1.
A high-speed rotational atherectomy was performed followed by adjunct directional atherectomy in 10 patients with symptomatic coronary artery disease and calcified target lesions and the results were evaluated using quantitative coronary arteriography and intravascular ultrasound. Target lesion calcium is common in obstructive coronary artery disease. High-speed rotational coronary atherectomy preferentially abrades noncompliant atherosclerotic plaque material, especially calcium, but often requires adjunct balloon angioplasty to achieve optimal lumen dimensions. Directional coronary atherectomy has limited efficacy in heavily calcified plaque; usually, it is a definitive primary procedure in large arteries with noncalcified target lesions. Neither of these devices alone is effective in treating calcified target lesions in large coronary arteries. Before intervention, after rotational and adjunct directional atherectomy, these measurements were obtained: quantitative coronary arteriographic measurements of minimal lumen diameter and percent diameter stenosis and intravascular ultrasound measurements of external elastic membrane, lumen, and plaque+media cross-sectional areas; percent cross-sectional narrowing; minimal lumen diameter; and target-lesion arc of calcium. With use of quantitative coronary arteriography, the preintervention minimal lumen diameter measured 0.7 +/- 0.4 mm, increased to 1.5 +/- 0.5 mm after rotational atherectomy (p = 0.0013) and to 2.5 +/- 0.3 mm after adjunct directional atherectomy (p < 0.001). The preintervention percent diameter stenosis measured 78 +/- 15%, decreased to 50 +/- 17% after rotational atherectomy (p = 0.0011), and to 17 +/- 11% (p < 0.001) after adjunct directional coronary atherectomy.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

2.
With the increasing clinical application of new devices for percutaneous coronary revascularization, maximization of the acute angiographic result has become widely recognized as a key factor in maintained clinical and angiographic success. What is unclear, however, is whether the specific mode of action of different devices might exert an additional independent effect on late luminal renarrowing. The purpose of this study was to investigate such a difference in the degree of provocation of luminal renarrowing (or 'restenosis propensity') by different devices, among 3660 patients, who had 4342 lesions successfully treated by balloon angioplasty (n = 3797), directional coronary atherectomy (n = 200), Palmaz-Schatz stent implantation (n = 229) or excimer laser coronary angioplasty (n = 116) and who also underwent quantitative angiographic analysis pre- and post-intervention and at 6-month follow-up. To allow valid comparisons between the groups, because of significant differences in coronary vessel size (balloon angioplasty = 2.62 +/- 0.55 mm, directional coronary atherectomy = 3.28 +/- 0.62 mm, excimer laser coronary angioplasty = 2.51 +/- 0.47 mm, Palmaz-Schatz = 3.01 +/- 0.44 mm; P < 0.0001), the comparative measurements of interest selected were the 'relative loss' in luminal diameter (RLoss = loss/vessel size) to denote the restenosis process, and the 'relative lumen at follow-up' (RLfup = minimal luminal diameter at follow up/vessel size) to represent the angiographic outcome. For consistency, lesion severity pre-intervention was represented by the 'relative lumen pre' (RLpre = minimal luminal diameter pre/vessel size) and the luminal increase at intervention was measured as 'relative gain' (relative gain = gain/ vessel size). Differences in restenosis propensity between devices was evaluated by univariate and multivariate analysis. Multivariate models were constructed to determine relative loss and relative lumen at follow-up, taking account of relative lumen pre-intervention, lesion location, relative gain, vessel size and the device used. In addition, model-estimated relative loss and relative lumen at follow-up at given relative lumen pre-intervention relative gain and vessel size, were compared among the four groups. Significant differences were detected among the groups both with respect to these estimates, as well as in the degree of influence of progressively increasing relative gain, on the extent of renarrowing (relative loss) and angiographic outcome (relative lumen at follow-up), particularly at higher levels of luminal increase (relative gain). Specifically, lesions treated by balloon angioplasty or Palmaz-Schatz stent implantation (the predominantly 'dilating' interventions) were associated with more favourable angiographic profiles than directional atherectomy or excimer laser (the mainly 'debulking' interventions). Significant effects of lesion severity and location, as well as the well known influence of luminal increase on both luminal renarrowing and late angiographic outcome were also noted. These findings indicate that propensity to restenosis after apparently successful intervention is influenced not only by the degree of luminal enlargement achieved at intervention, but by the device used to achieve it. In view of the clinical implications of such findings, further evaluation in larger randomized patient populations is warranted.  相似文献   

