首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Twenty-five adult patients with fully edentulous jaws, aged from 44 to 80 years were treated with seventy-one 3.5 mm diameter Astra Tech dental implants in the parasymphseal region. The length of these implants varied from 9 mm to 15 mm. Either two or three implants were inserted, subsequently exposed after a minimum period of 3 months, abutments and ball attachments placed. Full lower dentures incorporating gold alloy housings for ball-attachments were constructed. The average time that the implants were in situ was 4 years and 2 months, ranging from 1 year 3 months to 5 years and 7 months. Of the 71 implants placed, 67 achieved osseointegration-a success rate of 94%. The main complication was that of the ball-attachments becoming loose.  相似文献   

2.
This study reports the results of implant therapy involving a sinus membrane lift as well as conventional implant therapy in 24 periodontally compromised patients who were treated during the period between June 1990 and May 1995. Patients were included on the basis of being in need of at least 2 implants, 1 of which was to be placed in the maxillary sinus region, and at least 3 mm bone height was required in the sinus region. Following fenestration of the lateral sinus wall and lifting of the sinus membrane sinus implants were inserted as described for conventional implants. Annual follow-up visits included recording of plaque, probing pocket depth and bleeding on probing, and recording of the radiographic distance from the implant shoulder to the alveolar crest in mm. The Astra, Astra sinus, ITI, and ITI sinus were observed for an average of 30.8, 29.9, 29.4 and 25.3 months, respectively. Of the 80 implants inserted 1 Astra and 2 ITI had failed at 11-12 months and 1 ITI had failed at 42 months. The Kaplan-Meier estimate of the proportion of non-failed implants at 36 months were 100%, 95%, 91%, and 86% for the Astra, Astra sinus, ITI, and ITI sinus implants, respectively. Of the Astra, Astra sinus, and ITI implants, 71-82% remained free from bone-loss > or = 1.5 mm at 36 months, whereas this was the case for only 29% of the ITI sinus implants. About 80-90% of the implants remained free from plaque; 65-86% remained free from bleeding; and 44-80% remained free from pockets > or = 4 mm. These results indicate that the sinus lift technique can be used successfully in periodontally compromised patients.  相似文献   

3.
PURPOSE: This study assessed the soft tissue changes produced by the placement of hard tissue replacement (HTR) polymer chin implants for augmentation genioplasty and evaluated the dimensional stability as well as any bony changes associated with the implants. PATIENTS AND METHODS: The study group consisted of 18 patients (3 males, 15 females) with an average follow-up of 21.5 months (range, 12 to 44 months). All implants were placed through an intraoral incision and stabilized to the symphysis with a single 2.0-mm diameter titanium screw. Preoperative, postoperative, and long-term cephalometric radiographs were analyzed for changes in soft tissue thickness in the chin region, implant stability, and the presence of bone resorption. RESULTS: The net hard tissue chin augmentation achieved averaged 6.0 mm (range, 4.5 to 9 mm). Average preoperative soft tissue thickness was 12.1 mm (range, 11 to 14.5 mm) and postoperatively it was 10.6 mm (range, 10 to 13.5 mm). The average increase in soft tissue projection was 77.6% (range, 71.4% to 83.3%) of the implant thickness. There was no radiographic evidence of implant migration or bony resorption beneath the implant. CONCLUSIONS: HTR implants appear to be a predictable means of augmenting the chin, providing the desired aesthetic change, without causing resorption of underlying bone.  相似文献   

4.
A new design of single tooth implant (AstraTech, Molndal Sweden) featuring a microthreaded conical neck and TiO blast surface was evaluated clinically and radiographically after 2 years in function. Fifteen patients (age range 16 to 48) with missing maxillary anterior teeth (6 central incisors, 8 laterals, 1 bicuspid) had 4, 13 mm and 11, 15 mm implants placed under local anaesthesia and left for a period of 6 months before exposure and abutment connection/crown fabrication. All patients were seen at 4 to 6 monthly intervals for hygienist maintenance. Radiographs using Rinn holders and a long cone technique were taken at the crown insertion and after 1 year (14 subjects) and 2 years (12 subjects). All implants were successfully integrated at stage 2, and no implants have been lost. The internal conical seal design of the abutment/implant interface facilitated connection and there were no cases of abutment screw loosening. No soft tissue problems were observed, and the gingival morphology/health was well maintained. One crown was recemented after 18 months in function, and 1 crown was replaced because of a fracture to the porcelain incisal edge. At crown insertion, the mean bone level was 0.46 to 0.48 mm apical to the top of the implant and there were no statistically significant changes in the bone level over the 2 years of the study. In conclusion, the single tooth Astra implants were highly successful and bone changes within the first 2 years of function were comparable with other systems reporting high long-term success rates.  相似文献   

