1.
《Journal of power sources》2006,161(1):492-502
The steady-state performance and transient response for H2/air polymer electrolyte membrane (PEM) fuel cells are investigated in both single fuel cell and stack configurations under a variety of loading cycles and operating conditions. Detailed experimental parameters are controlled and measured under widely varying operating conditions. In addition to polarization curves, feed gas flow rates, temperatures, pressure drop, and relative humidity are measured. Performance of fuel cells was studied using steady-state polarization curves, transient IV response and electrochemical impedance spectroscopy (EIS) techniques. Different feed gas humidity, operating temperature, feed gas stoichiometry, air pressure, fuel cell size and gas flow patterns were found to affect both the steady state and dynamic response of the fuel cells. It was found that the humidity of cathode inlet gas had a significant effect on fuel cell performance. The experimental results showed that a decrease in the cathode humidity has a detrimental effect on fuel cell steady state and dynamic performance. Temperature was also found to have a significant effect on the fuel cell performance through its effect on membrane conductivity and water transport in the gas diffusion layer (GDL) and catalyst layer. The polarization curves of the fuel cell at different operating temperatures showed that fuel cell performance was improved with increasing temperature from 65 to 75 °C. The air stoichiometric flow rate also influenced the performance of the fuel cell directly by supplying oxygen and indirectly by influencing the humidity of the membrane and water flooding in cathode side. The fuel cell steady state and dynamic performance also improved as the operating pressure was increased from 1 to 4 atm. Based on the experimental results, both the steady state and dynamic response of the fuel cells (stack) were analyzed. These experimental data will provide a baseline for validation of fuel cell models.  相似文献   

2.
Water management is key in the optimization of proton exchange membrane fuel cell performance and durability. Humidifiers can be used to provide water vapor to cathode air, ensuring the proper operation of proton exchange membrane fuel cells. In this study, water vapor transport characteristics of hollow fiber membrane modules were investigated in shell-tube humidifiers under isothermal conditions, using two different test jig constructions: a convection jig and a diffusion jig. The mass transfer rate of water vapor was evaluated via the impact of various operating parameters, including temperature, flow rate, pressure, and relative humidity of inlet wet air, flow arrangements, and surface area of the tube side. The result was presented by the water vapor transport rate from wet air flow to dry air flow across the hollow fiber membrane. It was found that humidification performance could be improved with higher operating temperature, flow rate, and relative humidity of inlet wet air, lower pressure, larger membrane surface area, higher convection effect, and substituting co-current with counter-current flow configuration.  相似文献   

3.
The objective of the coolant induced variable temperature flow field concept is to maintain high membrane water content along the entire flow field without external humidification and without occurrence of liquid water inside the cell at higher currents. This is achieved by imposing a temperature gradient in the cathode downstream direction in such manner that the product water is just sufficient to maintain close to 100% relative humidity along the entire flow field. The concept must be feasible for stack applications and flexible to enable efficient operation under significantly different operating conditions. The concept is investigated via interactive combination of computational fluid dynamics modeling and experimental validation for two membranes, namely Nafion® 212 and Nafion® 115. Additional calculations are also carried out for a five-cell stack with Nafion® 212 membranes. The results of the computational fluid dynamics model are compared with the experimental data. Calculated and measured current density and relative humidity distributions along the cell give insight in the membrane water content and membrane water flux. With the coolant induced variable temperature flow field concept it is possible to achieve close to 100% relative humidity along the entire flow field without the requirement for external humidification, and to minimize the occurrence of liquid water inside the cell, resulting in improved performance of the cell in comparison with commonly used isothermal operation.  相似文献   

