首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 703 毫秒
1.
The cultivation of nitritation granules in sequencing batch reactor (SBR) by seeding conventional floccular activated sludge was investigated using ethanol-based synthetic wastewater. Reducing settling time offers selection pressure for aerobic granulation, and stepwise increase of influent N/C ratio can help to selectively enrich ammonia oxidizing bacteria (AOB) in aerobic granules. The spherical shaped granules were observed with the mean diameter of 1.25 mm, average settling velocity of 1.9 cm s(-1) and the sludge volume index (SVI) of 18.5-31.4 ml g(-1). After 25 days of operation, the nitrogen loading rate reached 0.0455 kg NH(4)(+)-N (kg MLSS·d)(-1), which was 4.55 times higher than that of the start-up period. The mature granules showed high nitrification ability. Ammonia removal efficiency was above 95% and nitrite accumulation ratio was in the range of 80-95%. The nitrifying bacteria were quantified by fluorescence in situ hybridization analysis, which indicated that AOB was 14.9 ± 0.5% of the total bacteria and nitrite oxidizing bacteria (NOB) was 0.89 ± 0.1% of the total bacteria. Therefore, AOB was the dominant nitrifying bacteria. It was concluded that the associated inhibition of free ammonia at the start of each cycle and free nitrous acid during the later phase of aeration may be the key factors to start up and maintain the stable nitritation.  相似文献   

2.
Nitrification can be difficult to maintain at wastewater treatment plants (WWTPs) during cold periods resulting in disrupted nitrogen removal. The aim of this study was to relate nitrification process performance to abundance and composition of the ammonia oxidizer communities in two closely located municipal WWTPs in Sweden during an eight month period covering seasonal changes and low temperature conditions. Both facilities showed lower NH(4)(+)-N removal efficiency and nitrification rates as temperature decreased. However, one of the plants had a more stable nitrification rate and higher ammonia removal efficiency throughout the entire period. The differences in performance was related to a shift in the composition of the bacterial ammonia oxidizing community from a Nitrosomonas oligotropha-dominated community to a mixed community including also Nitrosomonas ureae-like ammonia oxidizers. This was likely a response to differences in NH(4)(+)-N and organic loading.  相似文献   

3.
Nitrogen removal in piggery waste was investigated with the combined SHARON-ANAMMOX process. The piggery waste was characterized as strong nitrogenous wastewater with very low C/N ratio. For the preceding SHARON reactor, ammonium nitrogen loading and conversion rates were 0.97 kg NH4-N/m3 reactor/day and 0.73 kg NH4-N/m3 reactor/day, respectively. Alkalinity consumption for ammonium conversion was 8.5 gr bicarbonate utilized per gram ammonium nitrogen converted to NO2-N or NO3-N at steady-states operation. The successive ANAMMOX reactor was fed with the effluent from SHARON reactor. Nitrogen loading and conversion rates were 1.36 kg soluble N/m3 reactor/day and 0.72 kg soluble N/m3 reactor/day, respectively. The average NO2-N/NH4-N removal ratio by ANAMMOX reaction was 2.13. It has been observed that Candidatus "Kuenenia stuttgartiensis" were dominated in the ANAMMOX reactor based on FISH analysis.  相似文献   

4.
曝气生物滤池去除有机物及氨氮的影响因素分析   总被引:4,自引:0,他引:4  
采用以陶粒为填料的曝气生物滤池(BAF)处理生活污水,研究气水比、水力负荷、进水COD和NH3-N负荷对BAF去除COD及NH3-N的影响,分析COD及NH3-N沿滤柱的变化规律。结果表明:当试验进水COD及NH3-N质量浓度分别为300~370mg/L和20~40mg/L时,最佳气水比为4∶1~5∶1,最佳水力负荷为1.0~2.0 m3/(m2.h)。当进水COD负荷为1.69~6.47 kg/(m3.d)时,COD去除率与进水COD负荷成正相关。BAF的硝化性能与进水NH3-N和COD负荷成负相关。  相似文献   

