首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A Multi-Purpose Plasma (MP(2)) facility has been renovated from Hanbit mirror device [Kwon et al., Nucl. Fusion 43, 686 (2003)] by adopting the same philosophy of diversified plasma simulator (DiPS) [Chung et al., Contrib. Plasma Phys. 46, 354 (2006)] by installing two plasma sources: LaB(6) (dc) and helicon (rf) plasma sources; and making three distinct simulators: divertor plasma simulator, space propulsion simulator, and astrophysics simulator. During the first renovation stage, a honeycomblike large area LaB(6) (HLA-LaB(6)) cathode was developed for the divertor plasma simulator to improve the resistance against the thermal shock fragility for large and high density plasma generation. A HLA-LaB(6) cathode is composed of the one inner cathode with 4 in. diameter and the six outer cathodes with 2 in. diameter along with separate graphite heaters. The first plasma is generated with Ar gas and its properties are measured by the electric probes with various discharge currents and magnetic field configurations. Plasma density at the middle of central cell reaches up to 2.6 x 10(12) cm(-3), while the electron temperature remains around 3-3.5 eV at the low discharge current of less than 45 A, and the magnetic field intensity of 870 G. Unique features of electric property of heaters, plasma density profiles, is explained comparing with those of single LaB(6) cathode with 4 in. diameter in DiPS.  相似文献   

2.
We have developed a novel and economical neutral-beam injection system by employing a washer-gun plasma source. It provides a low-cost and maintenance-free ion beam, thus eliminating the need for the filaments and water-cooling systems employed conventionally. In our primary experiments, the washer gun produced a source plasma with an electron temperature of approximately 5 eV and an electron density of 5 × 10(17) m(-3), i.e., conditions suitable for ion-beam extraction. The dependence of the extracted beam current on the acceleration voltage is consistent with space-charge current limitation, because the observed current density is almost proportional to the 3∕2 power of the acceleration voltage below approximately 8 kV. By optimizing plasma formation, we successfully achieved beam extraction of up to 40 A at 15 kV and a pulse length in excess of 0.25 ms. Its low-voltage and high-current pulsed-beam properties enable us to apply this high-power neutral beam injection into a high-beta compact torus plasma characterized by a low magnetic field.  相似文献   

3.
The results of first experiments on the investigation of plasma of electron cyclotron resonance (ECR) discharge, sustained by CW radiation of technological gyrotron with frequency 24 GHz are considered. The parameters of nitrogen plasma of ECR discharge in magnetic field up to 1 T were investigated by Langmuir probe in the pressure range 10(-4)-10(-2) mbar under different values of microwave power. Depending on gas pressure and power of microwave radiation, the typical temperature and density of electrons could attain values of 1-5 eV and 10(11)-10(12) cm(-3), respectively. The prospects for using of ECR discharge for plasma chemical decomposition of silicon tetrafluoride (SiF(4)) have been experimentally demonstrated. Plasma was created from SiF(4) and hydrogen (H(2)) gas mixture and heated by microwave radiation in ECR conditions. Using the method of mass-spectrometry analysis of the gas at the outlet from the reactor and the weighting method, the content of the resultants of SiF(4) decomposition as a function of process parameters was investigated. It was shown that SiF(4) decomposition degree strongly depends on the microwave power, gas pressure in the reactor, gas flow rates, and can attain the value of 50%. The possible applications of PECVD method based on ECR discharge for production of isotopically pure elements with high deposition rate are discussed.  相似文献   

