共查询到20条相似文献,搜索用时 31 毫秒
1.
陈坤永 《广东输电与变电技术》2007,(4):47-49
针对电缆故障查找相对困难的特点,介绍了两种实用的电缆故障查找方法,通过对两种方法的灵活运用,可有效的缩短故障处理时间,尽快恢复供电。 相似文献
2.
3.
针对树形配电线路特点,建立分布参数电路模型,利用故障后线路起始端的电压、电流相量,提出了树形配电线路单相断线兼接地故障测距的新算法,大量计算机仿真表明该算法有效。 相似文献
4.
根据交-交变频电源的控制特性,提出了新颖的多CPU计算机控制系统结构。该结构集自诊断、容错、多CPU控制技术于一体,不但提高了计算机控制系统的可靠性,并可实现较为复杂的系统控制策略。 相似文献
5.
我国110kV及以上电压等级MOA的发展、事故分析及其预防 总被引:9,自引:1,他引:9
本文简要介绍了我国MOA的发展情况,并通过对MOA的运行调查和质量监测工作,总结分析了MOA的事故原因,提出了预防事故的措施。 相似文献
6.
7.
为消除负荷电流和线路模型不准确给双端量故障测距带来的影响 ,本文提出一种基于分布参数线路模型的精确测距算法。算法以均匀传输线的波动方程 (长线方程 )为基础 ,利用线路两端电压、电流的正序故障分量以及线路正序参数直接计算故障距离。算法无需故障类型判别 ,不受系统阻抗、故障电阻、负荷电流以及分布电容的影响。基于EMTP的数字仿真结果验证了该算法的正确性和高精度 相似文献
8.
This paper deals with fault tolerant shunt three-phase three-wire active filter topologies for which reliability is very important in industry applications. The determination of the optimal reconfiguration structure among various ones with or without redundant components is discussed based on reliability criteria. First, the reconfiguration of the inverter is detailed and a fast fault diagnosis method for power semi-conductor or driver fault detection and compensation is presented. This method avoids false fault detection due to power semi-conductors switching. The control architecture and algorithm are studied and a fault tolerant control strategy is considered. Simulation results in open and short circuit cases validate the theoretical study. Finally, the reliability of the studied three-phase three-wire filter shunt active topologies is analyzed to determine the optimal one. 相似文献
9.
10.
11.
罐区是重大工业危险源,因此罐区的故障检测和诊断非常重要文中根据讴的特点对故障检测与诊断方法进行分析,比较和研究,并针对化工行业的一个具体罐区确定其故障检测和诊断方法。 相似文献
12.
As it is crucial to protect the transmission line from inevitable faults consequences, intelligent scheme must be employed for immediate fault detection and classification. The application of Artificial Neural Network (ANN) to detect the fault, identify it’s section, and classify the fault on transmission lines with improved zone reach setting is presented in this article. The fundamental voltage and current magnitudes obtained through Discrete Fourier Transform (DFT) are specified as the inputs to the ANN. The relay is placed at section-2 which is the prime section to be protected. The ANN was trained and tested using diverse fault datasets; obtained from the simulation of different fault scenarios like different types of fault at varying fault inception angles, fault locations and fault resistances in a 400 kV, 216 km power transmission network of CSEB between Korba-Bhilai of Chhattisgarh state using MATLAB. The simulation outcomes illustrated that the entire shunt faults including forward and reverse fault, it s section and phase can be accurately identified within a half cycle time. The advantage of this scheme is to provide a major protection up to 99.5% of total line length using single end data and furthermore backup protection to the forward and reverse line sections. This routine protection system is properly discriminatory, rapid, robust, enormously reliable and incredibly responsive to isolate targeted fault. 相似文献
13.
提出了一种单相接地故障定位的新方法,该方法适用于不同的中性点连接方式,在理论上不受短路点过渡电阻的影响,测距的仿真结果可满足要求。 相似文献
14.
15.
一种新的电力系统短路故障测距方法 总被引:1,自引:3,他引:1
本文提出一种新的精确测定电力系统短路故障距离的计算方法,该方法只需线 路单端电压及电流测量值,不受系统电源阻抗、故障类型及接地电阻等因素的 影响;同时该方法建立在电力线路精确的分布参数模型的基础上,因此为提高 测距精度奠定了理论基础。 相似文献
16.
10kV电力线接地故障诊断系统 总被引:5,自引:0,他引:5
本文介绍一套检测10 kV电力网对地短路故障的诊断系统。该系统基于模拟 电路故障诊断理论,采用单片机自动检测系统,快速对故障点进行分支定位。 相似文献
17.
电力系统暂态过程同步记录的研究 总被引:4,自引:0,他引:4
电力系统暂态保护与控制具有广阔的应用前景,但通常的微机保护及故障录波满足不了其对高速同步采集的要求。文中设计了GPS同步高速采集系统,具有大容量的存储空间,能同步记录电力系统各变电站各种扰动作用下的变化过程。并介绍了基于同步高速采集技术的输电网故障行波定位系统。该技术已通过动模试验,记录准确,性能可靠。 相似文献
18.
19.
20.
针对树形配电线路特点,选取适当频率的正弦诊断信号,建立分布参数电路模型。相间短路故障后,在线路始端和所有末端分别施加正弦诊断信号,并检测激励所在端口的电压电流相量,以此实现故障分支的识别和短路点的定位,大量的计算机仿真和在仿真线上的实验表明,本方法有效。 相似文献