5.
Overcapacities of anaerobic digesters at municipal WWTPs are frequently used for the treatment of organic wastes in order to increase the biogas production. However, "co-digestion" of organic wastes leads to additional nitrogen loading and to additional loads of non-biodegradable COD. The effects of (co-) digestion of organic wastes from agro-industries (slaughterhouses, dairies and leather industry) on the wastewater cycle have been evaluated in full-scale investigations at Leoben WWTP with a capacity of 90,000 pe where the methane production was increased from 700 to more than 1700 Nm3 CH4 per day. For this evaluation, mass balances for COD and nitrogen have been applied to estimate the fluxes of these substances. Application of this method is described in detail. As the additional loadings, it was found that related to methane production less nitrogen is released from the organic wastes than from the waste sludge. While the ammonia nitrogen load in the effluent from sludge digestion was about 100 g NH4-N per Nm3 of CH4 produced, in the effluent from the digestion of organic wastes only 70 g NH4-N/Nm3 CH4 were found. The decrease in the COD removal efficiency after digestion of the organic wastes started was not regarded as significant enough to be seen as a consequence of the treatment of external substrate.  相似文献   

6.
ANAMMOX工艺在生活污水深度处理中的应用研究   总被引:4,自引:0,他引:4  
随着水环境质量的恶化,高能低耗的污水深度处理技术成为当前研究热点,尤其是对于低C/N比的城市生活污水脱氮技术的研究。试验以城市生活污水的二级出水为研究对象,采用ANAMMOX下向流生物滤池,当二级出水NH3-N=15-35mg/L,CODCr=25-45mg/L,TOC=9-12mg/L,水温=25-28℃时,ANAMMOX下向流生物滤池脱氨率达80%-100%,不仅适用于处理高氨废水,也可用于城市生活污水深度处理中。试验发现pH可以用来指示ANAMMOX反应的进行,同时也可以用来指示ANAMMOX反应进程的快慢。试验中还发现,厌氧氨氧化反应速率与NO2--N含量有关,原水中NO2--N含量的增多有利于ANAMMOX工艺处理效果。  相似文献   

7.
Nitrogen removal performance and the ammonia-oxidising bacterial (AOB) community were assessed in the batch loaded 1.3 ha saturated surface vertical flow wetland at CSBP Ltd, a fertiliser and chemical manufacturer located in Kwinana, Western Australia. From September 2008 to October 2009 water quality was monitored and sediment samples collected for bacterial analyses. During the period of study the wetland received an average inflow of 1,109 m3/day with NH3-N = 40 mg/L and NO3-N = 23 mg/L. Effluent NH3-N and NO3-N were on average 31 and 25 mg/L, respectively. The overall NH3-N removal rate for the period was 1.2 g/m2/day indicating the nitrifying capacity of the wetland. The structure of the AOB community was analysed using group specific primers for the ammonia monooxygenase gene (amoA) by terminal restriction fragment length polymorphism and by clone libraries to identify key members. The majority of sequences obtained were most similar to Nitrosomonas sp. while Nitrosospira sp. was less frequent. Another two vertical flow wetlands, 0.8 ha each, were commissioned at CSBP in July 2009, since then the wetland in this study has received nitrified effluent from these two new cells.  相似文献   

8.
为探寻污水厂二级出水深度处理方法,以阜新市某污水处理公司二级出水为研究对象,进行H2O2与沸石联用去除水中COD、氨氮的研究。结果表明:在二氧化锰的催化作用下,pH值为7时,H2O2和沸石的投加量分别为1.5mL和2g,二级出水的COD从138.24mg/L降到52.76mg/L,去除率达到75.36%,NH3-N从20mg/L降到5mg/L,去除率为74.59%,出水有机物和氨氮含量达到国家相关出水标准。  相似文献   