4.
A plasma study is performed in order to construct a cell for plasma acceleration purpose. As well, a multicell design is introduced for the injection of beam driver application. The suggested idea is experimentally demonstrated for two plasma cell configuration. The preformed plasma is obtained by a symmetrically driven capacitive audio frequency discharge. It is featured by its moderate pressure of 0.1-0.2 Torr, low consumption power of 130 W maximum, low discharge voltage and frequency up to 950 V and 20 kHz, respectively, and high plasma density from 10(11) to 10(15) cm(-3). The electron temperature obtained by Langmuir double probe varies from 1 up to 16 eV. It is observed that the increases of the discharge voltage and frequency enlarge the plasma parameters to their maximum values. The plasma cell filled with different gases demonstrates that the Ar and He gases manifest the highest ionization efficiency exceeding 100% at 950 V and 20 kHz. The formed plasma is cold; its density is uniform and stable along the positive column for long competitive lifetime. Showing that it follows the conditions to enhance particle acceleration and in conjunction with its periphery devices form a plasma cell that could be extended to serve this purpose. Demonstrating that an injected electron beam into the extended preformed plasma could follow, to long distance, a continuous trajectory of uniform density. Such plasma generated by H(2) or Ar gases is suggested to be used, respectively, for low-density or higher density beam driver.  相似文献   

5.
In this work, the design and performance of new type ion source are described. The discharge mechanism of the source is based on creating an arc discharge through a saddle electric field inside the discharge tube. The saddle electric field is created by immersing an annular anode inside the discharge tube covered from the upper and lower ends with two flanges. These two flanges act as cathodes. The discharge tube is surrounded by a solenoid coil which produces an axial magnetic field (up to 400 G) measured at the center of the source. Measurements have been performed to find out the influence of arc power, pressure, discharge voltage, magnetic field, and extracting voltage on the ion source properties. The source yields an argon ion current of approximately 0.6 mA and electron current of approximately 4 mA at normal operating conditions (extraction voltage V(ex)=7 kV, pressure of 5.5x10(-4) Torr, V(arc)=400 V, I(arc)=1 A, B=200 G). It showed an energy spread of 20 eV at a discharge voltage of 400 V and an extraction voltage of 3 kV.  相似文献   

6.
We describe a diagnostic to measure the parallel electron velocity distribution in a magnetized plasma that is overdense (ω(pe) > ω(ce)). This technique utilizes resonant absorption of whistler waves by electrons with velocities parallel to a background magnetic field. The whistler waves were launched and received by a pair of dipole antennas immersed in a cylindrical discharge plasma at two positions along an axial background magnetic field. The whistler wave frequency was swept from somewhat below and up to the electron cyclotron frequency ω(ce). As the frequency was swept, the wave was resonantly absorbed by the part of the electron phase space density which was Doppler shifted into resonance according to the relation ω - k(∥)v(∥) = ω(ce). The measured absorption is directly related to the reduced parallel electron distribution function integrated along the wave trajectory. The background theory and initial results from this diagnostic are presented here. Though this diagnostic is best suited to detect tail populations of the parallel electron distribution function, these first results show that this diagnostic is also rather successful in measuring the bulk plasma density and temperature both during the plasma discharge and into the afterglow.  相似文献   

7.
A device has been constructed for the study of the interaction between a fast ion beam and a target plasma of separately controllable parameters. The beam of either hydrogen or helium ions has an energy of 1-4 keV and a total current of 0.5-2 A. The beam energy and beam current can be varied separately. The ion source plasma is created by a pulsed (0.2-10-ms pulse length) discharge in neutral gas at up to 3 x 10(-3) Torr. The neutrals are pulsed into the source chamber, allowing the neutral pressure in the target region to remain less than 5 x 10(-5) Torr at a 2-Hz repetition rate. The creation of the source plasma can be described by a simple set of equations which predict optimum source design parameters. The target plasma is also produced by a pulsed discharge. Between the target and source chambers the beam is neutralized by electrons drawn from a set of hot filaments. Currently under study is an unstable wave in a field-free plasma excited when the beam velocity is nearly equal to the target electron thermal velocity (v(beam) approximately 3.5 x 10(7) cm/s, Te = 0.5 eV).  相似文献   

