To address the effect of metro train blockage on the critical ventilation velocity in a long tunnel, a series of scenarios were conducted numerically through this study, including different fire sizes (5-10 MW), metro train lengths (80-120 m), and blockage ratios (φ, 0.50, and 0.57). It is known from the numerical results that the metro train length shows a limited effect on the critical ventilation velocity, which is because the longitudinal ventilation has become stable before reaching the fire source to prevent smoke back-layering, and increasing the metro train length only increases the distance of stabilizing the longitudinal ventilation. The blockage ratio shows an obvious influence on the critical ventilation velocity, which is because the presence of the metro train can obviously reduce the flow cross-sectional area of the tunnel. An empirical model is developed as well, while it is known that the critical ventilation velocity increases with the one-third power of dimensionless heat release rate and (1-φ). The research outcomes of this study provide a technical guide for the design of the metro tunnel and the relevant emergency management of fire rescue under fire conditions.  相似文献   

2.
A series of numerical simulations were conducted in order to investigate the characteristics of smoke back‐layering and critical ventilation in the road tunnel at high altitude with reduced ambient atmospheric pressures. The results indicated that the smoke back‐layering length decreases with the reduction of ambient pressure. Meanwhile, the dimensionless critical longitudinal ventilation velocity decreases with one‐third power of the factor of ambient pressure at high altitude. By modifying the traditional dimensionless fire heat release rate with ambient pressure, new models were deduced to predict the smoke back‐layering length and critical ventilation velocity in the road tunnel at high altitude.  相似文献   

3.
The critical ventilation velocity is almost the most well‐investigated fire phenomenon in the tunnel fire research field whereas previous studies have always investigated it when the fire source is distant from the downstream tunnel exit. Fortunately, a recent study provided a set of data on the critical ventilation velocity for tunnel fires occurring near tunnel exits by small‐scaled experiments, nevertheless, with a lack of further analysis. To demonstrate the relationship of the critical ventilation velocity and the distance between the fire and tunnel exit more explicitly and detailedly, a quantitative and graphical study was carried out and a correlation was presented in this paper. Inspired by this, a set of small‐scaled experiments were carried out to investigate the influence of different longitudinal fire locations on maximum smoke temperature under the tunnel ceiling. Results show that unlike the critical ventilation velocity, the maximum smoke temperature was not obviously affected by longitudinal fire location. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
Investigation of smoke bifurcation flow has been receiving more attentions, however, delicate quantitative analyses on different regions of the bifurcation flow have rarely been addressed. In this study, a series of small-scale experiments were conducted to investigate smoke bifurcation flow in longitudinal ventilated tunnels. Results show that when longitudinal ventilation velocity increases to a certain value, the smoke bifurcation phenomenon emerges, and a low-temperature region forms in the center of the tunnel. Similar to the natural conditions, smoke development under relatively strong ventilation can also be subdivided into four regions. With the increase of ventilation velocity, the ceiling impact region, side wall impact region, and convergence region of two smoke streams move further downstream, indicating that the bifurcation phenomenon becomes more evident. A simple model is proposed based on theoretical analysis and experimental phenomenon to predict two characteristic lengths of smoke bifurcation flow: the offset distance of ceiling impact region and the length of low-temperature region. Both characteristic lengths increase with ventilation velocity and can be well correlated with the dimensionless ventilation velocity defined in Equation (2) ( V ). The results of this work could provide references for both tunnel ventilation designers and fire science researchers.  相似文献   

5.
Understanding smoke temperature distributions and transport characteristics is of great importance to control and exhaust thermal-driven smoke. However, previous studies have focused on this problem in plain areas, whereas ambient pressure decreases as elevation increases. This study investigates the influence of ambient pressure on the hot gas temperature distribution and movement characteristics in a tunnel fire. A series of numerical simulations are carried out in a vehicle tunnel with various heat release rates (HRRs) and ambient pressures. The results show that the maximum temperature and longitudinal temperature distribution under the tunnel ceiling increase with decreasing ambient pressure due to less heat loss caused by lower air density. In addition, the vertical temperatures of the smoke are slightly higher under lower ambient pressure, and this phenomenon makes the smoke spread slightly faster while the smoke layer thickness remains nearly the same under different ambient pressures. The results can provide a reference for tunnel lining design and ventilation arrangements in high-altitude areas.  相似文献   

6.
W. K. Chow 《火与材料》1995,19(3):101-108
Performance of three fire zone models BR12, CCFM.VENTS and CFAST in simulating forced ventilation fires with low heat release and high ventilation rates were studied experimentally. A fire chamber of length 4.0 m, width 3.0 m height 2.8 m with adjustable ventilation rates was used. Burning tests were carried out with wood cribs and methanol to study the preflashover stage of a compartmental fire and the effect of ventilation. The mass loss rate of fuel, temperature distribution of the compartment and the air intake rate were measured. The heat release rates of the fuel were calculated from the measured mass loss rate. The smoke temperature was used as the validation parameter. A scoring system is proposed to compare the results predicted by the three models. An empirical expression for calculating the smoke temperature is assessed. Lastly, the Computational Fluid Dynamics technique is also used for comparing the simulated fire environment.  相似文献   

