首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 937 毫秒
1.
This paper presents the modelling and simulation of a solar water heating system using a time marching model. The results of simulations performed on an annual basis for a solar system, constructed and operated in Yugoslavia, which provides domestic hot water for a four-person family are presented. The solar water heater consists of a flat-plate solar collector, a water-storage tank, an electric heater, and a water-mixing device. The mathematical model is used to evaluate the annual variation of the solar fraction with respect to the volume of the storage tank, demand hot water temperature required, difference of this temperature and preset storage tank water temperature, and consumption profile of the domestic hot water demand. The results of this investigation may be used to design a solar collector system, and to operate already designed systems, effectively. The results for a number of designs with different storage tank volumes indicate that the systems with greater volume yield higher solar fraction values. The results additionally indicate that the solar fraction of the system increases with lower hot water demand temperature and higher differences between the mean storage water and the demand temperatures. However, when a larger storage tank volume is used, the solar fraction is less sensitive to a variation of these operation parameters.  相似文献   

2.
An indirect forced circulation solar water heating systems using a flat-plate collector is modeled for domestic hot water requirements of a single-family residential unit in Montreal, Canada. All necessary design parameters are studied and the optimum values are determined using TRNSYS simulation program. The solar fraction of the entire system is used as the optimization parameter. Design parameters of both the system and the collector were optimized that include collector area, fluid type, collector mass flow rate, storage tank volume and height, heat exchanger effectiveness, size and length of connecting pipes, absorber plate material and thickness, number and size of the riser tubes, tube spacing, and the collector’s aspect ratio. The results show that by utilizing solar energy, the designed system could provide 83-97% and 30-62% of the hot water demands in summer and winter, respectively. It is also determined that even a locally made non-selective-coated collector can supply about 54% of the annual water heating energy requirement by solar energy.  相似文献   

3.
This paper investigates thermal mixing caused by the inflow from one or two round, horizontal, buoyant jets in a water storage tank, which is part of a thermal solar installation. A set of experiments was carried out in a rectangular tank with a capacity of 0.3 m3, with one or two constant temperature inflows. As a result, two correlations based on temperature measurements have been developed. One of the correlations predicts the size of a zone of homogenous temperature, referred to herein as the mixing zone, which develops when a single hot inflow impinges on the opposite wall of the tank. The other identifies the degree of mixing resulting from the interaction between a hot inflow and a cold inflow located below the hot one. The correlations are combined with energy balances to predict the amount of hot water available in a tank with open side inlets and the corresponding temperatures of the outflows. Outdoor measurements were also performed in a solar installation, in which a commercial water storage tank with a 1.5 m3 capacity, heated by a solar collector array with a useful surface area of 42.2 m2, drives a LiBr-H2O absorption chiller. Comparison of the predicted and measured outflow temperatures under a variety of weather conditions shows a maximum difference of 3 °C.  相似文献   

4.
Through the use of the TRNSYS simulation program, the performance of a domestic solar water heating system operating with natural circulation (thermosyphon) and a daily hot water load has been analysed. The effect of tank height on the annual solar fraction of the system has been investigated for different hot water load temperatures and storage tank volumes. Optimum values (values which maximize the annual solar fraction of the system) for storage tank height and volume are calculated for operating temperatures ranging from 50 to 80°C. The response of the system to the ratio of the storage tank volume to the collector area is investigated. The dependence of the solar fraction on tank height was observed to be more notable in the case of large tank volumes and high load temperatures. The results indicate the existence of an optimum value for the tank volume at a given tank height and a high load temperature. At lower temperatures, the solar fraction rises rapidly with tank volume to a nearly constant level. An optimum value of the storage-tank-volume-to-collector-area ratio was also observed at high load temperatures.  相似文献   

