首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In this paper the nitrogen elimination rates of different constructed wetland (CW) designs reported in literature are compared with those obtained for outdoor and indoor 2-stage vertical flow (VF) systems. The outdoor system is located about 150 km west of Vienna. Both stages are planted with Phragmites australis and the system has been operated for 4 years continuously. During this period the average value of the nitrogen elimination rate was 3.30 g N m(-2) d(-1). The indoor system comprises three parallel operated 2-stage VF systems and is located in the technical lab hall at BOKU University. The design of the indoor system resembles the outdoor system. However, there are a few differences: (1) the indoor systems are not planted, and (2) different filter media have been used for the main layer of the first stages. With the indoor system the highest nitrogen elimination rate achieved was 2.24 g N m(-2) d(-1) for the system with zeolite and impounded drainage layer. Similar results have been found in France for treating raw wastewater with VF and horizontal flow (HF) beds in series with nitrogen elimination rates of 1.89 and 2.82 g N m(-2) d(-1) for differently designed HF beds. The highest nitrogen elimination rates of 15.9 g N m(-2) d(-1) reported were for pilot-scale VF CWs treating high-strength synthetic wastewater (total nitrogen of 305 mg L(-1) in the influent) in Thailand. It has been shown that the outdoor two-stage VF CW system has one of the highest nitrogen elimination rates of CWs treating domestic wastewater.  相似文献   

2.
By using a two-stage constructed wetland (CW) system operated with an organic load of 40 gCOD.m(-2).d(-1) (2 m2 per person equivalent) average nitrogen removal efficiencies of about 50% and average nitrogen elimination rates of 980 g N.m(-2).yr(-1) could be achieved. Two vertical flow beds with intermittent loading have been operated in series. The first stage uses sand with a grain size of 2-3.2 mm for the main layer and has a drainage layer that is impounded; the second stage sand with a grain size of 0.06-4 mm and a drainage layer with free drainage. The high nitrogen removal can be achieved without recirculation thus it is possible to operate the two-stage CW system without energy input. The paper shows performance data for the two-stage CW system regarding removal of organic matter and nitrogen for the two year operating period of the system. Additionally, its efficiency is compared with the efficiency of a single-stage vertical flow CW system designed and operated according to the Austrian design standards with 4 m2 per person equivalent. The comparison shows that a higher effluent quality could be reached with the two-stage system although the two-stage CW system is operated with the double organic load or half the specific surface area requirement, respectively. Another advantage is that the specific investment costs of the two-stage CW system amount to 1,200 EUR per person (without mechanical pre-treatment) and are only about 60% of the specific investment costs of the singe-stage CW system.  相似文献   

3.
Constructed wetlands (CWs) use the same processes that occur in natural wetlands to improve water quality and are used worldwide to treat different qualities of water. This paper shows the results of an Austrian research project having the main goals to optimize vertical flow beds in terms of surface area requirement and nutrient removal, respectively. It could be shown that a subsurface vertical flow constructed wetland (SSVFCW) operated with an organic load of 20 g COD x m(-2) x d(-1) (corresponding to a specific surface area demand of 4 m2 per person) can fulfil the requirements of the Austrian standard regarding effluent concentrations and removal efficiencies. During the warmer months (May - October), when the temperature of the effluent is higher than 12 degrees C, the specific surface area might be further reduced. Even 2 m2 per person have been proven to be adequate. Enhanced nitrogen removal of 58% could be achieved with a two-stage system (first stage: grain size for main layer 1-4 mm, saturated drainage layer; and second stage: grain size for main layer 0.06-4 mm, free drainage) that was operated with an organic load of 80 g COD x m(-2) x d(-1) for the first stage (1 m2 per person), i.e. 40 g COD x m(-2) x d(-1) for the two-stage system (2 m2 per person). Although the two-stage system was operated with higher organic loads a higher effluent quality compared to a single-stage SSVFCW (grain size for main layer 0.06-4 mm, free drainage, organic load 20 g COD x m(-2) x d(-1)) could be reached.  相似文献   

