首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
To reduce the residual organic matter and phosphorus contained in secondary effluent, a biofiltration system combined with electrocoagulation using bipolar iron electrodes was evaluated as a supplementary treatment to existing small-community sewage treatment. Based on the results of batch tests, bipolar electrocoagulation (BEC) was found to be more effective on phosphorus removal than monopolar electrocoagulation (MEC) but energy consumption was less in monopolar electrocoagulation. Optimum conditions of BEC to treat the secondary effluent were current density 15 A/m2, electrode spacing 1 cm and pH < 8. The removals of COD(Cr) and phosphorus by biofiltration system without BEC were 69.1% and 9.6%, respectively. However, biofiltration system combined with BEC showed 76.6-83.7% and 70.7-93.0% removal for COD(Cr) and phosphorus respectively. Extraordinary increase in phosphorus could be achieved by introducing electrocoagulation to biofiltration, and BEC/biofiltration system was evaluated to be applicable to existing small-community sewage treatment plants as a supplementary process.  相似文献   

2.
Pretreatment of an acid dyebath effluent bearing a new generation chromium complex azo dyestuff (C0 = 350 mg/L) with Fenton's reagent was investigated. Preliminary optimisation (baseline) experiments were conducted to determine the Fe2+, H2O2 concentrations and pH required to the highest possible COD and colour removals. Kinetic studies were carried out at varying temperatures (20 degrees C < T < 70 degrees C) to establish a relationship between COD abatement and H2O2 consumption. The activation energy found for catalytic H2O2 decomposition (Ea = 9.8 kJ/mol) appeared to be significantly less than that of fermentative (Ea = 23 kJ/mol) and of thermal (Ea = 76 kJ/mol) H2O2 decomposition, implying that H2O2 decomposition during the Fenton's reaction occurs more spontaneously. The experimental studies indicated that approximately 30% COD and complete colour removal could be achieved under optimised Fenton pretreatment conditions (Fe2+ = 2 mM; H2O2 = 30 mM; pH = 3; at T = 60 degrees C). Long-term activated sludge experiments revealed that although the raw and pretreated acid dyebath effluent contained practically the same amount of "readily biodegradable" COD (inert COD fraction < or = 10%), biodegradation of the chemically pretreated acid dye effluent proceeded appreciably faster than that of the untreated acid dyebath effluent.  相似文献   

3.
This paper explores the use of electrocoagulation to remove boron from waste effluent in comparison with alum coagulation. In treating model test wastes, greater boron removals were achieved with electrocoagulation at low doses than conventional alum coagulation when reaction was undertaken for the same conditions (pH 8.5, and initial boron concentration was 500 mg/L). Al electrocoagulation can achieve good boron removal performance (68.3%) at a dose of 2.1 (as molar ratio of Al:B, and for current density of 62.1 A/m2), while alum coagulation can only achieve the maximum boron removal of 56% at a dose of 2.4. Also, Al electrocoagulation can remove 15-20% more boron than alum coagulation for the same dose compared in the treatment of both model test wastes and industry effluent. The estimation of running costs shows that to achieve 75% boron removal from industry waste effluent, i.e. removing 150 g of boron from 1 m3 of effluent, electrocoagulation was 6.2 times cheaper than alum coagulation. The economic advantage of electrocoagulation in the treatment of boron-containing waste effluent is thus significant.  相似文献   

4.
The present work describes an experimental study carried out in order to investigate the efficiency and feasibility of physical (lime coagulation) and advanced oxidation processes (Ozone and Fenton's process) for olive oil mill wastewater treatment. Particular attention was paid to the degradation of both organic and phenolic compounds. Lime coagulation reaches maximum removal at a pH of 12, with a TP (total polyphenols) and COD reduction of 37 and 26%, respectively. Ozone oxidation is also pH-dependent, showing the higher removal efficiency (91% for TP and 19% for COD) with an initial pH value of 12. Experimental results show a lower efficiency of Fenton's process than ozone in TP removal, reaching a maximum value of 60%. Oxidation trials carried out on gallic and p-coumaric synthetic solutions confirmed ozone and Fenton's efficiency at degrading phenolic compounds. Biological trials, both aerobic and anaerobic, highlighted a significant increase of biodegradability of treated OMW samples if compared to the untreated ones. Respirometric tests showed an increase in BOD of about 20% and anaerobic batch tests provided a methane production up to eight times higher.  相似文献   

