首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper evaluates the potential of grid services in France, Italy, Norway and Spain to provide an alternative income for electrolysers producing hydrogen from wind power. Grid services are simulated with each country's data for 2017 for energy prices, grid services and wind power profiles from relevant wind parks. A novel metric is presented, the value of curtailed hydrogen, which is independent from several highly uncertain parameters such as electrolyser cost or hydrogen market price. Results indicate that grid services can monetise the unused spare capacity of electrolyser plants, improving their economy in the critical deployment phase. For most countries, up-regulation yields a value of curtailed hydrogen above 6 €/kg, over 3 times higher than the EU's 2030 price target (without incentives). However, countries with large hydro power resources such as Norway yield far lower results, below 2 €/kg. The value of curtailed hydrogen also decreases with hydrogen production, corresponding to the cases of symmetric and down-regulation.  相似文献   

2.
This paper investigates the economics of a fuel cell bus fleet powered by hydrogen produced from electricity generated by a wind park in Austria. The main research question is to simultaneously identify the most economical hydrogen generation business model for the electric utility owning wind power plants and to evaluate the economics of operating a fuel cell bus fleet, with the core objective to minimize the total costs of the overall fuel supply (hydrogen production) and use (bus and operation) system. For that, three possible operation modes of the electrolyzer have been identified and the resulting hydrogen production costs calculated. Furthermore, an in-depth economic analysis of the fuel cell buses as well as the electrolyzer technology has been conducted. Results show that investment costs are the largest cost factor for both technologies. Thus, continuous hydrogen production with the smallest possible electrolyzer is the economically most favorable option. In such an operation mode (power grid), the costs of production per kg/H2 were the lowest. However, this means that the electrolyzer cannot be solely operated with electricity from the wind park, but is also dependent on the electricity mix from the grid. For fuel cell buses, the future cost development will depend very much on the respective policies and funding programs for the market uptake, as to date, the total cost of use for the fuel cell bus is more than two times higher than the diesel bus. The major final conclusion of this paper is that to make fuel cell electric busses competitive in the next years today severe policy interferences, such as subsidies for these busses as well as electrolyzers and bans for fossil energy, along with investments in the setup of a hydrogen infrastructure, are necessary.  相似文献   

3.
A techno-economic study is performed for a large scale combustion-less hydrogen production process based on Steam Methane Reforming (SMR). Two process versions relying on different renewable heat sources are compared: (1) direct solar heating from a concentrated solar power system, and (2) radiation from resistive electrical heaters (electric SMR). Both processes are developed around an integrated micro-reactor technology, incorporating in a monolithic block most sub-processes needed to perform SMR. A baseline techno-economic scenario with low-cost feedstock and electricity, priced at $4/MMBtu and $0.04/kWh respectively, results in an LCOH of $2.31/kgH2 for solar SMR and $1.59/kgH2 for electric SMR. Results further show that solar SMR is currently more attractive economically than electric SMR coupled with distributed wind power systems, but electric SMR is more favourable in the long term due to the expected future improvements in the LCOE and capacity factor of wind power systems.  相似文献   

4.
For this study, a spatially and temporally resolved optimization model was used to investigate and economically evaluate pathways for using surplus electricity to cover positive residual loads by means of different technologies to reconvert hydrogen into electricity. The associated technology pathways consist of electrolyzers, salt caverns, hydrogen pipelines, power cables, and various technologies for reconversion into electricity. The investigations were conducted based on an energy scenario for 2050 in which surplus electricity from northern Germany is available to cover the electricity grid load in the federal state of North Rhine-Westphalia (NRW).A key finding of the pathway analysis is that NRW's electricity demand can be covered entirely by renewable energy sources in this scenario, which involves CO2 savings of 44.4 million tons of CO2/a in comparison to the positive residual load being covered from a conventional power plant fleet. The pathway involving CCGT (combined cycle gas turbines) as hydrogen reconversion option was identified as being the most cost effective (total investment: € 43.1 billion, electricity generation costs of reconversion: € 176/MWh).Large-scale hydrogen storage and reconversion as well as the use of the hydrogen infrastructure built for this purpose can make a meaningful contribution to the expansion of the electricity grid. However, for reasons of efficiency, substituting the electricity grid expansion entirely with hydrogen reconversion systems does not make sense from an economic standpoint. Furthermore, the hydrogen reconversion pathways evaluated, including large-scale storage, significantly contribute to the security of the energy supply and to secured power generation capacities.  相似文献   

