首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
陈鹏博  李北星  殷实  杨宏天 《硅酸盐通报》2022,41(12):4300-4309
为了探讨同时掺入大掺量再生粗骨料和细骨料制备C40及以上强度等级再生混凝土的可行性,在C45天然骨料混凝土配合比的基础上,采用II类再生粗骨料、I类再生细骨料,以同掺再生粗细骨料质量替代率为25%、50%、75%、100%配制了4组再生混凝土,研究了再生粗细骨料替代率对再生混凝土基本力学性能和耐久性能的影响规律。结果表明:当同掺再生粗细骨料的替代率为25%时,混凝土的力学性能下降很小,替代率为50%、75%的混凝土的抗压强度分别达到C45、C40等级,替代率100%的全再生粗细骨料混凝土的28 d抗压、劈拉、轴压强度和弹性模量等力学性能指标较天然骨料混凝土降低12.0%~23.2%,并达到C35抗压强度等级。增加再生粗细骨料的替代率会降低混凝土的耐久性,但即使是全再生粗细骨料混凝土仍可获得高的耐久性,其抗碳化性能、抗氯离子渗透性、抗冻性能分别达到T-IV、RCM-IV和F300等级,说明在混凝土中同时掺用50%及以上再生粗细骨料配制C40及以上强度等级的再生混凝土是可行的。  相似文献   

2.
High temperature mechanical property data are needed for evaluating fire resistance of structural members. Being a relatively new construction material, there is a lack of temperature-dependent mechanical property data on ultra-high performance concrete (UHPC). To address this knowledge gap, this paper presents results from an experimental study on the effect of temperature on mechanical properties of UHPC. Specimens made of two UHPC mixes: one with only steel fibers (UHPC-S) and the other with hybrid fibers, that is, both steel and polypropylene (UHPC-H), were tested under different heating conditions in 20 to 750°C temperature range. Compressive strength, tensile strength, stress-strain response, and elastic modulus of UHPC were evaluated at various temperatures. Results generated from these property tests on UHPC were compared with property relations specified in design codes for conventional normal strength concrete (NSC) and high strength concrete (HSC). The comparisons show that UHPC experiences faster degradation in compressive strength and elastic modulus as compared to conventional concrete. However, UHPC exhibits slower degradation in tensile strength and ductility at elevated temperatures due to the presence of steel fibers. Data generated from these property tests were utilized to propose relations for expressing the mechanical properties of UHPC as a function of temperature and these relations can be used as input to numerical models for evaluating fire resistance of structures made of UHPC.  相似文献   

3.
In order to evaluate the effect of the conditioning temperature on strength and permeability properties of concrete a series of compressive, indirect tensile and permeability tests were performed on concretes (designed to have 28-day compressive strengths of 40 and 100 N/mm2) conditioned at temperatures of 85 and 105 °C. The results show that, for both the normal- (NSC) and the high-strength concrete (HSC), comparable 28-day test results were obtained from strength tests performed on concrete conditioned at 85 and 105 °C. The permeability results were also somewhat similar for the two conditioning temperatures, although greater differences than previously reported were observed. Conditioning at both 85 and 105 °C was identified as adequate, with the preferred temperature of conditioning being 105 °C.  相似文献   

4.
An experimental investigation on the fracture properties of high-strength concrete (HSC) is reported. Three-point bend beam specimens of size 100×100×500 mm were used as per RILEM-FMC 50 recommendations. The influence of maximum size of coarse aggregate on fracture energy, fracture toughness, and characteristic length of concrete has been studied. The compressive strength of concrete ranged between 40 and 75 MPa. Relatively brittle fracture behavior was observed with the increase in compressive strength. The load-CMOD relationship is linear in the ascending portion and gradually drops off after the peak value in the descending portion. The length of the tail end portion of the softening curve increases as the size of coarse aggregate increases. The fracture energy increases as the maximum size of coarse aggregate and compressive strength of concrete increase. The characteristic length of concrete increases with the maximum size of coarse aggregate and decreases as the compressive strength increases.  相似文献   

5.
This paper presents results of an experimental study on the residual mechanical performance of concrete produced with recycled coarse aggregates, after being subjected to high temperatures. Four different concrete compositions were prepared: a reference concrete made with natural coarse aggregates and three concrete mixes with replacement rates of 20%, 50% and 100% of natural coarse aggregates by recycled concrete coarse aggregates. Specimens were exposed for a period of 1 h to temperatures of 400 °C, 600 °C and 800 °C, after being heated in accordance with ISO 834 time–temperature curve. After cooling down to ambient temperature, the following basic mechanical properties were then evaluated and compared with reference values obtained prior to thermal exposure: (i) compressive strength; (ii) tensile splitting strength; and (iii) elasticity modulus. Results obtained show that there are no significant differences in the thermal response and post-fire mechanical behaviour of concrete made with recycled coarse aggregates, when compared to conventional concrete.  相似文献   

