首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 43 毫秒
1.
The use of a membrane bioreactor (MBR) for removal of organic substances and nutrients from slaughterhouse plant wastewater was investigated. The chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP) concentrations of slaughterhouse wastewater were found to be approximately 571 mg O2/L, 102.5 mg/L, and 16.25 mg PO4-P/L, respectively. A submerged type membrane was used in the bioreactor. The removal efficiencies for COD, total organic carbon (TOC), TP and TN were found to be 97, 96, 65, 44% respectively. The COD value of wastewater was decreased to 16 mg/L (COD discharge standard for slaughterhouse plant wastewaters is 160 mg/L). TOC was decreased to 9 mg/L (TOC discharge standard for slaughterhouse plant wastewaters is 20 mg/L). Ammonium, and nitrate nitrogen concentrations of treated effluent were 0.100 mg NH4-N/L, and 80.521 mg NO3-N/L, respectively. Slaughterhouse wastewater was successfully treated with the MBR process.  相似文献   

2.
This paper presents the design and operational performance data of an anaerobic/aerobic hybrid side-stream Membrane Bioreactor (MBR) process for treating paper mill effluent operated over a 6 month period. The paper mill effluent stream was characterized by a chemical oxygen demand (COD) range of between 1,600 and 4,400 mg/L and an average BOD of 2,400 mg/L. Despite large fluctuations in COD feed concentration, stable process performance was achieved. The anaerobic Expanded Granular Sludge Bed (EGSB) pre-treatment step effectively lowered the organic loading by 65 to 85%, thus lowering the MBR COD feed concentration to consistently below 750 mg/L. The overall MBR COD removal was consistent at an average of 96%, regardless of the effluent COD or changes in the hydraulic retention time (HRT) and organic loading rate (OLR). Combining a high-rate anaerobic pre-treatment EGSB with a Modified Ludzack-Ettinger (MLE) MBR process configuration produced a high quality permeate. Preliminary NF and RO results indicated an overall COD removal of around 97 and 98%, respectively.  相似文献   

3.
One of the major challenges of anaerobic technology is its applicability for low strength wastewaters, such as sewage. The lab-scale design and performance of a novel Gradual Concentric Chambers (GCC) reactor treating low (165+/-24 mg COD/L) and medium strength (550 mg COD/L) domestic wastewaters were studied. Experimental data were collected to evaluate the influence of chemical oxygen demand (COD) concentrations in the influent and the hydraulic retention time (HRT) on the performance of the GCC reactor. Two reactors (R1 and R2), integrating anaerobic and aerobic processes, were studied at ambient (26 degrees C) and mesophilic (35 degrees C) temperature, respectively. The highest COD removal efficiency (94%) was obtained when treating medium strength wastewater at an organic loading rate (OLR) of 1.9 g COD/L.d (HRT = 4 h). The COD levels in the final effluent were around 36 mg/L. For the low strength domestic wastewater, a highest removal efficiency of 85% was observed, producing a final effluent with 22 mg COD/L. Changes in the nutrient concentration levels were followed for both reactors.  相似文献   

4.
The aim of this work was to study the feasibility of the denitrification process enhancement, in the Ciudad Real (Spain) WWTP, by dosing agro-food wastewaters generated nearby the city. The studied agro-food wastewaters were characterised by a high COD and low nutrients concentration. The denitrification rates with these wastewaters were lower than those obtained either with acetate or urban sewage, however the dose of agro-food wastewaters raised significantly the denitrification capacity in the WWTP because of the significant increase of easily biodegradable substrates in the wastewater. From the laboratory NUR batch test it was observed that the best agro-food wastewater to enhance the denitrification process was that coming from tomato processing, which presented an average denitrification rate of 1.9 mg NOx-N/(g VSS.h) and an average denitrification yield of 0.2 mg NOx-N/mg COD. The viability of the use of tomato processing wastewater was checked in a pilot plant optimised for urban sewage treatment with biological nutrient removal. The optimum dose, 5.9 mg COD/mg NOx-N, was applied and 99% of the nitrate was removed from the wastewater without influencing negatively either the COD or P effluent concentrations.  相似文献   