7.
This study investigated the influence of the longitudinal airflow on the smoke propagation in a tunnel by large-eddy simulation, which is now widely applied to study the turbulent flow. The smoke movement characteristics were studied in detail, with varying the longitudinal airflow in the tunnel. Six fire scenarios have been simulated with Fire Dynamics Simulator (FDS) and the results of the longitudinal distribution of CO concentration, temperature distribution, interface height, stratification, and the efficiency of smoke extraction in the tunnel have been analyzed to evaluate the different fire cases. FDS predicted a CO concentration distribution compared to calculated values using the Hu model. Furthermore, the predicted maximum smoke temperatures are compared to those given by the Kurioka model. A reasonably good agreement has been obtained for both models. The obtained results showed that the increase of the forced airflow velocity has for results a loss of stratification and significant decrease in the efficiency of extraction.  相似文献   

8.
In coal mining, smoke flow from tunnel fires can easily cause a large number of deaths in the ventilation network. But the optimal smoke flow path control methods and automatic control system were lacked. In order to improve the efficiency of fire emergency rescue, the control mechanism and regional linkage control system for fire induced smoke flow in ventilation network was studied. Based on a ventilation system in coal mines, different fire scenarios for smoke flow were analysed using ventilation simulation software (VSS). Smoke flow control methods were simulated under different ventilation modes, a contrastive analysis was conducted for the respective effects and the optimal smoke flow path control methods were confirmed in different fire scenarios. A new type of ventilation facility, regional monitoring sub-stations and remote linkage control platforms were developed for smoke control. A reliability evaluation model for the control system was established by Bayesian network. The failure of the linkage control is 98.9%, the monitoring sub-station is 64.4%, the sub-station communication is 43.9%; thus, a double insurance of the control process must be realised. Since its application, the proposed regional linkage control system has been repeatedly tested through fire drills, and good results have been obtained.  相似文献   

9.
In a longitudinally ventilated tunnel fire, the backlayering flow propagated in the opposite direction to the air current is the most fatal contaminations to users which are blocked upstream of the fire. In the present paper, numerical simulations were conducted using Fire Dynamic Simulator, which is based on large eddy simulations to estimate the backlayering arrival time in a longitudinally ventilated tunnel fire. The effect of a vehicle obstruction on the backlayering arrival time will be also investigated. For this, a vehicle model occupying about 31% of the tunnel cross section is simulated upstream of the fire source with its location relative to the tunnel floor is varied. The numerical investigation shows that the inertia and the buoyancy forces produced by ventilation and fire, respectively, affect the backlayering spread. The backlayering arrival time increases with the longitudinal ventilation velocity while it decreases with the fire heat release rate. When a vehicle obstruction existed within the tunnel, the numerical results show an increase of backlayering arrival time. This increase is significantly more important with the fire distance when the vehicle obstruction approaches the tunnel floor. Two correlations are developed, with and without obstruction in the tunnel, to predict the backlayering arrival time against the distance to fire. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
Fires in enclosures equipped with mechanical ventilation remain one of the key issues for fire safety assessment in multifamily homes and industries. Therefore, a wide variation of methods for preventing smoke spread through the ventilation system exist and are applied, in performance‐based designs. Through the use of the heating, ventilation and air conditioning (HVAC) model in the fire dynamics simulator, several different common and less common methods for preventing smoke spread in the ventilation system were tested. The effects on smoke spread with changing building leakage and fire growth rates were also investigated. The results were evaluated by determining the total soot spread from the fire room to other compartments connected to the ventilation system, as well as soot/thermal load on the fans and system in general. The maximum and average heat release rate was also of interest and hence compared between systems. It was found that, while many methods perform similar, a few proven methods, such as fire and smoke dampers, performed very well with very little smoke spread to the rest of the system. The study should be considered as an introduction to implementing a similar methodology in specific cases because different ventilations systems will present very different challenges and weaknesses. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
The materials and products used in passenger trains may not be the first ignited element, but during the fire development, these materials, especially ceiling linings and wall coverings, contribute significantly to the fire growth. The fire safety requirements in passenger trains consist mainly of bench‐scale tests, with particular focus on the sample geometry, position and fire exposition. When this information is extrapolated to real end use conditions limitations appear. In this paper, a discussion of the use of fire dynamics simulator model and heat release rate experiments in cone calorimeter (bench‐scale test) is presented in order to represent the fire development in a passenger train compartment. For the study, two fire scenarios were selected: (1) the single burning item SBI test (modified) and (2) a passenger train compartment. Initially, the limitations of the assumptions and hypothesis made when producing the model were analyzed and the research team carried out a sensitivity study of the model results considering different grid sizes. In order to validate the model, both bench‐ and full‐scale fire tests were considered based on the results provided by the European research program FIRESTARR. The limitations and uncertainties in the results demonstrate the importance of two basic factors: the incident heat flux in the cone calorimeter tests and the prescribed ignition temperature. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