6.
为研究机制砂混凝土单轴应力状态下的力学性能,通过对0%、4%、8%、12%、16%、20%(质量分数)六种石粉含量,C20、C30和C40三类强度等级的机制砂混凝土棱柱体试件进行单轴抗压试验,并与河砂混凝土进行对比,获得了其在单轴受压下的应力-应变全曲线,拟合得到了适用于机制砂混凝土单轴受压的本构方程,结果表明:机制砂混凝土应力-应变曲线变化趋势和河砂混凝土基本相似,在曲线的上升段,机制砂混凝土与河砂混凝土基本重合,但在曲线下降段,机制砂混凝土比较陡峭;随着石粉含量的增加,机制砂混凝土试件的峰值应力和峰值应变都呈现出先增加后减小的趋势,当石粉质量分数为8%时,三种不同强度等级的机制砂混凝土峰值应变均达到最大;机制砂混凝土峰值应力和弹性模量均随着混凝土设计强度等级的提高而增大;基于Sargin模型拟合得到的机制砂混凝土应力-应变全曲线与试验全曲线吻合性较好。  相似文献   

7.
电伴热预养护是一种保证预拌混凝土冬期施工养护温度和强度增长的简单高效的方法。本文采用7 d恒负温(-5 ℃、-10 ℃、-15 ℃)一次冻结转标准养护的试验,研究电伴热预养护不同温度和时间对一种高坍落度C30普通混凝土抗压强度的影响。依据混凝土受冻临界强度的定义,确定基于电伴热预养护条件下的混凝土受冻临界强度值及其合理的预养护时间。结果表明:与标准养护相比,经电伴热高温预养护的混凝土抗压强度均得到了提高,但电伴热预养护温度宜控制在30 ℃,较高的预养护温度下强度发展速率和R-7+28(负温养护7 d再转标养28 d的抗压强度)值反而降低;当预养护温度为30 ℃,硬化温度不低于-15 ℃时,合理的预养护时间在36~48 h之间;恒负温(-5 ℃、-10 ℃、-15 ℃)硬化条件下,采用电伴热预养护的混凝土受冻临界强度的范围是6.6~17.8 MPa,为混凝土立方体抗压强度标准值的22.0%~59.3%。研究旨在比较电伴热预养护制度对普通混凝土力学性能的影响,进而指导相关工程应用。  相似文献   

8.
The mechanical properties and thermal conductivity of concretes including pumice aggregate (PA) exposed to elevated temperature were analyzed by thermal conductivity, compressive strength, flexure strength, dynamic elasticity modulus (DEM) and dry unit weight tests. PA concrete specimens were cast by replacing a varying part of the normal aggregate (0–2 mm) with the PA. All concrete samples were prepared and cured at 23 ± 10C lime saturated water for 28 days. Compressive strength of concretes including PA decreased that reductions were 14, 19, 25 and 34% for 25, 50, 75 and 100% PA, respectively. The maximum thermal conductivity of 1.9382 W/mK was observed with the control samples containing normal aggregate. The tests were carried out by subjecting the samples to a temperature of 0, 100, 200, 300, 400 500, 600 and 700 °C for 3 h, then cooling by air cooling or in water method. The results indicated that all concretes exposed to a temperature of 500 and 700 °C occurred a significant decrease in thermal conductivity, compressive strength, flexure strength and DEM. An artificial neural network (ANN) approach was used to model the thermal and mechanical properties of PA concretes. The predicted values of the ANN were in accordance with the experimental data. The results indicate that the model can predict the concrete properties after elevated temperatures with adequate accuracy. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
Osman Gencel 《火与材料》2012,36(3):217-230
Aggregates typically constitute 70 to 80 wt% of concrete, and therefore their type, size, and structure play an essential role in modifying the properties of concrete. When concrete is used for shielding nuclear applications, temperature is also a key factor. This study investigates the effects of elevated temperatures (25 °C, 200 °C, 400 °C, 600 °C, and 800 °C), heating durations (1, 2, and 3 h), and cooling regimes (air, and water cooling) on mechanical properties of concrete containing different proportions of hematite. A sample of plain concrete was produced for comparison purposes by using river sand, crushed sand, and crushed aggregates. Replacement ratios of 15%, 30%, 45%, and 60% were used for hematite aggregates. The cement content and water–cement ratio were 450 kg/m3 and 0.38, respectively. Slump values of fresh concretes as well as unit weight, compressive strength, flexural strength, splitting tensile strength, and elasticity modulus values of hardened concrete were determined. The addition of hematite into concrete seems to improve its mechanical properties, and hematite concretes have better thermal stability at elevated temperatures than plain concrete does. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
Omer Arioz 《火与材料》2009,33(5):211-222
Concrete as a construction material is likely exposed to high temperatures during fire. The retained properties of concrete after such exposures are still of great importance in terms of the serviceability of structures. This paper presents the effects of high temperatures on the physical, mechanical, and microstructural properties of concrete. Specimens with different sizes were exposed to high temperatures ranging from 200 to 1200°C. The compressive strength, splitting tensile strength, ultrasonic pulse velocity, and rebound numbers of the specimens were determined. The microstructures of the specimens were examined by scanning electron microscope (SEM) analyses. The test results indicated that the retained compressive strength of concrete considerably decreased with increase in temperature. The effect of specimen size on the retained compressive strength was not pronounced. The retained splitting tensile strength of concrete remarkably reduced as the temperature was increased. The specimen size played an important role on the retained splitting tensile strength of concrete up to 400°C. The test results revealed that ultrasonic pulse velocity (UPV) test can be successfully used in order to check the uniformity of fire‐damaged structures. The rebound numbers decreased with increase in exposure temperature. SEM studies on specimens exposed to 800°C revealed significant changes in the microstructure of the concrete. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
This paper presents an experimental study on the residual mechanical properties of concrete with recycled ceramic coarse aggregate (RCCA) after exposure to elevated temperatures. Four concrete mixes were produced: a control concrete and three concrete mixes with replacement ratios of 20, 50 and 100% of natural aggregate (NA) by RCCA. The specimens were subjected to temperatures of 200, 400 and 600°C, for a period of 60 min. After cooling down to room temperature, the following concrete properties were evaluated: (i) compressive strength; (ii) splitting tensile strength; (iii) modulus of elasticity; (iv) ultrasonic pulse velocity (UPV); and (v) water absorption by immersion. At ambient temperature, as expected, the replacement of NA by RCCA resulted in a performance reduction of concrete. After exposure to elevated temperature, in general, the results obtained indicated an improvement of the residual relative mechanical properties of the mixes with RCCA, particularly after exposure to 400 and 600°C. However, exposure to the highest temperature (600°C) tended to cause spalling in concrete mixes containing RCCA. Significant linear correlations were observed between the residual compressive strength of all concrete mixes and both the UPV and the water absorption by immersion. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