5.
This paper examines the current state of the art of hydrogen refuelling stations-based production and storage systems for fuel cell hybrid electric vehicles (FCHEV). Nowadays, the emissions are increasing rapidly due to the usage of fossil fuels and the demand for hydrogen refuelling stations (HRS) is emerging to replace the conventional vehicles with FCHEVs. Hence, the availability of HRS and its economic aspects are discussed. In addition, a comprehensive study is presented on the energy storage systems such as batteries, supercapacitors and fuel cells which play a major role in the FCHEVs. An energy management system (EMS) is essential to meet the load requirement with effective utilisation of power sources with various optimizing techniques. A detailed comparative analysis is presented on the merits of Reinforcement learning (RL) for the FCHEVs. The significant challenges are discussed in depth with potential solutions for future work.  相似文献   

6.
A numerical method was developed for optimising solar–hydrogen energy system to supply renewable energy for typical household connected with the grid. The considered case study involved household located in Diyala Governorate, Iraq. The solar–hydrogen energy system was designed to meet the desired electrical load and increase the renewable energy fraction using optimum fuel cell capacity. The simulation process was conducted by MATLAB based on the experimental data for electrical load, solar radiation and ambient temperature at a 1-min time-step resolution. Results demonstrated that the optimum fuel cell capacity was approximately 2.25 kW at 1.8 kW photovoltaic power system based on the average of the daily energy consumption of 6.8 kWh. The yearly renewable energy fraction increased from 31.82% to 95.82% due to the integration of the photovoltaic system with a 2.25 kW fuel cell used as a robust energy storage unit. In addition, the energy supply, which is the economic aspect for the optimum system, levelised electricity cost by approximately $0.195/kWh. The obtained results showed that the proposed numerical analysis methodology offers a distinctive property that can be used effectively to optimise hybrid renewable energy systems.  相似文献   

7.
In this paper, the performance of a solar gas turbine (SGT) system integrated to a high temperature electrolyzer (HTE) to generate hybrid electrical power and hydrogen fuel is analyzed. The idea behind this design is to mitigate the losses in the electrical power transmission and use the enthalpy of exhaust gases released from the gas turbine (GT) to make steam for the HTE. In this context, a GT system is coupled with a solar tower including heliostat solar field and central receiver to generate electrical power. To make steam for the HTE, a flameless boiler is integrated to the SGT system applying the SGT extremely high temperature exhaust gases as the oxidizer. The results indicate that by increasing the solar receiver outlet temperature from 800 K to 1300 K, the solar share increases from 22.1% to 42.38% and the overall fuel consumption of the plant reduces from 7 kg/s to 2.7 kg/s. Furthermore, flameless mode is achievable in the boiler while the turbine inlet temperature (TIT) is maintained at the temperatures higher than 1314 K. Using constant amounts of the SGT electrical power, the HTE voltage decreases by enhancing the HTE steam temperature which result in the augmentation of the overall hydrogen production. To increase the HTE steam temperature from 950 K to 1350 K, the rate of fuel consumption in the flameless boiler increases from 0.1 m/s to 0.8 m/s; however, since the HTE hydrogen production increases from 4.24 mol/s to 16 mol/s it can be interpreted that the higher steam temperatures would be affordable. The presented hybrid system in this paper can be employed to perform more thermochemical analyses to achieve insightful understanding of the hybrid electrical power-hydrogen production systems.  相似文献   

