首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new acridine fluoroionophore containing two diethanolamine ligands, 4,5-bis(N,N-di (2-hydroxyethyl)iminomethyl)acridine (BHIA), was designed and synthesized based on the fluorophore-spacer-receptor format. And its fluorescent sensing behavior towards metal ions was investigated in buffered aqueous media. The presence of Cd2+ induces the formation of a 1:1 ligand/metal complex at neutral pH, which exhibits enhanced emission at 454 nm. The fluorescence intensity is linear with the Cd2+ concentration in the range of 1.0 × 10−6 to 3.0 × 10−5 M (R = 0.9967). Experimental results show a low interference response towards other metal ions. The selective switch-on fluorescence response of BHIA to Cd2+ makes it suitable for sensing of Cd2+ in aqueous solution. The detection limit is 1.3 × 10−7 M. Moreover, the results indicated that BHIA was a reversible chemosensor for Cd2+, which makes it attractive for sensing applications.  相似文献   

2.
For the first time a novel derivatized multi-walled carbon nanotubes-based Pb2+ carbon paste electrode is reported. The electrode with optimum composition, exhibits an excellent Nernstian response to Pb2+ ion ranging from 5.9 × 10−10 to 1.0 × 10−2 M with a detection limit of 3.2 × 10−10 M and a slope of 29.5 ± 0.3 mV dec−1 over a wide pH range (2.5-6.5) with a fast response time (25 s) at 25 °C. Moreover, it also shows a high selectivity and a long life time (more than 3 months). Importantly, the response mechanism of the proposed electrode was investigated using AC impedance technique. Finally, the electrode was successfully applied for the determination of Pb2+ ion concentration in environmental samples, e.g. soils, waste waters, lead accumulator waste and black tea, and for potentiometric titration of sulfate anion.  相似文献   

3.
In this work, an electrochemical sensor based on ordered mesoporous carbon (OMC) for the amperometric detection of isoniazid was developed. OMC was dispersed in a solution of Nafion, and the suspension was modified onto the surface of glassy carbon (GC) electrode. Cyclic voltammetry and amperometry were used to investigate the electrochemical behaviors of isoniazid on Nafion-OMC modified electrode (Nafion-OMC/GC). The results indicate that OMC can facilitate the electrochemical oxidation of isoniazid with a great decrease of overpotential in pH 7.0 phosphate buffer solution. The proposed biosensor provides excellent performance towards the determination of isoniazid with a high sensitivity of 0.031 μA/μM, a low detection limit of 8.4 × 10−8 M and wide linear range from 1.0 × 10−7 M to 3.7 × 10−4 M at +0.20 V vs. Ag/AgCl. The method was successfully applied to the determination of isoniazid tablets with satisfying results. All the results suggest that Nafion-OMC/GC electrode is a potential candidate for a stable and efficient electrochemical sensor to detect isoniazid.  相似文献   

4.
A highly sensitive hydrazine sensor was developed based on the electrodeposition of gold nanoparticles onto the choline film modified glassy carbon electrode (GNPs/Ch/GCE). The electrochemical experiments showed that the GNPs/Ch film exhibited a distinctly higher activity for the electro-oxidation of hydrazine than GNPs with 3.4-fold enhancement of peak current. The kinetic parameters such as the electron transfer coefficient (α) and the rate of electron exchange (k) for the oxidation of hydrazine were determined. The diffusion coefficient (D) of hydrazine in solution was also calculated by chronoamperometry. The sensor exhibited two wide linear ranges of 5.0 × 10−7-5.0 × 10−4 and 5.0 × 10−4-9.3 × 10−3 M with the detection limit of 1.0 × 10−7 M (s/n = 3). The proposed electrode presented excellent operational and storage stability for the determination of hydrazine. Moreover, the sensor showed outstanding sensitivity, selectivity and reproducibility properties. All the results indicated a good potential application of this sensor in the detection of hydrazine.  相似文献   