5.
This paper details modeling assumptions and simulation results for an unglazed collector system supplying domestic hot water, space heating, and space cooling loads. Collectors are modeled using unglazed collector test results. Variation of savings with collector area, storage volume, heat exchanger size, and wind for the Albuquerque, NM climate are shown. Over the storage-to-collector ratio range of 40–640 l/m2 collector, annual savings varies only ±15%. Cooling is sensitive to heat exchanger size, and heating is sensitive to wind velocity. At a collector area of 23 m2, the unglazed system meets about 56% of the annual total energy demand, saving 25.9 $/m2 yr for an all-electric home. For the 23 m2 area, savings for a cold/damp (Madison) and a hot/humid (Miami) climate are 64% and 56%, respectively, of the savings in Albuquerque.  相似文献   

6.
7.
We present a three-dimensional numerical model for seasonal heat storage in the ground using vertical heat exchanger pipes. The model also accounts for convective heat flows in the ground. The storage is employed in a district solar heating system with a heat pump. The effects of storage volume, storage medium, collector area, and collector type on system performances are studied for the Helsinki (60°N) climate. Economic optimization of the storage and collector installation is also briefly discussed. For a 500-house community, a collector area of 35 m2 per house and a rock storage volume of 550 m3 per house would provide a solar fraction of 70%.  相似文献   

8.
A solar adsorption cooling system was constructed in the green building of Shanghai Institute of Building Science. The system consisted of evacuated tube solar collector arrays of area 150 m2, two adsorption chillers with nominal cooling capacity of 8.5 kW for each and a hot water storage tank of 2.5 m3 in volume. A mathematical model of the system was established. According to experimental results under typical weather condition of Shanghai, the average cooling capacity of the system was 15.3 kW during continuous operation for 8 h. The theoretical analysis of the system was verified and found to agree well with the experimental results. The performance analysis showed that solar radiant intensity had a more distinct influence on the performance of solar adsorption cooling system as compared with ambient temperature. It was observed that the cooling capacity increased with the increase of solar collector area, whereas, solar collecting efficiency varied quite contrary. With the increase of water tank volume, cooling capacity decreased, while, the solar collecting efficiency increased. The system performances can be enhanced by increasing the height-to-diameter ratio of water tank. Additionally, it was observed that solar collecting efficiency decreased with the increase of the initial temperature of water in the tank; however, cooling capacity varied on the contrary. Also can be seen is that optimum nondimensional mass flow rate is 0.7 when the specific mass flow rate exceeds 0.012 kg/m2 s.  相似文献   

9.
This paper evaluates the performance of narrow-gap vertical mantle heat exchangers with a two-pass arrangement for use in pumped-circulation solar water heaters. Both measured mantle side and tank side heat transfer correlations have been developed and implemented in a TRNSYS model of a complete solar water heater incorporating this type of heat exchanger. Predictions of the annual solar contribution for mantle-tank systems are compared to direct-coupled systems. The direct-coupled systems are found to provide slightly higher annual energy saving than mantle-tank systems for standard domestic hot water demand in Australia. However, the reduction in performance is outweighed by the benefit of freeze protection provided by incorporating a collector loop heat exchanger in the system.  相似文献   

10.
《Energy》2006,31(14):2710-2727
The main objective of the work is to demonstrate experimentally and numerically the performance of a simple solar distillation unit that is based on the multiple condensation–evaporation cycle. The pilot plant was designed, fabricated, tested and simulated at the solar energy laboratory, Mattarria Faculty of Engineering, Cairo, Egypt. The distillation chamber consists of a humidifier (evaporator) and a dehumidifier (condenser) units. The circulation of air in the two units is maintained by natural convection. The cold salt water is preheated inside the distillation unit before exchanging heat with the solar collector loop. This plant has a flat-plate collector field area of 3.1 m2, it constitutes a closed loop with its own storage tank. The research is then carried out to evaluate the unit performance of such design and to estimate the fraction factor of the solar system to the load. A numerical simulation was developed for the system being considered. A detailed annual performance of the system is presented. The annual variation of the temperatures and useful heat gain were estimated for the system components. In addition, the optimum collector area by which the system has the maximum life-cycle savings and solar fraction was obtained. The comparison between the numerical and experimental results are accepted. The multiple-effect distillation unit that is considered in the study produces 24 l/day of distilled water. The system performance can be accepted according to the previous edited results.  相似文献   