12.
The combustion characteristics of methanol‐gasoline blends pool fires were studied in a series of full‐scale tunnel experiments conducted with different methanol and gasoline blends. The parameters were measured including the mass loss rate, the pool surface temperature, the fire plume centerline temperature, the ceiling temperature, the smoke layer temperature profile, the flame height, and the smoke layer interface height. The gasoline components were analyzed by GC‐MS. The effects of azeotropism on the combustion characteristics of the different blends were discussed. On the basis of the results of the fire plume centerline temperature, the ceiling temperature, and the flame height, it shows that the tunnel fire regime gradually switches from fuel controlled to ventilation controlled with increasing gasoline fractions in the blends. The fire plume can be divided into 3 regions by the fire plume centerline temperature for the different blends. The N‐percentage rule to determine the smoke layer interface height is found to be applicable for tunnel fires with different blends for N = 26.  相似文献   

13.
Based on large eddy simulation, a series of long tunnel fire experiments with different heat release rates (HRRs) and altitudes were carried out. The vertical temperature and thickness of fire smoke are studied. The simulation results show that the higher the altitude, the lower the flame temperature rise, while the change of smoke plume temperature rise is opposite. The movement of smoke in the tunnel can be divided into four regions, and the smoke layer thickness in the longitudinal direction of the tunnel corresponds to the latter three regions. The thickness in Region II increases along the longitudinal direction, the thickness in Region III is a constant value, and the thickness in Region IV increases along the longitudinal direction. Besides, the change of altitude only has an effect on the smoke layer thickness in Region IV. Then, by considering the altitude, HRR, and smoke layer thickness, and using dimensional analysis, an empirical formula for predicting the smoke layer thickness under the influence of altitude in Region IV was established.  相似文献   

14.
In more and more tunnels, natural ventilation mode with vertical shafts has been gradually employed. However, there are few studies investigating the influences of fire and shaft positions on natural ventilation performance currently. Therefore, this study investigated the effects of the transverse distance from fire source to tunnel sidewall, the longitudinal distance from fire source to shaft, and the transverse distance from shaft to sidewall on natural ventilation effectiveness in a tunnel fire by using Fire Dynamics Simulator. The typical characteristic parameters of smoke, such as mass flow rate, temperature distribution, and velocity vector were analyzed; besides, the phenomenon of plug‐holing was discussed. The results have shown that the mass flow rate of gas exhausted by the shaft decreases slightly with the increase of longitudinal distance from fire source to shaft. When the longitudinal distance from fire source to shaft is constant, changing the transverse distance from shaft to sidewall will have a more obvious effect on the effectiveness of exhausting smoke than changing the transverse distance from fire source to sidewall; in addition, the phenomenon of plug‐holing is more serious when the shaft is close to the sidewall.  相似文献   

15.
Fei Tang  Yuantao Zhu  Lei Chen 《火与材料》2020,44(7):1004-1012
Smoke is the main cause of death in tunnel fires. It is one of the important measures to maintain smoke stratification in the early stage of tunnel fire. This article focused on experimentally studying the combined effect of lateral concentrated smoke extraction and longitudinal ventilation on the smoke stratification, which never be revealed before. The velocity of the smoke layer and air layer, vertical temperature distribution, and the flow patterns of the smoke were measured. It was found that the longitudinal ventilation and lateral concentrated smoke extraction would affect the flow of the smoke and change the shear velocity between the smoke layer and air layer, then, the patterns of the smoke layer will be affected. And the flow patterns with Froude (Fr) number can be classified into three categories: (a)Fr < 0.6 , with stable smoke stratification; (b) 0.6 < Fr < 0.85 , with a stable smoke stratification but the blurring interface; and (c) Fr > 0.85 , the smoke layer is completely unstable. The result can provide a reference for ventilation design of immersed tube tunnels.  相似文献   

16.
根据电缆隧道实际环境,建立电缆水平燃烧试验平台,研究不同火灾荷载和通风速度下,受防火涂料保护电缆延燃长度的变化规律。结果表明:一定风速条件下,电缆延燃长度随敷设宽度增加呈指数增长,可根据隧道内通风速度和电缆束宽度近似预测电缆延燃长度,从而为电缆隧道的防火设计提供依据。  相似文献   