3.
OBJECTIVES: This study was designed to examine whether oversized implantation of the new, less shortening Wallstent provides a more favorable long-term clinical and angiographic outcome in chronic total occlusions than does conventional coronary balloon angioplasty. BACKGROUND: Restenosis and reocclusion remain major limitations of balloon angioplasty for chronic total occlusions. Enforced mechanical remodeling by implantation of the oversized Wallstent may prevent elastic recoil and improve accommodation of intimal hyperplasia. METHODS: Lumen dimension was measured by a computer-based quantitative coronary angiography system (CAAS II). These measurements (before and after intervention and at 6-month follow-up) were compared between the groups with Wallstent implantation (20 lesions, 20 patients) and conventional balloon angioplasty (266 lesions, 249 patients) for treatment of chronic total occlusion. Acute gain (minimal lumen diameter after intervention minus that before intervention), late loss (minimal lumen diameter after intervention minus that at follow-up) and net gain (acute gain minus late loss) were examined. RESULTS: Wallstent deployment was successful in all patients. High pressure intra-Wallstent balloon inflation (mean +/- SD 14 +/- 3 atm) was performed in all lesions. Although vessel size did not differ between the Wallstent and balloon angioplasty groups, acute gain was significantly greater in the Wallstent group (2.96 +/- 0.55 vs. 1.61 +/- 0.34 mm, p < 0.0001). Although late loss was also significantly larger in the Wallstent group (0.81 +/- 0.95 vs. 0.43 +/- 0.68 mm, p < 0.05), net gain was still significantly greater in this group (2.27 +/- 1.00 vs. 1.18 +/- 0.69 mm, p < 0.0001). Angiographic restenosis (> or = 50% diameter stenosis) occurred at 6 months in 29% of lesions in the Wallstent group and in 45% of those in the balloon angioplasty group (p = 0.5150). CONCLUSIONS: Implantation of the oversized Wallstent, with full coverage of the lesion length, ensures resetting of the vessel size to its original caliber before disease and allows greater accommodation of intimal hyperplasia and chronic vessel recoil. Wallstent implantation provides a more favorable short- and long-term clinical and angiographic outcome than does conventional balloon angioplasty for chronic total occlusions.  相似文献   

4.
The Bard Atherectomy Catheter is a new rotational atherectomy device that consists of a flexible, hollow, thin-walled cutting catheter that, while rotated at 1,500 revolutions per minute, is advanced across the lesion over a special spiral guidewire system. We report the initial clinical experience with this device in 20 peripheral lesions in ten patients. The majority of patients were treated for limb salvage. All lesions were successfully intervened on by atherectomy followed by adjunctive balloon angioplasty. A reduction to less than 50% stenosis was achieved in 13 of the 20 lesions (65%) after atherectomy but in all 20 lesions (100%) after adjunctive angioplasty for all lesions and stenting for dissections in two. Baseline minimal lesion lumen diameter was 0.8 +/- 0.7 mm with a reference vessel diameter of 4.2 +/- 1.7 mm (75 +/- 21% stenosis). The lumen improved to 2.0 +/- 0.8 mm (45 +/- 19% stenosis) (P < 0.001) following atherectomy and to 3.9 +/- 1.9 mm (13 +/- 16% stenosis) (P < 0.001) after adjunctive angioplasty. The average weight of removed atheroma was 45 +/- 58 mg. All ten patients had initial improvement in symptoms. At 6 months follow-up there was persistent improvement in eight patients and two subjects had undergone amputations. Our early clinical experience with this low profile, flexible atherectomy device, that enables extraction of a large amount of atheroma, suggests that it will become a valuable addition to current atherectomy technologies in small- and medium-sized vessels. The value of this device in coronary vessels is under investigation.  相似文献   

5.
It is unclear whether new devices such as directional coronary atherectomy (DCA) or Palmaz-Schatz stent implantation improve long-term outcomes compared with conventional balloon angioplasty in patients with stable angina and de novo coronary artery lesions of type A or type B except for complete occlusive lesions investigated by the American College of Cardiology/American Heart Association task force on percutaneous transluminal coronary angioplasty. A total of 146 patients with stable angina and simple lesions were assigned to either conventional balloon angioplasty (62 patients), DCA (50 patients), or Palmaz-Schatz implantation (34 patients). The acute results and late outcomes were assessed by coronary angiography. The results of the three procedures were similar with respect to procedural success and complications. Patients who underwent stenting or DCA had a larger immediate increase in the diameter of the lumen and a larger luminal diameter immediately after the procedure than those who underwent balloon angioplasty. At six months follow-up, the patients treated by stenting continued to have a larger luminal diameter and a lower rate of restenosis than those treated with balloon angioplasty (2.30 +/- 0.66 vs 1.85 +/- 0.83 mm, p < 0.005; 5.9% vs 29%, p < 0.05) and DCA (2.30 +/- 0.66 vs 1.90 +/- 0.96 mm, p < 0.05; 5.9% vs 24%, NS). The patients treated with balloon angioplasty had a smaller late loss than those treated with DCA or Palmaz-Schatz stent. The patients treated with DCA had a larger loss index than those treated with balloon angioplasty or Palmaz-Schatz stent. Stenting was a significant factor in decreasing the rate of restenosis by logistic regression analysis, compared with balloon angioplasty. The angiographic outcomes were better in patients who received a stent than in those who received other treatments. This study suggests that even lesions stable for treatment by balloon angioplasty and DCA can also be treated with Palmaz-Schatz stents.  相似文献   

