首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The purpose of this study was to analyze, by confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM), the morphology of sealant/enamel interface after surface treatment with Biosilicate. Before pits and fissures sealing, the occlusal surfaces of 10 sound human molars were sectioned perpendicularly at the fissures in order to obtain three slices for each tooth. Slices were randomly assigned into three groups (n = 10) according to sealing protocol: Group 1‐ Acid etching + Biosilicate + glass ionomer‐based sealant (Clinpro XT Varnish, 3M ESPE); Group 2‐ Acid etching + glass ionomer‐based sealant (Clinpro XT Varnish, 3M ESPE); Group 3‐ No sealing. All slices were subjected to thermal cycling (5,000 cycles; 5–55°C; dwell time: 30s). Half of the slices from each group (n = 5) were analyzed by CLSM and the other half by SEM. Groups 1 and 2 were also submitted to EDS analysis and their data were evaluated by Two‐Way ANOVA e Tukey's test (α=5%). EDS data analysis showed higher amounts of silicon (Si) ions than calcium (Ca) ions in Group 1 (P < 0.05); Group 2 presented higher amounts (P < 0.05) of Ca ions than Si ions. It may be concluded that the use of Biosilicate for surface treatment did not affect the morphology of glass ionomer‐based sealant/enamel interfaces. Microsc. Res. Tech. 78:1062–1068, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

2.
This study evaluated the effects of chemical agents on the physical properties and structure of primary pulp chamber dentin using surface roughness, microhardness tests, and scanning electron microscopy (SEM). Twenty‐five primary teeth were sectioned exposing the pulp chamber and were divided into five groups (n = 5): NT, no treatment; SH1, 1% sodium hypochlorite (NaOCl); SH1U, 1% NaOCl + Endo‐PTC®; SH1E, 1% NaOCl + 17% EDTA; and E, 17% EDTA. After dentin treatment, the specimens were submitted to roughness, microhardness testing, and SEM analysis. Roughness and microhardness data were submitted to one‐way ANOVA and Tukey's test (P < 0.05). The SH1E group showed the highest roughness, followed by the E group (P < 0.05) when compared with the NT, SH1, and SH1U groups. Microhardness values of SH1 and SH1U showed no significant difference as compared to the NT (control) group (P > 0.05). Microhardness values could not be obtained in the EDTA groups (SH1E and E). The presence of intertubular dentin with opened dentin tubules was observed in the NT, SH1, and SH1U groups. SH1E showed eroded and disorganized dentin with few opened tubules and the intertubular/peritubular dentin was partially removed. Considering the physical and structural approaches and the chemical agents studied, it can be concluded that NaOCl and NaOCl associated with Endo‐PTC® were the agents that promoted the smallest changes in surface roughness, microhardness, and structure of the pulp chamber dentin of primary teeth. Microsc. Res. Tech. 77:52–56, 2014. © 2013 Wiley Periodicals, Inc.  相似文献   

3.
Preservation of enamel during composite veneer restorations of fluorosed teeth could be achieved by conservative preparation with Erbium lasers. This study evaluated the effect of fluorosed enamel preparation with Er,Cr:YSGG vs. conventional diamond bur on the micromorphology and bond strength of a self‐etch and an etch‐and‐rinse adhesives. Er,Cr:YSGG laser or diamond bur preparation was performed on the flattened midbuccal surfaces of 70 extracted human premolars with moderate fluorosis (according to Thylstrup and Fejerskov index, TFI = 4–6). Adper Single Bond (SB) with acid etching for 20 or 40 s and Clearfil SE Bond (SEB) alone or with additional etching was applied in four laser groups. The same adhesive procedures were used in three bur groups except for 40 s of etching along with SB. After restoration, microshear bond strength was measured (MPa). Data were analyzed using ANOVA and Tamhane tests (α = 0.05). Six additional specimens were differently prepared and conditioned for scanning electron microscopy evaluation. The highest and lowest bond strengths were obtained for bur‐prepared/SB (39.5) and laser‐prepared/SEB (16.9), respectively, with a significant difference (P = 0.001). The different adhesive procedures used associated to two adhesives exhibited insignificantly lower bonding in laser‐prepared groups compared to bur‐prepared ones (P > 0.05), with the exception of additional etching/SEB, which bonded significantly higher to bur‐prepared (36.4) than to laser‐prepared enamel (18.7, P = 0.04). Morphological analyses revealed a delicate etch pattern with exposed enamel prisms on laser‐prepared fluorosed enamel after acid etching and less microretentive pattern after self‐etching primer. The etch‐and‐rinse adhesive was preferred in the laser‐prepared fluorosed enamel in terms of bonding performance. Microsc. Res. Tech. 77:779–784, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