11.
A number of solar domestic hot water systems and many combined space and water heating systems have heat exchangers placed directly in the storage fluid to charge and/or discharge the tank. Operation of the heat exchanger produces a buoyancy-driven flow within the storage fluid. With a view toward controlling the flow field to increase heat transfer, a cylindrical baffle is inserted in a 350 l cylindrical storage tank. The baffle creates a 40 mm annular gap adjacent to the tank wall. A 10 m-long, 0.3 m2 copper coil heat exchanger is placed in the gap. The effects of the baffle on the transient heat transfer, delivered water temperature, heat exchanger effectiveness, and temperature distribution within the storage fluid are presented during discharge of initially thermally stratified and fully mixed storage tanks. The baffle increases the storage side convective heat transfer to the heat exchanger by 20%. This increase is attributed to higher storage fluid velocities across the heat exchanger.  相似文献   

12.
Two integrated collector storage (ICS) prototypes with about 1 m2 absorber surface each have been installed and investigated at the Institut für Solare Energiesysteme (ISE). Each consists of a water tank with an integrated collector, which is covered with a highly transparent insulating material and is very well insulated on the sides and at the back. During the test period from November 1986 to October 1987 one of them was operated at water-main pressure, and 40 liters corresponding to the hot water consumption of one person, were withdrawn every day. The solar fraction was 58% (68%) with a system efficiency of 28% (36%) (the values in parentheses also take the surplus energy in summer into account, see “Results”). The second one has been installed to study the stagnation (no water flow) performance during the same period. Detailed computer simulation programs have been developed and compared with the experimental results. Based on the u value and the transmittance-absorptance product (τα), the annual performance can be predicted with an accuracy of 4%. The influence of various parameters such as specific water withdrawal, angle of inclination, profile of water withdrawal, required hot water temperature etc. on the yearly solar fraction and yearly efficiency of the ICS can be studied. Some of the results are presented here.  相似文献   

13.
A thermosyphon solar water heating system with electric auxiliary heater was simulated using the TRNSYS simulation program. Location of the auxiliary heater, inside the storage tank or connected in series between the system and the user, was studied using the TMY meteorological data for Los Angeles, California. Simulations were performed for two different water load temperatures (60 and 80°C) and for two types of daily hot water volumes (250 and 150 l). Four types of daily hot water consumption profiles were used in the present study, namely; the widely used Rand profile, continuous, evening and morning profiles. Also, the simulation is extended to cover the effects of thermal and optical properties of the flatplate collector and the volume of the storage tank. The results show that if water is drawn on a schedule corresponding to the Rand draw profile, the system operates with higher efficiency when the auxiliary heater is located in the storage tank than when the auxiliary heater is outside the storage tank. When operated with each of the other three draw schedules, however, better performance is achieved by locating the auxiliary heater outside the tank. The increase in solar fraction depends on the load profile and volume, temperature setting, as well as the quality of the collector and the storage tank volume. When the values of the parameters FR(τα)n and FRUL are changed from 0.8 and 16 kJ/h m2°C to 0.6 and 30 kJ/h m2°C, the solar fraction decreases by approximately 40–50%.  相似文献   

14.
In China, because of the emergence of a large number of high‐rise buildings, the solar hot water heater system often uses the balcony wall‐mounted method for installation. The thermoelectric energy converter is proposed as one of the possible technologies to incorporate solar water heater to produce electricity for building application. In this paper, the conceptual development and theoretical analysis of a novel micro‐channel heat pipe evacuated tube solar collector‐incorporated thermoelectric generation are all proposed. The new system takes into account many advantages, including the high heat transfer, low convective heat loss, and low contact thermal resistance. The exergy analysis method based on the second law of thermodynamics is also introduced to evaluate the performance of this system. The results show that a novel micro‐channel heat pipe evacuated tube solar collector‐incorporated thermoelectric generation has a high thermal performance with addition of electricity production. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

