangioplasty (25 +/- 9 versus 116 +/- 40 mm2/m2; p < 0.001) with continued growth at latest follow-up (116 +/- 40 versus 164 +/- 36 mm2/m2; p < 0.01). The segment 1 cm distal to the coarctation site continued to decrease in area at latest follow-up (267 +/- 78 versus 163 +/- 38 mm2/m2; p < 0. 001). I versus C versus Cd at MRI-2 were similar, whereas postangioplasty and MRI-1 cross-sectional area measurements were significantly different. Following angioplasty of discrete native coarctation, the aorta becomes more uniform or undergoes "remodeling." Noninvasive MRI is an effective means of evaluating the anatomic result following balloon angioplasty, obviating the need for repeated invasive cardiac catheterizations.  相似文献   

14.
It is unclear whether new devices such as directional coronary atherectomy (DCA) or Palmaz-Schatz stent implantation improve long-term outcomes compared with conventional balloon angioplasty in patients with stable angina and de novo coronary artery lesions of type A or type B except for complete occlusive lesions investigated by the American College of Cardiology/American Heart Association task force on percutaneous transluminal coronary angioplasty. A total of 146 patients with stable angina and simple lesions were assigned to either conventional balloon angioplasty (62 patients), DCA (50 patients), or Palmaz-Schatz implantation (34 patients). The acute results and late outcomes were assessed by coronary angiography. The results of the three procedures were similar with respect to procedural success and complications. Patients who underwent stenting or DCA had a larger immediate increase in the diameter of the lumen and a larger luminal diameter immediately after the procedure than those who underwent balloon angioplasty. At six months follow-up, the patients treated by stenting continued to have a larger luminal diameter and a lower rate of restenosis than those treated with balloon angioplasty (2.30 +/- 0.66 vs 1.85 +/- 0.83 mm, p < 0.005; 5.9% vs 29%, p < 0.05) and DCA (2.30 +/- 0.66 vs 1.90 +/- 0.96 mm, p < 0.05; 5.9% vs 24%, NS). The patients treated with balloon angioplasty had a smaller late loss than those treated with DCA or Palmaz-Schatz stent. The patients treated with DCA had a larger loss index than those treated with balloon angioplasty or Palmaz-Schatz stent. Stenting was a significant factor in decreasing the rate of restenosis by logistic regression analysis, compared with balloon angioplasty. The angiographic outcomes were better in patients who received a stent than in those who received other treatments. This study suggests that even lesions stable for treatment by balloon angioplasty and DCA can also be treated with Palmaz-Schatz stents.  相似文献   

15.
A 47-year-old male patient was admitted to our hospital with acute anterior myocardial infarction. Immediate coronary angiography was carried out, which showed proximal occlusion of the left anterior descending artery (LAD). After mechanical recanalization, a reduction in vessel caliber at the site of occlusion was visible, and balloon angioplasty with consecutive stent implantation because of vessel wall dissection was performed. After the procedure, diameter reduction of the entire vessel segment distal to the stent and muscular bridging with subtotal systolic obliteration of the LAD and one diagonal branch were demonstrated. Diastolic coronary flow did not appear to be limited (TIMI 3). Dipyridamole-thallium cardiac imaging revealed an incomplete perfusion defect of the anteroseptal region and a reversible perfusion reduction of the anterolateral region. For definitive treatment, we decided to implant a 3.0 mm-stent at the site of muscular bridging. Although balloon sizing was adapted to the diameter of the proximal reference segment, measured by quantitative coronary angiography, coronary perforation into the right ventricular outflow tract due to balloon oversizing in the distal dilation segment occurred. The patient remained asymptomatic at rest as well as under exercise testing, and hemodynamics remained stable. Coronary re-angiography after 1 week demonstrated a persistent fistula with complete opacification of the LAD and normal coronary flow (TIMI 3). Within the following 3 months, the coronary fistula closed spontaneously. CONCLUSIONS: Muscular bridging is a rare cause of acute myocardial infarction. Balloon angioplasty and stent implantation in the bridged segment may be complicated by coronary artery perforation due to balloon oversizing. Risks and benefits of this therapeutic option, therefore, have to be critically evaluated, and careful selection of balloon size using measurements of proximal and distal reference diameter assessed by intravascular ultrasound is recommended. Coronary artery perforation into the myocardium with subsequent development of a fistula may be treated conservatively as long as the patient remains asymptomatic. The frequency of spontaneous closure of the fistula is high.  相似文献   

