首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
To our knowledge we present the first experiments with a fully reflective external-cavity quantum-cascade laser system at mid-infrared wavelengths for use as a local oscillator in a heterodyne receiver. The performance of the presented setup was investigated using absorption spectroscopy as well as heterodyne techniques. Tunability over approximately 30 cm(-1) at 1130 cm(-1) was demonstrated using a grating spectrometer. A continuous tuning range of 0.28 cm(-1) was verified by observing the spectra of an internally coupled confocal Fabry-Pérot interferometer and the absorption lines of gas phase SO(2). In a second step the output from the system was used as a local oscillator signal for a heterodyne setup. We show that spectral stability and side mode suppression are excellent and that a compact external-cavity quantum-cascade laser system is well suited to be used as a local oscillator in infrared heterodyne spectrometers.  相似文献   

2.
Kuyanov KE  Momose T  Vilesov AF 《Applied optics》2004,43(32):6023-6029
We developed a pulsed, continuously tunable laboratory laser source for the mid-infrared spectral range of 4.4-8 microm, which is characterized by the spectral linewidth of 0.4 cm(-1). The device is based on the stimulated backward Raman scattering in solid para-hydrogen at T = 4 K. It is pumped by a focused beam obtained from a commercial near-infrared optical parametric oscillator with output energy of approximately 20 mJ (7-ns pulse). Output energies range from 1.7 mJ at 4.4 microm to 120 microJ at 8 microm, which correspond to quantum efficiencies of 0.53 and 0.08, respectively. Spectra of NO, H2O, and CH4 molecules in the mid-infrared were recorded. The operation of the Raman cell pumped with 532-nm radiation was also studied.  相似文献   

3.
Geng J  Wang Q  Jiang S 《Applied optics》2012,51(7):834-840
Broadband mid-infrared supercontinuum pulses were generated directly from a short piece of active fiber in a single-mode Tm-doped fiber amplifier. The broadband mid-infrared pulses have an extremely high spectral flatness with ~600 nm FWHM bandwidth (from 1.9 μm to 2.5 μm), >15 kW peak power, and >20 GW/cm(2) laser peak intensity. This new approach exhibits a significantly different physical mechanism from other supercontinuum generation demonstrations in the literature, in which usually a piece of passive fiber was used for nonlinear spectral broadening. The physical mechanism for the broadband mid-infrared supercontinuum generation in this approach has been attributed to a combined effect of two superradiative processes of Tm(3+) ions (i.e., the (3)F(4)-(3)H(6) transition covering the 1.8~2.1 μm spectral region and the (3)H(4)-(3)H(5) transition covering the 2.2~2.5 μm spectral region), and also nonlinear optical processes as well in the Tm-doped gain fiber. The spectra of the mid-infrared supercontinuum pulses were further broadened in a 2 m chalcogenide fiber with 20 dB bandwidth ~1100 nm and a 3 m fluoride fiber with 20 dB bandwidth ~2600 nm.  相似文献   

4.
The ex vivo removal of urea during hemodialysis treatments is monitored in real time with a noninvasive near-infrared spectrometer. The spectrometer uses a temperature-controlled acousto optical tunable filter (AOFT) in conjunction with a thermoelectrically cooled extended wavelength InGaAs detector to provide spectra with a 20 cm(-1) resolution over the combination region (4000-5000 cm(-1)) of the near-infrared spectrum. Spectra are signal averaged over 15 seconds to provide root mean square noise levels of 24 micro-absorbance units for 100% lines generated over the 4600-4500 cm(-1) spectral range. Combination spectra of the spent dialysate stream are collected in real-time as a portion of this stream passes through a sample holder constructed from a 1.1 mm inner diameter tube of Teflon. Real-time spectra are collected during 17 individual dialysis sessions over a period of 10 days. Reference samples were extracted periodically during each session to generate 87 unique samples with corresponding reference concentrations for urea, glucose, lactate, and creatinine. A series of calibration models are generated for urea by using the partial least squares (PLS) algorithm and each model is optimized in terms of number of factors and spectral range. The best calibration model gives a standard error of prediction (SEP) of 0.30 mM based on a random splitting of spectra generated from all 87 reference samples collected across the 17 dialysis sessions. PLS models were also developed by using spectra collected in early sessions to predict urea concentrations from spectra collected in subsequent sessions. SEP values for these prospective models range from 0.37 mM to 0.52 mM. Although higher than when spectra are pooled from all 17 sessions, these prospective SEP values are acceptable for monitoring the hemodialysis process. Selectivity for urea is demonstrated and the selectivity properties of the PLS calibration models are characterized with a pure component selectivity analysis.  相似文献   