12.
Concrete normally suffers from low stiffness and poor strain capacity after exposure to high temperatures. This study focused on evaluating the effect of recycled glass (RG) on the residual mechanical properties of self‐compacting glass concrete (SCGC) after exposure to elevated temperatures. RG was used to replace fine aggregate at ratios of 0%, 25%, 50%, 75% and 100% by weight. The residual properties were evaluated according to compressive strength, elastic modulus, stress–strain behaviour and strain at pre‐load and peak stress. A comparative assessment of different curing conditions on the SCGC was also conducted. The results showed that there were significant decreases in compressive strength, elastic modulus and concrete stiffness of the concrete with increasing temperature. The use of RG had little influence on the elastic modulus at ambient temperature; however, after exposure to 800°C, the mechanical properties of the concrete were greatly enhanced by incorporating RG. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
The mechanical properties of self-compacting concrete (SCC) are well understood. But there are no scientific investigations available on the influence of a heat treatment on the properties of SCC. To evaluate the influence on the compressive strength, SCCs as powder type, combination type and viscosity-agent type in the strength classes between C20/25 and C70/85 were designed and exposed to heat treatment with different maximum temperatures. It has been found that there is an influence of the composition of the concrete, especially the (w/c)eq ratio, on the compressive strength after heat treatment. The reason for the substantial loss of strength in some cases compared to the strength of the concrete, which was stored under standard conditions, is a change of the pore size distribution. An empirical formula is presented to calculate the influence of the heat treatment on the compressive strength of the SCCs.  相似文献   

14.
Residual strength tests are commonly used to characterize the high-temperature mechanical properties of concrete materials. In these tests, the specimens are heated to a target temperature in a furnace and then cooled down to room temperature, followed by mechanical testing at room temperature. This research investigates the influence of the cooling method on the residual strength of Strain Hardening Cementitious Composites (SHCC) after exposure to 400°C and 600°C. Two types of cooling methods — furnace-cooling (within a closed furnace) and water-cooling (immersed in a water tank) — were adopted. Four different SHCC previously investigated by the authors for high-temperature residual mechanical and bond behavior with steel were studied. Two different specimen sizes were tested under uniaxial compression and flexure to characterize the residual compressive strength and modulus of rupture. The effect of the cooling method was prominent for the normalized residual modulus of rupture at 400°C, but not at 600°C. The cooling method had no effect on the normalized residual compressive strength of any material at either of the two temperatures, except one of the SHCC (PVA-SC) at 400°C. Specimen size also had no effect on the normalized residual compressive strength and modulus of rupture irrespective of the cooling method.  相似文献   