6.
OBJECTIVES: The purpose of this study was to compare the immediate angiographic and long-term results of debulking versus balloon angioplasty for treatment of true bifurcation lesions. BACKGROUND: Previous studies have shown true bifurcation lesions to be a high risk morphological subset for percutaneous transluminal coronary angioplasty (PTCA). Although atherectomy devices have been used to treat bifurcation lesions, no studies have compared the outcomes of these alternative treatment modalities. METHODS: Between January 1992 and May 1997, we treated 70 consecutive patients with true bifurcation lesions (defined as a greater than 50% stenosis in both the parent vessel and contiguous side branch) with conventional PTCA (n = 30) or debulking (with rotational or directional atherectomy) plus adjunctive PTCA (n = 40). Paired angiograms were analyzed by quantitative angiography, and clinical follow-up was obtained in all patients. RESULTS: Acute procedural success was 73% in the PTCA group and 97% in the debulking group (p = 0.01). Major in-hospital complications occurred in two patients in the PTCA group and one in the debulking group. Treatment with atherectomy plus PTCA resulted in lower postprocedure residual stenoses than PTCA alone (16+/-15% vs. 33+/-17% in the parent vessel, and 6+/-15% vs. 39+/-22% in the side branch; p < 0.001 for both comparisons). At 1 year follow-up, the incidence of target vessel revascularization (TVR) was 53% in the PTCA group as compared with 28% in the debulking group (p = 0.05). Independent predictors of the need for repeat TVR were side branch diameter >2.3 mm, longer lesion lengths, and treatment with PTCA alone. CONCLUSIONS: For the treatment of true bifurcation lesions, atherectomy with adjunctive PTCA is safe, improves acute angiographic results, and decreases target vessel revascularization compared to PTCA alone. The benefits of debulking for bifurcation lesions were especially seen in lesions involving large side branches.  相似文献   

7.
BACKGROUND: Early loss of minimal luminal diameter of >0.3 mm after successful percutaneous transluminal coronary angioplasty (PTCA) is associated with a higher incidence of restenosis. The underlying mechanism of this early loss is unknown and thrombus may be a contributing factor. METHODS: We performed a prospective study using quantitative computerized planimetry on coronary tissue specimens obtained by directional coronary atherectomy of 24 lesions in which early loss occurred 22+/-9 minutes after successful PTCA. RESULTS: Thrombus was present in 9 (37%) of 24 coronary specimens. Segmental areas (mm2) and percentage of total area were distributed as follows: sclerotic tissue, 4.07+/-0.7 mm2 (63%+/-6%); fibrocellular tissue, 0.97+/-0.27 mm2 (16%+/-4%); hypercellular tissue, 0.99+/-0.29 mm2 (12%+/-3%); atheromatous gruel, 0.18+/-0.07 mm2 (3%+/-0.1%); and thrombus, 0.24+/-0.15 mm2 (6%+/-0.4%). There was no difference in the relative early loss index between lesions with or without thrombus (35%+/-7% vs 26%+/-2%, respectively; P= .87). Multiple stepwise regression analysis did not identify any histologic predictors of relative early loss index. CONCLUSION: Histopathologic analysis of coronary lesions with early loss after successful PTCA suggests that thrombus may not play a significant role in this angiographic phenomenon.  相似文献   