5.
A simple and sensitive method based on square wave voltammetry (SWV) at single-walled carbon nanotube (SWNT) modified edge plane pyrolytic graphite electrode (EPPGE) is proposed for the simultaneous determination of adenine and adenosine-5′-monophosphate (5′-AMP). The modified electrode exhibits remarkable electrocatalytic properties towards adenine and 5′-AMP oxidation with a peak potential of ∼850 and 1165 mV respectively. Linear calibration curves are obtained over the concentration range of 5-100 nM for adenine and 10-100 nM for 5′-AMP with sensitivity of 677 and 476 nA nM−1 for adenine and 5′-AMP respectively. The limit of detection for adenine and 5′-AMP was found to be 37 × 10−10 M and 76 × 10−10 M, respectively. The effect of pH revealed that the oxidation of adenine and 5′-AMP at SWNT modified EPPGE involved equal number of electrons and protons. The modified electrode exhibited high stability and reproducibility.  相似文献   

6.
This paper presents the amperometric biosensor that determines choline and cholinesterase activity using a screen printed graphite electrode. In order to detect H2O2 we have blanket modified the electrode material with manganese dioxide nanoparticles layer. Using layer-by-layer technique on the developed hydrogen peroxide sensitive electrode surface choline oxidase was incorporated into the interpolyelectrolyte nanofilm. Its ability to serve as a detector of choline in bulk analysis and cholinesterase assay was investigated. We examined the interferences from red-ox species and heavy metals in the blood and in the environmental sample matrixes. The sensor exhibited a linear increase of the amperometric signal at the concentration of choline ranging from 1.3 × 10−7 to 1.0 × 10−4 M, with a detection limit (evaluated as 3σ) of 130 nM and a sensitivity of 103 mA M−1 cm−2 under optimized potential applied (480 mV vs. Ag/AgCl). The biosensor retained its activity for more than 10 consecutive measurements and kept 75% of initial activity for three weeks of storage at 4 °C. The R.S.D. was determined as 1.9% for a choline concentration of 10−4 M (n = 10) with a typical response time of about 10 s. The developed choline biosensor was applied for butyrylcholinesterase assay showing a detection limit of 5 pM (3σ). We used the biosensor to develop the cholinesterase inhibitor assay. Detection limit for chlorpyrifos was estimated as 50 pM.  相似文献   

7.
A label-free DNA biosensor for hybridization detection of short DNA species related to the transgenic plants gene fragment of cauliflower mosaic virus (CaMV) 35S promoter was developed in this paper. The nanocomposite containing chitosan (CS) and mutiwalled carbon nanotubes (MWNTs) was first coated on a glassy carbon electrode. Then a highly reactive dialdehyde reagent of glutaraldehyde (GTD) was applied as an arm linker to covalently graft the 5′-amino modified probe DNA to the CS-MWNTs surface via the facile aldehyde-ammonia condensation reaction. The hybridization capacity of the developed biosensor was monitored with electrochemical impedance spectroscopy (EIS) using [Fe(CN)6]3−/4− as an indicating probe, and the experimental results showed that the biosensor had fast hybridization rate and low background interference. A wide dynamic detection range (1.0 × 10−13-5 × 10−10 M) and a low detection limit (8.5 × 10−14 M) were achieved for the complementary sequence. In addition, the hybridization specificity experiments showed that the sensing system can accurately discriminate complementary sequence from mismatch and noncomplementary sequences.  相似文献   

8.
A simple and new way to immobilize glucose dehydrogenase (GDH) enzyme onto nile blue (NB) covalently assembled on the surface of functionalized single-walled carbon nanotubes (f-SWCNTs) modified glassy carbon (GC) electrode (GDH/NB/f-SWCNTs/GC electrode) was described. The GDH/NB/f-SWCNTs/GC electrode possesses promising characteristics as glucose sensor; a wide linear dynamic range of 100-1700 μM, low detection limit of 0.3 μM, fast response time (1-2 s), high sensitivity (14 μA cm−2 mM−1), anti-interference ability and anti-fouling. Moreover, the performance of the GDH/NB/f-SWCNTs/GC bioanode was successfully tested in a glucose/O2 biofuel cell. The maximum power density delivered by the assembled glucose/O2 biofuel cell could reach 32.0 μW cm−2 at a cell voltage of 0.35 V with 40 mM glucose. The present procedure can be applied for preparing a potential platform to immobilize different enzymes for various bioelectrochemical applications.  相似文献   

