1.
In this study, the best artificial intelligence method is investigated to estimate the measured convective heat transfer coefficient and pressure drop of R134a flowing downward inside a vertical smooth copper tube having an inner diameter of 8.1 mm and a length of 500 mm during annular flow numerically. R134a and water are used as working fluids in the tube side and annular side of a double tube heat exchanger, respectively. The ANN training sets have the experimental data of in-tube condensation tests including six different mass fluxes of R134a such as 260, 300, 340, 400, 456 and 515 kg m− 2 s− 1, two different saturation temperatures of R134a such as 40 and 50 °C and heat fluxes ranging from 10.16 to 66.61 kW m− 2. The quality of the refrigerant in the test section is calculated considering the temperature and pressure obtained from the experiment. The pressure drop across the test section is directly measured by a differential pressure transducer. Input of the ANNs are the measured values of test section such as mass flux, heat flux, the temperature difference between the tube wall and saturation temperature, average vapor quality, while the outputs of the ANNs are the experimental condensation heat transfer coefficient and measured pressure drop in the analysis. Condensation heat transfer characteristics of R134a are modeled to decide the best approach using several artificial neural network (ANN) methods such as multilayer perceptron (MLP), radial basis networks (RBFN), generalized regression neural network (GRNN) and adaptive neuro-fuzzy inference system (ANFIS). Elimination process of the ANN methods is performed by means of 183 data points, divided into two sets randomly, obtained in the experiments. Sets of test and training/validation include 33 and 120/30 data points respectively for the elimination process. Validation process, in terms of various experimental conditions, is done by means of 368 experimental data points having 68 data points for test set and 300 data points for training set. In training phase, 5-fold cross validation is used to determine the best value of ANNs control parameters. The ANNs performances were measured by means of relative error criteria with the usage of unknown test sets. The performance of the method of multi layer perceptron (MLP) with 5-13-1 architecture and radial basis function networks (RBFN) were found to be in good agreement, predicting the experimental condensation heat transfer coefficient and pressure drop with their deviations being within the range of ± 5% for all tested conditions. Dependency of outputs of the ANNs from input values is also investigated in the paper.  相似文献   

2.
The two-phase pressure drop of the pure refrigerant HFC-134a during condensation inside a vertical tube-in-tube heat exchanger was investigated. The double tube test section was 0.5 m long with refrigerant flowing in the inner tube and cooling water flowing in the annulus. The inner tube was constructed from smooth copper tubing of 8.1 mm inner diameter and 9.52 mm outer diameter. The test runs were performed at average condensing temperatures of 40–50 °C. The mass fluxes were between 260 and 515 kg m− 2 s− 1 and the heat fluxes between 11.3 and 55.3 kW m− 2. The quality of the refrigerant in the test section was calculated using the temperature and pressure obtained from the experiment. The pressure drop across the test section was directly measured by a differential pressure transducer. A new correlation for the two-phase friction factor of R134a flow is proposed by means of the equivalent Reynolds number model. The effects of heat flux, mass flux and condensation temperature on the pressure drop are also discussed.  相似文献   

3.
This paper reports the experimental investigation of a model for predicting flow pattern transitions and for the validation of void fraction models and correlations proposed in the authors' previous publications and for the identification of flow regimes in data corresponding to annular flow downward condensation of R134a in a vertical smooth copper tube having an inner diameter of 8.1 mm and a length of 500 mm. R134a and water are used as working fluids on the tube side and annular side, respectively, of a double tube heat exchanger. Condensation experiments are done at mass fluxes of 260 and 515 kg m− 2 s− 1 in the high mass flux region of R134a. The condensing temperatures are between 40 and 50 °C; heat fluxes are between 10.16 and 66.61 kW m− 2. A mathematical model proposed by Soliman based on the models of Kosky and Lockhart–Martinelli is used to determine the condensation film thickness of R134a. Comparative void fraction values are determined indirectly using the measured data under laminar and turbulent flow conditions together with various void fraction models and correlations reported in the literature. There is good agreement between the void fraction results obtained from the theoretical model and those obtained from the void fraction models of Soliman, Chisholm and Armand, Turner and Wallis, Smith, Spedding and Spence previously proposed in the authors' publications and tested against their experimental database. Various well-known flow regime correlations from the literature are investigated to identify the flow regime occurring in the test tube, the correlations of Taitel and Dukler, Dobson, Akbar et al., Breber et al., Cavallini et al., and Sardesai et al. can provide accurate estimates of the annular flow conditions in spite of their different working conditions.  相似文献   