4.
A biofilm system with Kaldnes biofilm carrier was used in these studies to cultivate bacteria responsible for both partial nitritation and Anammox processes. Due to co-existence of oxygen and oxygen-free zones within the biofilm depth, both processes can occur in a single reactor. Oxygen that inhibits the Anammox process is consumed in the outer layer of the biofilm and in this way Anammox bacteria are protected from oxygen. The impact of oxygen concentration on nitrogen removal rates was investigated in the pilot plant (2.1 m3), supplied with reject water from the Himmerfj?rden Waste Water Treatment Plant. The results of batch tests showed that the highest nitrogen removal rates were obtained for a dissolved oxygen (DO) concentration around 3 g O2 m(-3) At a DO concentration of 4 g O2 m(-3), an increase of nitrite and nitrate nitrogen concentrations in the batch reactor were observed. The average nitrogen removal rate in the pilot plant during a whole operating period oscillated around 1.3 g N m(-2)d(-1) (0.3 +/- 0.1 kg N m(-3)d(-1)) at the average dissolved oxygen concentration of 2.3 g O2 m(-3). The maximum value of a nitrogen removal rate amounted to 1.9 g N m(-2)d(-1) (0.47 kg N m(-3)d(-1)) and was observed for a DO concentration equal to 2.5 g O2 m(-3). It was observed that increase of biofilm thickness during the operational period, had no influence on nitrogen removal rates in the pilot plant.  相似文献   

5.
The ability of bacterial cultures to create biofilm brings a possibility to enhance biological wastewater treatment efficiency. Moreover, the ability of Anammox and Nitrosomonas species to grow within the same biofilm layer enabled a one-stage system for nitrogen removal to be designed. Such a system, with Kaldnes rings as carriers for biofilm growth, was tested in a technical pilot plant scale (2.1 m(3)) at the Himmerfj?rden Waste Water Treatment Plant (WWTP) in the Stockholm region. The system was directly supplied with supernatant originating from dewatering of digested sludge containing high ammonium concentrations. Nearly 1-year of operational data showed that during the partial nitritation/Anammox process, alkalinity was utilised parallel to ammonium removal. The process resulted in a small pH drop, and its relationship with conductivity was found. The nitrogen removal rate for the whole period oscillated around 1.5g N m(-2)d(-1) with a maximum value equal to 1.9 g N m(-2)d(-1). Parallel to the pilot plant experiment, a series of batch tests were run to investigate the influence on removal rates of different dissolved oxygen conditions and addition of nitrite. The highest nitrogen removal rate (5.2g N m(-2)2d(-1)) in batch tests was obtained when the Anammox process was stimulated by the addition of nitrite. In the simultaneous partial nitritation and Anammox process, the partial nitritation was the rate-limiting step.  相似文献   

6.
One of the limits for the application of constructed wetlands (CWs) in mountain regions (such as the Alps) is associated with the considerable land area requirements. In some mountain areas, the treatment of domestic wastewater at popular tourist destinations is particularly difficult during the summer, when the presence of visitors increases hydraulic and organic loads. This paper aims to evaluate whether a hybrid CW plant designed on the basis of the resident population only, can treat also the additional load produced by the floating population during the tourist period (summer, when temperatures are favourable for biological treatment), without a drastic decrease of efficiency and without clogging problems. The research was carried out by considering two operational periods: the first one was based on literature indications (3.2 m(2)/PE in the VSSF unit) and the second one assumed higher hydraulic and organic loads (1.3 m(2)/PE in the VSSF unit). The removal efficiency in the hybrid CW system decreased slightly from 94 to 88% for COD removal and from 78 to 75% for total N removal, even after applying a double hydraulic (from 55 to 123 L m(-2) d(-1)) and organic load (from 37 to 87 g COD m(-2) d(-1) and from 4.4 to 10.3 g TKN m(-2) d(-1)). The results showed that in the summer period the application of high loads did not affect the efficiency of the hybrid CW plant significantly, suggesting that it is possible to refer the CW design to the resident population only, with subsequent considerable savings in superficial area.  相似文献   