9.
This work reports on the Cu2+ chemosensing behaviour of self-organized micro-array structures of a novel donor-acceptor bichromophoric compound anchored onto Ag nanoisland films. The system exhibits quenching of the fluorescence in the presence of Cu2+ ions, with detection range extending from 2 × 10−8 M up to 3 × 10−6 M and limit of detection (LOD) of 8 × 10−9 M. The quenching of fluorescence is accompanied by a quenching of SERS signal from the metal-organic structure, which is consistent with an electron transfer between the copper cation and the organic moiety. The self-organization property of the sensing complexes into micrometric arrays offers great potential for miniaturization and future development of Cu2+ detection systems based on real-time observation of fluorescence or SERS quenching by fluorescence microscopy or microRaman spectroscopy.  相似文献   

10.
We are introducing a macroporous Au-Pt hybrid 3D electrode to be used for enzyme-free glucose detection. The proposed hybrid electrode was fabricated with a three dimensional structure by electroplating platinum nanoparticles onto the surface of the coral-like macroporous Au. It was then physically analyzed by using field emission scanning electron microscopy (FESEM). The porosity and window pore size of the macroporous Au electrode were 50% and 100-300 nm, respectively. The diameters of the Pt nanoparticles ranged from 10 to 15 nm. Through cyclic voltammograms in a 1 M sulfuric acid solution, we confirmed that the hybrid electrode exhibited a much larger surface activation area with a roughness factor (RF) of 2024.7 than the macroporous Au electrode with a roughness of 46.07. The highly improved surface activation area was caused by the electroplated Pt nanoparticles. The hybrid electrode exhibited a much stronger electrocatalytic activity due to glucose oxidation than the macroporous Au electrode. At 0.4 V, it responded linearly to the glucose up to 20 mM in a neutral media with a detection limit of 0.025 mM and detection sensitivity of 39.53 μA mM−1 cm−2 without being affected by interfering species. It also showed a stable recovery response to the step changes of the glucose concentration.  相似文献   

11.
Pure diamond-like carbon (DLC) thin films and boron-doped DLC thin films have been deposited on silicon substrates using femtosecond pulsed laser. The amorphous carbon materials (DLC), have been deposited at room temperature by ablating graphite targets with an amplified Ti:sapphire laser of 800 nm wavelength and a pulse duration of 150 fs in high vacuum conditions. Doping with boron has been performed by ablating alternatively graphite and boron targets.In this study, the DLC films were used as working electrodes for the electrochemical detection of trace heavy metals namely, Cd2+, Pb2+, Ni2+ and Hg2+, by using square wave anodic stripping voltammetry (SWASV) technique. Four metals were detected at −1.3 V deposition potential, and 90 s deposition time. The DLC films have been characterized by multiwavelength Raman spectrometry and high resolution scanning electron microscopy. The effect of the boron doping on the electrochemical behavior has been shown. The a-C:B 8%/Si3N4 electrode gives the more sensitive detection. The four metals are detected simultaneously with a detection limit of 1 μg/L or 2 μg/L and a dynamic range from 1 or 2 to 25 μg/L for every metal, as presented in third table of this article. The different sensitivities obtained are 6.2, 20.0, 1.2 and 6.6 μA/ppb or μA μg−1 L for Cd2+, Pb2+, Ni2+ and Hg2+, respectively.  相似文献   

12.
An electrochemical biosensor for determination of hydrogen peroxide (H2O2) has been developed by the hybrid film of poly(methylene blue) and FAD (PMB/FAD). The PMB/FAD hybrid film was performed in PBS (pH 7) containing methylene blue and FAD by cyclic voltammetry. Repeatedly scanning potential range of −0.6-1.1 V, FAD was immobilized on the electrode surface by electrostatic interaction while methylene blue was electropolymerized on electrode surface. This modified electrode was found surface confined and pH dependence. It showed good electrocatalytic reduction for H2O2, KBrO3, KIO3, and NaClO as well as electrocatalytic oxidation for NADH. At an applied potential of −0.45 V vs. Ag/AgCl, the sensor showed a rapid and linear response to H2O2 over the range from 0.1 μM to 960 μM, with a detection limit of 0.1 μM and a significant sensitivity of 1109 μA mM−1 cm−2 (S/N = 3). It presented excellent stability at room temperature, with a variation of response current less than 5% over 30 days.  相似文献   