5.
Absorption spectra of aqueous solution of 'chaotropes' (structure maker) and 'kosmotropes' (structure breaker) have been recorded in the mid-infrared (MIR) and terahertz (THz) spectral region. A different impact of the two groups of solutes on the absorption spectrum of water was found in the recorded THz spectra. A concentration-dependent increased absorption across the investigated THz spectral region (0.04-2 THz, 1.3-66 cm(-1), respectively) has been recorded for all studied chaotropic solutions, whereas the opposite has been obtained for kosmotrope containing solutions. In the case of ionic solutes a further increase in absorption towards higher frequencies was measured. The distinction between chaotrope and kosmotrope solutes was, as expected, also possible in the MIR spectral region. Depending on the structure-forming effect of the solute the OH stretch vibration of the water (around 3400 cm(-1)) was slightly shifted. A red shift has been observed for solution of kosmotropes, whereas a blue shift was observed in the case of solutions containing chaotropes. Compared to the MIR spectral region the structure influencing effect of solutes can be more efficiently studied in the THz spectral region, which provides information from interactions between neighboring water molecules.  相似文献   

6.
We measure the diffuse reflection spectrum of solid samples such as explosives (TNT, RDX, PETN), fertilizers (ammonium nitrate, urea), and paints (automotive and military grade) at a stand-off distance of 5 m using a mid-infrared supercontinuum light source with 3.9 W average output power. The output spectrum extends from 750-4300 nm, and it is generated by nonlinear spectral broadening in a 9 m long fluoride fiber pumped by high peak power pulses from a dual-stage erbium-ytterbium fiber amplifier operating at 1543 nm. The samples are distinguished using unique spectral signatures that are attributed to the molecular vibrations of the constituents. Signal-to-noise ratio (SNR) calculations demonstrate the feasibility of increasing the stand-off distance from 5 to ~150 m, with a corresponding drop in SNR from 28 to 10 dB.  相似文献   

7.
We report the first vibrational circular dichroism (VCD) spectra with continuous coverage from 800 cm(-1) in the mid-infrared (MIR) region to 10 000 cm(-1) in the near-infrared (NIR) region. This coverage is illustrated with MIR and NIR absorbance and VCD spectra of 2,2-dimethyl-dioxolane-4-methanol (DDM), alpha-pinene, and camphor that serve as calibration samples over this entire region. Commercially available, dual-source Fourier transform (FT) MIR and NIR VCD spectrometers were equipped with appropriate light sources, optics, and detectors, and were modified for dual-polarization-modulation (DPM) operation. The combination of liquid-nitrogen- and thermoelectric-cooled HgCdTe (MCT) detectors, as well as InGaAs and Germanium (Ge) detectors operating at room temperature, permitted collection of the desired absorbance and VCD spectra across the range of vibrational fundamental, combination band, and overtone frequencies. The spectra of DDM and alpha-pinene were measured as neat liquids and recorded for both enantiomers in the various spectral regions. Spectra for camphor were all measured in CCl(4) solution at a concentration of 0.6 M, except for the carbonyl-stretching region, where a more dilute concentration was used. The typical anisotropy ratios (g) of the three molecules were estimated with respect to their strongest VCD bands in each spectral region. It was found that for all three molecules in the spectral regions above 2000 cm(-1), anisotropy ratios are approximately the same order (10(-5)) of magnitude. However, in the MIR region, the typical anisotropy ratios are significantly different for the three molecules. This study demonstrates that with modern FT-VCD spectrometers modified for DPM operation, VCD spectra can be measured continuously across a wide spectral range from the MIR to nearly the visible region with an unsurpassed combination of signal-to-noise ratio and spectral resolution.  相似文献   