8.
BACKGROUND: Restenosis remains the major limitation of coronary angioplasty. Coronary stents have reduced the incidence of restenosis in selected patients with relatively large vessels. No strategies to date have demonstrated a beneficial effect in vessels < 3.0 mm in diameter. We have shown in the MultiVitamins and Probucol (MVP) Trial that probucol, a potent antioxidant, reduces restenosis after balloon angioplasty. The purpose of this study was to determine whether the benefit of probucol therapy is maintained in the subgroup of patients with smaller coronary vessels. METHODS AND RESULTS: We studied a subgroup of 189 patients included in the MVP trial who underwent successful balloon angioplasty of at least one coronary segment with a reference diameter < 3.0 mm. One month before angioplasty, patients were randomly assigned to one of four treatments: placebo, probucol (500 mg), multivitamins (beta-carotene 30000 IU, vitamin C 500 mg, and vitamin E 700 IU), or probucol plus multivitamins twice daily. The treatment was maintained until follow-up angiography was performed at 6 months. The mean reference diameter of this study population was 2.49+/-0.34 mm. Lumen loss was 0.12+/-0.34 mm for probucol, 0.25+/-0.43 mm for the combined treatment, 0.35+/-0.56 mm for vitamins, and 0.38+/-0.51 mm for placebo (P=.005 for probucol). Restenosis rates per segment were 20.0% for probucol, 28.6% for the combined treatment, 45.1% for vitamins, and 37.3% for placebo (P=.006 for probucol). CONCLUSIONS: Probucol reduces lumen loss and restenosis rate after balloon angioplasty in small coronary arteries.  相似文献   

9.
Registries of excimer laser coronary angioplasty have reported good results in the treatment of complex coronary artery disease, including total or subtotal coronary occlusions. One hundred three patients (103 lesions) with a functional or total coronary occlusion were included in a randomized trial (Amsterdam-Rotterdam [AMRO] trial, total of 308 patients), 49 patients were allocated to laser angioplasty and 54 patients to balloon angioplasty. The primary clinical end points were death, myocardial infarction, coronary bypass surgery, or repeated coronary angioplasty of the randomized segment during a 6-month follow-up period. The primary angiographic end point was the minimal lumen diameter at follow-up in relation to the baseline value (net gain), as determined by an automated contour-detection algorithm. Laser angioplasty was followed by balloon angioplasty in all procedures. The angiographic success rate was 65% in patients treated with excimer laser-assisted balloon angioplasty compared with 61% in patients treated with balloon angioplasty alone. No deaths occurred. There were no significant differences between the laser angioplasty group and the balloon angioplasty group in the incidence of myocardial infarctions (1 patient vs 3, respectively, p = 0.36), coronary bypass surgery (4 patients vs 2, respectively, p = 0.34), repeat angioplasty (10 patients vs 8, respectively, p = 0.46) or primary clinical end point (15 patients vs 12, respectively, p = 0.34). The net gain in minimal lumen diameter and restenosis rate (>50% diameter stenosis at follow-up) were 0.81 +/- 0.74 mm and 66.7%, respectively, in patients treated with laser angioplasty compared with 1.04 +/- 0.68 mm and 48.5%, respectively, in patients treated with balloon angioplasty (p = 0.59 and p = 0.15, respectively). Excimer laser-assisted balloon angioplasty demonstrated no benefit over balloon angioplasty with respect to initial and long-term clinical and angiographic outcome in the treatment of patients with functional or total coronary occlusions of >10 mm in length.  相似文献   

10.
Conventional balloon angioplasty treatment of aorto-ostial stenoses in native coronary arteries and saphenous vein grafts is associated with a low primary success rate, a high complication rate and a high incidence of restenosis. The short-term outcome of Palmaz-Schatz stent implantation in aorto-ostial lesions was compared with that of balloon angioplasty. Thirteen patients underwent stent implantation for 13 de novo lesions (four in the left main coronary trunk, two in the right coronary artery, seven in the vein graft) between January 1994 and December 1995. Fourteen patients underwent balloon angioplasty for 14 de novo lesions (five in the left main coronary trunk, four in the right coronary artery, five in the vein graft between January 1986 and April 1992. Both groups had similar clinical characteristics. Initial success was obtained in all patients in the stent group, compared with 71% of the balloon angioplasty group. Insufficient dilation was the main cause for such failure in the balloon angioplasty group. Baseline reference diameters were similar (3.40 +/- 0.65 mm in the stent group vs 3.36 +/- 0.42 mm in the balloon angioplasty group) and there was no difference in baseline minimal luminal diameter (1.41 +/- 0.74 vs 1.08 +/- 0.56 mm). Minimal luminal diameter was significantly greater in the stent group than in the balloon angioplasty group at both post-procedure and follow-up examinations (post: 3.36 +/- 0.58 vs 2.69 +/- 0.45 mm, p < 0.01; follow-up: 2.33 +/- 0.96 vs 1.52 +/- 0.68 mm, p < 0.05). There was no subacute occlusion in either group. The overall angiographic restenosis rate (> 50% stenosis) was lower in the stent group (17%) than in the balloon angioplasty group: the restenosis rates of native lesions were 0% in the stent group and 40% in the balloon angioplasty group; those of saphenous vein graft lesions were 33% in the stent group and 50% in the balloon angioplasty group. Although the number of patients was limited, these results suggest that Palmaz-Schatz stent implantation may be a safe and effective strategy for treating aorto-ostial lesions in both native coronary arteries and saphenous vein grafts.  相似文献   