5.
This investigation was initiated to develop a method to provide patients with a fixed provisional prosthesis placed at the time of implant placement. Sixty-three standard 3.75-mm Nobel Biocare implants of varying lengths were placed into mandibular sites in 10 patients and followed for up to 10 years. Twenty-eight implants were immediately loaded at implant placement, providing support for fixed provisional prostheses, while 35 adjacent implants were allowed to heal submerged and stress-free. Following a 3-month healing period, the submerged implants were exposed and definitive reconstruction was accomplished. All 10 prostheses supported by 28 implants placed into immediate function at the time of implant placement were successful during the 3-month healing period. Of these 28 implants placed into immediate function, 4 ultimately failed. Of the 35 submerged implants, all are osseointegrated and in function to date. Life-table analysis demonstrates an overall 10-year survival rate of 93.4% for all implants. The 10-year life-table analysis of survival is 84.7% for immediately loaded implants and 100% for submerged implants. Statistical analysis of the submerged versus immediately loaded implants demonstrates failure rates for immediately loaded implants to be significantly higher (P = .022 by the log rank test). These data demonstrate that although mandibular implants can be successfully placed into immediate function in the short term to support fixed provisional prostheses, long-term prognosis is guarded for those implants placed into immediate function distal to the incisor region.  相似文献   

6.
The purpose of this prospective study was to investigate the clinical outcome and marginal bone resorption of three different endosseous implants placed in the anterior mandibles of 15 elderly patients. Eleven women and 4 men (ranging from 65 to 80 years, mean 71 years) had three different endosseous implants placed in the anterior mandible; one titanium plasma-sprayed cylinder implant (4-mm diameter), one titanium cylinder implant with hydroxyapatite coating (4-mm diameter), and one standard threaded titanium implant (3.75-mm diameter). Three months later, at the second-stage surgical procedure, ball abutments were connected and an overdenture was placed. At 12, 24, and 36 months, marginal bone resorption and Periotest values were recorded. None of the implants was lost in this period. An analysis of variance with repeated measurement was performed annually to test the existence of significant differences between the implants. When differences appeared, paired t tests were used to identify which differences were significant. Bonferroni multipliers were used to adjust for multiple testing. When marginal bone resorption was concerned, threaded titanium and hydroxyapatite-coated implants had significantly better scores than titanium plasma-sprayed cylinder implants. Periotest values for hydroxyapatite-coated implants were significantly better than test values for the other implants after 2 years. After 3 years significance was obtained between hydroxyapatite and screw-shaped implants only (P < .05). It was concluded that titanium plasma-sprayed cylinder implants have a less favorable prognosis than the other implants used in this study.  相似文献   

7.
Full oral rehabilitation with a high degree of success is now possible with osseointegrated implants. Osseointegration is a direct connection between living bone and the titanium implant at the level of the light microscope. Osseointegrated implants are currently used to replace single teeth, support fixed bridges and stabilize full dentures. These implants can also be placed extraorally for attachment of facial prosthesis. The surgical technique used to place implants intraorally into jaws or facial skeleton is performed in two stages using a local anesthetic and/or conscious sedation. During stage I surgery, holes are placed into the jaw using a series of gradually larger diameter burs until the desired diameter and depth of the bony preparation is achieved. The implant is then placed. The implant must remain undisturbed for 4 months for osseointegration to take place. Stage II surgery is then required to remove the mucosa over the implant and place the transmucosal abutment. After 1-2 weeks of healing, the restorative dentist can take an impression and fabricate the prosthesis. On occasion, it is necessary to augment the height and width of the atrophic jaw with autogenous or allogeneic bone grafts prior to implant placement. Bone grafts are sometimes placed on the floor of the nose or the floor of the maxillary sinus. Guided tissue regeneration is a technique used to generate bone within bony defects adjacent to implants. With long-term rates of success (5 years) of 99% for implants placed in the mandible and 95% for those placed in the maxilla, reconstruction of the jaws and cranial facial skeleton with osseointegrated implants has become the treatment of choice.  相似文献   