5.
焦跃腾  顾正华  丁昊  周欣 《人民长江》2017,48(21):23-28
电絮凝作为一种具有广泛应用前景的低廉高效污水处理技术,已经被证明在工业废水、生活污水等污染严重的水体处理上具有显著效果,但是目前对于电絮凝净化微污染水的相关研究较少。通过对电絮凝分批处理河水的实验研究,分析电絮凝方法处理微污染水的可行性,讨论极板间距的改变对电絮凝处理效果的影响。结果表明,电絮凝处理技术可以用于微污染水净化中,在电流密度为17.75 A/m2、极板间距为1.5 cm的条件下,反应30 min时,色度去除率为73.76%,浊度去除率为76.00%,悬浮固体去除率为85.71%,化学需氧量去除率为42.86%,总磷去除率为61.36%。在电絮凝反应中,极板间距对于微污染水的色度、浊度、悬浮固体和总磷去除效果具有明显的影响。  相似文献   

6.
A combination of coagulation and Fenton's process was used for the removal of total oxygen carbon (TOC) from oilfield wastewater. Compared with aluminium sulfate, ferric coagulant had better TOC removal efficiency at the same mass dosage. In Fenton's process, the effect of H2O2 and Fe2+ dose on the removal of TOC was studied. The optimum conditions required for TOC removal were an Fe3+ concentration of 40-50 mg/L, an H2O2 dose of 50 mmol/L and an Fe2+ concentration of 1.0 mmol/L. GC-MS chromatographic analysis indicated that most of the alkyl hydrocarbons of carbon numbers < 21 were removed in the first minute of Fenton's process mainly through adsorption. Alkyl hydrocarbons and phenols were oxidized almost completely following 120 min of treatment. The pathway of newly formed intermediates in Fenton's process was proposed on the basis of the GC/MS chromatogram.  相似文献   

7.
In this study a poorly biodegradable (BOD/COD = 0.3) industrial alkaline ECF bleaching filtrate was treated using different advanced oxidation processes to evaluate their use in combined chemical-biological treatment aimed at increasing recalcitrant COD removal and improving final effluent quality. Oxidative treatments included ozonation combined with hydrogen peroxide (2, 5, 10, 20 mmol L(-1) O3/0.7, 2, 5, 10 mmol L(-1) H2O2) and photocatalysis with hydrogen peroxide (UV/2, 4 and 8 mmolL(-1) H2O2) and with TiO2 (UV/TiO2/0.7 and 4 mmol L(-1) H2O2). The O3/H2O2 process increased effluent biodegradability by up to 68% as a result of increasing BOD and decreasing COD. Increasing the O3 dose had a greater effect on biodegradability improvement and lignin and colour removal efficiencies than increasing the H2O2 dose. A combined oxidant dose of 5 mmol L(-1) O3 and 2 mmol L(-1) H2O2 resulted in 75% lignin removal, 40% colour removal and 6% carbohydrate loss without mineralizing the organic carbon. The photocatalytic processes led to a decrease in effluent biodegradability through combined decrease in BOD and increase in COD and did not result in efficient lignin or colour removal. Photocatalytic oxidation was apparently inhibited by the high chloride and COD levels in the alkaline filtrate, and may be more efficient in recalcitrant COD removal if performed after biological.  相似文献   