15.
This paper investigates the effect of the physical location of the auxiliary source of energy in thermosyphon solar water heaters and shows that the performance of the system can be optimised with respect to the geometry of the system components. The investigation has been based on a domestic thermosyphon solar water heating system, which was simulated using the TRNSYS programme. The annual solar fraction of the system, at the weather and socioeconomic conditions of Cyprus, is, at best, approximately 77% with an in-tank auxiliary heater configuration and 86% with an external auxiliary heater. It is demonstrated that the arrangement with the external auxiliary unit has a higher collector efficiency and results in a higher annual solar fraction. In the case of in-tank auxiliary, the system performance increases with the height of the auxiliary position from the bottom of the storage tank; with the auxiliary at the bottom of the storage tank the annual solar fraction is approximately 59%, compared to 77% when the auxiliary is located at the top of the tank. The system performance also depends on the height of the collector return from the bottom of the tank.  相似文献   

16.
Domestic household thermosyphons are economically feasible and are used by over than 70% of houses in Palestine. Although domestic solar water heating for commercial applications has a good potential, only a few systems have been installed in Palestine. A systematic sizing approach for the solar system is presented in this paper and applied to a certain case study. The solar system sizing is based on the life-cycle cost LCC analysis. For the chosen case study of domestic water heating for a hotel, with hot water consumption of 2600 liters per day, the optimum collector area was found to be 37 m2, the solar fraction of heating 0.78, the LCC of system is SI 3778, with annual savings of 1338$/year and a pay back period of 3 years. With this optimized system, the cost of water heating is 1.8 $/m3comparing with 2.6 $/m3 for the conventional system.  相似文献   

17.
To performance comparative studies, two sets of water-in-glass evacuated tube solar water heater (SWH, in short) were constructed and tested. Both SWHs were identical in all aspects but had different collector tilt-angle from the horizon with the one inclined at 22° (SWH-22) and the other at 46° (SWH-46). Experimental results revealed that the collector tilt-angle of SWHs had no significant influence on the heat removal from solar tubes to the water storage tank, both systems had almost the same daily solar thermal conversion efficiency but different daily solar and heat gains, and climatic conditions had a negligible effect on the daily thermal efficiency of systems due to less heat loss of the collector to the ambient air. These findings indicated that, to maximize the annual heat gain of such solar water heaters, the collector should be inclined at a tilt-angle for maximizing its annual collection of solar radiation. Experiments also showed that, for the SWH-22, the cold water from the storage tank circulated down to the sealed end of tubes along the lower wall of tubes and then returned to the storage tank along the upper wall of solar tubes with a clear water circulation loop; whereas for the SWH-46, the situation in the morning was the same as the SWH-22, but in the afternoon, the cold water from the storage tank on the way to the sealed end was partially or fully mixed with the hot water returning to the storage tank without a clear water circulation loop, furthermore, such mixing became more intense with the increase in the inlet water temperature of solar tubes. This indicated that increasing the collector tilt-angle of SWHs had no positive effect on the thermosiphon circulation of the water inside tubes. No noticeable inactive region near the sealed end of solar tubes for both systems was observed in experiments.  相似文献   