11.
BACKGROUND: The Canadian Coronary Atherectomy Trial (CCAT) assessed, in a randomized comparison, the clinical and angiographic outcomes following atherectomy with those following balloon angioplasty for the treatment of de novo lesions in the proximal one-third of the left anterior descending artery (LAD). Although the procedural success rate was somewhat higher and the postprocedure lumen larger in patients treated with atherectomy, lumen dimensions, restenosis rates and clinical outcomes were similar in the two groups at six months. To determine whether late differences emerged between the groups, clinical follow-up was obtained at a median of 18 (range 10 to 31) months after randomization. METHODS AND RESULTS: Patients were contacted monthly by telephone for the first six months. Subsequent follow-up information was obtained in 272 (99%) of the 274 randomized patients via a clinic visit or telephone interview with the patient and/or a relative. Additional information was obtained from the referring physician as required. There were no differences in adverse events between the two groups during follow-up. In patients randomized to atherectomy compared with balloon angioplasty, death occurred in 1.5% versus 2.2% (cardiac death 0.7% versus 0.7%); myocardial infarction in 5.1% versus 5.9% (Q wave 1.5% versus 1.5%); coronary bypass surgery in 13.1% versus 12.6%; and repeat target lesion intervention in 22.6% versus 21.5%. Persistent or recurrent Canadian Cardiovascular Society class III/IV angina not treated by a further intervention was present in 1.5% versus 2.2%. The combined end-point of death or nonfatal myocardial infarction occurred in nine (6.6%) versus 11 (8.1%) patients and any adverse cardiac event in 50 (36.5%) versus 53 (39.3%). Multivariate logistic regression indicated that unstable angina, reference vessel size and preprocedure minimum lumen diameter were the only variables independently associated with adverse events. CONCLUSIONS: The initial choice of directional atherectomy or balloon angioplasty had no impact on clinical outcome over a period of 18 months in this patient population. With either technique, just over 60% of patients with proximal LAD disease experienced sustained symptomatic improvement without an adverse event following a single procedure, and 80% achieved this status following a repeat percutaneous intervention.  相似文献   

12.
PURPOSE: Suboptimal distal coronary flow reserve after successful balloon angioplasty has been attributed to angiographically unrecognized inadequate lumen expansion, and adjunct coronary stenting has been shown to improve coronary flow reserve. The aim of this study was to investigate whether myocardial fractional flow reserve (FFRmyo) would increase further after coronary stenting compared with balloon angioplasty alone in the same patient group. METHODS: FFRmyo and quantitative coronary angiography were obtained before and after pre-stent balloon dilation, and again after stent placement in 11 patients (7 left anterior descending artery, 3 right coronary artery and 1 left circumflex artery). FFRmyo was calculated as the ratio of Pd/Pa during intracoronary adenosine 5'-triphosphate (50 micrograms and 20 micrograms in the left and right coronary arteries, respectively)-induced maximum hyperemia, where Pd represents mean distal coronary pressure measured by a 2.1 Fr infusion catheter and Pa represents mean aortic pressure measured by the guiding catheter. RESULTS: Percent diameter stenosis significantly decreased after balloon angioplasty (74% +/- 15% vs 37% +/- 17%, p < 0.001), and decreased further after stent placement (18% +/- 10%, p < 0.001 vs baseline and balloon angioplasty). FFRmyo after coronary stenting (0.85 +/- 0.09) was significantly higher than that at baseline (0.51 +/- 0.16, p < 0.001) and after balloon angioplasty (0.77 +/- 0.11, p < 0.05). There was a significant correlation between angiographic variables and FFRmyo. The increase in lumen dimensions after coronary stenting was followed by a further significant improvement of FFRmyo. CONCLUSION: These results suggest that coronary stenting may provide a more favorable functional status and lumen geometry of residual coronary stenosis compared with balloon angioplasty alone.  相似文献   