7.
Faecal sludge (FS) from the on-site sanitation systems is a nutrient-rich source but can contain high concentrations of toxic metals and chemicals and infectious micro-organisms. The study employed 3 vertical-flow CW units, each with a dimension of 5 x 5 x 0.65 m (width x length x media depth) and planted with cattails (Typha augustifolia). At the solid loading rate of 250 kg total solids (TS)/m(2).yr and a 6-day percolate impoundment, the CW system could achieve chemical oxygen demand (COD), TS and total Kjeldahl nitrogen (TKN) removal efficiencies in the range of 80-96%. A solid layer of about 80 cm was found accumulated on the CW bed surface after operating the CW units for 7 years, but no clogging problem has been observed. The CW percolate was applied to 16 irrigation sunflower plant (Helianthus annuus) plots, each with a dimension of 4.5 x 4.5 m (width x length). In the study, tap water was mixed with 20%, 80% and 100% of the CW percolate at the application rate of 7.5 mm/day. Based on a 1-year data in which 3 crops of plantation were experimented, the contents of Zn, Mn and Cu in soil of the experimental plots were found to increase with increase in CW percolate ratios. In a plot with 100% of CW percolate irrigation, the maximum Zn, Mn and Cu concentrations of 5.0, 12.3 and 2.5 mg/kg, respectively, were detected in the percolate-fed soil, whereas no accumulation of heavy metals in the plant tissues (i.e. leaves, stems and flowers) of the sunflower were detected. The highest plant biomass yield and oil content of 1000 kg/ha and 35%, respectively, were obtained from the plots fed with 20% or 50% of the CW percolate.  相似文献   

8.
Aerobic granular sludge grown in a sequential batch reactor was proposed as an alternative to anaerobic processes for organic matter and nitrogen removal from swine slurry. Aerobic granulation was achieved with this wastewater after few days from start-up. On day 140 of operation, the granular properties were: 5 mm of average diameter, SVI of 32 mL (g VSS)(-1) and density around 55 g VSS (L(granule))(-1). Organic matter removal efficiencies up to 87% and nitrogen removal efficiencies up to 70% were achieved during the treatment of organic and nitrogen loading rates (OLR and NLR) of 4.4 kg COD m(-3) d(-1) and of 0.83 kg N m(-3) d(-1), respectively. However, nitrogen removal processes were negatively affected when applied OLR was 7.0 kg COD m(-3) d(-1) and NLR was 1.26 kg N m(-3) d(-1). The operational cycle of the reactor was modified by reducing the volumetric exchange ratio from 50 to 6% in order to be able to treat the raw slurry without dilution.  相似文献   

9.
This paper describes a two-year performance evaluation of four different constructed wetland (CW) treatment systems designed by IRIDRA Srl, located in central Italy. All four CW systems were established to treat wastewater effluent from different tourist activities: (1) one single-stage CW for secondary treatment of domestic wastewater (30 p.e.) at a holiday farm site; (2) a hybrid compact system consisting of two stages, a horizontal flow (HF) system followed by a vertical flow (VF) system for the secondary treatment of effluent from a 140 p.e. tourist resort; (3) a single-stage vertical flow (VF) CW for a 100 p.e. mountain shelter; and (4) a pair of single-stage, HF CWs for the secondary treatment of segregated grey and black water produced by an 80 p.e. camping site. These tourism facilities are located in remote areas and share some common characteristics concerning their water management: they have high variability of water consumption and wastewater flow, depending on the season, weather and weekly regularities; they have no connection to a public sewer and most sites are located in a sensitive environment. Total suspended solids (TSS), chemical oxygen demand (COD), biochemical oxygen demand (BOD5), ammonium (N-NH4+), nitrate (N-NOx), total nitrogen (Ntot), total phosphorus (Ptot), total coliform (TC), faecal coliform (FC), E. coli removal efficiencies for all four CW systems are presented. The results from this study demonstrate the potential of CWs as a suitable technology for treating wastewater from tourism facilities in remote areas. A very efficient COD reduction (83-95%) and pathogen elimination (3-5 logs) have been achieved. Furthermore, the CWs are easily maintained, robust (not sensitive to peak flows), constructed with local materials, and operate with relatively low cost.  相似文献   

10.
The purpose of this study was to clarify the nitrogen (N) purification capacity of a paddy field in a recycling irrigation system. Irrigation water was sampled at 12-h intervals during the irrigation period from April to September 2003. In addition, ponded water in a paddy field was collected at three points (inlet, centre and outlet). Total amounts of N were 30.7 kg ha(-1) in inflow and 27.8 kg ha(-1) in outflow. Thus, the net outflow load was -2.9 kg ha(-1). The N removal rate constant when N removal is expressed as a 1st-order kinetic was 0.017-0.024 m d(-1). This value is close to values of wetlands and paddy fields in the literature. We found a good correlation between recycling ratio and N removal effect. These results indicate that the recycling irrigation system accumulates N in the irrigation/drainage system, and thus the paddy field does a good job of water purification by removing N.  相似文献   