8.
Since August 1989, 35 consecutive patients were treated with immediate implants to replace 50 teeth requiring extractions as a result of root fractures, endodontic instability, nonrestorable carious lesions, or periodontal disease. Defects relative to the implant were morphologically grouped and were treated for bone regeneration with demineralized freeze-dried crushed cancellous bone (DFDBA), e-PTFE membrane, or both. Thread exposure initially ranged from 4 to 20 threads, while implant lengths varied from 8.5 to 18 mm. The mean implant length was 15 mm, with mean thread exposure of 11.34 threads, or 54% of the threaded length of the implant. Reentry confirmed 100% thread coverage in all but one implant in the no-wall group treated with DFDBA alone. Histologic evaluation of three cases confirmed viability of the regenerated bone. The patients were followed through April 1993, with 49 implants (98%) remaining osseointegrated and functional, supporting the predictability of immediate implant placement. The age of the patients ranged from 16 to 80 years, hence implant placement considerations relative to adolescents are also discussed.  相似文献   

9.
This retrospective study involved Japanese patients with prostheses supported by Br?nemark implants following maxillectomy. Questionnaires were sent to 75 institutions, and data on 19 patients were collected from 8 institutions. The mean age of patients at the time of implant placement was 64.2 years (range 22 to 82 years). The mean follow-up time was 27.6 months. Of the 81 implants placed, 16 were lost for an implant survival rate of 80.2%. The effects on implant survival rate of radiotherapy, chemotherapy, hyperbaric oxygen therapy, and the support system of the prosthesis were analyzed, but no significant differences were observed.  相似文献   

10.
The aim of this study was to evaluate the clinical function and long-term prognosis of overdentures retained by a small number of implants in the maxilla and mandible using one of two different attachment systems. Included in the study were all patients referred to specialty clinics in J?nk?ping and Link?ping, Sweden, during the treatment period who needed an overdenture and could be provided with a minimum number of two bilaterally-placed implants. Excluded were patients with bone-grafted jaws, irradiated cancer patients, heavy bruxers, and patients who had lost a fixed prosthesis because of implant losses. The patients were randomly assigned to receive one retentive system, either a round 2-mm-diameter bar with clips or ball attachments (Nobel Biocare). Eighteen overdentures were placed in maxillae and 32 in mandibles, supported by a total of 115 Br?nemark implants. Of the implants placed, 86.1% were continuously osseointegrated. The cumulative implant survival rates after 7 years of loading were 75.4% in the maxillae and 100% in the mandibles. There was no difference in implant survival rate between the attachment systems. Patients with implant losses were characterized by severely resorbed maxillary ridges and inferior bone quality, together with unfavorable loading circumstances such as short implants combined with long leverages. Complications and prosthetic adjustments were mostly resolved early and easily.  相似文献   

11.
This report outlines the experimental, surgical, and prosthodontic protocols for a prospective clinical trial using the Endopore dental implant to replace single maxillary teeth. Twenty patients (10 male, 10 female) ranging in age from 30 to 60 years each received one implant (mean length 10.1 mm), which, after an initial healing period of 4 months, was restored with a single crown. Records collected included radiographs, Periotest mobility measurements, supragingival Plaque Index, and an assessment of peri-implant soft tissue health using pocket probing depths, sulcular bleeding following probing, and probing attachment levels. Radiographs were exposed at predetermined intervals following crown placement (1 and 6 months, and then yearly) in a standardized procedure using a specialized filmholder that attaches to each implant after removal of the crown. At the time of this preliminary report, all of the 20 implants placed had been uncovered and were in function; 16 of the implants had been in function for 6 months or more, 14 had passed 1 year of function, and 3 had passed the 2-year function point. There have been no failures to date.  相似文献   

12.
CM Goodman  V Cohen  J Thornby  D Netscher 《Canadian Metallurgical Quarterly》1998,41(6):577-85; discussion 585-6
Because of the growing concern surrounding the integrity and life span of silicone gel breast implants and the reported variations in the diagnostic accuracy of various imaging techniques in identifying ruptured implants, the authors undertook a meta-analysis of articles in the scientific literature to examine these concerns. They were able to include reports from the literature that detailed the condition and removal of 1,099 breast implants during the past 7 years. The median life span of a silicone gel implant was estimated to be 16.4 years. Of the implants, 79.1% were intact at 10 years, falling to 48.7% by 15 years. The sensitivities and specificities of three imaging modalities used in the diagnosis of implant rupture (mammography, ultrasonography, and magnetic resonance imaging [MRI]) were also evaluated and compared statistically in an effort to discover which of the three techniques might serve as the most reliable screening tool in the diagnosis of gel implant rupture. The sensitivity of mammography for finding a ruptured implant is 28.4% with a specificity of 92.9%. Ultrasonography has a sensitivity and specificity of 59.0% and 76.8% respectively compared with MRI, which was 78.1% and 80.0% respectively. For implants in place for 10 years, one would need to image 3.3 implants by ultrasound to identify a single possible rupture. However, because of the 76.8% specificity, 8.1 implants would need to be imaged to find a confirmed intraoperative rupture. This was similar to MRI, in which 3.1 implants would need to be imaged to detect one suspected rupture, and 6.1 implants would need to be imaged to find one intraoperatively confirmed rupture. The authors do not recommend either ultrasound or MRI as a screening tool based on their meta-analysis.  相似文献   