15.
The residual properties of concrete subjected to elevated temperature are of importance to assess the stability of the structure. This paper investigates the performance of concrete containing white ware ceramic sand exposed to elevated temperature. Concrete mixes containing 0%, 50%, and 100% ceramic sand were prepared. The specimen were exposed to elevated temperatures of 200°C, 500°C, and 800°C for a duration of 60 minutes. Their residual mechanical properties (compressive strength, split tensile strength), ultra sonic pulse velocity, and mass change for different cooling regimes were investigated and compared among specimen. The results showed that incorporation of ceramic sand in concrete mixes improved the resistance against elevated temperature of hardened concrete.  相似文献   

16.
This paper presents an experimental study on the properties of self-compacting concrete (SCC) subjected to high temperature. Two SCC mixtures and one vibrated concrete mixture were tested. These concrete mixtures come from the French National Project B@P. The specimens of each concrete mixture were heated at a rate of 1 °C/min up to different temperatures (150, 300, 450 and 600 °C). In order to ensure a uniform temperature throughout the specimens, the temperature was held constant at the maximum temperature for 1 h before cooling. Mechanical properties at ambient temperature and residual mechanical properties after heating have already been determined. In this paper, the physicochemical properties and the microstuctural characteristics are presented. Thermogravimetric analysis, thermodifferential analysis, X-ray diffraction and SEM observations were used. The aim of these studies was in particular to explain the observed residual compressive strength increase between 150 and 300 °C.  相似文献   

17.
This paper presents the effect of temperature on thermal and mechanical properties of self-consolidating concrete (SCC) and fiber reinforced SCC (FRSCC). For thermal properties specific heat, thermal conductivity, and thermal expansion were measured, whereas for mechanical properties compressive strength, tensile strength and elastic modulus were measured in the temperature range of 20–800 °C. Four SCC mixes, plain SCC, steel, polypropylene, and hybrid fiber reinforced SCC were considered in the test program. Data from mechanical property tests show that the presence of steel fibers enhances high temperature splitting tensile strength and elastic modulus of SCC. Also the thermal expansion of FRSCC is slightly higher than that of SCC in 20–1000 °C range. Data generated from these tests was utilized to develop simplified relations for expressing thermal and mechanical properties of SCC and FRSCC as a function of temperature.  相似文献   

18.
试验研究了干寒大温差环境养护下的混凝土开裂过程、抗压强度及28 d龄期的孔径分布情况,分析了混凝土的初始开裂面积、气孔结构与抗压强度之间的关系,并与标准养护下的试验结果进行了对比分析.结果表明:在干寒大温差的养护条件下,混凝土的抗裂性能和力学性能更差,具体表现为初裂时间更短、初裂长度、初裂宽度更大、裂缝总条数更多;混凝土同龄期的抗压强度也较标准养护下要小,并与混凝土的初始开裂面积存在一定的相关性;孔径分布较标准养护下有一定的差异,主要表现为小孔径的孔更少,大孔径的孔更多,孔径分布朝着大孔径的方向移动;除此之外,水胶比也对混凝土的抗裂性、抗压强度和孔径分布有影响.  相似文献   

19.
Recent developments in the fabrication of hollow spheres have allowed our group to prepare a new type of macroporous ceramics: hollow sphere ceramics (HSCs). Alumina hollow spheres were first produced by centrifugal spray‐drying of particle‐stabilized foam slurry. The obtained hollow spheres were sintered together to form HSC at high temperatures. The effect of the sintering temperature on the linear shrinkage, porosity and compressive strength of HSC samples was investigated. When the sintering temperature was increased from 1400°C to 1600°C, the samples shrunk increasingly and the porosity decreased from 59% to 42%, which lead to an increase in the strength of the alumina foams from 6.9 (at 1400°C) to 100.0 MPa (at 1550°C). The mechanical strength of the HSC highly depends on the contact area between the hollow spheres, which could be increased by increasing the sintering temperature, decreasing the size of hollow spheres or by slurry infiltration.  相似文献   

20.
High strength concrete has been used in situations where it may be exposed to elevated temperatures. Numerous authors have shown the significant contribution of polypropylene fibre to the spalling resistance of high strength concrete. This investigation develops some important data on the mechanical properties and microstructure of high strength concrete incorporating polypropylene fibre exposed to elevated temperature up to 200 °C. When polypropylene fibre high strength concrete is heated up to 170 °C, fibres readily melt and volatilise, creating additional porosity and small channels in the concrete. DSC and TG analysis showed the temperature ranges of the decomposition reactions in the high strength concrete. SEM analysis showed supplementary pores and small channels created in the concrete due to fibre melting. Mechanical tests showed small changes in compressive strength, modulus of elasticity and splitting tensile strength that could be due to polypropylene fibre melting.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