4.
The two-phase heat transfer coefficients of pure HFC-134a condensing inside a smooth tube-in-tube heat exchanger are experimentally investigated. The test section is a 0.5 m long double tube with refrigerant flowing in the inner tube and cooling water flowing in the annulus. The inner tube is constructed from smooth copper tubing of 9.52 mm outer diameter and 8.1 mm inner diameter. The test runs are performed at average saturation condensing temperatures between 40–50 °C. The mass fluxes are between 260 and 515 kg m− 2s− 1 and the heat fluxes are between 11.3 and 55.3 kW m− 2. The quality of the refrigerant in the test section is calculated using the temperature and pressure obtained from the experiment. The average heat transfer coefficient of the refrigerant is determined by applying an energy balance based on the energy transferred from the test section. The effects of heat flux, mass flux and condensation temperature on the heat transfer coefficients are also discussed. Eleven well-known correlations for annular flow are compared to each other using a large amount of data obtained from various experimental conditions. A new correlation for the condensation heat transfer coefficient is proposed for practical applications.  相似文献   

5.
New correlations of the two-phase multiplier and heat transfer coefficient of R134a during evaporation in a multiport minichannel at low mass flux are proposed. The experimental results were obtained from a test using a counter-flow tube-in-tube heat exchanger with refrigerant flowing in the inner tube and hot water in the gap between the outer and inner tubes. Test section is composed of the extruded multiport aluminium inner tube with an internal hydraulic diameter of 1.2 mm and an acrylic outer tube with an internal hydraulic diameter of 25.4 mm. The experiments were performed at heat fluxes between 10 and 35 kW/m2, and a refrigerant mass flux between 45 and 155 kg/(m2 s). Some physical parameters that influenced the frictional pressure drop and heat transfer coefficient are examined and discussed in detail. The pressure drop and heat transfer coefficient results are also compared with existing correlations. Finally, new correlations for predicting the frictional pressure drop and heat transfer coefficient at low mass fluxes are proposed.  相似文献   

6.
In the present study, the void fraction and film thickness of pure R-134a flowing downwards in a vertical condenser tube are indirectly determined using relevant measured data together with an annular flow model and various void fraction models reported in the open literature. The vertical test section is a countercurrent flow double tube heat exchanger with refrigerant flowing down in the inner tube and cooling water flowing upward in the annulus. The inner tube is made from smooth copper tubing of 9.52 mm outer diameter with a length of 0.5 m. The experimental runs are carried out at average saturated condensing temperatures of 40 and 50 °C, and mass velocities are around 456 kg m− 2 s− 1, over the vapour quality range 0.82–0.93, while the heat fluxes are between 45.60 and 50.90 kW m− 2. Analysis based on simple void fraction models of the annular flow pattern are presented for forced convection condensation of pure R134a, taking into account the effect of the different saturation temperatures at high mass flux conditions. The comparisons of calculated film thickness show that the void fraction models of Spedding and Chen, and Chisholm and Armand are the most accurate ones with the experimental data due to their low deviation with Whalley's annular flow model over 35 void fraction models presented in this paper.  相似文献   

7.
The two-phase pressure drop characteristics of the pure refrigerants R410a, R502, and R507a during condensation inside a horizontal tube-in-tube heat exchanger were investigated to determine the two-phase friction factor, the frictional pressure drop, and the total pressure drop. The two-phase friction factor and frictional pressure drop are predicted by means of an equivalent Reynolds number model. Eckels and Pate's experimental data, presented in Choi et al.'s study provided by NIST, were used in the analysis. In their experimental setup, the horizontal test section was a 3.81 m long countercurrent flow double tube heat exchanger with refrigerant flowing in the inner smooth copper tube (8.01 mm i.d.) and cooling water flowing in the annulus (13.7 mm i.d.). Their test runs were performed at saturated condensing temperatures from 38.33 °C to 51.78 °C while the mass fluxes were between 119 and 617 kg m−2 s−1 for the horizontal test section. The separated flow model was modified by ten different void fraction models and correlations, as well as six different correlations of friction factors, in order to determine the best combination for the validation of the experimental pressure drop values. Carey's friction factor was found to be the most predictive. The refrigerant side total and frictional pressure drops were determined within ± 30% using the above friction factor and the void fraction combinations of Carey, Baroczy, and Armand for R410a; and those of Carey, Spedding and Spence, and Rigot for R502 and R507a. The equivalent Reynolds number model was modified using the void fraction correlation of Rigot in order to determine the frictional condensation pressure drop and the two-phase friction factor. The effects of vapor quality and mass flux on the pressure drop are discussed in this paper. The importance of using the alternative void fraction and friction factor models and correlations for the separated flow model is also addressed.  相似文献   