18.
Proper estimation of potential of any renewable energy technology is essential for planning and promotion of the technology. The methods reported in literature for estimation of potential of solar water heating in a target area are aggregate in nature. A methodology for potential estimation (technical, economic and market potential) of solar water heating in a target area is proposed in this paper. This methodology links the micro-level factors and macro-level market effects affecting the diffusion or adoption of solar water heating systems. Different sectors with end uses of low temperature hot water are considered for potential estimation. Potential is estimated at each end use point by simulation using TRNSYS taking micro-level factors. The methodology is illustrated for a synthetic area in India with an area of 2 sq. km and population of 10,000. The end use sectors considered are residential, hospitals, nursing homes and hotels. The estimated technical potential and market potential are 1700 m2 and 350 m2 of collector area, respectively. The annual energy savings for the technical potential in the area is estimated as 110 kW h/capita and 0.55 million-kW h/sq. km. area, with an annual average peak saving of 1 MW. The annual savings is 650-kW h per m2 of collector area and accounts for approximately 3% of the total electricity consumption of the target area. Some of the salient features of the model are the factors considered for potential estimation; estimation of electrical usage pattern for typical day, amount of electricity savings and savings during the peak load. The framework is general and enables accurate estimation of potential of solar water heating for a city, block. Energy planners and policy makers can use this framework for tracking and promotion of diffusion of solar water heating systems.  相似文献   

19.
Y.W. Li  R.Z. Wang  J.Y. Wu  Y.X. Xu   《Applied Thermal Engineering》2007,27(17-18):2858-2868
A direct expansion solar assisted heat pump water heater (DX-SAHPWH) experimental set-up is introduced and analyzed. This DX-SAHPWH system mainly consists of 4.20 m2 direct expansion type collector/evaporator, R-22 rotary-type hermetic compressor with rated input power 0.75 kW, 150 L water tank with immersed 60 m serpentine copper coil and external balance type thermostatic expansion valve. The experimental research under typical spring climate in Shanghai showed that the COP of the DX-SAHPWH system can reach 6.61 when the average temperature of 150 L water is heated from 13.4 °C to 50.5 °C in 94 min with average ambient temperature 20.6 °C and average solar radiation intensity 955 W/m2. And the COP of the DX-SAHPWH system is 3.11 even if at a rainy night with average ambient temperature 17.1 °C. The seasonal average value of the COP and the collector efficiency was measured as 5.25 and 1.08, respectively. Through exergy analysis for each component of the DX-SAHPWH system, it can be calculated that the highest exergy loss occurs in the compressor, followed by collector/evaporator, condenser and expansion valve, respectively. Further more, some methods are suggested to improve the thermal performance of each component and the whole DX-SAHPWH system.  相似文献   

20.
The main objective of this study is to optimize the long-term performance of an existing active-indirect solar hot water plant (SHWP), which supplies hot water at 65 °C for use in a flight kitchen, using a micro genetic algorithm in conjunction with a relatively detailed model of each component in the plant and solar radiation model based on the measured data. The performance of SHWP at Changi International Airport Services (CIASs), Singapore, is studied for better payback period using the monthly average hourly diffuse and beam radiations and ambient temperature data. The data input for solar radiation model is obtained from the Singapore Meteorological Service (SMS), and these data have been compared with long-term average data of NASA (surface meteorology and solar energy or SSE). The comparison shows a good agreement between the predicted and measured hourly-averaged, horizontal global radiation.The SHWP at CIAS, which comprises 1200 m2 of evacuated-tube collectors, 50 m3 water storage tanks and a gas-fired auxiliary boiler, is first analyzed using a baseline configuration, i.e., (i) the local solar insolation input, (ii) a coolant flow rate through the headers of collector based on ASHRAE standards, (iii) a thermal load demand pattern amounting to 100 m3/day, and (iv) the augmentation of water temperature by auxiliary when the supply temperature from solar tank drops below the set point. A comparison between the baseline configuration and the measured performance of CIAS plant gives reasonably good validation of the simulation code. Optimization is further carried out for the following parameters, namely; (i) total collector area of the plant, (ii) storage volume, and (iii) three daily thermal demands. These studies are performed for both the CIAS plant and a slightly modified plant where the hot water supply to the load is adjusted constant at times when the water temperature from tank may exceed the set temperature. It is found that the latter configuration has better thermal and economic performances over the conventional design.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号