8.
In this study, the effects of the phosphonic acid based sequestering agent EDTMPA used in the textile dye baths on colour and organic matter removal by ozone oxidation was experimentally investigated. Procion Navy HEXL dyestuff that has been commonly used for the reactive dyeing of cellulose fibers was selected as the model component. The organic matter oxidation by ozone was determined to obey the pseudo-first order kinetics as they are treated singly or in combination. COD removal rates obtained from pseudo-first order reaction kinetics showed that oxidation of Navy HEXL alone (0.0947 L/min) was faster than that of EDTMPA (0.0171 L/min) and EDTMPA with dye (0.0155 L/min) at pH 3.0. It was also found that reaction rates of single EDTMPA removal and EDTMPA and dye mixture removal increased as the reaction pH was increased from 3.0 to 10.5.  相似文献   

9.
This paper presents a preliminary study for the removal of COD and suspended solids in wastewater treatment by combining magnetic field and electrocoagulation (EC) technology. The experiments were carried out using batch apparatus and setup in the static method. Batch experiments with two monopolar iron (Fe) plate anodes and cathodes were employed as electrodes. Wastewater samples were prepared from milk powder with an initial COD of 1,140 mgL(-1) and suspended solids of 1,400 mgL(-1) and acidic conditions were employed (pH approximately 3). DC current was varied from 0.5-0.8 A and operating times were between 30 and 50 min. The results show that the effluent wastewater was very clear (turbidity approximately 9 NTU) and its quality exceeded the direct discharge standard. The suspended solids and COD removal efficiencies were as high as 30.6 and 75.5%, respectively. In addition, the experimental results also show that the electrocoagulation could neutralise the pH of wastewater.  相似文献   

10.
In treating textile wastewater, the application of membrane bioreactor (MBR) technology showed high efficiency in COD and BOD5 removal. However, insufficient colour removal was achieved for possible reuse. The aim of the work presented in this paper was to test the performance of chemical advanced oxidation on the elimination of the colour downstream of an MBR. To improve the quality of the membrane bioreactor effluent three different oxidation treatments were tested at lab-scale: ozonation, chlorination and hydrogen peroxide oxidation. Colour, COD and BOD5 were controlled in order to assess the effectiveness of each process. For chlorination, even with 250 mg/L (active chlorine) only 80% colour removal (SACin = 14; SACout = 2.8) was achieved which is considered unsatisfactory. For hydrogen peroxide, the colour removal was even poorer; it was just 10% at a concentration of 250 mg/L. In contrast, good results were obtained by ozonation. By using only 38 mg/L within 20 minutes, it was possible to achieve the reuse recommendation with a satisfactory colour removal of 93% (SACin = 14; SACout = 0.98). The results showed that ozonation was the most promising method.  相似文献   

11.
电絮凝处理黄土塬地区村镇集蓄雨水的实验研究   总被引:1,自引:0,他引:1  
采用电凝聚对黄土塬地区村镇集蓄雨水进行处理。通过改变极板间距、极板电压、电解时间,进行了对集雨水中COD,浊度,NH3-N,UV254的去除率研究。结果表明:电解时间15 min,极板间距为10 mm,极板电压为15 V的条件下,电絮凝对集蓄雨水中浊度、氨氮、UV254、COD有较好的去除效果,去除率分别为95%、63%、48%、80%,高于化学絮凝的处理效果。  相似文献   

12.
高浓度焦化废水的预氧化-混凝处理研究   总被引:3,自引:0,他引:3  
焦化废水成分十分复杂,污染物浓度高,性质非常稳定且水量大,是典型的难降解有机废水。使用H2O2为氧化剂,FeSO4.7H2O为催化剂的Fenton氧化法对钢铁焦化厂废水的终冷水进行了试验研究,氧化处理后用FeCl3为混凝剂对COD,NH3-N,色度及浊度的去除率进行了系统的考查。确定了氧化反应的影响因素和最佳的混凝实验条件。结果表明:当pH值控制在3左右,反应时间为30 min,反应温度为80℃,焦化废水的COD,NH3-N,浊度和色度去除率分别达到了93.1%,96.2%,90.8%和90.2%。  相似文献   