8.
Wine tannins are fundamental to the determination of wine quality. However, the chemical and sensorial analysis of these compounds is not straightforward and a simple and rapid technique is necessary. We analyzed the mid-infrared spectra of white, red, and model wines spiked with known amounts of skin or seed tannins, collected using Fourier transform mid-infrared (FT-MIR) transmission spectroscopy (400-4000 cm(-1)). The spectral data were classified according to their tannin source, skin or seed, and tannin concentration by means of discriminant analysis (DA) and soft independent modeling of class analogy (SIMCA) to obtain a probabilistic classification. Wines were also classified sensorially by a trained panel and compared with FT-MIR. SIMCA models gave the most accurate classification (over 97%) and prediction (over 60%) among the wine samples. The prediction was increased (over 73%) using the leave-one-out cross-validation technique. Sensory classification of the wines was less accurate than that obtained with FT-MIR and SIMCA. Overall, these results show the potential of FT-MIR spectroscopy, in combination with adequate statistical tools, to discriminate wines with different tannin levels.  相似文献   

9.
The aim of this study was to demonstrate that mid-infrared spectroscopy is able to quantify glucose in a serum matrix with sample volumes well below 1 muL. For this, we applied mid-infrared attenuated total reflectance (ATR) or transmission-based spectroscopic methods to glucose quantification in microsamples of dry-film sera, either undiluted or diluted 10 times in distilled water. The sample series spanned physiological glucose concentrations between 50 and 600 mg/dL and volumes of 80, 8, and 1 nL. Calibration was carried out using multivariate partial least-squares (PLS) modeling with spectral data between 1180 and 940 cm(-1). Best performance was achieved in the ATR experiments. For raw ATR spectra, the optimum standard error of prediction (SEP) of 13.3 mg/dL was obtained for the 8 nL sample series with subsequent 10-fold dilution. With respect to the coefficient of variation of the glucose assay, CV(pred), we obtained a value of 3% for the 80 nL volume samples with spectral preprocessing using matrix protein absorption bands as an internal standard, 4% for the 8 nL samples, and 6% for the 1 nL samples with raw data. Spectral standardization resulted in significant improvement, especially for the 80 nL volume sample series. By contrast, the accuracy of the glucose assay for the 1 nL sample volume series could not be improved either by internal standardization or by considering the dry film areas for normalization, which we attribute to varying topographies of the dry films.  相似文献   

10.
The development of a hollow core waveguide (HWG) gas sensor in combination with a fast and compact near-infrared (NIR) spectrometer is presented. The spectrometer operates in the spectral range of 1200-1400 nm and may thus be applied for the detection of gas-phase analytes providing NIR absorptions in that spectral window such as, e.g., methane. Since mid-infrared spectroscopy in combination with HWGs has already been successfully demonstrated for probing hydrocarbons in the gas phase, the present study investigates the achievable sensitivity in the NIR spectral regime. Methane has been selected as an exemplary analyte due to the fact that it shows strong absorption features in the mid-infrared (mid-IR) fingerprint area, but also overtone bands in the NIR. Since the HWG simultaneously serves as a miniaturized absorption gas cell and as an optical waveguide for NIR radiation, a compact yet optical and cost-efficient sensor device was established providing an interesting alternative in target sensing for mid-IR devices. The achieved limit of detection (LOD) was 5.7% (vol./vol.) methane for a 9.5 cm long HWG, 1.6% (vol./vol.) methane for a 39.1 cm long HWG, and 1.3% (vol./vol.) methane for a setup using a 77.4 cm long HWG, which provides the most practical HWG dimensions among the three investigated setups. Limit of quantitation (LOQ) values were calculated at 20.1% (vol./vol.) methane, 8.7% (vol./vol.) methane, and 5.6% (vol./vol.) methane, respectively.  相似文献   