9.
Single-stage Nitrogen removal using Anammox and Partial nitritation (SNAP) process was newly developed as an economical nitrogen removal process for ammonium rich wastewaters. The experimental studies for the evaluation of SNAP process were carried out using a novel biofilm reactor, in which hydrophilic net-type acryl fiber biomass carrier was applied. This SNAP reactor was operated under operational conditions of pH 7.5-7.7, 35 degrees C and DO 2-3 mg/L, and 60 to 80% of influent NH4-N was removed under loading rate of 0.48 kg-N/m3/d. Through the DNA analysis of the attached sludge, it was made clear that ammonium oxidizing bacteria (AOB) and anammox bacteria coexisted in the attach-immobilized sludge on the acryl fiber biomass carrier. Favorable conditions for the growth of anammox bacteria were created inside attach-immobilized nitrifying sludge. Two kinds of anammox bacteria and two kinds of AOB were detected in the SNAP sludge. Existence ratios of anammox and AOB were estimated to be 15% and 8.7%, respectively, based on the obtained clone numbers. This coexisting condition was confirmed by the FISH image of SNAP sludge and its confocal laser scanning microscope.  相似文献   

10.
三峡库区乡镇生活污水人工快渗处理中的氮素转化   总被引:1,自引:0,他引:1  
以三峡库区乡镇生活污水为水源,以三峡库区特有的滤料为介质,研究了三峡库区乡镇生活污水人工快渗处理中氮素的转化行为.结果表明:人工快渗技术用于三峡库区乡镇生活污水无害化处理极为有效,其出水总氮、氨氮及硝氮的平均质量浓度分别为10.18mg/L、6.26mg/L及3.08mg/L,TN、NH+4-N的平均去除率分别为75....  相似文献   

11.
A three-stage constructed wetland for leachate treatment was monitored on a landfill at a pilot scale. The plant had been designed to achieve at least 75% nitrogen removal. NH4-N input concentration was 240 (median) up to 290 mgl(-1) and COD concentration was 455 to 511 mgl(-1), respectively. A 14 m2 vertical flow sand filter plus a 14 m2 horizontal flow sand filter followed by a 3.3 m2 vertical flow sand filter was chosen. Acetic acid was added to the horizontal flow system for denitrification. The results showed a very stable nitrification rate within the vertical flow system of 94% (median) at NH4-N loading rates of about 10 (median) up to 17 gm(-2)d(-1). Denitrification was mainly dependent on the dosing of acetic acid and could reach a maximum of 98%. One interesting effect was the production of nitrite in the horizontal flow sand filter. This could efficiently be eliminated by the subsequent vertical flow sand filter. The chosen concept proved to be very effective for nitrogen removal. In combination with a final activated carbon filter the COD effluent concentrations could be easily and safely controlled. The design of denitrification reed beds showed a further potential for optimization.  相似文献   

12.
厌氧氨氧化作为新型生物脱氮技术其关键在于如何实现厌氧氨氧化反应的启动,现有研究多以模拟废水为研究对象,本文以猪场废水为对象的研究,利用ASBR为反应器,接种反硝化污泥培养厌氧氨氧化细菌,在NH+4-N与NO-2-N浓度均为100 mg/L的条件下,运行125 d,经历启动初期、过渡期、系统稳定运行期三个阶段,厌氧氨氧化反应器中NH+4-N的去除率达91.70%,NO-2-N去除率92.0%;NH+4-N的容积负荷为36.90 mg/L.d,NO-2-N的容积负荷为37.55 mg/(L.d),成功实现了厌氧氨氧化反应器的启动。该研究成果对厌氧氨氧化技术在工程实践的应用具有重要的指导意义。  相似文献   

13.
A simple apparatus was designed to collect ammonia gas coming out from waste stabilization ponds (WSP). The apparatus has a capture chamber and an absorption system, which were optimized under laboratory conditions prior to being used to assess ammonia volatilization rates in a pilot-scale maturation pond during summer 2005. Under laboratory conditions (water temperature = 17.1 degrees C and pH = 10.1), the average ammonia volatilization rate was 2,517 g NH3-N/ha d and the apparatus absorbed 79% of volatilized ammonia. On site, the mean ammonia volatilization rate was 15 g N/ha d, which corresponds to 3% of the total nitrogen removed (531 g N/ha d) in the maturation pond studied. A net nitrogen mass balance showed that ammonia volatilization was not the most important mechanism involved in either total nitrogen or ammonia removal. Nitrogen fractions (suspended organic nitrogen, soluble organic nitrogen, ammonia, nitrite and nitrate) from the M1 influent and effluent showed that ammonia is removed by biological (mainly algal) uptake and total nitrogen removal by sedimentation of dead algal biomass.  相似文献   