16.
PURPOSE: Suboptimal distal coronary flow reserve after successful balloon angioplasty has been attributed to angiographically unrecognized inadequate lumen expansion, and adjunct coronary stenting has been shown to improve coronary flow reserve. The aim of this study was to investigate whether myocardial fractional flow reserve (FFRmyo) would increase further after coronary stenting compared with balloon angioplasty alone in the same patient group. METHODS: FFRmyo and quantitative coronary angiography were obtained before and after pre-stent balloon dilation, and again after stent placement in 11 patients (7 left anterior descending artery, 3 right coronary artery and 1 left circumflex artery). FFRmyo was calculated as the ratio of Pd/Pa during intracoronary adenosine 5'-triphosphate (50 micrograms and 20 micrograms in the left and right coronary arteries, respectively)-induced maximum hyperemia, where Pd represents mean distal coronary pressure measured by a 2.1 Fr infusion catheter and Pa represents mean aortic pressure measured by the guiding catheter. RESULTS: Percent diameter stenosis significantly decreased after balloon angioplasty (74% +/- 15% vs 37% +/- 17%, p < 0.001), and decreased further after stent placement (18% +/- 10%, p < 0.001 vs baseline and balloon angioplasty). FFRmyo after coronary stenting (0.85 +/- 0.09) was significantly higher than that at baseline (0.51 +/- 0.16, p < 0.001) and after balloon angioplasty (0.77 +/- 0.11, p < 0.05). There was a significant correlation between angiographic variables and FFRmyo. The increase in lumen dimensions after coronary stenting was followed by a further significant improvement of FFRmyo. CONCLUSION: These results suggest that coronary stenting may provide a more favorable functional status and lumen geometry of residual coronary stenosis compared with balloon angioplasty alone.  相似文献   

17.
OBJECTIVES: This study evaluated the long-term impact of endoluminal low power red laser light (LPRLL) on restenosis in an atherosclerotic rabbit model. BACKGROUND: Despite widespread application of balloon angioplasty for treatment of coronary artery disease, restenosis limits its clinical benefits. Restenosis is a complex process and may be partly attributed to the inability of the vascular endothelium to regenerate and cover the denuded area at the site of arterial injury. We previously demonstrated that LPRLL stimulates endothelial cell proliferation in vitro and contributes to rapid endothelial regeneration after balloon injury in nonatherosclerotic rabbits. METHODS: Rabbit abdominal aortas (n = 12) were treated in separate zones with balloon dilation and balloon dilation plus laser illumination. Endoluminal laser therapy was performed using a laser-balloon catheter delivering a single dose of 10 mW for 3 min from a helium-neon laser (632 nm). Angiography was performed before and after treatment and was repeated 8 weeks before harvesting the aortas. RESULTS: Quantitative angiographic analysis demonstrated no differences in the minimal lumen diameter (MLD) between the two zones before treatment; an increase in the MLD in both zones after balloon angioplasty and a significant versus slight reduction of the MLD in the balloon treatment versus balloon plus laser zones at 8 weeks. Histologic examination showed a very high level of myointimal hyperplasia in the balloon treatment zones but a minimal level in the LPRLL-treated zones. Morphometric analysis revealed a statistically significant difference in the lumen area, intimal area and intima/media ratio between the balloon versus balloon plus laser treatment sites. CONCLUSIONS: Our experimental data indicate that endoluminal irradiation with LPRLL prevents restenosis after balloon angioplasty in an atherosclerotic rabbit model.  相似文献   