4.
Water flooding causes severe degradation of the performance and lifetime of proton exchange membrane fuel cell (PEMFC). In this study, a novel PEMFC stack with in-built moisture coil cooling was designed and the effects of moisture coil cooling on water management in the new PEMFC stack under various operating conditions were investigated. The result showed that the performance of the PEMFC stack was significantly improved due to the moisture condensation under high current density, high operating temperature, high relative humidity and high operating pressure. The output power was increases by 21.62% (525.71 W) at 1600·mA cm−2 while the increased parasitic power was no more than 35W. Moreover, degradation of the cathode catalyst layer after 100 h operation was also reduced by using moisture coil cooling. Compared with the situation without moisture condensation, the maximum decay rate of the cathode catalyst layer thickness after 100 h operation was reduced by 13.01%. Accordingly, the novel design is valuable and can be widely used in the future design of PEMFC.  相似文献   

5.
The paper describes an experimental analysis on the effect of cathode flow stoichiometry on the electrical performance of a PEMFC stack. The electrical power output of a PEMFC stack is influenced by several independent variables (factors). In order to analyse their reciprocal influence, an experimental design methodology was adopted in a previous experimental session, to determine which factors deserve particular attention. In this work, a further experimental analysis has been carried out on a very significant factor: cathode stoichiometry. Its effects on the electrical power of the PEMFC stack have been investigated. The tests were performed on a 3.5 kWel ZSW stack using the GreenLight GEN VI FC Test Station. The stack characteristics have been obtained running a predefined loading pattern. Some parameters were kept constant during the tests: anode and cathode inlet temperature, anode and cathode inlet relative humidity, anode stoichiometry and inlet temperature of the cooling water. The experimental analysis has shown that an increase in air stoichiometry causes a significant positive effect (increment) on electric power, especially at high-current density, and up to the value of 2 stoichs. These results have been connected to the cathode water flooding, and a discussion was performed concerning the influence of air stoichiometry on electrode flooding at different levels of current density operation.  相似文献   

6.
Air humidification is a crucial issue for superior performance of proton exchange membrane fuel cell (PEM fuel cell) stacks. In this work, an air humidifier is proposed for a 5 kW PEM fuel cell stack working at elevated temperatures, e.g., 90–95 °C. The high temperature coolant exiting the stack is utilized to pre-heat the air in the heat exchanging tubes of the humidifier, and the heated air is humidified with deionized water supplied by a nozzle fixed in a top cavity. Both the tubes and the nozzle are properly designed to ensure sufficient heat transfer and superior atomization. Humidification performance is evaluated under different operation conditions. The nozzle is able to inject well-atomized water with uniform droplet diameter. With the variation of inlet air flow rate, the relative humidity (RH) of the outlet air increases at the beginning, then decreases gradually due to the attenuation of dew point (DP) temperature. However, the humidification performance can be improved when higher temperature deionized water is injected or high temperature coolant is supplied. At a coolant temperature of 95 °C, the outlet air DP temperature is maintained over 80 °C with 25 °C injection water. Moreover, better humidification performance is achieved when the injection water flow rate is controlled according to the working conditions of the stack.  相似文献   

7.
Operating parameters have a huge impact on the output characteristics of a proton exchange membrane fuel cell stack. In this study, to optimize the performance of proton exchange membrane fuel cell stack, 4 sets of operating parameters, which include working temperature, cathode stoichiometric, relative humidity, and backpressure, were optimized by means of the orthogonal experimental design. The experiment was developed with the help of 4‐factor and 3‐level orthogonal table. Nine orthogonal experiments were performed, and the polarization curve, local current density distribution, and electrochemical impedance spectroscopy of each experiment were obtained. It is observed that cathode stoichiometric and working temperature have much stronger effects on the output voltage and output consistency of stack than that of relative humidity and backpressure. Using comprehensive equilibrium method, the optimized combination of each parameter was achieved as follows: the working temperature was 75°C, cathode stoichiometric was 2.5, relative humidity was 50%, and backpressure was 1 bar. The on‐site test result showed that when the cathode stoichiometric was low, and some part of the stack would be in a starvation condition and when the temperature was low, it might cause mass transfer problems.  相似文献   