4.
The aim of this study was to compare different bacterial models for in vitro induction of non‐cavitated enamel caries‐like lesions by microhardness and polarized light microscopy analyses. One hundred blocks of bovine enamel were randomly divided into four groups (n = 25) according to the bacterial model for caries induction: (A) Streptococcus mutans, (B) S. mutans and Lactobacillus acidophilus, (C) S. mutans and L. casei, and (D) S. mutans, L. acidophilus, and L. casei. Within each group, the blocks were randomly divided into five subgroups according to the duration of the period of caries induction (4–20 days). The enamel blocks were immersed in cariogenic solution containing the microorganisms, which was changed every 48 h. Groups C and D presented lower surface hardness values (SMH) and higher area of hardness loss (ΔS) after the cariogenic challenge than groups A and B (P < 0.05). As regards lesion depth, under polarized light microscopy, group A presented significantly lower values, and groups C and D the highest values. Group B showed a higher value than group A (P < 0.05). Groups A and B exhibited subsurface caries lesions after all treatment durations, while groups C and D presented erosion‐type lesions with surface softening. The model using S. mutans, whether or not it was associated with L. acidophilus, was less aggressive and may be used for the induction of non‐cavitated enamel caries‐like lesions. The optimal period for inducing caries‐like lesions was 8 days. Microsc. Res. Tech. 78:444–451, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

5.
The aim of the study was to determine the efficacy of different products containing fluoride, calcium and phosphate for enamel remineralization in eroded primary teeth. A total of 90 sound primary canine teeth were randomly divided into 5 groups of 18 teeth each: 1) control (polished enamel), 2) 5% DuraShield sodium fluoride varnish, 3) 500 ppm fluoridated toothpaste, 4) casein phosphopeptide‐amorphous calcium phosphate (CPP‐ACP) cream, and 5) Clinpro White varnish containing functionalized tri‐calcium phosphate (fTCP). Enamel microhardness (EMH) was measured in all samples before and after demineralization and after 28 days of remineralization. Also 8 samples in groups 2 to 5 and four samples of sound and demineralized enamel were examined with atomic force microscopy (AFM). All data were analyzed with one‐way ANOVA (p<0.05). Mean microhardness of demineralized enamel was significantly lower than in enamel at baseline (p<0.001). Remineralization significantly increased microharness in groups 2 to 5 compared to the control group (p<0.001). Percent EMH after remineralization with CPP‐ACP was significantly higher than after fTCP (p=0.029), toothpaste (p< 0.001) or fluoride varnish (p<0.001); however, there was no significant difference between toothpaste and fluoride varnish (p=0.062). Microhardness increased more after fTCP treatment than after treatment with sodium fluoride varnish (p<0.001) or fluoridated toothpaste (p=0.045). AFM images showed that enamel roughness decreased most after treatment with fTCP, followed by CPP‐ACP, toothpaste and fluoride varnish. The efficacy of CPP‐ACP cream for remineralizing eroded enamel was greater than fluoride toothpaste, fluoride varnish or fTCP varnish. Microsc. Res. Tech. 78:801–806, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