14.
This work examines ammonia volatilization associated with agricultural irrigation employing recycled water. Effluent from a secondary wastewater treatment plant was applied using a center pivot irrigation system on a 12 ha agricultural site in Palmdale, California. Irrigation water was captured in shallow pans and ammonia concentrations were quantified in four seasonal events. The average ammonia loss ranged from 15 to 35% (averaging 22%) over 2-h periods. Temporal mass losses were well-fit using a first-order model. The resulting rate constants correlated primarily with temperature and secondarily with wind speed. The observed application rates and timing were projected over an entire irrigation season using meteorological time series data from the site, which yielded volatilization estimates of 0.03 to 0.09 metric tons NH(3)-N/ha per year. These rates are consistent with average rates (0.04 to 0.08 MT NH(3)-N/ha per year) based on 10 to 20 mg NH(3)-N/L effluent concentrations and a 22% average removal. As less than 10% of the treated effluent in California is currently reused, there is potential for this source to increase, but the increase may be offset by a corresponding reduction in synthetic fertilizers usage. This point is a factor for consideration with respect to nutrient management using recycled water.  相似文献   

15.
Nitrogen removal efficiency of a pilot-scale system consisted of Modified Ludzack-Ettinger (MLE) followed by sulfur-utilizing denitrification (SUDNR) process was evaluated with a landfill leachate. For SUDNR, a down-flow mode sulfur packed bed reactor (SPBR) filled with sulfur and limestone particles was used. Although total nitrogen removal efficiency of the MLE process was about 80% at the recycle ratio of 4, effluent contained 350-450 mg/L NO(3-)-N. Up to a loading rate of 1.2 kg NO(3-)-N/m3-day, the SPBR could achieve complete removal of nitrate, and nitrate removal rate was kept to that level even at higher loading rate. When a COD/N ratio of MLE process was maintained at 2 instead of 4, more organics with molecular weight less than 500 were utilized for heterotrophic denitrification although denitrification was not complete with the lack of electron donors. Clogging in the SPBR, mainly by the accumulation of nitrogen gas in the pores, could easily be removed by introducing the effluent in an upward direction for 1 min at 1 hr intervals. The proposed treatment system could achieve nitrate free effluent with a slight increase in chemical cost. Furthermore, depending on further COD removal requirement after biological treatment, the proposed treatment system can be an economical solution.  相似文献   

16.
The start-up and activation of a nitrifying rotating biological contactor (RBC) and its performance inside a culture tank of rainbow trout were studied. First, in a lab-scale operation, the system was fed with a synthetic medium containing a high ammonia concentration (567 mg NH(4)(+)-N L(-1)) and operated at a high hydraulic retention time (HRT) (6.5 days) to minimize the wash-out of the biomass and promote the biofilm formation. Then, both inlet ammonia concentration and HRT were decreased in order to obtain operational conditions similar to those of the culture tank. During this period, the RBC was able to treat an ammonia loading rate (ALR) of 0.64 g N-NH(4)(+) L(-1) d(-1) with a removal efficiency within 70-100%. Pilot-scale experiments were carried out in culture tanks of rainbow trout. The operation of a recirculating system with the RBC unit was compared with a recirculating system without biological treatment and with a flow-through system. The use of this in-situ nitrifying unit allowed working at a recirculation ratio of 90% without negative effects on either growth or the condition factor of fishes. Up to 70% of ammonia generated was removed and a removal rate of 1.41 g NH(4)(+)-N m(-2) d(-1) was reached.  相似文献   

17.
A laboratory-scale fluidized-bed reactor with an external aeration loop was used for nitrification of high-strength ammonium wastewater (up to 500 mg NH4-N/L). The results demonstrated that the system is capable of handling ammonium removal rates of up to 2.5 kg NH4-N/m3 x d, while removal efficiencies were as high as 98% and independent of the applied ammonium loading rates. Ammonium loading rates higher than 2.5 kg NH4-N/m3 x d resulted in decreased ammonium removal efficiency. The data show that near complete ammonium removal occurred at DO concentrations as low as 0.3-0.5 mg/L. However, the nitrite-nitrogen fraction in the effluent increased from 3.5% to 23.2% when the DO dropped from 1.0 mg/L to approximately 0.4 mg/L, respectively. The high specific removal rates in this system are one order of magnitude higher than that of suspended-growth systems. This can reduce the supplementary reactor volumes required for nitrification to less than 10% of that needed in conventional activated sludge systems. These results clearly indicate the potential economic gains that could be achieved through implementation of this technology.  相似文献   