11.
Nitrogen removal performance is reported for constructed wetlands treating subsurface drainage from irrigated and rain-fed dairy pastures in North Island, New Zealand. Flow-proportional sampling of inflow and outflow concentrations were combined with continuous flow records to calculate mass balances for the wetlands. Drainage flows from the irrigated catchment were 2.5-4 fold higher and N exports up to 5 fold higher per unit area than for the rain-fed catchment. Hydraulic and associated N loadings to the wetlands were highly pulsed, associated with rainfall, soil water status, and irrigation events. Transient pulses of organic nitrogen were an important form of N loss from the rain-fed landscape in the first year, and were very effectively removed in the wetland (> 90%). Median nitrate concentrations of approximately 10 g m(-3) in the drainage inflows were reduced by 15-67% during passage through the wetlands and annual nitrate-N loads by 16-61% (38-31 7 g N m(-2)y(-1)). Generation in the wetlands of net ammoniacal-N and organic-N (irrigated site) partially negated reduction in nitrate-N loads. The results show that constructed wetlands comprising 1-2% of catchment area can provide moderate reductions in TN export via pastoral drainage, but performance is markedly influenced by variations in seasonal loading and establishment/maturation factors.  相似文献   

12.
The treatment performance of a maturation pond (MP), the typical final polishing stage of an Advanced Pond System (APS), is compared with that of a surface-flow constructed wetland (CW) over 19 months. Both received approximately 67 mm d-1 of wastewater after passage through upstream stages of the APS. The MP, with greater sunlight exposure, had higher algal biomass (and associated suspended solids) than the CW, showed higher dissolved oxygen (DO) concentrations and greater diurnal variation in DO and pH. Neither polishing stages reduced nutrients markedly, with the CW exporting slightly more NH(3)-N and DRP, and less NO(3)-N than the MP. Disinfection was more efficient in the MP (geometric mean 1 log load removal, 12 MPN (100ml)-1) compared to the CW (0.47 log load removal, 53 MPN (100ml)-1). Incorporation of a final rock filter (28% of area) reduced median solids levels to < 10 g m(-3) in both the MP and CW. A hybrid between MPs and CWs with alternating zones of open-water (for enhanced disinfection and zooplankton grazing of algal solids) and wetland vegetation (promoting sedimentation and denitrification, and providing refugia for zooplankton) may provide more consistent effluent quality that either stage alone.  相似文献   

13.
A pilot scale treatment system was established in 2002 at the Laflèche Landfill in Eastern Ontario, Canada. The system consists of a series of treatment steps: a stabilisation basin (10,000 m3), a woodland peat trickling filter (5,200 m2), a subsurface flow constructed wetland planted in Phragmites sp. (2,600 m2), a surface flow constructed wetland planted in Typha sp. (3,600 m2) and a polishing pond (3,600 m2). The system operates from May to December with leachate being recycled within the landfill during the winter months. Hydraulic loading was increased three-fold over four operating seasons with nitrogen and organic mass loading increasing six-fold. Excellent removal efficiencies were observed with 93% BOD5, 90% TKN and 97% NH4-N removed under the highest loading conditions. Almost complete denitrification was observed throughout the treatment system with NO3-N concentrations never exceeding 5mg L(-1). The peat filter reached treatment capacity at a hydraulic loading of 4cm d(-1) and organic loading rate of 42 kg BOD ha(-1) d(-1), which is consistent with design criteria for vertical flow wetland systems and intermittent sand filters, The first order plug flow kinetic model was effective at describing TKN and ammonium removal in the SSF and FWS wetlands when background concentrations were taken into account. Ammonium removal k-values were consistent with the literature at 52.6 and 57.7 yr(-1) for the SSF and FWS wetlands, respectively, while TKN k-values at 6.9 and 7.7 yr(-1) were almost an order of magnitude lower than literature values, suggesting that leachate TKN could contain refractory organics not found in domestic wastewater.  相似文献   