8.
9.
This experimental study is performed to investigate condensation heat transfer coefficient of R-134a flow inside corrugated tube with different inclinations. Different inclinations of test condenser ranging from − 90° to + 90° and various flow mass velocities in the range of 87 to 253 [kg/m2s] are considered in this study. Data analysis showed that change in the tube inclination had a significant effect on condensation heat transfer behavior. At low mass velocities, and low vapor qualities, the highest condensation heat transfer coefficient was obtained for α = + 30° which was 1.41 times greater than the least one obtained for α = − 90°. The results also showed that at all mass velocities, the highest average heat transfer coefficients were achieved for α = + 30°. Based on the experimental results, a new empirical correlation is proposed to predict the condensation heat transfer coefficient of R134a flow in corrugated tubes with different inclinations.  相似文献   

10.
The void fraction of R134a condensing inside a vertical smooth tube is experimentally investigated in this study. The vertical test section is a 0.5 m long countercurrent flow double tube heat exchanger with refrigerant flowing down the inner tube and cooling water flowing upward in the annulus. The inner tube is made from smooth copper tubing and has an 8.1 mm inner diameter. The test runs are done at an average saturated condensing temperature of 40 °C. The average qualities are between 0.8 and 0.99 while the mass fluxes are 300 kg m− 2s− 1 and the heat fluxes are between 22 and 39.8 kW m− 2. The void fractions are indirectly determined using relevant measured data together with various void fraction models and correlations reported in the open literature. The friction factors obtained from various void fraction models and correlations are compared with each other and also with those determined from graphical information provided by Bergelin et al. The effect of void fraction alteration on the momentum pressure drop is also presented.  相似文献   

11.
This paper is the second of a two-part study concerning two-phase flow and heat transfer characteristics of R134a in a micro-channel heat sink incorporated as an evaporator in a refrigeration cycle. Boiling heat transfer coefficients were measured by controlling heat flux (q″ = 15.9 − 93.8 W/cm2) and vapor quality (xe = 0.26 − 0.87) over a broad range of mass velocity. While prior studies point to either nucleate boiling or annular film evaporation (convective flow boiling) as dominant heat transfer mechanisms in small channels, the present study shows heat transfer is associated with different mechanisms for low, medium and high qualities. Nucleate boiling occurs only at low qualities (xe < 0.05) corresponding to very low heat fluxes, and high fluxes produce medium quality (0.05 < xe < 0.55) or high quality (xe > 0.55) flows dominated by annular film evaporation. Because of the large differences in heat transfer mechanism between the three quality regions, better predictions are possible by dividing the quality range into smaller ranges corresponding to these flow transitions. A new heat transfer coefficient correlation is recommended which shows excellent predictions for both R134a and water.  相似文献   

12.
Heat transfer and pressure drop characteristics of four microfin tubes were experimentally investigated for condensation of refrigerants R134a, R22, and R410A in four different test sections. The microfin tubes examined during this study consisted of 8.92, 6.46, 5.1, and 4 mm maximum inside diameter. The effect of mass flux, vapor quality, and refrigerants on condensation was investigated in terms of the heat transfer enhancement factor and the pressure drop penalty factor. The pressure drop penalty factor and the heat transfer enhancement factor showed a similar tendency for each tube at given vapor quality and mass flux. Based on the experimental data and the heat-momentum analogy, correlations for the condensation heat transfer coefficients in an annular flow regime and the frictional pressure drops are proposed.  相似文献   