8.
This report presents experimental results derived from a Proton Exchange Membrane fuel cell with a serpentine flow plate design. The investigation seeks to explore the effects of some parameters like cell operational temperature, humidification and atmospheric pressure on the general performance and efficiency of PEM fuel cell using MATLAB. A number of codes were written to generate the polarization curve for a single stack and five (5) cell stack fuel cell at various operating conditions. Detailed information of hydrogen and oxygen consumption and the effect they have on the fuel cell performance were critically analysed. The investigation concluded that the open circuit voltage generated was less than the theoretical voltage predicted in the literature. It was also noticed that an increase in current or current density reduced the voltage derived from the fuel cell stack. The experiment also clearly confirmed that when more current is being drawn from the fuel cell, more water will also be generated at the cathode section of the cell hence the need for an effective water management to improve the performance of the fuel cell. Other parameters like the stack efficiency and power density were also analysed using the experimental results obtained.  相似文献   

9.
This study determines the optimum operating parameters for a proton exchange membrane fuel cell (PEMFC) stack to obtain small variation and maximum electric power output using a robust parameter design (RPD). The operating parameters examined experimentally are operating temperatures, operating pressures, anode/cathode humidification temperatures, and reactant flow rates. First, the dynamic Taguchi method is used to obtain the maximum and stable power density against the different current densities, which are regarded as the systemic inputs considered a signal factor. The relationship between control factors and responses in the PEMFC stack is determined using a neural network. The discrete parameter levels in the dynamic Taguchi method can be divided into desired levels to acquire real optimum operating parameters. Based on these investigations, the PEMFC stack is operated at the current densities of 0.4–0.8 A/cm2. Since the voltage shift is quite small (roughly 0.73–0.83 V for each single cell), the efficiency would be higher. In the range of operation, the operating pressure, the cathode humidification temperature and the interactions between operating temperature and operating pressure significantly impact PEMFC stack performance. As the operating pressure increasing, the increments of the electric power decrease, and power stability is enhanced because the variation in responses is reduced.  相似文献   

10.
The performance of a proton exchange membrane (PEM) fuel cell is greatly affected by the operating parameters. Appropriate operating parameters are necessary for PEM fuel cells to maintain stable performance. A three-dimensional multi-phase fuel cell model (FCM) is developed to predict the effects of operating parameters (e.g. operating pressure, fuel cell temperature, relative humidity of reactant gases, and air stoichiometric ratio) on the performance of PEM fuel cells. The model presented in this paper is a typical nine-layer FCM that consists of current collectors, flow channels, gas diffusion layers, catalysts layers at the anode and the cathode as well as the membrane. A commercial Computational Fluid Dynamics (CFD) software package Fluent is used to solve this predictive model through SIMPLE algorithm and the modeling results are illustrated via polarization curves including I–V and I–P curves. The results indicate that the cell performance can be enhanced by increasing operating pressure and operating temperature. The anode humidification has more significant influences on the cell performance than the cathode humidification, and the best performance occurs at moderate air relative humidity while the hydrogen is fully humidified. In addition, the cell performance proves to be improved with the increase of air stoichiometric ratio. Based on these conclusions, several suggestions for engineering practice are also provided.  相似文献   

11.
建立气-气增湿器的数学理论模型,并基于Amesim软件建立燃料电池增湿器及空气系统仿真模型,从燃料电池系统层面分析干湿侧不同温度、压力、水含量等输入条件下的干侧出口空气的湿度变化情况,并采用水转移率(water vapor transfer rate,WVTR)对增湿器增湿性能进行评价,结果表明此模型可进行前期验证,能较好地预测汽车运行过程中增湿器的动态响应特性。  相似文献   