6.
The aim of the this study was to quantitatively evaluate in three‐dimensional (3D), the porosity degree of three improved silicate‐based endodontic repair cements (iRoot BP Plus®, Biodentine®, and Ceramicrete) compared to a gold‐standard calcium silicate bioactive cement (Pro Root® MTA). From each tested cement, four samples were prepared by a single operator following the manufacturer's instructions in terms of proportion, time, and mixing method, using cylindrical plastic split‐ring moulds. The moulds were lubricated and the mixed cements were inserted with the aid of a cement spatula. The samples were scanned using a compact micro‐CT device (Skyscan 1174, Bruker micro‐CT, Kontich, Belgium) and the projection images were reconstructed into cross‐sectional slices (NRecon v.1.6.9, Bruker micro‐CT). From the stack of images, 3D models were rendered and the porosity parameters of each tested material were obtained after threshold definition by comparison with standard porosity values of Biodentine®. No statistically significant differences in the porosity parameters among the different materials were seen. Regarding total porosity, iRoot BP Plus® showed a higher percentage of total porosity (9.58%), followed by Biodentine® (7.09%), Pro Root® MTA (6.63%), and Ceramicrete (5.91%). Regarding closed porosity, Biodentine® presented a slight increase in these numbers compared to the other sealers. No significant difference in porosity between iRoot BP Plus®, Biodentine®, and Ceramicrete were seen. In addition, no significant difference in porosity between the new calcium silicate‐containing repair cements and the gold‐standard MTA were found. Microsc. Res. Tech., 76:1093–1098, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

7.
Universal adhesives have been recently introduced for use as self‐etch or etch‐and‐rinse adhesives depending on the dental substrate and clinical condition. However, their bonding effectiveness to laser‐irradiated enamel is still not well‐known. Thus, the aim of this study was to compare the shear bond strength (SBS) of universal adhesives (Single Bond Universal; Nova Compo‐B Plus) applied to Er,Cr:YSGG laser‐irradiated enamel with SBS of the same adhesives applied in self‐etch and acid‐etching modes, respectively. Crown segments of sixty bovine incisors were embedded into standardized acrylic blocks. Flattened enamel surfaces were prepared. Specimens were divided into six groups according to universal adhesives and application modes randomly (n = 10), as follows: Single Bond Universal/acid‐etching mode; Nova Compo‐B Plus/acid‐etching mode; Single Bond Universal/self‐etching mode; Nova Compo‐B Plus/self‐etching mode; and Single Bond Universal/Er,Cr:YSGG Laser‐etching mode; Nova Compo‐B Plus/Er,Cr:YSGG Laser‐etching mode. After surface treatments, universal adhesives were applied onto surfaces. SBS was determined after storage in water for 24 h using a universal testing machine with a crosshead speed of 0.5 mm min?1. Failure modes were evaluated using a stereomicroscope. Data was analyzed using two‐way of analyses of variances (ANOVA) (p = 0.05). Two‐way ANOVA revealed that adhesive had no effect on SBS (p = 0.88), but application mode significantly influenced SBS (p = 0.00). Acid‐etching significantly increased SBS, whereas there are no significant differences between self‐etch mode and laser‐etching for both adhesives. The bond strength of universal adhesives may depend on application mode. Acid etching may significantly increase bond strength, while laser etching may provide similar bond strength when compared to self‐etch mode.  相似文献   

8.
The aim of this study was to evaluate radiographically and histologically the pulpal and periapical response to self‐adhesive (Rely X? Unicem) and self‐etching and self‐curing (Multilink®) resin‐based luting materials in deep cavities in dogs' teeth. Deep class V cavities (0.5‐mm–thick dentin) were prepared in 60 canine premolars and the following materials were applied on cavity floor: Groups I/V—RelyX? Unicem; Groups II/VI—Multilink®; Groups III/VII—zinc phosphate cement (control) and; Groups IV/VIII—gutta‐percha (control). Cavities were restored with silver amalgam. Animals were euthanized after 10 days (groups I–IV) and 90 days (groups V–VIII). Tooth/bone blocks were radiographed and processed for histopathological evaluation of pulp and periapical tissue response to the materials. All materials presented similar histopathological features and radiographic findings at both periods. The pulp tissue was intact. The apical and periapical regions and periodontal ligament thickness were normal. No inflammatory cells, resorption of mineralized tissue (dentin, cementum, and alveolar bone) or bacteria were observed. The lamina dura was intact and no areas of periapical bone rarefaction or internal/external root resorption were observed radiographically. It can be concluded that Rely X? Unicem and Multilink® caused no adverse tissue reactions and may be indicated for cementation of indirect restorations in deep dentin cavities without pulp exposure. Microsc. Res. Tech. 78:1098–1103, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