8.
In this study, different hydrogen refueling station (HRS) architectures are analyzed energetically as well as economically for 2015 and 2050. For the energetic evaluation, the model published in Bauer et al. [1] is used and norm-fitting fuelings according to SAE J2601 [2] are applied. This model is extended to include an economic evaluation. The compressor (gaseous hydrogen) resp. pump (liquid hydrogen) throughput and maximum pressures and volumes of the cascaded high-pressure storage system vessels are dimensioned in a way to minimize lifecycle costs, including depreciation, capital commitment and electricity costs. Various station capacity sizes are derived and energy consumption is calculated for different ambient temperatures and different station utilizations. Investment costs and costs per fueling mass are calculated based on different station utilizations and an ambient temperature of +12 °C. In case of gaseous trucked-in hydrogen, a comparison between 5 MPa and 20 MPa low-pressure storage is conducted. For all station configurations and sizes, a medium-voltage grid connection is applied if the power load exceeds a certain limit. For stations with on-site production, the electric power load of the hydrogen production device (electrolyzer or gas reformer) is taken into account in terms of power load. Costs and energy consumption attributed to the production device are not considered in this study due to comparability to other station concepts. Therefore, grid connection costs are allocated to the fueling station part excluding the production device. The operational strategy of the production device is also considered as energy consumption of the subsequent compressor or pump and the required low-pressure storage are affected by it. All station concepts, liquid truck-supplied hydrogen as well as stations with gaseous truck-supplied or on-site produced hydrogen show a considerable cost reduction potential. Long-term specific hydrogen costs of large stations (6 dispensers) are 0.63 €/kg – 0.76 €/kg (dependent on configuration) for stations with gaseous stored hydrogen and 0.18 €/kg for stations with liquid stored hydrogen. The study focuses only on the refueling station and does not allow a statement about the overall cost-effectiveness of different pathways.  相似文献   

9.
Hydrogen produced from renewable electricity through Power-to-Hydrogen can facilitate the integration of high levels of variable renewable electricity into the energy system. An electrolyser is a device that splits water into hydrogen and oxygen using electricity. When electricity is produced from renewable energy sources, electrolytic hydrogen can be considered to be green. At the same time, electrolysers can help integrate renewable electricity into power systems, as their electricity consumption can be adjusted to follow wind and solar power generation. Green hydrogen then also becomes a carrier for renewable electricity. Key green hydrogen production technologies, mostly PEM and alkaline electrolysers, are still further maturing, both in technical (efficiency), economical (CAPEX) and durability (lifetime) performance. Nonetheless, we will show in this contribution how fossil parity for green hydrogen, i.e. a Total Cost of Ownership (TCO) similar to grey H2 coming from todays CO2 intensive SMR processes, can already be achieved today. Moreover, this can be realised at a scale which corresponds to the basic units of renewable electricity generation, i.e. a few MW.  相似文献   

10.
In this paper, the robust capability of HOMER and Criteria-COPRAS is deployed to explore the prospect of selecting a renewable energy system. The energy system consisting of wind turbines, solar photovoltaic (PV), fuel cell (FC), electrolyzer, hydrogen storage, and battery energy storage is intended to power a residential load in Lagos Nigeria. Based on the economic metric, the results show that the optimal system is a PV-Battery whose total net present cost (TNPC) and initial investment cost are $9060 and $3,818, respectively. However, if the energy systems are ranked based on multiple criteria (economic, technical and environmental aspects), the most preferred of the feasible energy systems is a hybrid PV-FC-wind-battery (TNPC-$10,324, initial cost: $7670). The study results indicate that, for viability in the adoption of hydrogen energy storage as part of the hybrid energy system, the selection metric should be based on more than one criterion.  相似文献   

11.
A novel project solution for large-scale hydrogen application is proposed utilizing surplus wind and solar generated electricity for hydrogen generation and NG pipeline transportation for hydrogen-natural gas mixtures (called HCNG). This application can practically solve urgent issues of large-scale surplus wind and solar generated electricity and increasing NG demand in China. Economic evaluation is performed in terms of electricity and equipment capacity estimation, cost estimation, sensitivity analysis, profitability analysis and parametric study. Equipment expenses are dominant in the construction period, especially those of the electrolysers. Electricity cost and transportation cost are the main annual operating costs and greatly influence the HCNG and pure hydrogen costs. The project proves to be feasible through the profitability analysis. The main influence items are tested individually to guarantee project profitability within 22 years. The project can reduce 388.40 M Nm3 CO2 emissions and increase 2998.52 M$ incomes for solar and wind power stations.  相似文献   

12.
The investment costs of water electrolysis represent one key challenge for the realisation of renewable hydrogen-based energy systems. This work presents a technology cost assessment and outlook towards 2030 for alkaline electrolysers (AEL) and PEM electrolysers (PEMEL) in the MW to GW range taking into consideration the effects of plant size and expected technology developments. Critical selected data was fitted to a modified power law to describe the cost of an electrolyser plant based on the overall capacity and a learning/technology development rate to derive cost estimations for different PEMEL and AEL plant capacities towards 2030. The analysis predicts that the CAPEX gap between AEL and PEMEL technologies will decrease significantly towards 2030 with plant size until 1–10 MW range. Beyond this, only marginal cost reductions can be expected with CAPEX values approaching 320–400 $/kW for large scale (greater than 100 MW) plants by 2030 with subsequent cost reductions possible. Learning rates for electrolysers were estimated at 25–30% for both AEL and PEMEL, which are significantly higher than the learning rates reported in previous literature.  相似文献   