5.
This research project aimed to determine the technologically feasible and applicable wastewater treatment systems which will be constructed to solve environmental problems caused by small communities in Turkey. Pilot-scale treatment of a small community's wastewater was performed over a period of more than 2 years in order to show applicability of these systems. The present study involves removal of organic matter and suspended solids in serially operated horizontal (HFCW) and vertical (VFCW) sub-surface flow constructed wetlands. The pilot-scale wetland was constructed downstream of anaerobic reactors at the campus of TUBITAK-MRC. Anaerobically pretreated wastewater was introduced into this hybrid two-stage sub-surface flow wetland system (TSCW). Wastewater was first introduced into the horizontal sub-surface flow system and then the vertical flow system before being discharged. Recirculation of the effluent was tested in the system. When the recirculation ratio was 100%, average removal efficiencies for TSCW were 91 +/- 4% for COD, 83 +/- 10% for BOD and 96 +/- 3% for suspended solids with average effluent concentrations of 9 +/- 5 mg/L COD, 6 +/- 3 mg/L BOD and 1 mg/L for suspended solids. Comparing non-recirculation and recirculation periods, the lowest effluent concentrations were obtained with a 100% recirculation ratio. The effluent concentrations met the Turkish regulations for discharge limits of COD, BOD and TSS in each case. The study showed that a hybrid constructed wetland system with recirculation is a very effective method of obtaining very low effluent organic matter and suspended solids concentrations downstream of anaerobic pretreatment of domestic wastewaters in small communities.  相似文献   

6.
A 2.0 L volume of EGSB reactor was operated at 20 degrees C for more than 500 days with 0.3-0.4 g COD/L of sucrose base wastewater to investigate the influence of effluent-recirculation on the process performance. At the start up period, the reactor was operated in EGSB mode with 5 m/h upflow velocity by continuous effluent recirculation. The COD loading was set to 7.2-9.6 kg COD/m(3) day with HRT of 1 hour. However, in this mode, EGSB reactor exhibited insufficient COD removal efficiency, i.e., 50-60%. Therefore, UASB mode (without recirculation, 0.7 m/h upflow velocity) was used for 30 minutes in every 40 minutes cycle to increase the COD concentration in the sludge bed. As a result, an excellent process performance was shown. The COD removal efficiency increased from 65% to 91% and the reactor could maintain a good physical property of retained sludge (sludge concentration: 33.4 g VSS/L and SVI: 25 mL/g VSS). Furthermore, retained sludge possessed sufficient level of methanogenic activity at 20 degrees C.  相似文献   

7.
An integrated membrane process (IMP) comprising a membrane bioreactor (MBR) and a reverse osmosis (RO) process was developed for water reclamation. Wastewater was treated by an MBR operated at a sludge retention time (SRT) of 20 days and a hydraulic retention time (HRT) of 5.5 h. The IMP had an overall recovery efficiency of 80%. A unique feature of the IMP was the recycling of a fraction of RO concentrate back to the MBR. Experimental results revealed that a portion of the slow- and hard-to-degrade organic constituents in the recycle stream could be degraded by an acclimated biomass leading to an improved MBR treatment efficiency. Although recycling concentrated constituents could impose an inhibitory effect on the biomass and suppress their respiratory activities, results obtained suggested that operating MBR (in the novel IMP) at an F/M ratio below 0.03 g TOC/g VSS.day could yield an effluent quality comparable to that achievable without concentrate recycling. It is noted in this study that the novel IMP could achieve an average overall TOC removal efficiency of 88.940% and it consistently produced product water usable for high value reuse applications.  相似文献   

8.
The objective of this study was to characterize the mechanisms of the COD removal in the membrane bioreactor (MBR) process with powdered activated carbon (PAC) addition and to determine its optimal operation, for the removal of residual organic matters (ROM) from biologically treated swine wastewater. The MBR process with PAC showed higher removal efficiency of chemical oxygen demand (COD(Mn)) than that without PAC. When the average COD(Mn) concentration of the influent was 217 mg/L, the average COD(Mn) concentration of the permeate from the MBR with PAC was about 41.5 mg/L, indicating an approximate removal efficiency of 81%. On the other hand, the average COD(Mn) concentration of the permeate from the MBR without PAC was 172 mg/L. The PAC dosage estimated to obtain the above removal efficiency was about 0.74 g per litre of influent. Among the total residual organics removed by PAC-added MBR, 46.5% was removed by PAC adsorption, 20.8% by biodegradation, 4.4% by membrane separation, and 9.3% by enhanced microorganism activity. From these results, the MBR process with PAC was considered as a very useful treatment process for the reduction of COD(Mn) in biologically treated swine wastewater.  相似文献   