8.
Electron cyclotron resonance (ECR) plasma source at 50 keV, 30 mA proton current has been designed, fabricated, and assembled. Its plasma study has been done. Plasma chamber was excited with 350 W of microwave power at 2450 MHz, along with nitrogen and hydrogen gases. Microwave power was fed to the plasma chamber through waveguide. Plasma density and electron temperature were studied under various operating conditions, such as magnetic field, gas pressure, and transversal distance. Langmuir probe was used for plasma characterization using current-voltage variation. The nitrogen plasma density calculated was approximately 4.5 x 10(11) cm(-3), and electron temperatures of 3-10 eV (cold) and 45-85 eV (hot) were obtained. The total ion beam current of 2.5 mA was extracted, with two-electrode extraction geometry, at 15 keV beam energy. The optimization of the source is under progress to extract 30 mA proton beam current at 50 keV beam energy, using three-electrode extraction geometry. This source will be used as an injector to continuous wave radio frequency quadrupole, a part of 100 MeV proton linac. The required root-mean-square normalized beam emittance is less than 0.2pi mm mrad. This article presents the study of plasma parameters, first beam results, and status of ECR proton source.  相似文献   

9.
A neutral particle analyzer is used to measure the time-resolved energy spectrum of neutral hydrogen leaving a spheromak plasma. A gas cell filled with 10-50 mTorr of helium is used to strip electrons from incoming neutral hydrogen, lowering the minimum detectable energy well below that obtained with thin foils. Effective neutral particle temperature is calculated by fitting a Maxwellian energy distribution to the measured energy spectrum above and below approximately 300 eV. A computational model with approximated profiles of plasma density and neutral density is used with the measured neutral hydrogen flux to estimate the ion temperature. Measurement of the power flux due to neutral hydrogen emitted at the measurement location is extended to the whole plasma surface to estimate the total charge exchange power loss from the plasma. The initial results indicate that the charge exchange power loss represents only 2% of the total input gun power during the sustainment phase of the discharge.  相似文献   

10.
Extensive resources have been allocated to diagnose and minimize lifetime-limiting factors in gridded ion thrusters. While most of this effort has focused on grid erosion, results from wear tests indicate that discharge cathode erosion may also play an important role in limiting the lifetime of ring-cusp ion thrusters proposed for future large flagship missions. The detailed characterization of the near-cathode discharge plasma is essential for mitigating discharge cathode erosion. However, severe difficulty is encountered when attempting to measure internal discharge plasma parameters during thruster operation with conventional probing techniques. These difficulties stem from the high-voltage, high-density discharge cathode plume, which is a hostile environment for probes. A method for interrogating the discharge chamber plasma of a working ion thruster over a two-dimensional grid is demonstrated. The high-speed axial reciprocating probe positioning system is used to minimize thruster perturbation during probe insertion and to reduce heating of the probe. Electrostatic probe measurements from a symmetric double Langmuir probe are presented over a two-dimensional spatial array in the near-discharge cathode assembly region of a 30-cm-diameter ring-cusp ion thruster. Electron temperatures, 2-5 eV, and number density contours, with a maximum of 8 x 10(12) cm(-3) on centerline, are measured. These data provide detailed electron temperature and number density contours which, when combined with plasma potential measurements, may shed light on discharge cathode erosion processes and the effect of thruster operating conditions on erosion rates.  相似文献   

11.
A RF discharge plasma generator with additional electrodes for independent control of plasma potential distribution is proposed. With positive biasing of this ring electrode relative end flanges and longitudinal magnetic field a confinement of fast electrons in the discharge will be improved for reliable triggering of pulsed RF discharge at low gas density and rate of ion generation will be enhanced. In the proposed discharge combination, the electron energy is enhanced by RF field and the fast electron confinement is improved by enhanced positive plasma potential which improves the efficiency of plasma generation significantly. This combination creates a synergetic effect with a significantly improving the plasma generation performance at low gas density. The discharge parameters can be optimized for enhance plasma generation with acceptable electrode sputtering.  相似文献   