13.
In order to achieve esthetically more satisfying results, it has been proposed to place ITI implants with their border between the rough and smooth surfaces below the level of the alveolar crest, thereby obtaining a submucosally located implant shoulder following healing. The aim of the present experimental study was to clinically and radiographically evaluate the tissue response to the placement of one-stage transmucosal implants with the border between the rough and the smooth surfaces sunk by 1 mm into a subcrestal location. 11 patients underwent comprehensive dental care including the placement of 2 implants of the ITI Dental Implant System in the same quadrant (test and control). Randomly assigned control implants were placed according to the manufacturer's instructions, i.e. the border between the rough titanium plasma-sprayed and the smooth polished surfaces precisely at the alveolar crest. At the test implant the apical border of the polished surface was placed approximately 1 mm below the alveolar crest. Probing bone levels were assessed at implant placement (baseline), 4 and 12 months later. Modified plaque and modified gingival indices were recorded at 1, 2, 3, 4 and 12 months. Clinical probing depth and "attachment" levels were measured at 4 and 12 months. All parameters were assessed at 6 sites around each implant. The mean for each implant was calculated and used for analysis. The Wilcoxon matched pairs signed rank test and the Student t-test were applied to detect differences over time and between the test and control implants. At baseline, a mean difference in probing bone level of -0.86 mm (SD 0.43 mm, p < 0.05) was found between test and control implants with the test implants being placed more deeply. Both test and control implants lost a significant amount of clinical bone height during the first 4 months (test 1.16 mm, p < 0.05; control 0.58 mm, p < 0.05). However, only the test implants significantly lost clinical bone height from 4-12 months (test 1.04 mm, p < 0.05; control 0.45 mm, p = 0.08). Overall, the test implants lost 2.26 mm and the control implants 1.02 mm of bone height during the first year of service. On the average, the test implants demonstrated a bone level of 0.38 mm lower than the controls at 12 months. Except for the modified gingival index at 4 months (mean difference 0.21, SD 0.19, p < 0.05), no clinical parameters yielded significant differences between test and control implants at any time. It is concluded that in addition to the crestal bone resorption occurring at implants placed under standard conditions, the bone adjacent to the polished surface of more deeply placed ITI implants is also lost over time. From a biological point of view, the placement of the border between the rough and the smooth surfaces into a subcrestal location should not be recommended.  相似文献   

14.
The purpose of this study was to determine which treatment of a large osseous defect adjacent to an endosseous dental implant would produce the greatest regeneration of bone and degree of osseointegration: barrier membrane therapy plus demineralized freeze-dried bone allograft (DFDBA), membrane therapy alone, or no treatment. The current study histologically assessed changes in bone within the healed peri-implant osseous defect. In a split-mouth design, 6 implants were placed in edentulous mandibular ridges of 10 mongrel dogs after preparation of 6 cylindrical mid-crestal defects, 5 mm in depth, and 9.525 mm in diameter. An implant site was then prepared in the center of each defect to a depth of 5 mm beyond the apical extent of the defect. One mandibular quadrant received three commercially pure titanium (Ti) screw implants (3.75 x 10 mm), while the contralateral side received three hydroxyapatite (HA) coated root-form implants (3.3 x 10 mm). Consequently, the coronal 5 mm of each implant was surrounded by a circumferential defect approximately 3 mm wide and 5 mm deep. The three dental implants in each quadrant received either DFDBA (canine source) and an expanded polytetrafluoroethylene membrane (ePTFE), ePTFE membrane alone, or no treatment which served as the control. Clinically, the greatest increase in ridge height and width was seen with DFDBA/ePTFE. Histologically, statistically significant differences in defect osseointegration were seen between treatment groups (P < 0.0001: DFDBA/ePTFE > ePTFE alone > control). HA-coated implants had significantly greater osseointegration within the defect than Ti implants (P < 0.0001). Average trabeculation of newly formed bone in the defect after healing was significantly greater for HA-coated implants than for titanium (P < 0.0001), while the effect on trabeculation between treatments was not significantly different (P = 0.14). Finally, there were significantly less residual allograft particles in defect areas adjacent to HA-coated implants than Ti implants (P = 0.0355). The use of HA-coated implants in large size defects with DFDBA and ePTFE membranes produced significantly more osseointegration histologically than other treatment options and more than Ti implants with the same treatment combinations. The results of this study indicate that, although the implants appeared osseointegrated clinically after 4 months of healing, histologic data suggest that selection of both the implant type and the treatment modality is important in obtaining optimum osseointegration in large size defects.  相似文献   