9.
The study was based on a full scale activated sludge plant (AS) compared to a parallel operated pilot membrane bioreactor (MBR) with flat sheets membranes. Both systems received their influent from an anaerobic bioreactor treating paper mill wastewater. MBR produced an effluent of much better quality than AS in terms of suspended solids, containing 1 mg/L or less in 80% of the monitoring time, while the AS effluent contained 12 mg/L. This could save the necessity of further treatment by filtration in the case of MBR. Other effluent quality parameters, such as organic matter (COD and BOD), phosphorus and ammonia nitrogen, did not indicate substantial differences between AS and MBR. Calcium carbonate scaling and formation of a bacterial layer on the membrane caused severe flux reduction. The membrane blockage because of scaling and biofouling proved to be very serious, therefore, it required proper and more complicated maintenance than the AS system. This study leads to the conclusion that in the case of paper mill wastewater, after anaerobic biotreatment, if there is no need for excellent effluent quality in terms of suspended solids, the replacement of the AS by the MBR would not be strongly justified, mainly because of maintenance cost.  相似文献   

10.
The Kaldnes biomedia K1, which is used in the patented Kaldnes Moving Bed biofilm process, has been tested along with other types of biofilm carriers for biological pretreatment of a complex chemical industry wastewater. The main objective of the test was to find a biofilm carrier that could replace the existing suspended carrier media and at the same time increase the capacity of the existing roughing filter-activated sludge plant by 20% or more. At volumetric organic loads of 7.1 kg COD/m3/d the Kaldnes Moving Bed process achieved much higher removal rates and much lower effluent concentrations than roughing filters using other carriers. The Kaldnes roughing stage achieved more than 85% removal of organic carbon and more than 90% removal of BOD5 at the tested organic load, which was equivalent to a specific biofilm surface area load of 24 g COD/m2/d. Even for the combined roughing filter-activated sludge process, the Kaldnes carriers outperformed the other carriers, with 98% removal of organic carbon and 99.6% removal of BOD5. The Kaldnes train final effluent concentrations were only 22 mg FOC/L and 7 mg BOD5/L. Based on the successful pilot testing, the full-scale plant was upgraded with Kaldnes Moving Bed roughing filters. During normal operation the upgraded plant has easily met the discharge limits of 100 mg COD/L and 50 mg SS/L. For the month of September 2002, with organic loads between 100 and 115% of the design load for the second half of the month, average effluent concentrations were as low as 9 mg FOC/L, 51 mg COD/L and 12 mg SS/L.  相似文献   

11.
The operation of an activated sludge process at a paper mill (AIPM) in Hedera, Israel, was often characterized by disturbances. As part of a research and development project, a study on new biological treatment was initiated. The study included the operation of three pilot units: a. anaerobic treatment by upflow anaerobic sludge blanket (UASB); b. aerobic treatment by two pilot units including activated sludge and membrane bioreactor (MBR), which have been operated in parallel for comparison reasons. The pilot plant working on anaerobic treatment performed COD reduction from 2,365 to 755 mg/L, expressed as average values. Based on the pilot study, a full scale anaerobic treatment system has been erected. During a period of 100 days, after achieving steady state, the MBR system provided steady operation performance, while the activated sludge produced effluent characterized by oscillatory qualities. The following results, based on average values, indicate much lower suspended solids concentrations in the MBR effluent, 2.5 mg/L, as compared to 25 mg/L in the activated sludge. The ability to develop and maintain a concentration of over 11,000 mg/L of mixed liquor volatile suspended solids in the MBR enabled an intensive bioprocess at relatively high cell residence time. This study demonstrates that the anaerobic process, followed by aerobic MBR can provide effluent of high quality which can be considered for economic reuse in the paper mill industry.  相似文献   

12.
A combination of the suspended carrier biofilm process and the activated sludge process (biofilm-activated sludge--BAS) has been shown to be very successful for the treatment of different types of pulp and paper mill effluents. The robust biofilm pre-treatment in combination with activated sludge results in a stable, compact and highly efficient process. Recent findings have shown that nutrient limited operation of the biofilm process greatly improves the sludge characteristics in the following activated sludge stage, while minimising sludge production and effluent discharge of nutrients. The nutrient limited BAS process was implemented at full scale at the S?dra Cell V?r? kraft mill and taken into operation in July 2002. After start-up and optimisation over about 5 months, the process meets all effluent discharge limits. The removal of COD is close to 70% and the removal of EDTA greater than 90%. Typical effluent concentrations of suspended solids and nutrients during stable operations have been 20-30 mg/L TSS, 0.3-0.5 mg/L phosphorus and 3-5 mg/L nitrogen. The sludge production was 0.09 kgSS/kg COD removed and the sludge volume index was 50-100 mL/g.  相似文献   