11.
Molar absorptivities are measured for water, glucose, alanine, ascorbate, lactate, triacetin, and urea in the near-infrared spectral region at 37 degrees C. Values are based on the Beer-Lambert law and cover the first overtone (1550-1850 nm; 6450-5400 cm(-1)) and combination (2000-2500 nm; 4000-5000 cm(-1)) spectral windows through aqueous media. Accurate calculations demand accounting for the impact of water displacement upon dissolution of solute. In this regard, water displacement coefficients are measured and reported for each solute. First overtone absorptivities range from 2 to 7 x 10(-5) mM(-1)mm(-1) for all solutes except urea, for which absorptivity values are below 0.5 x 10(-5) mM(-1) mm(-1) across this spectral range. Molar absorptivities over the combination spectral region range from 0.8 to 3.2 x 10(-4) mM(-1) mm(-1), which is a factor of four to five greater than the first overtone absorptivities. Accuracy of the measured values is assessed by comparing calculated or modeled spectra with spectra measured from standard solutions. This comparison reveals accurately modeled spectra in terms of magnitude and position of solute absorption bands. Both actual and modeled spectra from glucose solutions reveal positive and negative absorbance values depending on the measurement wavelength. It is shown that the net absorbance of light is controlled by the magnitude of the absorptivity of glucose compared to the product of the absorptivity of water and the water displacement coefficient for glucose.  相似文献   

12.
Partial least squares calibration models are compared for the measurement of glucose, lactate, urea, ascorbate, triacetin, and alanine in aqueous solutions from single-beam spectra collected over the first overtone (6500-5500 cm(-1)) and the combination (5000-4000 cm(-1)) regions of the near-infrared spectrum. Spectra are collected under two sets of conditions with one designed for combination spectra and the other designed for first overtone spectra. As part of the optimization of conditions, an exponential function is presented that accurately characterizes the strong dependency between spectral quality and sample thickness. Sample thickness set for the first overtone and combination spectra are 7.5 and 1.5 mm, respectively. Independent calibration models are established for each solute from both combination and first overtone spectra. Direct comparison reveals superior performance by models generated from combination spectra, particularly for glucose and urea. Standard error of prediction (SEP) values are 1.12 and 0.45 mM for glucose models generated from first overtone and combination spectra, respectively. SEP values for urea are 7.33 and 0.10 mM for first overtone and combination spectra, respectively. Such high SEP values for urea with first overtone spectra correspond to an inability to quantify urea from these spectra because of a lack urea-specific molecular absorption features in this spectral region. Net analyte signal (NAS) is used to quantify the degree of selectivity provided within the first overtone and combination spectral regions. The superior selectivity of combination spectra is confirmed by comparing the length of the NAS vectors for each matrix component.  相似文献   

13.
Linker R 《Applied spectroscopy》2004,58(11):1277-1281
This paper investigates the possibility of determining nitrate concentration in soil pastes using spectral absorbance at several fixed wavebands. A three-step procedure for determining the most appropriate wavebands, as well as their width, is described. This procedure is applied to a dataset that includes eleven soils with various nitrate concentrations ranging from 0 to approximately 150 mg [N]/kg [dry soil]. The results show that nitrate concentration can be determined quite acceptably using only four 12 cm(-1) wide wavebands, centered at 1280, 1330, 1379, and 1430 cm(-1). The prediction errors range from approximately 1.5 to 14.0 mg [N]/kg [dry soil], depending on soil composition and moisture content, with the lighter and more vulnerable (pollution-wise) soils having errors inferior to 10 mg [N]/kg [dry soil]. These results are similar to results obtained by applying partial least square to the 'continuous' spectrum, and indicate that the development of a soil nitrate attenuated total reflectance (ATR) sensor based on a few fixed mid-infrared (MIR) wavebands could be considered.  相似文献   