13.
The electrocatalysis of hydrazine oxidation by poly-ethylenedioxy pyrrole (PEDOP)-coated MWCNTs-palladium nanoparticles [PEDOP/MWCNTs-Pd] was investigated as an electrochemical sensor on the surface of glassy carbon electrode (GCE) in aqueous medium. Electrochemical oxidation of hydrazine in phosphate buffer (pH 7.4) was performed using cyclic voltammetry (CV) and chronoamperometry (CA) methods. Using the proposed electrode, the catalytic oxidation peak current of hydrazine was high and the overpotential of its oxidation decreased. Based on the obtained results, a mechanism for electrooxidation of hydrazine at [PEDOP/MWCNTs-Pd/GCE] demonstrated an irreversible diffusion-controlled electrode process and a four-electron transfer involved in the overall reaction. The experimental results showed that the mediated oxidation peak currents of the hydrazine were linearly dependent on the concentration of hydrazine in the range of 1.0 × 10−7 to 5.0 × 10−3 M. The detection limit (S/N = 3) was found to be 4 × 10−8 M with a fast response time of 10 s.  相似文献   

14.
In this work, we demonstrated a sensitive and selective electrochemical sensing protocol for the detection of TNT prepared from alkanethiols self-assembled on AuNPs modified glassy carbon (GC) electrode with preadsorbed templates of TNT. It demonstrated that the 2D molecular imprinting monolayers (MIMs) can provide a better site accessibility and lower mass-transfer resistance, while the AuNPs can enhance electrode conductivity, facilitate the electron transfer and increase the amount of TNT-imprinted sites. The prepared sensor showed not only high selectivity toward TNT in comparison to other similar nitroaromatic compounds (NACs), but also a wide linear range over TNT concentration from 4.0 × 10−8 to 3.2 × 10−6 M with a detection limit of 1.3 × 10−8 M (S/N = 3). Moreover, the imprinted sensor has been applied to the determination of TNT in spiked environmental water samples and shows promise for fast and sensitive measurement of trace levels of TNT in real samples.  相似文献   

15.
In present paper, the graphene doped carbon paste electrode (CPE) was firstly prepared with the addition of graphene into the carbon paste mixture. Compared with conventional CPE, an improved electrochemical response of graphene doped CPE toward the redox couple of Fe(CN)63−/4− was demonstrated owing to the excellent electrical conductivity of graphene. The graphene doped CPE was further used for the successful determination of ascorbic acid (AA), and it showed an excellent electrocatalytic oxidation activity toward AA with a lower overvoltage, pronounced current response, and good sensitivity. Under the optimized experimental conditions, the proposed electrochemical AA sensor exhibited a rapid response to AA within 5 s and a linear calibration plot ranged from 1.0 × 10−7 to 1.06 × 10−4 M was obtained with a detection limit of 7.0 × 10−8 M.  相似文献   

16.
An electrochemical sensor based on graphene-polyaniline (GR-PANI) nanocomposite for voltammetric determination of 4-aminophenol (4-AP) is presented. The electrochemical behavior of 4-AP at the GR-PANI composite film modified glassy carbon electrode (GCE) was investigated by cyclic voltammetry. 4-AP exhibits enhanced voltammetric response at GR-PANI modified GCE. This electrochemical sensor shows a favorable analytical performance for 4-AP detection with a detection limit of 6.5 × 10−8 M and high sensitivity of 604.2 μA mM−1. Moreover, 4-AP and paracetamol can be detected simultaneously without interference of each other in a large dynamic range.  相似文献   