18.
An airlift reactor using zeolite particles as carrier material was used for the nitrification of effluents from the aquaculture industry. During the start-up the nitrogen concentration was kept around 100 mg NH4(+)-N/L to develop the nitrifying population. Later it was decreased down to around 3 mg NH4(+)-N/L and the dilution rate was increased up to 4.8 d(-1) in order to simulate the conditions in a an aquaculture waster treatment system. A nitrogen loading rate (NLR) of 535 mg NH(+)-N/m2 d was fully oxidized to nitrate. Higher values of NLRs caused nitrite accumulation. A second biofilm reactor was fed with a synthetic medium containing 50 mg NH4(+)-N/L which simulated the effluents from anaerobic units treating domestic wastewater. A nitrogen loading rate of 400 mg NH4(+)-N/L d was oxidized into nitrate with an efficiency of 60% at a dilution rate of 8 d(-1). Both biofilm systems allowed the development of a nitrifying population to treat the studied types of wastewaters.  相似文献   

19.
An on-site study on the operational performance of a combined eco-system of ponds and SF constructed wetland for municipal wastewater treatment and reclamation/reuse in Donging City, Shandong, China was carried out from January 2001 through October 2003. The removal efficiencies for various main parameters were: TSS 84.8 +/- 7.3%, BOD5 87.2 +/- 5.3%, CODCr 70.2 +/- 18.6%, TP 52.3 +/- 23.1%, and NH(3)-N 54.8 +/- 23.9% with effluent concentration of TSS 9.12 +/- 5.12 mg/l, BOD5 6.44 +/- 4.58 mg/l, CODCr, 42.8 +/- 6.7 mg/l, TP 0.94 +/- 0.27 mg/l and NH(3)-N 7.95 +/- 2.36 mg/l. In addition, the removal efficiencies for faecal coliforms and total bacteria were > 99.97% and > 99.998% respectively, which well meet Chinese National standards for effluent quality of municipal wastewater treatment plants. The composition of TSS was closely related to CODCr and BOD5 variations, and nitrification-denitrification is the major mechanism of nitrogen removal both in ponds and in wetlands. In addition, sedimentation also played an important role in the removal of TSS, nitrogen, phosphorus and BOD5. The removal efficiencies of various parameters, the number of species and biomass of biological community in the system increased gradually with the ecological maturation.  相似文献   

20.
Wastewater from seafood industry contains high concentrations of organic matter, nitrogen compounds, and solid matter. Constructed wetland can be used as tertiary treatment and for nutrient recycling. This research studied the performance of nitrogen and suspended solids removal efficiency of a constructed wetland treating wastewater from a seafood-processing factory located at Songkhla, southern Thailand. The existing constructed wetland has dimensions of 85 m, 352 m and 1.5 m in width, length and depth respectively, with an area of about 29,920 m2. The water depth of 0.30 m is maintained in operation with plantation of cattails (Typha augustifolia). Flow rate of influent ranged between 500-4,660 m3/d. Average hydraulic retention time in the constructed wetland was about 4.8 days. Influent and effluent from the constructed wetland were collected once a week and analyzed for pH, temperature, dissolved oxygen (DO), biochemical oxygen demand (BOD5), Suspended solid (SS), total Kjeldahl nitrogen (TKN), ammonia nitrogen (NH3-N), organic nitrogen (Org-N), nitrate (NO3-N), and nitrite (NO2-N). The average removal efficiencies of BOD5, SS, TKN, NH3-N, and Org-N were 84%, 94%, 49%, 52% and 82%, respectively. It was found that the constructed wetland acting as a tertiary treatment process provided additional removal of BOD5, SS and TKN from wastewater from the seafood industry.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