9.
Aim: Evaluate the composite‐to‐enamel bond after passive or active application of self‐etching primer systems on polished or pre‐etched enamel with phosphoric acid. Materials and Methods: Two self‐etch adhesives systems (SEAS) were used: Clearfil SE Bond and Easy Bond. Third human molars were divided into 8 groups (N = 10). The crown of each tooth was sectioned into halves and the mesial/distal surfaces were used. The adhesives were actively or passively applied on enamel with or without prior phosphoric‐acid etching. Resin composite cylinders were built after adhesive application. After stored in relative humidity for 24 hr/37°C the specimens were subjected to microshear test in universal testing a machine at a crosshead speed of 0.5 mm/minute. The results were analyzed with three‐way ANOVA and the Tukey test. The enamel‐etching pattern was evaluated under SEM. Results: The 2‐step SEAS system presented significantly higher adhesive bond strength means (47.37 MPa) than the 1‐step (36.87 MPa). A poor enamel‐ etching pattern was observed in active mode showing irregular and short resin tags, however there was not compromised the bond strength. Conclusion: Active or passive application produced similar values of bond strength to enamel regardless of enamel pretreatment and type of SEAS.  相似文献   

10.
The purpose of this study was to compare the effects of professional tooth whitening agents containing highly concentrated hydrogen peroxide (with and without laser activation), on the enamel surface; and the potential of four different toothpastes to remineralize any alterations. The study was performed on 50 human molars, divided in two groups: treated with Opalescence® Boost and Mirawhite® Laser Bleaching. Furthermore, each group was divided into five subgroups, a control one and 4 subgroups remineralized with: Mirasensitive® hap+, Mirawhite® Gelle?, GC Tooth Mousse? and Mirafluor® C. The samples were analysed by SEM/3D‐SEM‐micrographs, SEM/EDX‐qualitative analysis and SEM/EDX‐semiquantitative analysis. The microphotographs show that both types of bleaching cause alterations: emphasized perikymata, erosions, loss of interprizmatic substance; the laser treatment is more aggressive and loss of integrity of the enamel is determined by shearing off the enamel rods. In all samples undergoing remineralization deposits were observed, those of toothpastes based on calcium phosphate technologies seem to merge with each other and cover almost the entire surface of the enamel. Loss of integrity and minerals were detected only in the line‐scans of the sample remineralized with GC Tooth Mousse?. The semiquantitative EDX analysis of individual elements in the surface layer of the enamel indicates that during tooth‐bleaching with HP statistically significant loss of Na and Mg occurs, whereas the bleaching in combination with a laser leads to statistically significant loss of Ca and P. The results undoubtedly confirm that teeth whitening procedures lead to enamel alterations. In this context, it must be noted that laser bleaching is more aggressive for dental substances. However, these changes are reversible and can be repaired by application of remineralization toothpastes.  相似文献   

11.
This in vitro study aimed to quantify water loss at histological points in ground sections of normal enamel during air drying at room temperature (25°C) and relative humidity of 50%. From each of 10 ground sections of erupted permanent human normal enamel, three histological points (n = 30) located at 100, 300 and 500 μm from enamel surface and along a transversal following prisms paths were characterized regarding the mineral, organic and water volumes. Water loss during air drying was from 0 to 48 h. Drying occurred with both falling and constant‐drying rates, and drying stabilization times (Teq) ranged from 0.5 to 11 h with a mean 0.26 (±0.12)% weight loss. In some samples (n = 5; 15 points), Teq increased as a function of the distance from the enamel surface, and drying occurred at an apparent diffusion rate of 3.47 × 10?8 cm2 s?1. Our data provide evidence of air drying resulting in air replacing enamel's loosely bound water in prisms sheaths following a unidirectional water diffusion rate of 3.47 × 10?8 cm2 s?1 (from the original enamel surface inward), not necessarily resulting in water evaporating directly into air, with important implications for transport processes and optical and mechanical properties.  相似文献   