13.
In this study, treatment of slaughterhouse wastewater by electrocoagulation was investigated in batch system using Fe electrodes. The effect of various variables such as electrode number, current density and operating time was tested. Pollutant removal efficiency increased with increasing electrode number and operating time. The biochemical oxygen demand (BOD(5))(,) chemical oxygen demand (COD), total suspended solid (TSS), and total nitrogen (TN) removal efficiencies using eight electrodes at a contact time of 50 min and a current density of 10 A/m(2) were 66, 62, 60, and 56%, respectively. Higher electrode numbers will allow shorter operating times to achieve certain removal efficiencies. Also, removal efficiencies increased by increasing the current density; the highest removal efficiencies of BOD(5,) COD, TSS, and TN at a contact time of 50 min and a current density of 25 A/m(2) were 97, 93, 81, and 84%, respectively. The results also show that the reactor pH varies directly with the current density; at 25 A/m(2), the reactor pH increased from an initial value of 7.1 to 7.7 after 50 min. The experimental results showed that the kinetics of BOD(5), COD, TSS and TN removal could be fitted adequately using a first order kinetic model (higher R(2)).  相似文献   

14.
This work aims to investigate removal efficiency of oxidation and coagulation/flocculation processes, to provide an effective method for the treatment of biologically pre-treated leachate. Leachate containing 985 mg L(-1) COD was treated by using three treatment schemes, i.e. oxidation, coagulation/flocculation and the combined process of coagulation/flocculation followed by oxidation. The application of single oxidation resulted in the effective removal of COD and color up to 80.4 and 83.2%, respectively. However, residual COD values lower than 200 mg L(-1) could only be achieved under intensive experimental conditions (high dosage of Ca(ClO)(2) and prolonged oxidation time). Coagulation/flocculation yielded residual COD values higher than 200 mg L(-1) even at the optimum coagulation conditions. The combined treatment by coagulation/flocculation followed by oxidation yielded final COD lower than 100 mg L(-1) at the following conditions: pre-coagulation with 250 mg L(-1) PFS (poly-ferric sulfate) and over 30-min post-oxidation, or pre-coagulation with 300 mg L(-1) PFS and over 20-min post-oxidation. Hence, pre-coagulation with PFS followed by oxidation with Ca(ClO)(2) was recommended for advanced treatment of biologically treated leachate.  相似文献   

15.
采用湿式氧化技术处理在生产磺胺间二甲氧嘧啶过程中产生的高浓度有机废水。在反应温度为250℃,初始ρ(COD)为4 575 mg/L,反应时间为2 h,pH值为7~8时,采用湿式双氧水氧化和催化湿式氧化,COD去除率分别为78.3%和92.0%,表明催化湿式氧化具有较好的COD去除效果。同时考察了催化湿式氧化中反应温度、反应时间、废水pH值对COD去除率的影响。  相似文献   

16.
In recent years, electrocoagulation has been successfully used for wastewater treatment and is efficient in heavy metal ions removal. In the present work, electrocoagulation has been used for the removal of Hg(II) from synthetic wastewaters containing up to 20 mg/L of mercury. The electrode materials used are stainless steel (SS) and aluminum (Al). The effects of operating parameters, viz., current density, time of electrocoagulation, distance between electrodes, initial pH of the solution, presence of electrolyte in the solution and temperature have been studied. It was observed that more than 99% Hg(II) removal can be achieved by keeping the distance between SS and Al electrodes from 2 to 6 cm and initial pH range from 3 to 7. The results show that the pseudo second-order kinetics fits the data well. Also, preliminary cost estimation was reported.  相似文献   