14.
Fourier transform infrared (FT-IR) spectra of human spermatozoa and seminal plasma were recorded and analyzed. The procedure that was established for sample preparation enabled acquisition of reproducible spectra. The parameter I(1087)/I(966) for controlling spectra reproducibility was defined. The assignment of bands was carried out using an empirical approach and the origin of the "sperm specific doublet", the bands at 968 cm(-1) and 981 cm(-1), was determined. The principal component regression (PCR) algorithm was used to define the specific spectral regions correlating to characteristics of spermatozoa, such as concentration, straight-line velocity (VSL), and beat cross frequency (BCF). Then, simple spectral parameters, such as band intensities and band ratios, were tested to determine which one best correlates to characteristics of spermatozoa. The region of the amide I band, between 1700 cm(-1) and 1590 cm(-1), was defined as a specific spectral region that correlates to the concentration of spermatozoa. The parameter that gave the linear dependence to the concentration of spermatozoa was the intensity of the amide I band. For VSL, the bands between 1119 cm(-1) and 943 cm(-1) were defined as the specific spectral region. The relative amount of nucleic acids with respect to proteins showed linear dependence on the straight-line velocity of spermatozoa. BCF showed the best correlation to the bands between 3678 cm(-1) and 2749 cm(-1), which largely represent lipids and proteins. These results suggest that FT-IR spectroscopy can serve as an adjunct to conventional histopathology studies.  相似文献   

15.
Fourier transform infrared (FTIR) microspectroscopy is a powerful technique for label-free chemical imaging that has supplied important chemical information about heterogeneous samples for many problems across a variety of disciplines. State-of-the-art synchrotron based infrared (IR) microspectrometers can yield high-resolution images, but are truly diffraction limited for only a small spectral range. Furthermore, a fundamental trade-off exists between the number of pixels, acquisition time and the signal-to-noise ratio, limiting the applicability of the technique. The recently commissioned infrared synchrotron beamline, infrared environmental imaging (IRENI), overcomes this trade off and delivers 4096-pixel diffraction limited IR images with high signal-to-noise ratio in under a minute. The spatial oversampling for all mid-IR wavelengths makes the IRENI data ideal for spatial image restoration techniques. Here, we measured and fitted wavelength-dependent point-spread-functions (PSFs) at IRENI for a 74× objective between the sample plane and detector. Noise-free wavelength-dependent theoretical PSFs are deconvoluted from images generated from narrow bandwidths (4 cm(-1)) over the entire mid-infrared range (4000-900 cm(-1)). The stack of restored images is used to reconstruct the spectra. Restored images of metallic test samples with features that are 2.5 μm and smaller are clearly improved in comparison to the raw data images for frequencies above 2000 cm(-1). Importantly, these spatial image restoration methods also work for samples with vibrational bands in the recorded mid-IR fingerprint region (900-1800 cm(-1)). Improved signal-to-noise spectra are reconstructed from the restored images as demonstrated for a mixture of spherical polystyrene beads in a polyurethane matrix. Finally, a freshly thawed retina tissue section is used to demonstrate the success of deconvolution achievable with a heterogeneous, irregularly shaped, biologically relevant sample with distinguishing spectroscopic features across the entire mid-IR spectral range.  相似文献   

16.
Fourier transform infrared transmission (FT-IR) and attenuated total reflection (ATR) spectra of water-ethanol mixtures are recorded and reconstructed thanks to a causal dispersion analysis technique. As expected, the Beer's law technique is an empirical approximate method that cannot account for complex spectral features. On the other hand, a rigorous analysis performed by using the theoretical optical paths for both experimental techniques and Gaussian dispersion analysis (GDA) allows the dielectric functions of the pure liquids to be calculated. Simulations of the whole mid-infrared spectra in the range 500-4000 cm(-1) match the experimental data very well, whatever the water-ethanol mixtures. This method is a powerful tool to quantify such model mixtures and more generally could be the first step toward software for assistance to the FT-IR spectrum analysis.  相似文献   