12.
The purpose of this study was to compare total‐etch, self‐etch, and selective etching techniques on the marginal microleakage of Class V composite restorations prepared by Er:YAG laser and bur. Class V cavities prepared on both buccal and lingual surfaces of 30 premolars by Er:YAG laser or bur and divided into six groups. The occlusal margins were in enamel, and the cervical margins were in cementum. Group‐1: bur preparation(bp)+Adper Single Bond 2 (ASB)+Filtek Z550 (FZ); Group‐2: laser preparation(lp)+(ASB)+(FZ); Group‐3: bp + Clearfil S3 Bond Plus (CSBP)+(FZ); Group‐4: lp+(CSBP) (FZ); Group‐5: bp + acid etching+(CSBP)+(FZ); Group‐6: lp + acid etching+(CSBP)+(FZ). All teeth were stored in distilled water at 37°C for 24 hr, and then thermocycled 1000 times (5–55°C). Five teeth from each group were chosen for the microleakage investigation, and two teeth for the scanning electron microscope evaluation. Teeth which were prepared for the microleakage test were immersed in .5% methylene blue dye for 24 hr. After immersion, the teeth were sectioned and observed under a stereomicroscope for dye penetration. Data were analyzed using Kruskal–Wallis and Mann–Whitney U tests (p < .05). More microleakage was observed in the cervical regions compared to the occlusal regions in Groups 3, 5, and 6, respectively (p < .05). There is no statistically significant difference in Groups 1, 2, and 4, in terms of cervical regions versus occlusal regions (p > .05). No significant differences were observed among any groups in terms of occlusal and cervical surfaces, separately (p > .05). Different etching techniques did not influence microleakage of Class V restorations prepared by Er:YAG laser and bur.  相似文献   

13.
The aim of this study was to evaluate the effect of final irrigation protocols (17% EDTA, BioPure MTAD, SmearClear, and QMiX) on microhardness and erosion of root canal dentin. Fifty roots were sectioned transversely at the cement–enamel junction and each root was sectioned horizontally into 4‐mm‐thick slices. The samples were divided into five groups (n = 10) according to the final irrigation protocol: G1: distilled water (control group); G2: 17% EDTA; G3: BioPure MTAD; G4: SmearClear; and G5: QMiX. The dentin microhardness was then measured with a load of 25 g for 10 s. Initially, the reference microhardness values were obtained for the samples without any etching. The same samples were then submitted to the final irrigation protocols. A new measure was realized and the difference between before and after the procedures was the dentin microhardness reduction. In sequence, the specimens were submitted to SEM analysis to verify the dentinal erosion. The Kruskal Wallis and Dunn tests (α = 5%) were used to compare the results. The dentin microhardness decreased for all final irrigation protocols. There was no significant difference between groups 2, 3, 4, and 5 (P > 0.05), but this groups presented significant dentin microhardness reduction than G1 (P < 0.05). In G2, occurred the highest incidence of dentinal erosion (P < 0.05). 17% EDTA, BioPure MTAD, SmearClear, and QMiX promoted significant dentin microhardness reduction. Dentinal tubules erosion was promoted by 17% EDTA. Microsc. Res. Tech., 76:1079–1083, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

14.
The aim of this study was to assess the remineralization of enamel caries lesions using the self-assembling peptide P11-4 associated with different materials. Artificial early enamel lesions were prepared on 154 primary teeth. The samples were randomly divided into eight groups: (1) control, (2) P11-4, (3) fluoridate toothpaste (FT), (4) P11-4 + FT, (5) casein phosphopeptide–amorphous calcium phosphate (CPP–ACP), (6) P11-4 + CPP–ACP, (7) fluoridate bioactive glass toothpaste (BT), and (8) P11-4 + BT. The surface enamel microhardness (EMH) and energy-dispersive X-ray spectroscopy (EDS) of the teeth were then measured at the baseline, after demineralization, and after 28 days of remineralization. The enamel surfaces were assessed by field emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM). The data were analyzed with one-way analysis of variance (ANOVA) (p < .05). EMH after demineralization was significantly lower than the baseline value (p < .001). The interventions led to an enhanced percentage of EMH recovery (%REMH), which was higher in Groups 6 and 7. There was no significant difference between Groups 3 and 4. Groups 1 and 2 had the lowest %REMH. The mean calcium/phosphate weight percentage ratio of P11-4 was significantly lower than the others (p < .001). The FESEM and AFM images revealed mineral deposition on the eroded enamel and reductions in surface roughness in Groups 5 and 7.  相似文献   