18.
Percutaneous balloon angioplasty was used to dilate inferior vena cava (IVC) stenosis in 12 patients with Budd Chiari syndrome. There were seven men and five women, aged 32.8 +/- 8.5 years. Angioplasty was performed using balloon 18-20 mm in diameter. In eleven (91.6%) patients, IVC could be successfully dilated. In these eleven patients, the caval diameter at the site of stenosis increased from 2.3 +/- 1.5 to 13.1 +/- 2.8 mm (p < 0.001), the mean IVC pressure decreased from 28.2 +/- 4.1 to 10.5 +/- 3.4 mmHg (p < 0.001) and the gradient across the stenosis decreased from 23.1 +/- 2.2 to 4.2 +/- 1.9 mmHg (p < 0.001). There was appreciable clinical improvement after angioplasty. On a mean followup of 10.8 (3-18) months four (36.4%) patients had restenosis which could be successfully dilated again. These results suggest that balloon dilatation of inferior vena cava stenosis is safe and effective, however, recurrence is common and needs redilatation.  相似文献   

19.
OBJECTIVE: Before balloon dilation, failure of compensatory enlargement and even arterial shrinkage are frequently observed at the lesion site in response to plaque accumulation. Balloon angioplasty may be regarded as artificial remodeling to enlarge the artery. The prevalence of the different types of arterial wall remodeling after applied stretch by balloon angioplasty is unknown. METHODS AND RESULTS: In 181 patients an intravascular ultrasound study was performed after coronary balloon angioplasty (n = 200 lesions). The vessel area was measured at a proximal and distal reference site and at the lesion site. Subsequently, the relative vessel area [(Vessel area lesion site)/Vessel area reference site) x 100] was calculated. Lesions were classified in three groups on the basis of their relative vessel areas: > or =105%, <105% but >95%, and < or =95%. A relative vessel area > or =105%, indicating enlargement compared with the reference site, was observed in 84 (44%) lesions. A relative vessel area <105% but >95% was observed in 43 (22%) lesions. A relative vessel area < or =95%, indicating "shrinkage" compared with the reference site, was observed in 66 (34%) lesions. CONCLUSIONS: After balloon angioplasty, the vessel area was found to be smaller compared with the reference site in 34% of the lesions. This small vessel area at the lesion site compared with a reference site may be a reflection of insufficient stretch by balloon angioplasty.  相似文献   

20.
OBJECTIVE: Remodeling in de novo atherosclerosis and in restenosis after balloon angioplasty constitutes a change in total arterial circumference which, together with plaque growth or neointimal formation, determines the lumen of the artery. To better understand the fundamental biology of neointimal formation, remodeling and their interaction, animal studies are needed. In this study, we described in detail the methodology used and the natural history of neointimal formation and remodeling after balloon angioplasty in atherosclerotic Yucatan micropigs. METHODS AND RESULTS: Atherosclerosis was induced in 60 peripheral arteries of sixteen Yucatan micropigs by a combination of denudation and atherogenic diet. Balloon angioplasty was performed in 38 arteries, with serial intravascular ultrasound (IVUS) and quantitative angiography before and after intervention and at 2, 4, 7, 14 or 42 days follow-up. Remodeling, expressed as late media-bounded area (MBA) loss, increased progressively over time. At 42 days, late MBA loss after balloon angioplasty was significantly different compared to late MBA loss in control arteries, 2.2 +/- 1.0 versus -0.3 +/- 1.1 mm2 and p = 0.02. Late lumen loss increased over time and was highest at 42 days after balloon angioplasty (2.8 +/- 0.7 mm2). The contribution of neointimal formation to late lumen loss decreased over time and the contribution of late MBA loss to late lumen increased over time and was highest at 42 days (78%). Medial necrosis was 48% at two days after balloon angioplasty and the repopulation of the media was almost completed at seven days. CONCLUSION: Remodeling following balloon angioplasty has an early onset and progresses with neointimal formation to cause restenosis over the standard 42-day time course for Yucatan micropigs. This correlates to six months renarrowing in humans. In this model, atherosclerosis and the natural history of restenosis, both with respect to neointimal formation and remodeling, resemble the human disease quite closely.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号