17.
Shahnazi K 《Applied optics》1998,37(12):2502-2504
The unblended ozone line at 1044.533 cm(-1) was acquired by using the frequency modulation technique. A tunable CO(2) sideband laser with a GaAs waveguide modulator with a tuning bandwidth of 20 GHz in the mid-infrared region was used for this sideband at 1-MHz frequency with a peak-to-peak amplitude of 1 V was imposed on the first tunable sideband. The signal was passed through a 1-m cell and collected with an EG&G detector. The signal-to-noise ratio obtained wasapproximately 100:1.  相似文献   

18.
Steele HM  Eldering A  Sen B  Toon GC  Mills FP  Kahn BH 《Applied optics》2003,42(12):2140-2154
Infrared transmission spectra were recorded by the Jet Propulsion Laboratory MkIV interferometer during flights aboard the NASA DC-8 aircraft as part of the Airborne Arctic Stratospheric Expedition II (AASE II) mission in the early months of 1992. In our research, we infer the properties of the stratospheric aerosols from these spectra. The instrument employs two different detectors, a HgCdTe photoconductor for 650-1850 cm(-1) and an InSb photodiode for 1850-5650 cm(-1), to simultaneously record the solar intensity throughout the mid-infrared. These spectra have been used to retrieve the concentrations of a large number of gases, including chlorofluorocarbons, NOy species, O3, and ozone-depleting gases. We demonstrate how the residual continua spectra, obtained after accounting for the absorbing gases, can be used to obtain information about the stratospheric aerosols. Infrared extinction spectra are calculated for a range of modeled aerosol size distributions and compositions with Mie theory and fitted to the measured residual spectra. By varying the size distribution parameters and sulfate weight percent, we obtain the microphysical properties of the aerosols that best fit the observations. The effective radius of the aerosols is found to be between 0.4 and 0.6 microm, consistent with that derived from a large number of instruments in this post-Pinatubo period. We demonstrate how different parts of the spectral range can be used to constrain the range of possible values of this size parameter and show how the broad spectral bandpass of the MkIV instrument presents a great advantage for retrieval ofboth aerosol size a nd composition over instruments with a more limited spectral range. The aerosol composition that provides the best fit to the measured spectra is a 70-75% sulfuric acid solution, in good agreement with that obtained from thermodynamic considerations.  相似文献   

19.
Dynamic oscillatory experiments and front-face synchronous fluorescence spectroscopy and mid-infrared (mid-IR) spectroscopy have been used to investigate structure evolution, at the macroscopic and molecular levels, during milk acidification kinetics. The studies were performed using skim milk, at two different temperatures (30 °C and 40 °C), to which was added glucono-δ-lactone (GDL) to generate different structural changes in casein micelles and gels. Synchronous fluorescence spectra were recorded in the 250-500 nm excitation wavelength range using an offset of 80 nm between the excitation and emission monochromators for each system during the 300 min acidification kinetics. The change in the fluorescence intensity at 281 nm reflects the pH-induced physicochemical changes of casein micelles and, in particular, structural changes in the micelles in the pH range 5.5-5.0. Regarding mid-infrared spectroscopy, the region located between 1700 and 1500 cm(-1), corresponding to the amide I and II bands, and the 1500-900 cm(-1) region, called the fingerprint region, were considered for the characterization of milk coagulation kinetics. Changes in the absorbance at 1063 cm(-1) as a function of pH for kinetics recorded at 30 °C and 40 °C reflected pH-induced phosphate dissolution in the pH range 5.5-5.0. Compared to rheometry, which reveals microstructure changes only in the gel state, spectroscopic methods make it possible to monitor molecular structure changes in micelles throughout the acidification processes.  相似文献   

20.
Measurements of mid-infrared (MIR) absorption spectra of water and heavy water were carried out by fiber-optic evanescent wave spectroscopy, using silver halide (AgClBr) infrared fibers. Such measurements were performed for the first time on one sample, during the solid-liquid phase transition. From the variation of the spectra with temperature we found a new isosbestic point (at 3280 cm(-1) for H(2)O or at 2475 cm(-1) for D(2)O) and we identified five components of the O-H (O-D) stretch band. These phenomena have provided new information about the molecular structure of water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号