12.
New magnetic probe system is installed on the T-10 tokamak to investigate fast-scale magnetic perturbations (f up to 2 MHz). The system is based on vertical and horizontal magnetic probes made by nickel wire in glass enamel isolation (effective area 20-250 cm(2)) separated from the support structures by ceramic spacers (5-10 mm). The probe system is mounted on the top of movable rode allowing positioning along vertical axis close to the plasma boundary at the low field side of the torus. Additional positioning system allows rotation of the probes around the vertical axis on pulse-to-pulse basis. The probes are directly connected to the analog-to-digital converter (ADC) module (acquisition rate 60 MHz) through short (~4 m) coaxial cables. The system allowed identification of the fast-scale magnetic oscillations (0.2-0.5 MHz) during energy quench phase of the disruption instability in plasma with high density. Amplitude of the fast-scale magnetic oscillations decays with distance from the plasma boundary 2-10 times faster than one of the standard magnetohydrodynamic modes.  相似文献   

13.
A method to infer the current density distribution in the current sheath of a plasma focus discharge from a magnetic probe is formulated and then applied to experimental data obtained in a 1.1 kJ device. Distortions on the magnetic probe signal caused by current redistribution and by a time-dependent total discharge current are considered simultaneously, leading to an integral equation for the current density. Two distinct, easy to implement, numerical procedures are given to solve such equation. Experimental results show the coexistence of at least two maxima in the current density structure of a nitrogen sheath.  相似文献   

14.
A long-life, high-current, microwave ion source for an electromagnetic mass separator is described. Ionization takes place due to the 2.45-GHz microwave discharge at a magnetic field intensity which is higher than the electron cyclotron resonance magnetic field. The discharge chamber is a ridged circular waveguide. The discharge region is restricted to a rectangular volume between the ridged electrodes by filling the remaining portions with dielectric. This source operates under low pressure (10(-2)-10(-3) Torr) and with high power efficiency. The incident microwave power is only several hundred watts at maximum output. When PH(3) gas is introduced, the total extracted current is about 40 mA with a 2x40-mm extraction slit. A P(+) ion implantation current of more than 10 mA is obtained by combining the source with a 40-cm radius, 60 degrees deflection magnetic mass separator.  相似文献   

15.
A source of gas ions (argon, oxygen, nitrogen, etc.), the operating principle of which is based on the use of a glow discharge in an electrode system of a wide-aperture hollow cathode and anode in a magnetic field, is described. The exit aperture diameter of the hollow cathode, increased up to a size close to the ion beam diameter (10 cm), ensures the uniform ion emission of the plasma generated in the discharge region near the anode. A decreased angular divergence or increased ultimate ion-beam current density is achieved by a change in the potential drop in the space charge sheath between the plasma and the ion optics. The source generates broad (50 cm2) slightly diverging (ω/2∼3°–5°) ion beams with energies of 300–1000 eV at a beam current density of ∼0.5 mA/cm2.  相似文献   

16.
We have designed and fabricated a low energy plasma calibration facility for testing and calibration of rocket-borne charged-particle detectors and for the investigation of plasma sheath formation in an environment with ionospheric plasma energies, densities, and Debye lengths. We describe the vacuum system and associated plasma source, which was modified from a Naval Research Laboratory design [Bowles et al. Rev. Sci. Instrum. 67, 455 (1996)]. Mechanical and electrical modifications to this cylindrical microwave resonant source are outlined together with a different method of operating the magnetron that achieves a stable discharge. This facility produces unmagnetized plasmas with densities from 1x10(3)/cm(3) to 6x10(5)/cm(3), electron temperatures from 0.1 to 1.7 eV, and plasma potentials from 0.5 to 8 V depending on varying input microwave power and neutral gas flow. For the range of input microwave power explored (350-600 W), the energy density of the plasma remains constant because of an inverse relationship between density and temperature. This relationship allows a wide range of Debye lengths (0.3-8.4 cm) to be investigated, which is ideal for simulating the ionospheric plasma sheaths we explore.  相似文献   