17.
A novel Ni2+ optode was prepared by covalent immobilization of thionine, 3,7-diamine-5-phenothiazoniom thionineacetate, in a transparent agarose membrane. Influences of various experimental parameters on Ni2+ sensing, including the reaction time, the solution pH and the concentration of reagents were investigated. Under the optimized conditions, a linear response was obtained for Ni2+ concentrations ranging from 1.00 × 10−10 to 1.00 × 10−7 mol l−1 with an R2 value of 0.9985. The detection limit (3σ) of the method for Ni2+ was 9.30 × 10−11 mol l−1. The influence of several potentially interfering ions such as Ag+, Hg2+, Cd2+, Zn2+, Pb2+, Cu2+, Mn2+, Co3+, Cr3+, Al3+ and Fe3+ on the determination of Ni2+ was studied and no significant interference was observed. The membrane showed a good durability and short response time with no evidence of reagent leaching. The membrane was successfully applied for the determination of Ni2+ in environmental water samples.  相似文献   

18.
A biosensor based on bovine serum albumin (BSA) and poly-o-phenylenediamine (PoPD)/carbon-coated nickel (C-Ni) nanobiocomposite film modified electrode has been developed to study the interaction of BSA with papaverine (PAP). The well-dispersed C-Ni nanoparticles were dripped onto the glassy carbon electrode (GCE) surface firstly, and PoPD films were subsequently electropolymerized by cyclic voltammetry (CV) to prepare PoPD/C-Ni/GCE. Finally, the BSA was easily immobilized on the PoPD films via electrostatic adsorption. The morphology and the electrochemical properties of the fabricated composite electrodes were examined by scanning electron microscope (SEM) and electrochemical impedance spectroscopy (EIS), respectively. The interaction of PAP with BSA was monitored by differential pulse voltammetry (DPV), using PoPD as the electrochemical indicator. The binding constant (K), obtained by DPV, was 1.7 × 104 L/mol, which was consistent with the fluorescence analysis. This constructed biosensor also exhibited a fine linear correlation with PAP concentration range of 2.5 × 10−9-4.5 × 10−5 mol/L and a detection limit of 8.3 × 10−10 mol/L was achieved by DPV.  相似文献   

19.
A very sensitive and reversible optical chemical sensor based on dithizone as chromoionophore immobilized within a plasticized carboxylated PVC film for Zn2+ determination is described. At optimum conditions (i.e. pH 5.0), the proposed sensor displays a linear response to Zn2+ over 5.0 × 10−8-5.0 × 10−6 mol L−1 range. This range was improved to 2.5 × 10−8-5.8 × 10−5 mol L−1 range by applying principle component-feed forward artificial neural network with back-propagation training algorithm (PC-ANNB). Detection limit of 8.0 × 10−9 mol L−1 was obtained. The sensor is fully reversible within the dynamic range and the response time (t95%) is approximately 4 min under batch conditions. In addition to its high stability and reproducibility, the sensor shows good selectivity towards Zn2+ ion with respect to common metal cations. The sensor was successfully applied for determination of Zn2+ ion in hair sample.  相似文献   

20.
A promising material of poly(lactic-co-glycolic acid) (PLGA) and, room temperature ionic liquid (ILs) (1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM]BF4) was firstly used as an immobilization matrix to entrap proteins and its bioelectrochemical properties were studied. Direct electrochemistry and electrocatalytic behaviors of hemoglobin (Hb) entrapped in the PLGA/ILs composite film on the surface of glass carbon electrode were investigated. UV-vis spectroscopy, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to characterize the composite film. The obtained results demonstrated that the Hb molecule in the film kept its native structure and showed its good electrochemical behavior. A pair of well-defined redox peaks of Hb was obtained at the Hb/PLGA/ILs composite film-modified GC electrode through direct electron transfer between the protein and the underlying electrode. The proposed biosensor showed good reproducibility and high sensitivity to H2O2 with the detection limit of 2.37 × 10−7 M (S/N = 3). In the range of 5.0 × 10−6 to 8.05 × 10−3 M, the catalytic reduction current of H2O2 was proportional to its concentration. The apparent Michaelis-Menten constant of Hb in the PLGA/ILs composite film was estimated to be 0.069 mM, showing its high affinity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号