13.
OBJECTIVES: The purpose of this prospective study was to evaluate the immediate results and the 6-month angiographic recurrent restenosis rate after balloon angioplasty for in-stent restenosis. BACKGROUND: Despite excellent immediate and mid-term results, 20% to 30% of patients with coronary stent implantation will present an angiographic restenosis and may require additional treatment. The optimal treatment for in-stent restenosis is still unclear. METHODS: Quantitative coronary angiography (QCA) analyses were performed before and after stent implantation, before and after balloon angioplasty for in-stent restenosis and on a 6-month systematic coronary angiogram to assess the recurrent angiographic restenosis rate. RESULTS: Balloon angioplasty was performed in 52 patients presenting in-stent restenosis. In-stent restenosis was either diffuse (> or =10 mm) inside the stent (71%) or focal (29%). Mean stent length was 16+/-7 mm. Balloon diameter of 2.98+/-0.37 mm and maximal inflation pressure of 10+/-3 atm were used for balloon angioplasty. Angiographic success rate was 100% without any complication. Acute gain was lower after balloon angioplasty for in-stent restenosis than after stent implantation: 1.19+/-0.60 mm vs. 1.75+/-0.68 mm (p=0.0002). At 6-month follow-up, 60% of patients were asymptomatic and no patient died. Eighteen patients (35%) had repeat target vessel revascularization. Angiographic restenosis rate was 54%. Recurrent restenosis rate was higher when in-stent restenosis was diffuse: 63% vs. 31% when focal, p=0.046. CONCLUSIONS: Although balloon angioplasty for in-stent restenosis can be safely and successfully performed, it leads to less immediate stenosis improvement than at time of stent implantation and carries a high recurrent angiographic restenosis rate at 6 months, in particular in diffuse in-stent restenosis lesions.  相似文献   

14.
BACKGROUND: Acute myocardial infarction is caused by sudden thrombotic occlusion of the coronary artery due to a previous rupture of atherosclerotic plaque. OBJECTIVE: To use intracoronary ultrasound measurements to evaluate lumen and plaque changes in patients with acute myocardial infarction. METHODS: Patients (n = 103) with acute myocardial infarction who had been scheduled to undergo primary percutaneous transluminal coronary angioplasty (PTCA) were selected. Both before and after successful coronary angioplasty, intracoronary 30 MHz ultrasound studies were performed using a 3.5F monorail catheter. The ultrasound catheter was successfully advanced into the occluded vessel segment without major complications prior to PTCA in 79 of 103 (76.7%) patients and after PTCA in 88 of 103 (85.3%) patients. RESULTS: The plaques were eccentric in 66 patients (83.5%). The plaque morphology was purely low echogenic in 14 (17.7%), highly echogenic in six (7.6%) and mixed in 59 (74.7%) patients. Partial (59 of 79, 74.7%) or ring-like calcification (3 of 79, 3.8%) was observed in 62 patients (78.5%). Plaque fissuring or dissection was detected prior to PTCA in 25 patients (31.7%). Coronary angioplasty successfully enlarged the inner luminal area from 2.1 +/- 0.7 to 7.4 +/- 1.9 mm2 (P < 0.01), whereas the plaque-thrombus area decreased significantly (13.8 +/- 1.7 mm2 before and 9.0 +/- 1.9 mm2 after PTCA; P < 0.01). The total vessel area remained virtually constant (15.9 +/- 1.9 mm2 before and 16.4 +/- 2.5 mm2 after PTCA, NS). PTCA-induced plaque rupture or dissection was observed in only 13 (16.5%) patients. CONCLUSION: Intracoronary ultrasound imaging can be performed safely and successfully prior and subsequent to PTCA in selected patients with acute myocardial infarction. Early reperfusion via PTCA seems to be attributable to a significant reduction in the amount of low-echogenic plaque and thrombus material, whereas factors like balloon-induced dissection and stretching of vessels play only a minor role.  相似文献   

15.
OBJECTIVE: Before balloon dilation, failure of compensatory enlargement and even arterial shrinkage are frequently observed at the lesion site in response to plaque accumulation. Balloon angioplasty may be regarded as artificial remodeling to enlarge the artery. The prevalence of the different types of arterial wall remodeling after applied stretch by balloon angioplasty is unknown. METHODS AND RESULTS: In 181 patients an intravascular ultrasound study was performed after coronary balloon angioplasty (n = 200 lesions). The vessel area was measured at a proximal and distal reference site and at the lesion site. Subsequently, the relative vessel area [(Vessel area lesion site)/Vessel area reference site) x 100] was calculated. Lesions were classified in three groups on the basis of their relative vessel areas: > or =105%, <105% but >95%, and < or =95%. A relative vessel area > or =105%, indicating enlargement compared with the reference site, was observed in 84 (44%) lesions. A relative vessel area <105% but >95% was observed in 43 (22%) lesions. A relative vessel area < or =95%, indicating "shrinkage" compared with the reference site, was observed in 66 (34%) lesions. CONCLUSIONS: After balloon angioplasty, the vessel area was found to be smaller compared with the reference site in 34% of the lesions. This small vessel area at the lesion site compared with a reference site may be a reflection of insufficient stretch by balloon angioplasty.  相似文献   