14.
In South Sweden, free water surface wetlands have been built to treat wastewater from municipal wastewater treatment plants. Commonly, nitrogen removal has been the prime aim, though a significant removal of tot-P and BOD7 has been observed. In this study, performance data for 3-8 years from four large (20-28 ha) FWS wetlands have been evaluated. Two of them receive effluent from WWTP with only mechanical and chemical treatment. At the other two, the wastewater has also been treated biologically resulting in lower concentrations of BOD7 and NH4+-N. The wetlands performed satisfactorily and removed 0.7-1.5 ton N ha(-1) yr(-1) as an average for the time period investigated, with loads between 1.7 and 6.3 ton N ha(-1)yr(-1). Treatment capacity depended on the pre-treatment of the water, as reflected in the k20-values for N removal (first order area based model). In the wetlands with no biological pre-treatment, the k20-values were 0.61 and 1.1 m month(-1), whereas for the other two they were 1.7 and 2.5 m month(-1). P removal varied between 10 and 41 kg ha(-1) yr(-1), and was related to differences in loads, P speciation and to the internal cycling of P in the wetlands.  相似文献   

15.
We measured N2O, CH4 and CO2 fluxes in horizontal and vertical flow constructed wetlands (CW) and in a riparian alder stand in southern Estonia using the closed chamber method in the period from October 2001 to November 2003. The average rates of N20, CH4 and CO2 emission from the riparian gray alder stand were from -0.4 to 58 microg N2O-N m(-2) h(-1) and 0.1-265 microg CH4-C m(-2) h(-1), 55-61 mg CO2-C m(-2) h(-1), respectively. The average N2O-N emission from the microsites above the inflow pipes of horizontal subsurface flow (HSSF) CWs was 6.4-31 microg N2O-N m(-2) h(-1), whereas the outflow microsites emitted 2.4-8 microg N2O-N m(-2) h(-1). In vertical subsurface flow (VSSF) beds the same value was 35.6-44.7 microg N2O-N m(-2) h(-1). The average CH4 emission from the inflow and outflow microsites in the HSSF CWs differed significantly ranging from 640 to 9715 and from 30 to 770 microg CH4-C m(-2) h(-1), respectively. The average CO2 emission was somewhat higher in VSSF beds (140-291 mg CO2-C m(-2) h(-1)) and at inflow microsites of HSSF beds (61-140 mg CO2-C m(-2) h(-1)). The global warming potential (GWP) from N2O and CH4 was comparatively high in both types of CWs (4.8 +/- 9.8 and 6.8 +/- 16.2 t CO2 eq ha(-1) a(-1) in the HSSF CW 6.5 +/- 13.0 and 5.3 +/- 24.7 t CO2 eq ha(-1) a(-1) in the hybrid CW, respectively). The GWP of riparian alder forest from both N2O and CH4 was relatively low (0.4 +/- 1.0 and 0.1 +/- 0.30 t CO2 eq ha(-1) a(-1), respectively), whereas the CO2-C flux was remarkable (3.5 +/- 3.7 t ha(-1) a(-1). The global influence of CWs is not significant. Even if all the global domestic wastewater were treated by wetlands, their share in the trace gas emission budget would be less than 1%.  相似文献   

16.
Traditional nitrification/denitrification is not suitable for nitrogen removal when wastewater contains high concentrations of ammonium nitrogen and low concentrations of biodegradable carbon. Recently, a deammonification process was developed and proposed as a new technology for treatment of such streams. This process relies on a stable interaction between aerobic bacteria Nitrosomonas, that accomplish partial nitritation and anaerobic bacteria Planctomycetales, which conduct the Anammox reaction. Simultaneous performance of these two processes can lead to a complete autotrophic nitrogen removal in one single reactor. The experiments where nitrogen was removed in one reactor were performed at a technical-scale moving-bed pilot plant, filled with Kaldnes rings and supplied with supernatant after dewatering of digested sludge. It was found that a nitrogen removal rate obtained at the pilot plant was 1.9 g m(-2) d(-1). Parallel to the pilot plant run, a series of batch tests were carried out under anoxic and aerobic conditions. Within the batch tests, where the pilot plant's conditions were simulated, removal rates reached up to 3 g N m(-2)d(-1). Moreover, the batch tests with inhibition of Nitrosomonas showed that only the Anammox bacteria (not anoxic removal by Nitrosomonas) are responsible for nitrogen removal.  相似文献   