13.
An experimental study of the critical heat flux (CHF) in horizontal and vertical tubes cooled with R-134a has been completed. The investigated ranges of flow parameters in R-134a were outlet pressures of 1.31, 1.67 and 2.03 MPa (8, 10 and 12 MPa in water-equivalent values), mass flux from 500 to 3000 kg m−2 s−1 (700-4300 kg m−2 s−1 in water-equivalent values), and critical quality from −0.1 to +0.9. The wide range of qualities was achieved using tubes of different heated lengths and two-phase flow at the test-section inlet.The R-134a CHF data obtained in the vertical orientation agreed with the R-134a-equivalent CHF values from the water-based CHF look-up table. The effect of orientation on CHF was found to depend on mass flux, quality and pressure, as well as the limiting critical quality. This effect is strong at low mass fluxes, but disappears at high mass fluxes. At qualities higher than the limiting critical qualities, the CHF in horizontal flow can be greater than the corresponding value in vertical flow at the same critical quality conditions. A maximum reduction in CHF due to flow stratification was observed at qualities between the limiting critical qualities for horizontal and vertical flows.The orientation effect on CHF appears to be much stronger for R-134a than for water flow at the same critical quality, equivalent mass flux (based on vertical flow fluid-to-fluid modeling relationships) and density ratio. This behavior is primarily due to the larger density difference between liquid and vapor and the lower vapor velocity in R-134a.  相似文献   

14.
An experimental study of tube side boiling heat transfer of HFC-134a has been conducted in a single-pass, counter-current flow heat exchanger under an electric field. By applying 0–8 kV to a concentric inner electrode, the mechanics of EHD induced flow and heat transfer augmentation/suppression have been investigated for flow conditions with inlet qualities of 0% to 60%, mass fluxes from 100 kg/m2 s to 500 kg/m2 s, and heat flux levels between 10 kW/m2 and 20 kW/m2. A theoretical Steiner type two-phase flow pattern map for flow boiling in the annular channel under applied DC high voltage is also developed. The flow regimes encountered in the convective boiling process have been reconstructed experimentally and compared with the proposed EHD flow regime map. The results show that when the proposed dimensionless criterion Md Re2 is satisfied, EHD interfacial forces have a strong influence on the flow pattern which is considered to be the primary mechanism affecting the increase in pressure drop and the augmentation or even suppression of heat transfer.  相似文献   

15.
This paper presents an experimental investigation of laminar film condensation of R134a in a vertical smooth tube having an inner diameter of 7–8.1 mm and a length of 500 mm. Condensation experiments were performed at mass fluxes of 29 and 263 kg m?2 s?1. The pressures were between 0.77 and 0.1 MPa. The heat transfer coefficient, film thickness and condensation rate during downward condensing film were determined. The results show that an interfacial shear effect is significant for the laminar condensation heat transfer of R134a under the given conditions. A new correlation for the condensation heat transfer coefficient is proposed for practical applications.  相似文献   

16.
Evaporation heat transfer characteristics of carbon dioxide (CO2) in a horizontal tube are experimentally investigated. The test tube has an inner diameter of 6.0 mm, a wall thickness of 1.0 mm, and a length of 1.4 m. Experiments are conducted at saturation temperatures of 5 and 10 °C, mass fluxes from 170 to 320 kg/m2 s and heat fluxes from 10 to 20 kW/m2. Partial dryout of CO2 occurs at a lower quality as compared to the conventional refrigerants due to a higher bubble growth within the liquid film and a higher liquid droplet entrainment, resulting a rapid decrease of heat transfer coefficients. The effects of mass flux, heat flux, and evaporating temperature are explained by introducing unique properties of CO2, flow patterns, and dryout phenomenon. In addition, the heat transfer coefficient of CO2 is on average 47% higher than that of R134a at the same operating conditions. The Gungor and Winterton correlation shows poor prediction of the boiling heat transfer coefficient of CO2 at low mass flux, while it yields good estimation at high mass flux.  相似文献   