16.
OBJECTIVES: We aimed to investigate the impact of intravascular ultrasound (IVUS)-guided stent implantation on the 6-month restenosis rate, which has not yet been fully established in randomized trials. BACKGROUND: The 6-month angiographic restenosis rate was compared in patients with symptomatic ischemic heart disease who were randomly allocated to angioplasty and stent deployment, with versus without IVUS guidance. METHODS: After successful stent implantation, patients were randomized into two groups: Group A had no further dilation, and Group B had additional balloon dilation until achievement of IVUS criterion for stent expansion. The study group consisted of 164 patients, assuming a 50% reduction of the restenosis rate in Group B (15% vs. 30%) (alpha = 10%, beta = 20%). RESULTS: We enrolled 155 patients. Overdilation was carried out in 31 (39%) of 79 Group B patients, with the IVUS criterion being achieved in 63 (80%) of 79. No significant difference was observed in the minimal luminal diameter (MLD), but the stent lumen cross-sectional area (CSA) was significantly larger in Group B (mean +/- SD) (7.16 +/- 2.48 vs. 7.95 +/- 2.21 mm2, p = 0.04). At 6 months, there was no significant difference in the restenosis rate, (28.8% [21 of 73] in Group A vs. 22.5% [16 of 71] in Group B, p = 0.25), but according to the observed difference in the restenosis rate, the power of the study was only 40%. The difference in MLD was also nonsignificant (1.60 +/- 0.65 mm in Group A vs. 1.70 +/- 0.64 mm in Group B, p = 0.20), whereas the lumen CSA was 20% larger in the IVUS-guided group (4.47 +/- 2.59 vs. 5.36 +/- 2.81 mm2, p = 0.03). Lumen CSA was the only predictor of restenosis by multivariate logistic regression analysis. CONCLUSIONS: A nonsignificant 6.3% absolute reduction in the restenosis rate and a nonsignificant difference in MLD were observed in this study. Nonetheless, we still cannot rule out a beneficial effect of IVUS guidance, although this may have gone undetected owing to a lack of statistical power. A significant increase was observed in immediate and 6-month lumen size, as detected by IVUS, indicating that ultrasound guidance in stent deployment may be beneficial.  相似文献   

17.
Therapies that inhibit intimal hyperplasia do not prevent restenosis after coronary artery balloon angioplasty, suggesting that additional mechanisms may be responsible for restenosis in humans. Using an intravascular ultrasound (Hewlett-Packard Sonos Intravascular Imaging System). 3.5F, 30-MHz (Boston Scientific) monorail imaging catheter, we studied 17 patients with clinical and angiographic restenosis at an average (mean +/- SD) of 7 +/- 6 months after balloon angioplasty (13 men age, 71 +/- 10 years; 12 left anterior descending coronary arteries, 4 right coronary arteries, and 1 left circumflex coronary artery) The lumen area (L.A), vessel wall area (VWA), and total cross-sectional area (CSA) within the external elastic lamina were measured at the restenosis site and at proximal and distal reference sites, which were defined as adjacent segments with the least amount of plaque. Consistent with coronary angiography findings, decreased LA at the restenotic site was detected in all 17 patients. The unique finding was that total CSA at the restenotic site was significantly decreased compared with both proximal and distal reference sites (10.1 +/- 2.4 versus 14.8 +/- 3.2 mm2 and 10.1 +/- 2.4 versus 13.8 +/- 3.1 mm2, respectively, P < .001), whereas VWA (intima plus media) was slightly increased at the angioplasty site compared with both proximal and distal reference sites (8.0 +/- 2.3 versus 7.6 +/- 2.3 mm2 and 8.0 +/- 2.3 versus 6.7 +/- 2.3 mm2, respectively, P = NS). Eighty-three percent of the loss in LA at the restenotic site was due to constriction of the total CSA, while the increase in VWA at the restenotic site accounted for only a 17% loss in LA. We then compared these results with the morphology of coronary artery segments in 14 patients without restenosis. These coronary artery segments had been previously treated with balloon angioplasty (7 +/- 5 months). Unlike that in restenotic lesions, the total CSA within the external elastic lamina at the sites of previous angioplasty was similar to that in distal and proximal reference sites (P = NS). Significant and consistent reduction in arterial CSA, with a minor increase in VWA, characterizes human coronary lesions that cause angiographic restenosis. These data suggest that in humans, "recoil" and/or vascular contraction with healing in response to balloon injury is a major contributor to restenosis after balloon angioplasty.  相似文献   