15.
BACKGROUND: Splint immobilization of the forearm is often performed in clinical practice. Previous studies investigated the effect of immobilization on bone, cartilage, muscle, and tendon, however, the acute effects on human skin microcirculation and histomorphology remains elusive. METHODS: In 12 healthy, nonsmoking individuals (aged 29.7 ± 9.1 years) a randomly selected forearm was immobilized by splinting for 72 h, whereas the other forearm served as control. In vivo Reflectance‐Mode Confocal‐Microscopy (RMCM) was performed prior (baseline value) and postimmobilization to evaluate: quantitative blood cell flow; density of functional dermal capillaries; epidermal thickness; and granular cell size. RESULTS: At 72h forearm immobilization, quantitative blood cell flow was significantly reduced (42.86 ± 3.68 cells/min) compared to the control blood flow (53.11 ± 3.68 cells/min, P < 0.05) and dermal capillaries indicates less functional density (5.73 ± 0.63 capillaries/mm2) compared to the controls (7.04 ± 0.81 capillaries/mm2, P < 0.05). Histometric assessment reveals significantly thinner epidermis following immobilization compared to the control site (40.02 ± 2.91 vs. 46.64±3.09 µm, P < 0.05). Granular cell size was significantly altered at 72 h splinting (730.1 ± 42.53 µm2) compared to the control cell size at 770.2 ± 38.21 µm2. Comparison of baseline values of both forearms indicate statistically insignificance (P > 0.05) for each parameter. CONCLUSION: At 72 h splint immobilization, for the first time, significant adaptive mechanisms were evaluated on human skin microcirculation and histomorphology using in vivo RMCM. These adaptations may be considered as an incipient atrophy of the human skin. Long‐term effects of immobilization including the regenerative potential should be evaluated in further RMCM studies. Microsc. Res. Tech. 77:99–103, 2014. © 2013 Wiley Periodicals, Inc.  相似文献   

16.
17.
Various methods have been applied to evaluate the effect of erosion and abrasion. So, the aim of this study was to check the applicability of stylus profilometry (SP), surface hardness (SH) and focus‐variation 3D microscopy (FVM) to the analysis of human enamel and dentin subjected to erosion/abrasion. The samples were randomly allocated into four groups (n = 10): G1‐enamel/erosion, G2‐enamel/erosion plus abrasion, G3‐dentin/erosion, and G4‐dentin/erosion plus abrasion. The specimens were selected by their surface hardness, and they were subjected to cycles of demineralization (Coca‐Cola®‐60 s) and remineralization (artificial saliva‐60 min). For groups G2 and G4, the remineralization procedures were followed by toothbrushing (150 strokes). The above cycle was repeated 3×/day during 5 days. The samples were assessed using SH, SP, and FVM. For each substrate, the groups were compared using an unpaired t‐test, and Pearson correlation coefficients were calculated (α = 5%). For enamel, both profilometry technique showed greater surface loss when the erosion and abrasion processes were combined (P <0.05). The correlation analysis did not reveal any relationships among SH, SP, and FVM to G2 and G4. There were significant correlation coefficients (–0.70 and –0.67) for the comparisons between the FVM and SH methods in enamel and dentin, respectively, in G1 and G3. Choosing the ideal technique for the analysis of erosion depends on the type of dental substrate. SP was not sufficiently sensitive to measure the effects on dentin of erosion or erosion/abrasion. However, SP, FVM and SH were adequate for the detection of tissue loss and demineralization in enamel. Microsc. Res. Tech., 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