13.
In this study, four similar bench-scale submerged Anoxic/Oxic Membrane Bioreactors (MBR) were used simultaneously to investigate the effects of solids retention time (SRT) on organic and nitrogen removal in MBR for treating domestic wastewater. COD removal efficiencies in all reactors were consistently above 94% under steady state conditions. Complete conversion of NH(4+)-N to NO(3-)-N was readily achieved over a feed NH(4+)-N concentration range of 30 to 50 mg/L. It was also observed that SRT did not significantly affect the nitrification in the MBR systems investigated. The average denitrification efficiencies for the 3, 5, 10 and 20 days SRT operations were 43.9, 32.6, 47.5 and 66.5%, respectively. In general, the average effluent nitrogen concentrations, which were mainly nitrate, were about 22.2, 27.6, 21.7 and 13.9 mg/L for the 3, 5, 10 and 20 days SRT systems, respectively. The rate of membrane fouling at 3 days SRT operation was more rapid than that observed at 5 days SRT. No fouling was noted in the 10 days and 20 days SRT systems during the entire period of study.  相似文献   

14.
An integrated anaerobic-aerobic treatment system of sulphate-laden wastewater was proposed here to achieve low sludge production, low energy consumption and effective sulphide control. Before integrating the whole system, the feasibility of autotrophic denitrification utilising dissolved sulphide produced during anaerobic treatment of sulphate rich wastewater was studied here. An upflow anaerobic sludge blanket reactor was operated to treat sulphate-rich synthetic wastewater (TOC=100 mg/L and sulphate=500 mg/L) and its effluent with dissolved sulphide and external nitrate solution were fed into an anoxic biofilter. The anaerobic reactor was able to remove 77-85% of TOC at HRT of 3 h and produce 70-90 mg S/L sulphide in dissolved form for the subsequent denitrification. The performance of anoxic reactor was stable, and the anoxic reactor could remove 30 mg N/L nitrate at HRT of 2 h through autotrophic denitrification. Furthermore, sulphur balance for the anoxic filter showed that more than 90% of the removed sulphide was actually oxidised into sulphate, thereby there was no accumulation of sulphur particles in the filter bed. The net sludge productions were approximately 0.15 to 0.18 g VSS/g COD in the anaerobic reactor and 0.22 to 0.31 g VSS/g NO3- -N in the anoxic reactor. The findings in this study will be helpful in developing the integrated treatment system to achieve low-cost excess sludge minimisation.  相似文献   

15.
In order to treat wastewater to a low residual COD-concentration such as 125 mg/L, classical biological treatment is not sufficient for many types of industry. This research focused on the integrated treatment of the wastewater of the paper industry, with a membrane bioreactor (MBR) and an oxidation step. The optimal configuration was examined. Screening tests with different types of oxidation showed that ozonation after biological treatment could reduce the COD with 40% with an ozone dose of 0.4-0.8g O3/g COD. BOD/COD ratio could be increased up to 0.19. Neither combination of ozone with UV and/or hydrogen peroxide nor the process H2O2/UV or (photo-)Fenton reagents gave any improvement in COD reduction or BOD increase, unless the doses were very high. Based on these results, an integrated system MBR-ozonation was designed, with recirculation of MBR effluent over ozonation. This test showed that reduction of COD up to 125 mg/L immediately behind the MBR required a lot of ozone. A technically feasible solution was to discharge the water after an extra ozonation step, which resulted in a high total ozone dosage. The alternative, the consecutive treatment activated sludge-ozonation-activated sludge, did not give a better COD-removal with the same ozone dose as the integrated concept. The economic evaluation proves that the integrated chemical and biological treatment is expensive for the paper industry if a low discharge limit of COD has to be complied with.  相似文献   

16.
Behaviour of anionic surfactants of linear alkylbenzene sulphonates (LAS) type and non-ionic surfactants of nonylphenol polyethoxylate (NPnEO) type was studied in the conventional mechanical/biological sewage treatment plant (STP) as well as using a membrane biological reactor (MBR). LAS and NPnEO were determined using high performance liquid chromatography (HPLC) equipped with spectrofluorimetric detection. Liquid chromatography/tandem mass spectrometry (LC/MS/MS) was used for identification and quantification of stable metabolites, including nonylphenol (NP), nonylphenol monoethoxylate (NP1EO), nonylphenol diethoxylate (NP2EO) and nonylphenoxy carboxylic acids (NPnEC). The study showed that aromatic surfactants belong to the most prominent constituents in the examined municipal wastewaters with typical LAS and NPnEO concentrations of 2-10 mg/L and 0.1-0.5 mg/L, respectively. The removal of aromatic surfactants in conventional STP showed well-known features reported in the literature, including an efficient microbial transformation of the parent molecules and formation of stable metabolic products. The elimination efficiency of aromatic surfactants using the MBR unit was higher than that in the conventional STP, while the composition of recalcitrant nonylphenolic residues in the effluent seems to be ecotoxicologically more favourable due to the lower contributions of the lipophilic metabolites.  相似文献   