12.
An open-air cathode proton exchange membrane fuel cell (PEMFC) was developed. This paper presents a study of the effect of several critical operating conditions on the performance of an 8-cell stack. The studied operating conditions such as cell temperature, air flow rate and hydrogen pressure and flow rate were varied in order to identify situations that could arise when the PEMFC stack is used in low-power portable PEMFC applications. The stack uses an air fan in the edge of the cathode manifolds, combining high stoichiometric oxidant supply and stack cooling purposes. In comparison with natural convection air-breathing stacks, the air dual-function approach brings higher stack performances, at the expense of having a lower use of the total stack power output. Although improving the electrochemical reactions kinetics and decreasing the polarization effects, the increase of the stack temperature lead to membrane excessive dehydration (loss of sorbed water), increasing the ohmic resistance of the stack (lower performance).  相似文献   

13.
Variable temperature flow field concept allows maintaining close to 100% relative humidity along the entire flow field of the anode and the cathode side without external humidification using water generated during fuel cell operation for internal reactant humidification. This work deals with the experimental validation of the variable temperature flow field concept on a five-segment single cell. The experimental setup provides insight into the membrane water transport, temperature distribution on the current collectors and inside the channels, and the current density distribution along the cell. Variable temperature flow field operation with dry reactants is compared to isothermal operation with partially and fully humidified reactants. The polarization curve comparison shows that the variable temperature flow field operating efficiency is similar or better than the commonly used isothermal configuration with fully humidified reactants. The main contribution of the variable temperature flow field concept, when compared to isothermal operation, is the reduction of the mass transport losses at higher currents, since the generated water is evaporated in the stream of reactants, thereby minimizing the problem of liquid water removal from the cell.  相似文献   

14.
A concept of using the product water to internally humidify the air stream in a PEM fuel cell without external humidification is investigated by a simple, pseudo 2-D model along a single channel. This model takes into account the mass and energy balance, water and heat generation rates, heat removal, and water transport through the membrane. The model and thus the concept were confirmed experimentally using a 5-segment fuel cell. The temperature of each segment could be individually controlled, and the temperature and humidity of air could be measured between each segment. A temperature profile has been established, by applying spatially variable heat removal rates along the cathode channel, that results in relative humidity being close to 100% throughout the cell without any external humidification. The concept may be applied to a fuel cell stack resulting in simplification of the suporting system by avoiding external humidification.  相似文献   

15.
Reactant gases humidification, in most PEM fuel cell systems, is traditionally implemented to ensure both stack durability and superior performance. A cathode exhaust gases recirculation architecture allows to decrease the system volume compared to the passive humidifiers, which are classically used. Incorrect water management being responsible for irreversible degradations, a control of relative humidity at stack inlet thanks to the recirculation could be of great interest to limit their impact. In this work, investigations on performance and stability are performed during operation in recirculation mode, from the cell scale to the system scale. It was observed that high to medium recirculation ratios were able to stabilize and homogenize the cells voltages along the stack but performance was reduced due to oxygen dilution by nitrogen. Besides, large relative humidity ranges were achieved at stack inlet, which can vary from 25 to 85% and could be able to follow automotive dynamics.  相似文献   

16.
Water transport within Proton Exchange Membrane Fuel Cell (PEMFC) is investigated by systematic measurements of the water transport coefficient, defined as the net water flux across the membrane divided by the water production. It is recorded for various operating conditions (current density, gas stoichiometry, air inlet relative humidity, temperature, pressure) in a fuel cell stack fed by dry hydrogen. The measurement of the water transport coefficient shows that a significant fraction of water is collected at the anode while water is produced or injected at the cathode. Moreover, in usual operating conditions, liquid water is present at the cell outlet not only in the cathode but also in the anode. Contrary to the electrical performances, ageing has no influence on the water transport coefficient, which allows the comparison between data collected at different periods of the fuel cell lifetime. From this comparison, it was found that the hydrogen flow rate, the amount of vapor injected at cathode inlet, and the temperature are the main parameters influencing the water transport coefficient. It is shown that air and hydrogen stoichiometry present significant effects on water transport but only through these parameters.  相似文献   