18.
OBJECTIVE: Remodeling in de novo atherosclerosis and in restenosis after balloon angioplasty constitutes a change in total arterial circumference which, together with plaque growth or neointimal formation, determines the lumen of the artery. To better understand the fundamental biology of neointimal formation, remodeling and their interaction, animal studies are needed. In this study, we described in detail the methodology used and the natural history of neointimal formation and remodeling after balloon angioplasty in atherosclerotic Yucatan micropigs. METHODS AND RESULTS: Atherosclerosis was induced in 60 peripheral arteries of sixteen Yucatan micropigs by a combination of denudation and atherogenic diet. Balloon angioplasty was performed in 38 arteries, with serial intravascular ultrasound (IVUS) and quantitative angiography before and after intervention and at 2, 4, 7, 14 or 42 days follow-up. Remodeling, expressed as late media-bounded area (MBA) loss, increased progressively over time. At 42 days, late MBA loss after balloon angioplasty was significantly different compared to late MBA loss in control arteries, 2.2 +/- 1.0 versus -0.3 +/- 1.1 mm2 and p = 0.02. Late lumen loss increased over time and was highest at 42 days after balloon angioplasty (2.8 +/- 0.7 mm2). The contribution of neointimal formation to late lumen loss decreased over time and the contribution of late MBA loss to late lumen increased over time and was highest at 42 days (78%). Medial necrosis was 48% at two days after balloon angioplasty and the repopulation of the media was almost completed at seven days. CONCLUSION: Remodeling following balloon angioplasty has an early onset and progresses with neointimal formation to cause restenosis over the standard 42-day time course for Yucatan micropigs. This correlates to six months renarrowing in humans. In this model, atherosclerosis and the natural history of restenosis, both with respect to neointimal formation and remodeling, resemble the human disease quite closely.  相似文献   

19.
Percutaneous transluminal balloon angioplasty (PTA) of superficial femoral artery lesions is associated with similar initial success rates in coronary and iliac artery angioplasty but its application is limited by a much higher incidence of restenosis. To improve understanding of the trauma caused to the vessel by balloon angioplasty and the mechanisms contributing to the subsequent processes of healing and restenosis requires serial investigations of the treated arteries in vivo. This paper describes a prospective study using colour duplex ultrasonic imaging to assess arterial changes in 51 patients with atherosclerotic disease undergoing PTA of superficial femoral artery stenoses and occlusions. Each patient was scanned prior to angioplasty and at intervals up to 6 months post-angioplasty. On each scan, measurements were made of the overall vessel and lumen diameters at each site of angioplasty. These measurements indicate that angioplasty improves vessel patency mainly by stretching of the vessel wall, with compression and/or redistribution of the atherosclerotic plaque contributing less than 25% to the improvement of lumen diameter. Serial measurements after angioplasty show complex patterns of change at the angioplasty sites indicating that several mechanisms may be contributing to the processes of vessel healing and subsequent restenosis. Possible mechanisms which could explain the measured changes in overall vessel and lumen diameters are discussed.  相似文献   

20.
Intravascular ultrasound (IVUS) imaging was used to measure internal luminal area immediately after percutaneous transluminal coronary angioplasty (PTCA) in 83 patients (59 males, 24 females, mean age 63 +/- 12 years) with angina pectoris to determine the need for additional intervention. The effectiveness of these interventions to prevent restenosis was also studied. Thirty-five patients (42%) with insufficient dilatation revealed an internal luminal area less than 5 mm2 or luminal stenosis greater than 60% as evaluated by IVUS imaging following the procedure. The luminal area increased from 4.5 +/- 1.1 to 7.9 +/- 2.8 mm2 and the percentage luminal stenosis improved from 66 +/- 9% to 54 +/- 9% in patients who underwent further dilatation with a larger size balloon, longer dilatation time, directional coronary atherectomy, or stenting. The insufficient dilatation group exhibited hard plaque and calcification more frequently than in the other group (48 patients, 58%) in whom sufficient dilatation of the target lesion was achieved. The incidence of restenosis in the sufficient dilatation group was 25%, compared to 33% of the patients receiving additional treatment after IVUS imaging and 42% in the 192 patients who underwent PTCA without IVUS imaging. IVUS imaging is a useful method for evaluation of complex luminal morphology to decrease the incidence of restenosis and for determination of the end point and the extent of dilatation required.  相似文献   