17.
This work focuses on the performances of two immersed membrane bioreactors used for the treatment of easily biodegradable organic matter present in food industry effluents, for the purpose of water reuse. Two reactor functioning modes (continuous and sequencing) were compared in terms of organic carbon removal and of membrane permeability. For each working mode, pollutant removal was very high, treated water quality presented a low COD concentration (< 125 mg x L(-1)), no solids in suspension and low turbidity (< 0.5 NTU). The quality of the treated water (including germ removal) enabled its reuse on site. Moreover, by developing high biomass concentrations in the reactor, excess sludge production remained very low (< 0.1 gVSS x gCOD(-1)). The performances appeared slightly better for the continuous system (lower COD concentration in the effluent, < 50 mg x L(-1), and lower sludge production). In terms of filtration, a distinct difference was observed between continuous and sequencing systems; transmembrane pressure showed a small and constant evolution rate in continuous membrane bioreactor (CMBR) although it appeared more difficult to control in sequencing membrane bioreactor (SMBR) probably due to punctually higher permeate flow rate and modified suspension properties. The rapid evolution of membrane permeability observed in SMBR was such that more frequent chemical cleaning of the membrane system was required.  相似文献   

18.
In this study, non-woven MBR was used to treat hydrolysed biosolids wasted from a biological treatment plant. The concentration of SS of hydrolysed biosolids in influent was 10,000 mg/L and the concentration of SS in effluent was less than 200 mg/L with/without discharging wasted sludge depending on different HRTs, i.e. 20, 15 and 10 d. The results indicated that the percentage of biosolids reduction in terms of SS removal efficiency in non-woven MBR was around 65, 60 and 35%, respectively, depending on different HRTs. Meanwhile, the ratio of VSS/SS was decreased from 0.78 to 0.50 and the number of smaller inorganic particle sizes increased due to extended SRT. The initial flux in the non-woven MBR was set at 0.02, 0.04 and 0.06 m3/m2/day and trans-membrane pressure (TMP) was less than 10 kPa. The permeate flux could be maintained quite stably due to lower TMP. The proposed non-woven MBR could be used to achieve the reduction of biosolids in the wastewater treatment plant.  相似文献   

19.
采用膜生物反应器-反渗透(MBR-RO)组合工艺处理生活污水的过程中,MBR出水污染指数(SDI)在2.5~3.5之间,符合RO膜元件进水要求,且添加10mg/L阻垢剂后能有效控制RO膜的结垢问题。MBR-RO组合工艺的产水水质良好,其中常规水质指标COD_(Mn)浓度0.05mg/L、NH_4~+-N浓度0.15mg/L、NO_3~--N浓度2.82mg/L、NO_2~--N浓度0.7mg/L、TP浓度0.12mg/L,TOC浓度0.51mg/L,参照国家《生活饮用水卫生标准》中主要的73项指标分析,产水达到饮用水水质标准。本研究结果表明,采用MBR-RO组合工艺生产直接饮用再生水是可行的。  相似文献   

20.
The aim of this work is to analyse the biological performances of two immersed membranes bioreactors focusing on the biomass adaptation to complex substrate degradation and the performance in term of permeate quality. Two influents were selected: a synthetic complex influent (acetate/Viandox, MBR1) and a real seafood processing wastewater (surimi product, MBR2). The MBR systems were operated for long periods without any sludge extraction except for sampling. Organic matter removal, sludge production and quality of the treated wastewater were analysed and studied. COD removal efficiencies after a period of biomass adaptation were higher than 97% and 95% for the synthetic and real wastewater respectively. In both cases, the COD of the treated wastewater was lower than 50 mg.L(-1). In spite of salt concentration in the real wastewater a biomass adaptation process occurs. In the overall operational period, a 0.058 gCOD P.gCOD T(-1) and a 0.12 gCOD P.gCOD T(-1) observed sludge yields were obtained for the MBR1 and MBR2 respectively. These values are approximately 5 to 10 times lower than those measured in conventional activated sludge process. These results showed that the presence of particular and some of non-easily degradable compounds in the influent of MBR2 didn't limit the performance of MBR in term of COD removal achieved. The results have also confirmed the excellent permeate quality for water reuse from MBRs systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号