15.
PURPOSE: This retrospective study investigated the survival of dental implants placed in the maxilla after composite grafting of the sinus and an average of 55 months of loading. PATIENTS AND METHODS: Maxillary sinuses of 88 patients were grafted with autogenous cancellous bone combined with dense hydroxyapatite particles. After an average healing period of 3.4 months, hydroxyapatite-coated titanium endosseous implants were placed. A total of 388 implants were placed in grafted sinus floors, and 82 were placed in onlay grafted nonsinus position in the canine region. The implants were loaded with overdentures and fixed bridges 4 months (mean) after implantation, with a follow-up for a mean of 55 months. RESULTS: The cumulative implant survival was calculated according to the Kaplan-Meier method. Implant survival from the time of loading was 89% in full reconstructed cases and 90% in partially edentulous cases. The overall cumulative implant survival rate, including the loss in the surgical stage, was 82%. CONCLUSION: Implant loss in composite grafted maxillae after 70 months of follow-up was similar to loss in nongrafted maxillae.  相似文献   

16.
The specific aim of this study was to determine the response of alveolar bone after it was augmented vertically using distraction osteogenesis and subsequently loaded with implant restorations. Four dogs each had four implants placed horizontally into an edentulous mandibular quadrant and, after integration, a distraction osteogenesis device was fabricated in the laboratory. An osteotomy was made to allow the crest of the alveolar ridge to be distracted vertically. After 10 mm of vertical distraction, the device was stabilized with light cured resin. Following bone fill confirmation of the distraction gap at 10 weeks, two implants were placed into the ridges, one in distracted bone and one in nondistracted bone. After 4 months for implant integration, freestanding prostheses were fabricated. Crestal bone levels were evaluated throughout the period of function. Animals were sacrificed after 1 year of loading, for histologic evaluation of the bone. The vertical ridge augmentation averaged 8.85 +/- 1.05 mm after 10 weeks of healing following distraction, without change over 1 year of implant loading. Histologic examination showed that bone had formed between the distracted segments, creating an augmented ridge. The average thickness of the labial cortex in the distraction gap was significantly thinner than the lingual cortex in distracted bone and the lingual and labial nondistracted cortical bone. The presence of the dental implant did not significantly affect cortical bone thickness. Serial sections showed that implants remained integrated and functional without soft tissue inflammation. Dental implants placed into alveolar ridges augmented with the technique of distraction osteogenesis maintained bone and were functional for the length of this study.  相似文献   

17.
This pilot study analyzed the bone reactions to early loaded titanium plasma-sprayed implants. A total of 24 titanium plasma-sprayed implants (12 in the maxilla and 12 in the mandible) (Primary Healing Implant, Legnano) were inserted into four Macaca fascicularis monkeys with instruments specially designed to obtain a precise fit of the implant in the bone socket. A metal superstructure was cemented into 10 mandibular and 10 maxillary implants 15 days after implant insertion. The four remaining implants were used as controls. Eight months after implant placement, a block section was carried out, the defect was filled with nonresorbable hydroxyapatite, and all 24 implants were retrieved. The implants were treated to obtain thin ground sections that were examined under normal and polarized light. Histologic analysis showed that bone was observed around the implant surface in all implants. Morphometric analysis demonstrated that bone lined 67.2% (SD = 3.1%) of the maxillary implant surface, and 80.71% (SD = 4.6%) of the mandibular implant surface. No differences were found in the percentage of bone-implant contact in the control implants. In the loaded implants, however, the bone around the implants had a more compact appearance. The study demonstrated that it is possible to obtain a high percentage of bone-implant contact in early loaded titanium plasma-sprayed implants.  相似文献   