17.
Landfill leachates are a problematic wastewater due to their variable concentration, volume changing in time and presence of refractory and hazardous components. In this paper, the results of a new approach to photocatalysis assisted by biological process for the detoxification of stabilised landfill leachate are presented. The biologically pre-treated leachate still contained a significant amount of non-biodegradable COD and TOC amounting to 500 and 200 mg/L, respectively. The 300 min of photocatalytic treatment (UVC/TiO2) brought about a significant decrease in more than 80% refractory organics remaining in leachate. The effect of pH and catalyst loading on mineralisation, colour removal rate and biodegradability (BOD/COD) improvement in the photoreactor were discussed. The bio-accessibility of formed photocatalytic oxidation intermediates was confirmed by oxygen uptake rate (OUR) measurements. Consequently, a part of COD was successfully removed in post-biological treatment.  相似文献   

18.
This paper presents results from exploratory experiments to test the technical feasibility of electrolytic treatment and coagulation followed by flocculation and sedimentation as post-treatment for the effluent of an UASB reactor treating simulated wastewater from an unbleached Kraft pulp mill. The electrolytic treatment provided up to 67% removal of the remaining COD and 98% of color removal. To achieve these efficiencies the energy consumption ranged from 14 Wh x l(-1) to 20 Wh x l(-1). The coagulation-flocculation treatment followed by settling required 350-400 mg x l(-1) of aluminium sulfate. The addition of a high molecular weight cationic polymer enhanced both COD and color removal. Both post-treatment processes are technically feasible.  相似文献   

19.
The removal of detergents from clarified wastewaters by activated petroleum coke (CAPA) was assessed. These substances, owing to their foamy properties, constitute a problem for ammonia removal by the air stripping process that could be installed in a wastewater treatment train to produce reclaimed water. CAPA was evaluated as a more economical alternative than a commercial activated carbon. Experimental work was divided in three stages: 1) production and characterisation of materials; 2) pretreatment of raw wastewater through the Fenton's reagent or coagulation-flocculation process with Al2(SO4)3; and 3) adsorption and bio-adsorption tests of clarified effluents. These tests were carried out in the laboratory in discontinuous and continuous reactors, the former by the "point-by-point" technique, with and without a previous fixing of bacteria, and the latter by the Rapid Small Scale Column Test. Detergents content, color, COD and UV254nm were measured in raw and treated wastewaters. Results show that the best pretreatment for the adsorption process was coagulation-flocculation rather than Fenton's method. Oxidation by this process decreased the adsorptive properties of detergents. Biomass fixed on the CAPA particles significantly increased the UV254nm and COD removal efficiencies (20% and 170% respectively). The breakthrough curves showed that CAPA could attain the expected detergents removal efficiency (66%) for the alum effluent.  相似文献   

20.
The objective of this work was to evaluate the semi-continuous post-treatment of anaerobically-pre-treated weak black liquor (anaerobic effluent, AnE) by aerobic post-treatment using hybrid pellets of Trametes versicolor. The latter consisted of fungus immobilized onto holm oak sawdust (mixed or double pellets) or a mixture of holm oak sawdust and powdered activated carbon (triple pellets). First, a semicontinuous experiment was run to compare the effectiveness of triple and mixed pellets in agitated flasks for 15 cycles of 7 days each. A second extended batch test was implemented with 500 mL AnE and triple pellets to give 400 mg fungal biomass; some units were spiked with protease inhibitor. In the first experiment, triple pellets displayed consistently higher removal efficiencies of pollutant parameters than double pellets (10 to 15% higher), although overall averages were moderate and no statistical significance to the difference could be set because of the noise of fluctuations. Periodic fluctuations of removal were characterized by three periods of approximately six cycles each with maximum removals occurring at cycles 3-4, 7-9, 13, and 14. Evaluating pooled removals of the latter cycles showed that triple pellets were significantly more effective than double pellets, with removal efficiencies as high as 47% of COD, colour, and absorbance at 254 nm (A254). In general, protease activity seemed to increase in the third period (last six cycles), whereas activities of MnP, LiP and Lac significantly decreased. In the second experiment, pollutant removals and enzymatic activities of triple pellets with protease inhibitor were significantly higher than those of units without added protease inhibitor. These results indicate that protease could be the main cause of periodic falls of pollutant removal efficiencies found in the first experiment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号