13.
The need for a rapid transformation to low-carbon economies has rekindled hydrogen as a promising energy carrier. Yet, the full range of environmental consequences of large-scale hydrogen production remains unclear. Here, prospective life cycle analysis is used to compare different options to produce 500 Mt/yr of hydrogen, including scenarios that consider likely changes to future supply chains. The resulting environmental and human health impacts of such production levels are further put into context with the Planetary Boundaries framework, known human health burdens, the impacts of the world economy, and the externality-priced production costs that embody the environmental impact. The results indicate that climate change impacts of projected production levels are 3.3–5.4 times higher than the allocated planetary boundary, with only green hydrogen from wind energy staying below the boundary. Human health impacts and other environmental impacts are less severe in comparison but metal depletion and ecotoxicity impacts of green hydrogen deserve further attention. Priced-in environmental damages increase the cost most strongly for blue hydrogen (from ~2 to ~5 USD/kg hydrogen), while such true costs drop most strongly for green hydrogen from solar photovoltaic (from ~7 to ~3 USD/kg hydrogen) when applying prospective life cycle analysis. This perspective helps to evaluate potentially unintended consequences and contributes to the debate about blue and green hydrogen.  相似文献   

14.
The paper discusses the suitability of bedded salt deposits for underground hydrogen storage facilities. The presented research is an example of multi-criteria decision analysis coupled with spatial data analysis undertaken using GIS (Geographic Information System). The aim of this study is to develop a methodology for selecting the best locations for hydrogen storage in salt caverns. In the analysis, we take into account the results of previous studies of the storage capacity of rock salt deposits. The presented methodology allows the creation of rock salt deposit suitability maps for underground hydrogen storage. The results show that the applied method significantly influences the resulting map image, helping to identify optimal locations for hydrogen storage facilities. The presented approach may be of value to governmental institutions considering underground hydrogen storage, geological services, power plants producing electricity from renewable energy sources, and chemical and petrochemical plants.  相似文献   

15.
Considering the high calorific value and low-carbon characteristics of hydrogen energy, it will play an important role in replacing fossil energy sources. The production of hydrogen from renewable energy sources for electricity generation and electrolysis of water is an important process to obtain green hydrogen compared with classic low-carbon hydrogen production methods. However, the challenges in this process include the high cost of liquefied hydrogen and the difficulty of storing hydrogen on a large scale. In this paper, we propose a new route for hydrogen storage in metals, namely, electricity generation from renewable energy sources, electrolysis to obtain metals, and subsequent hydrogen production from metals and water. Metal monomers facilitate large-scale and long-term storage and transportation, and metals can be used as large-scale hydrogen storage carriers in the future. In this technical route, the reaction between metal and water for hydrogen production is an important link. In this paper, we systematically summarize the research progress, development trend, and challenges in the field of metal to hydrogen production. This study aim to aid in the development of this field.  相似文献   

16.
The present work examines the combination of solar energy systems with Fuel cell. Indeed, fuel cells are green storage systems without any pollution effects. They are supplied by oxygen and hydrogen to produce electricity. That is why it is inescapable to find a source of hydrogen in order to use fuel cell. Several techniques can be adopted to produce hydrogen depending on the availability and the cost of the sources. One of the most utilized techniques is electrolysers. They allow to obtain hydrogen from water by several technologies among them proton exchange membrane (PEM) which is considered in this work. On the other hand, electrolysers need electrical power to operate. A green-green energy system can be constructed by using a renewable energy source to supply fuel cell trough electrolysers. A comparison between two solar systems (Photovoltaic and Parabolic Trough) coupled to fuel cell is performed. A case study on the Lebanese city of Tripoli is carried out. The study shows the performance of each of both combined systems for different parameters and proposes recommendations depending on the considered configuration.  相似文献   