17.
A parametric study of a double-cell stack of a proton exchange membrane fuel cell (PEMFC) using Grafoil™ flow-field plates is performed. A self-made membrane–electrode assembly (MEA) is used to integrate the PEMFC. Emphasis is placed on the effect of the transport parameters such as cell temperature, pressure and humidity of the reaction side, and flow-field geometry on the performance of the stack. Potential–current and power–current curves are presented. At a fixed dew point of the incoming reactants, say Tdp=30 °C, increasing the cell operating temperature past a threshold value of about 50 °C reduces the cell performance due to membrane dehydration. At a fixed cell operating temperature, a high flow back-pressure increases the cell performance through enhancing the reaction on both electrodes of the fuel cell. Moreover, the cell performance for the pressurised cathode side is better than that for the pressurised anode side due to the favourable back-diffusion of water in the membrane. Finally, empirical correlations are developed to describe the electrode process of the PEMFC stack under various operating conditions.  相似文献   

18.
《Journal of power sources》2006,158(1):316-325
Water balance in a polymer electrolyte membrane fuel cell (PEMFC) was investigated by measurements of the net drag coefficient under various conditions. The effects of water balance in the PEMFC on the cell performance were also investigated at different operating conditions. Experimental results reveal that the net drag coefficient of water through the membrane depended on current density and humidification of feed gases. It was found that the net drag coefficient (net number of water molecules transported per proton) ranged from −0.02 to 0.93, and was dependent on the operating conditions, the current load and the level of humidification. It was also found that the humidity of both anode and cathode inlet gases had a significant effect on the fuel cell performance. The resistance of the working fuel cell showed that the membrane resistance increased as the feed gas relative humidity (RH) decreased. The diffusion of water across Nafion membranes was also investigated by experimental water flux measurements. The electro-osmotic drag coefficient was evaluated from the experimental results of water balance and diffusion water flux measurements. The value of electro-osmotic drag coefficient, ranging from 1.5 to 2.6 under various operating conditions, was in agreement with literature values. The electro-osmotic drag coefficient, the net flux of water through the membrane and the effective drag as a function of operating conditions will also provide validation data for the fuel cell modeling and simulation efforts.  相似文献   

19.
A partially flooded gas diffusion layer (GDL) model is proposed and solved simultaneously with a stack flow network model to estimate the operating conditions under which water flooding could be initiated in a polymer electrolyte membrane (PEM) fuel cell stack. The models were applied to the cathode side of a stack, which is more sensitive to the inception of GDL flooding and/or flow channel two-phase flow. The model can predict the stack performance in terms of pressure, species concentrations, GDL flooding and quality distributions in the flow fields as well as the geometrical specifications of the PEM fuel cell stack. The simulation results have revealed that under certain operating conditions, the GDL is fully flooded and the quality is lower than one for parts of the stack flow fields. Effects of current density, operating pressure, and level of inlet humidity on flooding are investigated.  相似文献   

20.
Water flooding is detrimental to the performance of the proton exchange membrane fuel cell (PEMFC) and therefore it has to be addressed. To better understand how liquid water affects the fuel cell performance, direct visualisation of liquid water in the flow channels of a transparent PEMFC is performed under different operating conditions. Two high-resolution digital cameras were simultaneously used for recording and capturing the images at the anode and cathode flow channels. A new parameter extracted from the captured images, namely the wetted bend ratio, has been introduced as an indicator of the amount of liquid water present at the flow channel. This parameter, along with another previously used parameter (wetted area ratio), has been used to explain the variation in the fuel cell performance as the operating conditions of flow rates, operating pressure and relative humidity change. The results have shown that, except for hydrogen flow rate, the wetted bend ratio strongly linked to the operating condition of the fuel cell; namely: the wetted bend ratio was found to increase with decreasing air flow rate, increasing operating pressure and increasing relative humidity. Also, the status of liquid water at the anode was found to be similar to that at the cathode for most of the cases and therefore the water dynamics at the anode side can also be used to explain the relationships between the fuel cell performance and the investigated operating conditions.  相似文献   