17.
This work focuses on the implementation of high performance systems to the wastewater treatment of sugar factories. For this purpose, systems with immobilised bacteria were studied. For the hydrolysis of organic matter and denitrification, fluidized bed reactors were used. The nitrification was studied with an airlift reactor system. Both hydrolysis and nitrogen elimination were investigated on laboratory and pilot scales in sugar factories. Although with porous materials higher biomass concentrations are attainable for the hydrolysis (up to 55 kg/m3), for economical reasons sand was used (22.5 kg/m3) for the pilot scale-study. With a pilot-scale reactor (volume 1 m3) the maximum sucrose conversion rate achieved with sand in the first campaign was 52 kg/(m3 d). For the nitrogen elimination on the pilot scale, a system with denitrification and nitrification was combined. The highest performance for the nitrification (reactor volume: 0.68 m3) with pumice as support material was 1.2 kg NH4-N/(m3 d), limiting the whole system. The denitrification rate (reactor volume: 0.12 m3) was four times higher (3.5-5 kg NO3-N/(m3 d). Rules of the modelling of the system are discussed.  相似文献   

18.
Pre-denitrification in biofilters is limited by the amount of easily degradable organic substrate, resulting in relatively high requirements for external carbon. The combination of pre-DN, N and post-DN filters is much more advisable for most municipal wastewaters, because the recycle rate can be reduced and external carbon can be saved. For minimum use of external carbon, 100-150% recycle rate should not be exceeded. Then, approximately 50-60% of the total NO3-N can be depleted in the pre-DN stage. On average, 10 g total (t) COD/g NO3-N were required in the pre-DN stage for denitrification in the pilot and full-scale plant and 0.4-0.5 kg NO3-N/(m(3)DN d) can be reached without external carbon. As only 40-70% of the COD load is eliminated in the pre-DN, the remaining COD load is removed in the nitrification stage. 1 kg COD/(m(3) d) suppresses nitrification rates by approximately 0.1 kg NH4-N/(m(3) d). For nitrification rates, > 0.5 kg NH4N/(m(3) d) at 12 degrees C not more than 2 kg COD/(m(3) d) may be eliminated in the nitrification.  相似文献   

19.
An innovative technology for the biological treatment of wastewater in regions with sufficient solar radiation based on the simultaneous growth and degradation processes of algal and bacterial biomass is presented. The aim of the work is the improvement of pond technology through the formation of stable algae-bacteria aggregates, which a) permit a simple separation of the algal biomass by gravity sedimentation, b) enable a high removal efficiency for organic carbon and nutrients, and c) are independent in terms of oxygen provision through algal photosynthesis. Algae-bacteria aggregates could be developed with a suitable algal species (Chlorella vulgaris, Strain Hamburg) as a 'model organism' in a wastewater environment. The morphology of algal-bacterial flocs is similar to activated sludge flocs. They are stable and settle quickly. Floc size ranged between 400 and 800 microm. Results of our experiments with an artificially irradiated lab-scale system, operated in continuous flow mode, revealed that even at a relatively short hydraulic detention time of two days, a high elimination capacity of 9.96 g N m(-2) d(-1) and 0.87g Pm(-2) d(-1) can be achieved. Recent investigations confirmed that floc formation of unicellular algae and wastewater bacteria also could be developed and maintained in a pilot-scale system with a water depth of 0.5 m.  相似文献   

20.
A new type of hybrid constructed wetland (CW), consisting of both vertical-baffled flow wetland (VBFW) and horizontal subsurface flow wetland (HSFW), has been deployed in Southern China to naturally accelerate the removal of organic matter and nitrogen. The hybrid CW system is characterised by a combination of continuous baffled flow vertical wetland and 'S' pattern horizontal subsurface flow wetland with natural aeration ditches to increase the concentration of dissolved oxygen in the HSFW bed. An internal circulatory system from the HSFW effluent back to the VBFW may optionally be operated to enhance the biological denitrification effect. Cyperus alternifolius is the main macrophyte in the wetland bed. The performance of the hybrid CW was studied with a pilot-scale system and three full-scale systems for municipal sewage treatment in Southern China. The results suggest that this new hybrid CW can achieve removal efficiencies of chemical oxygen demand, suspended solids, ammonia nitrogen, total nitrogen, and total phosphorus of better than 83.6, 95.0, 71.7, 64.5 and 68.1% respectively, with a specific wetland bed area of 0.70-0.93 m(2) PE(-1). The mean effluent concentrations of these parameters would meet the regulatory discharge limits for wastewater treatment systems (GB18918, 2002) and reuse in the context of agricultural irrigation solutions in China.  相似文献   