17.
Eyewitnesses describe burning pavement surfaces in extreme fire scenarios. However, it was believed that the pavement plays a negligible role in comparison to other items feeding such an extreme fire at the same time. The asphalt mixtures used differ widely, thus raising the question as to whether this conclusion holds for all kinds of such materials. Three different kinds of asphalt mixtures were investigated with the aim of benchmarking the fire risks. Cone calorimeter tests are performed at an irradiance of 70kWm?2. All three investigated asphalts burn in extreme fire scenarios. The fire response (fire load, time to ignition, maximum heat release rate and smoke production) is quite different and varies by factors of up to 10 when compared to each other. The fire load per mass is always very low due to the high content of inert minerals, whereas the effective heat of combustion of the volatiles is quite typical of non‐flame retarded organics. The heat release rate and fire growth indices are strongly dependent on the fire residue and thus the kind of mineral filler used. Comparing with polymeric materials, the investigated Mastic Asphalt and Stone Mastic Asphalt may be called intrinsically flame resistant, whereas the investigated Special Asphalt showed a pronouncedly greater fire risk with respect to causing fire growth and smoke. Thus the question is raised as to whether the use of certain kinds of asphalts in tunnels must be reconsidered. Apart from the binder used, the study also indicates varying the kind of aggregate as a possible route to eliminate the problem. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
In this work, an efficient approach to improving the fire retardancy and smoke suppression for intumescent flame‐retardant polypropylene (PP) composites is developed via incorporating functionalized sepiolite (organo‐modified sepiolite [ONSep]). The PP composites with different amounts of intumescent flame retardants and ONSep were prepared by melt compounding. The morphology, thermal behavior, fire retardancy, smoke suppression, and mechanical property of flame‐retardant PP composites were studied. The results indicate an appropriate amount of ONSep in the flame‐retardant PP composites can increase thermal degradation temperature and char formation as well as a reduction of the peak heat release rate and total heat release; moreover, the addition of ONSep significantly decreases the CO production, total smoke production, smoke production rate, and smoke temperature. Simultaneously, the impact strength of intumescent flame‐retardant PP composite is also maintained by introducing an appropriate amount of ONSep as compared with that without ONSep.  相似文献   

19.
This study aims to develop a complete methodology for assessing flammability hazards of typical fuels (ie, transformer oil, hydraulic oil, gear oil, and lubricating grease) used in a wind turbine nacelle by combining different experimental techniques such as thermogravimetric analysis and cone calorimetry. Pyrolysis properties (onset temperature, temperature of maximum mass loss rate, and mass residue) and reaction‐to‐fire properties (ignition time, heat release rate, mass loss rate, and smoke release rate) were determined and used for a preliminary assessment of thermal stability and flammability hazards. Additional indices, for ignition and thermal behavior (effective heat of combustion, average smoke yield, and smoke point height, heat release capacity, fire hazard parameter, and smoke parameter, were calculated to provide a more advanced assessment of the hazards in a wind turbine. Results show that pyrolysis of transformer oil, lubricating grease, hydraulic oil, and gear oil occur in the range of 150°C to 550°C. Lubricating grease and transformer oil show the higher and lower thermal stabilities with maximum pyrolysis rate temperatures of 471°C and 282°C, respectively. The measured relation between ignition time and radiant heat flux agrees well with Janssens method (a power of 0.55). The aforementioned indices appear to provide a reasonable prediction of performance under real fire conditions according to a full‐scale fire test documented by Declercq and Van Schevensteen. The results of the study indicate that transformer oil is the easiest to ignite while lubricating grease is the most difficult to ignite but also has the highest smoke production rate; that transformer oil has the highest heat release rate while gear oil has the lowest; and that the fire hazard parameter is the highest for transformer oil and the smoke parameter is the highest for lubricating grease. The potential of this type of work to design safer wind turbines under performance‐based approaches is clearly clarified.  相似文献   

20.
There is little consensus within the fire science community on interpretation of cone calorimeter data, but there is a significant need to screen new flammability modified materials using the cone calorimeter. This article is the result of several discussions aiming to provide guidance in the use and interpretation of cone calorimetry for those directly involved with such measurements. This guidance is essentially empirical, and is not intended to replace the comprehensive scientific studies that already exist. The guidance discusses the fire scenario with respect to applied heat flux, length scale, temperature, ventilation, anaerobic pyrolysis and set‐up represented by the cone calorimeter. The fire properties measured in the cone calorimeter are discussed, including heat release rate and its peak, the mass loss and char yield, effective heat of combustion and combustion efficiency, time to ignition and CO and smoke production together with deduced quantities such as FIGRA and MARHE. Special comments are made on the use of the cone calorimeter relating to sample thickness, textiles, foams and intumescent materials, and the distance of the cone heater from the sample surface. Finally, the relationship between cone calorimetry data and other tests is discussed. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   