17.
Artificial Neural Networks (ANN) have been widely used by scientists in a variety of energy modes (biomass, wind, solar, geothermal, and hydroelectric). This review highlights the assistance of ANN for researchers in the quest for discovering more advanced materials/processes for efficient hydrogen production (HP). The review is divided into two parts in this context. The first section briefly mentions, in terms of technologies, economy, energy consumption, and costs symmetrically outlined the advantages and disadvantages of various HP routes such as fossil fuel/biomass conversion, water electrolysis, microbial fermentation, and photocatalysis. Subsequently, ANN and ANN hybrid studies implemented in HP research were evaluated. Finally, statistics of hybrid studies with ANN are given, and future research proposals and hot research topics are briefly discussed. This research, which touches upon the types of ANNs applied to HP methods and their comparison with other modeling techniques, has an essential place in its field.  相似文献   

18.
The aim of this research is to analyze the techno‐economic performance of hybrid renewable energy system (HRES) using batteries, pumped hydro‐based, and hydrogen‐based storage units at Sharurah, Saudi Arabia. The simulations and optimization process are carried out for nine HRES scenarios to determine the optimum sizes of components for each scenario. The optimal sizing of components for each HRES scenario is determined based on the net present cost (NPC) optimization criterion. All of the nine optimized HRES scenarios are then evaluated based on NPC, levelized cost of energy, payback period, CO2 emissions, excess electricity, and renewable energy fraction. The simulation results show that the photovoltaic (PV)‐diesel‐battery scenario is economically the most viable system with the NPC of US$2.70 million and levelized cost of energy of US$0.178/kWh. Conversely, PV‐diesel‐fuel cell system is proved to be economically the least feasible system. Moreover, the wind‐diesel‐fuel cell is the most economical scenario in the hydrogen‐based storage category. PV‐wind‐diesel‐pumped hydro scenario has the highest renewable energy fraction of 89.8%. PV‐wind‐diesel‐pumped hydro scenario is the most environment‐friendly system, with an 89% reduction in CO2 emissions compared with the base‐case diesel only scenario. Overall, the systems with battery and pumped hydro storage options have shown better techno‐economic performance compared with the systems with hydrogen‐based storage.  相似文献   

19.
With a relatively high energy density, hydrogen is attracting increasing attention in research, commercial and political spheres, specifically as a fuel for residential heating, which is proving to be a difficult sector to decarbonise in some circumstances. Hydrogen production is dependent on the power system so any scale use of hydrogen for residential heating will impact various aspects of the power system, including electricity prices and renewable generation curtailment (i.e. wind, solar). Using a linearised optimal power flow model and the power infrastructure on the island of Ireland this paper examines least cost optimal investment in electrolysers in the presence of Ireland's 70% renewable electricity target by 2030. The introduction of electrolysers in the power system leads to an increase in emissions from power generation, which is inconsistent with some definitions of green hydrogen. Electricity prices are marginally higher with electrolysers whereas the optimal location of electrolysers is driven by a combination of residential heating demand and potential surplus power supplies at electricity nodes.  相似文献   

20.
Mine sites are an ideal candidate to be decarbonised through the installation of variable renewables and storage. However, the operation of mine sites is dependent on many factors, including mineral price, which can vary significantly, leading to periods of inactivity. Therefore, for sites that have invested in renewable generation and storage, there exists a potential of stranded assets, which negatively impact their business case, potentially reducing investment in such equipment and, therefore, decarbonisation potential. The current study therefore has investigated the potential of using variable renewable energy coupled with thermal energy storage and biodiesel to supply heat to a mine site. With the base case established, the economic impact of lower or no mine operations on the net present value were evaluated. To reduce the impact of mine turndown, the potential of installing a hydrogen production facility in an effort to utilise the stranded assets was also undertaken. Preliminary results show the base case to be very economical with a net present cost of $151.4 M after 30 operational years. This value was reduced to $45.7 M and -$81.1 M if the mine only operated at half capacity or did not operate at all, respectively. The addition of hydrogen production powered by the installed variable renewable generation resulted in a slightly better net present value of $174.7 M if the mine operated as normal for 30 years. For the two other cases, the installation of an electrolyser resulted in significantly better results than if it had not been installed for the half capacity and no operation cases with net present costs of $90.9 M and -$7.1 M, respectively. A sensitivity analysis on these results show that while the hydrogen production only plays a minor role in site savings, a price of between $1.1/kg to $2.0/kg is necessary for the system to be economically justifiable. Therefore, the current study shows that the addition of an electrolyser can significantly reduce the risk of stranded assets in fully renewable mine sites by providing an additional revenue stream during mine turndown events.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号