17.
A compact helicon plasma source was developed as a millimeter-sized ion source for ion beam bioengineering. By employing a stacked arrangement of annular-shaped permanent magnets, a uniform axial magnetic flux density up to 2.8 kG was obtained. A cost effective 118 MHz RF generator was built for adjusting forward output power from 0 to 40 W. The load impedance and matching network were then analyzed. A single loop antenna and circuit matching elements were placed on a compact printed circuit board for 50 Ω impedance matching. A plasma density up to 1.1 × 10(12) cm(-3) in the 10 mm diameter tube under the magnetic flux density was achieved with 35 W applied RF power.  相似文献   

18.
The growth of ultrathin films, deposited by laser ablation, crucially depends on the energy of the ablated species. Therefore, a time-of-flight (TOF) spectrometer has been constructed and measurements have been carried out in order to determine the energy distribution of laser-ablated Fe and Pt atoms and ions in the plasma created by nanosecond pulses of a frequency-doubled neodymium doped yttrium aluminum garnet laser. The experiments have been performed in ultrahigh vacuum at relatively low laser power. For measuring the spectra of the neutrals, a cross-beam electron source for postionization and electric as well as magnetic fields for repelling the ions are employed. Nevertheless, measurements of neutral particles are restricted to low plasma densities due to electrostatic shielding within the plasma, leading to an inefficient deflection of charged particles by electrostatic and magnetic fields. Test measurements have been performed by utilizing the TOF spectrometer as a pressure gauge and also by chopping the electron beam, running the TOF spectrometer as a residual gas mass spectrometer. The spectra of the laser-ablated plasmas have shown plasma conditions with a Debye length of approximately 10(-4) m, densities of 10(15)-10(16) m(-3) and ion energies up to 150 eV. Neutral spectra have shown an unexpectedly low fraction of neutrals (10(-3)-10(-4)) and hyperthermal energies up to several 10 eV, possibly contributed by recombination of ions and electrons in the plasma. Even though gas spectra had demonstrated the expected sensitivity of the TOF spectrometer for low-energy neutrals, no thermally evaporated neutral atoms could be found.  相似文献   

19.
The magnetic multipole line-cusp device developed by MacKenzie and associates has been adapted for use as a neutral beam ion source. It has produced high-density, large volume, quiescent, uniform hydrogen plasmas, which makes it a potential candidate for use as a plasma generator for neutral beam injectors. The device is a water-cooled cylindrical copper discharge chamber (25 cm in diameter by 36 cm long) with one end enclosed by a set of extraction grids with a 15-cm-diam multi-aperture pattern. The chamber wall serves as an anode and is surrounded by an external system of rare-earth cobalt magnets arranged in a line-cusp geometry of 12 cusps; plasma is produced by electron emission from a hot cathode assembly. This source has achieved extracted beam currents of 12 A at 18.5 kV, radial plasma density uniformities of +/-5% over a 15-cm diameter, noise levels of less than +/-0.5%, and arc efficiencies (beam current/arc power) of 0.6 A/kW.  相似文献   

20.
An ultrahigh-vacuum (UHV) differentially pumped low-energy (50-3000 eV) ion beam system for the in situ irradiation of specimens in a UHV atom-probe field-ion microscope (FIM) was designed and constructed. The ion beam system consisted of a Finkelstein-type ion source, an Einzel lens, and a magnetic mass analyzer. The ion source was connected to the analyzer chamber by small apertures which resulted in differential pumping between the ion source and the analyzer chamber; during a typical in situ irradiation of a specimen in the atom-probe FIM the total pressure was maintained at approximately 10(-7) Torr. In the case of helium ion irradiation the optimum ion-current density was approximately 0.5 microA cm(-2) for 300-eV He+ ions at the atom-probe FIM specimen. After the completion of a helium ion irradiation the pumpdown time from 5 x 10(-7) to approximately 3 x 10(-10) Torr in the atom-probe FIM chamber was 0.5 h.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号