18.
Histometric evaluations as a function of time were performed with zirconium implants during the healing period in 10 Wistar rats. The implants (7 mm x 1 mm x 0.1 mm) were placed in the right tibia of the animals. Five rats were killed after 14 days and the remainder were sacrificed 30 days after implantation. The tibiae were resected, radiographed, and embedded in poly(methyl methacrylate). Three cross-sections were obtained transverse to the major axis of each tibia. Osseointegrated tissue thickness, percentage of direct bone-to-implant contact, and osseointegrated tissue volume were evaluated for each specimen. Bone formation was observed on the surface of the implanted strip that was in contact with tibia marrow. This method is proposed for the evaluation of the first stage of healing of bone in contact with different implant materials subjected to various surface treatment.  相似文献   

19.
KJ Pansegrau  KL Fridrich  D Lew  JC Keller 《Canadian Metallurgical Quarterly》1998,56(9):1067-73; discussion 1073-4
PURPOSE: This study was undertaken to compare the rate and degree of osseointegration of dental implants when placed into either autogenous corticocancellous chip or freeze-dried corticocancellous chip bone grafts. MATERIALS AND METHODS: The canine ilium was used as the model site. Thirty experimental and 15 control implants were placed in 15 dogs: autogenous versus freeze-dried corticocancellous chip bone grafts around the exposed implant surfaces. In addition to the placement of control implants, the apical portion of the grafted implants acted as their own control. The implants were harvested at 1, 2, and 3 months. The evaluation of the integration process was performed by means of light microscopy, microradiography, and histomorphometry. RESULTS: Using this model, the results indicate that at 1 month there was no statistical difference in the degree of osseointegration in the two bone grafts. At 2 months, there was a statistically greater degree of osseointegration noted in the autogenous corticocancellous chip sites than in the freeze-dried bone grafts. At 3 months, the degree of osseointegration in the two groups was 70% and 33%, respectively. At 3 months, there was virtually 100% integration with trabecular bone at the control implant sites. CONCLUSION: The results indicate that at 2 months postoperatively implants placed in an autogenous bone chip graft osseointegrate to a significantly greater degree than implants placed in a freeze-dried bone chip graft, and this difference remains at 3 months.  相似文献   

20.
DA Cottrell  LM Wolford 《Canadian Metallurgical Quarterly》1998,56(8):935-41; discussion 941-2
PURPOSE: This prospective study was designed to evaluate the long-term clinical and radiographic results of porous block hydroxyapatite (PBHA) used as a synthetic bone graft in orthognathic surgery and craniofacial augmentation. PATIENTS AND MATERIALS: A total of 245 consecutive patients were treated initially. Inclusion criteria for this study included a minimum clinical and radiographic follow-up of 5 years. In addition, all patients with known implant failures were included regardless of whether they met the study criteria. There were 111 patients that met the criteria for inclusion in this study. All patients had undergone orthognathic surgery with rigid fixation and had had inlay or onlay PBHA implants placed. Ninety-six percent of the implants were placed through an intraoral approach. Long-term postoperative radiographs were visually compared with immediate postoperative radiographs for implant position, stability, resorption, and other significant radiographic changes. The clinical examination evaluated for signs and symptoms of infection, wound dehiscence, implant exposure, implant displacement, changes in the overlying mucosa, and development of oronasal or oroantral fistulae. RESULTS: Four hundred seventy-one implants were placed: 403 in the maxilla, 44 in the mandible, and 24 in the periorbital region. There were 289 implants placed in direct communication with the maxillary sinus. The average follow-up time was 7.2 years (range, 5.0 to 10.3 years). Twenty-three implants (4.9%) were removed during the evaluation period. Lateral maxillary wall grafting had 95.7% success, with nine implants being lost in three patients. One chin implant was removed because of dissatisfaction with the aesthetics. Seven (14%) midpalatal implants used for maxillary expansion were lost, primarily because of exposure of the implant to the oral or nasal cavity at the time of surgery. When PBHA was used for alveolar cleft grafting, there was a 100% failure rate. CONCLUSION: The use of PBHA as a bone graft substitute in orthognathic surgery and for facial augmentation showed a high percentage of success and efficacy. However, adequate soft tissue coverage in the nasal floor and on the palate are paramount for success of midpalatal implants. PBHA should not be used for alveolar cleft grafting. Rigid fixation for inlay implants in the maxilla is important to provide stress shielding of the material and minimize micromovement during the initial healing phase.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号