17.
The two-phase heat transfer coefficient and pressure drop of pure HFC-134a condensing inside a smooth helically coiled concentric tube-in-tube heat exchanger are experimentally investigated. The test section is a 5.786 m long helically coiled double tube with refrigerant flowing in the inner tube and cooling water flowing in the annulus. The inner tube is made from smooth copper tubing of 9.52 mm outer diameter and 8.3 mm inner diameter. The outer tube is made from smooth copper tubing of 23.2 mm outer diameter and 21.2 mm inner diameter. The heat exchanger is fabricated by bending a straight copper double-concentric tube into a helical coil of six turns. The diameter of coil is 305 mm. The pitch of coil is 35 mm. The test runs are done at average saturation condensing temperatures ranging between 40 and 50 °C. The mass fluxes are between 400 and 800 kg m−2 s−1 and the heat fluxes are between 5 and 10 kW m−2. The pressure drop across the test section is directly measured by a differential pressure transducer. The quality of the refrigerant in the test section is calculated using the temperature and pressure obtained from the experiment. The average heat transfer coefficient of the refrigerant is determined by applying an energy balance based on the energy rejected from the test section. The effects of heat flux, mass flux and, condensation temperature on the heat transfer coefficients and pressure drop are also discussed. It is found that the percentage increase of the average heat transfer coefficient and the pressure drop of the helically coiled concentric tube-in-tube heat exchanger, compared with that of the straight tube-in-tube heat exchanger, are in the range of 33–53% and 29–46%, respectively. New correlations for the condensation heat transfer coefficient and pressure drop are proposed for practical applications.  相似文献   

18.
This study compares well-known two-phase pressure drop models with the experimental results of a condensation pressure drop of (i) R600a in a 1 m long horizontal smooth copper tube with an inner diameter of 4 mm, outer diameter of 6 mm and (ii) R134a in a 0.5 m vertical smooth copper tube with an inner diameter of 8.1 mm and outer diameter of 9.52 mm. Different vapour qualities (0.45–0.9 for R600a and 0.7–0.95 for R134a), various mass fluxes (75–115 kg m?2 s?1 for R600a and 300–400 for R134a kg m?2 s?1) and different condensing temperatures (30–43 °C for R600a and 40–50 °C for R134a) were tested under annular flow conditions. The quality of the refrigerant in the test section was calculated considering the temperature and pressure obtained from the experiment. The pressure drop across the test section was directly measured with a differential pressure transducer. The most agreeable correlations of various available options were then identified according to the results of analysis during annular flow regime.  相似文献   

19.
The two-phase heat transfer coefficient and pressure drop of HFC-134a during evaporation inside a smooth helically coiled concentric tube-in-tube heat exchanger are experimentally investigated. The test section is a 5.786-m long helically coiled tube with refrigerant flowing in the inner tube and heating water flowing in the annulus. The inner tube is made from copper tubing of 9.52 mm outer diameter and 7.2 mm inner diameter. The heat exchanger is fabricated by bending a straight copper tube into a spiral coil. The diameter of coil is 305 mm. The test run are done at average saturated evaporating temperatures ranging between 10 and 20 °C. The mass fluxes are between 400 and 800 kg m−2 s−1 and the heat fluxes are between 5 and 10 kW m−2. The inlet quality of the refrigerant in the test section is calculated using the temperature and pressure obtained from the experiment. The pressure drop across the test section is directly measured by a differential pressure transducer. The effects of heat flux, mass flux and, evaporation temperature on the heat transfer coefficients and pressure drop are also discussed. The results from the present experiment are compared with those obtained from the straight tube reported in the literature. New correlations for the convection heat transfer coefficient and pressure drop are proposed for practical applications.  相似文献   

20.
The characteristics of local heat transfer and pressure drops were experimentally investigated using condensing R134a two-phase flow, in single rectangular tubes, with hydraulic diameter of 0.494, 0.658, and 0.972 mm. New experimental techniques were used to measure the in-tube condensation heat transfer coefficient especially for the low heat and mass flows. Tests were performed for a mass flux of 100, 200, 400, and 600 kg/m2s, a heat flux of 5 to 20 kW/m2, and a saturation temperature of 40℃. In this study, effect of heat flux, mass flux, vapor qualities, and hydraulic diameter on flow condensation were investigated and the experimental local condensation heat transfer coefficients and frictional pressure drop are shown. The experimental data of condensation Nusselt number are compared with previous correlations, most of which are proposed for the condensation of pure refrigerant in a relatively large inner diameter round tubes.  相似文献   