18.
This study aimed to evaluate the microleakage of a universal adhesive's different application modes incorporated with Er,Cr:YSGG laser on Class V resin composite restorations. Sound human molar teeth (n = 30) were used for microleakage evaluations. Specimens with 60 standardized Class V cavities were divided into five groups according to the adhesive modes of universal adhesive, Adhese Universal (n = 12). Group 1‐etch‐and‐rinse mode with phosphoric acid; Group 2‐etch‐and‐rinse mode with Er,Cr:YSGG laser; Group 3‐selective‐etch mode with phosphoric acid; Group 4‐selective‐etch mode with Er,Cr:YSGG laser; Group 5‐self‐etch. After restorations were performed with a resin composite, Tetric N‐Ceram, the specimens were polished and subjected to thermocycling (10,000X). Following immersion in 0.5% basic fuschin for a day, the teeth were sectioned and the degree of microleakage was determined along the tooth‐resin composite interface using a light microscopy(40X). Five specimens from each group were examined by scanning electron microscopy. The Kruskal–Wallis, Siegel Castello, and Wilcoxon tests were used for statistical analyses (α = .05). At the enamel margins, significant differences were obtained among the groups (p < .05). Significantly higher microleakage scores were detected in Group 5 in comparison with Groups 1, 2, and 3. There were no significant differences between different adhesive strategies at the dentin margins (p > .05). While analyzing enamel and dentin microleakage scores, no statistically significant differences were observed in Groups 4 and 5 (p > .05). The laser application time and the adhesive modes of universal adhesives could affect the microleakage at the enamel margins. Different adhesive modes of universal adhesives combined with laser etching had no influence on the microleakage scores of dentin margins.  相似文献   

19.
Physiological oral mechanical forces may play a role on the progression of enamel carious lesions to cavitation. Thus, the aim of this study was to describe, by 3D finite element analysis, stress, and strain patterns in sound and carious enamel after a simulated occlusal load. Micro‐CT based models were created and meshed with tetrahedral elements (based on an extracted third molar), namely: a sound (ST) and a carious tooth (CT). For the CT, enamel material properties were assigned according to the micro‐CT gray values. Below the threshold corresponding to the enamel lesion (2.5 g/cm3) lower and isotropic elastic modulus was assigned (E = 18 GPa against E1 = 80 GPa, E2 = E3 = 20 GPa for sound enamel). Both models were imported into a FE solver where boundary conditions were assigned and a pressure load (500 MPa) was applied at the occlusal surface. A linear static analysis was performed, considering anisotropy in sound enamel. ST showed a more efficient transfer of maximum principal stress from enamel to the dentin layer, while for the CT, enamel layer was subjected to higher and concentrated loads. Maximum principal strain distributions were seen at the carious enamel surface, especially at the central fossa, correlating to the enamel cavity seen at the original micro‐CT model. It is possible to conclude that demineralized enamel compromises appropriate stress transfer from enamel to dentin, contributing to the odds of fracture and cavitation. Enamel fracture over a dentin lesion may happen as one of the normal pathways to caries progression and may act as a confounding factor during clinical diagnostic decisions. Microsc. Res. Tech. 78:865–872, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

20.
Microenergy dispersive X‐ray fluorescence (μ‐EDXRF) spectroscopy and scanning electron microscopy (SEM) were used to test the hypothesis that zirconia modified glass ionomer cement (GIC) could improve resistance to erosion‐abrasion to a greater extent than conventional cement. Bovine enamel (n = 40) and dentin (n = 40) samples were prepared with cavities, filled with one of the two restorative materials (GIC: glass‐ionomer cement or ZrGIC: zirconia‐modified GIC). Furthermore, the samples were treated with abrasion‐saliva (AS) or abrasion‐erosion cycles (AE). Erosive cycles (immersion in orange juice, three times/day for a duration of 1 min over a 5 day period) and/or abrasive challenges (electric toothbrush, three times/day for a duration of 1 min over a 5 day period) were performed. Positive mineral variation (MV%) on the enamel after erosion‐abrasion was observed for both materials (p < 0.05), whereas a negative MV% on the dentin was observed for both materials and treatments (p < 0.05). The SEM images showed clear enamel loss after erosion‐abrasion treatment and material degradation was greater in GIC_AE compared to those of the other groups. Toothbrush abrasion showed a synergistic effect with erosion on substance loss of bovine enamel, dentin, GIC, and ZrGIC restorations. Zirconia addition to the GIC powder improved the resistance to abrasive‐erosive processes. The ZrGIC materials may find application as a restorative material due to improved resistance as well as in temporary restorations and fissure sealants.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号