首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 295 毫秒
1.
We aimed to characterize the presence of microbial secondary metabolites in homes and their association with moisture damage, mold, and asthma development. Living room floor dust was analyzed by LC‐MS/MS for 333 secondary metabolites from 93 homes of 1‐year‐old children. Moisture damage was present in 15 living rooms. At 6 years, 8 children had active and 15 lifetime doctor‐diagnosed asthma. The median number of different metabolites per house was 17 (range 8–29) and median sum load 65 (4–865) ng/m2. Overall 42 different metabolites were detected. The number of metabolites present tended to be higher in homes with mold odor or moisture damage. The higher sum loads and number of metabolites with loads over 10 ng/m2 were associated with lower prevalence of active asthma at 6 years (aOR 0.06 (95% CI <0.001–0.96) and 0.05 (<0.001–0.56), respectively). None of the individual metabolites, which presence tended (P < 0.2) to be increased by moisture damage or mold, were associated with increased risk of asthma. Microbial secondary metabolites are ubiquitously present in home floor dust. Moisture damage and mold tend to increase their numbers and amount. There was no evidence indicating that the secondary metabolites determined would explain the association between moisture damage, mold, and the development of asthma.  相似文献   

2.
Indoor bioaerosols, such as mold spores, have been associated with respiratory symptoms in patients with asthma; however, dose–response relationships and guidelines on acceptable levels are lacking. Furthermore, a causal link between mold exposure and respiratory infections or asthma remains to be established. The aim of this study was to determine indoor concentrations of Aspergillus fumigatus and a subset of clinically relevant fungi in homes of people with asthma, in relation to markers of airways colonization and sensitization. Air and dust samples were collected from the living room of 58 properties. Fungal concentrations were quantified using mold‐specific quantitative PCR and compared with traditional microscopic analysis of air samples. Isolation of A. fumigatus from sputum was associated with higher airborne concentrations of the fungus in patient homes (P = 0.04), and a similar trend was shown with Aspergillus/Penicillium‐type concentrations analyzed by microscopy (P = 0.058). No association was found between airborne levels of A. fumigatus and sensitization to this fungus, or dustborne levels of A. fumigatus and either isolation from sputum or sensitization. The results of this study suggest that the home environment should be considered as a potential source of fungal exposure, and elevated home levels may predispose people with asthma to airways colonization.  相似文献   

3.
Evidence is accumulating that indoor dampness and mold are associated with the development of asthma. The underlying mechanisms remain unknown. New Zealand has high rates of both asthma and indoor mold and is ideally placed to investigate this. We conducted an incident case‐control study involving 150 children with new‐onset wheeze, aged between 1 and 7 years, each matched to two control children with no history of wheezing. Each participant's home was assessed for moisture damage, condensation, and mold growth by researchers, an independent building assessor and parents. Repeated measures of temperature and humidity were made, and electrostatic dust cloths were used to collect airborne microbes. Cloths were analyzed using qPCR. Children were skin prick tested for aeroallergens to establish atopy. Strong positive associations were found between observations of visible mold and new‐onset wheezing in children (adjusted odds ratios ranged between 1.30 and 3.56; P ≤ .05). Visible mold and mold odor were consistently associated with new‐onset wheezing in a dose‐dependent manner. Measurements of qPCR microbial levels, temperature, and humidity were not associated with new‐onset wheezing. The association between mold and new‐onset wheeze was not modified by atopic status, suggesting a non‐allergic association.  相似文献   

4.
Resuspension of microbes in floor dust and subsequent inhalation by human occupants is an important source of human microbial exposure. Microbes in carpet dust grow at elevated levels of relative humidity, but rates of this growth are not well established, especially under changing conditions. The goal of this study was to model fungal growth in carpet dust based on indoor diurnal variations in relative humidity utilizing the time-of-wetness framework. A chamber study was conducted on carpet and dust collected from 19 homes in Ohio, USA and exposed to varying moisture conditions of 50%, 85%, and 100% relative humidity. Fungal growth followed the two activation regime model, while bacterial growth could not be evaluated using the framework. Collection site was a stronger driver of species composition (P = 0.001, R2 = 0.461) than moisture conditions (P = 0.001, R2 = 0.021). Maximum moisture condition was associated with species composition within some individual sites (P = 0.001-0.02, R2 = 0.1-0.33). Aspergillus, Penicillium, and Wallemia were common fungal genera found among samples at elevated moisture conditions. These findings can inform future studies of associations between dampness/mold in homes and health outcomes and allow for prediction of microbial growth in the indoor environment.  相似文献   

5.
The health impact of indoor air pollution in informal settlement households has not been extensively studied in South Africa. This cross‐sectional study investigated the association between asthma and common indoor exposures among schoolchildren from four informal settlements located in two municipalities in the Western Cape Province. A total of 590 children, aged 9‐11 years, were recruited. The International Study of Asthma and Allergies in Childhood (ISAAC) questionnaire was administered to caregivers. Pulmonary function assessment included spirometry and fractional exhaled nitric oxide (FeNO). Phadiatop test for atopy was done. The prevalence of doctor‐diagnosed asthma was 3.4% (n = 20) among whom only 50% were on treatment. The prevalence of current wheeze was 12.9%, and 17.6% had airway obstruction (FEV1 < lower limit of normal), while 10.2% had airway inflammation (FeNO > 35 ppb). In adjusted logistic regression models, dampness, visible mold growth, paraffin use for cooking, and passive smoking were associated with a twofold to threefold increased risk in upper and lower airway outcomes. The strongest association was that of visible mold growth with rhinitis (adjusted odds ratio—aOR 3.37, 95% CI: 1.69‐6.71). Thus, there is a need for improved diagnosis of childhood asthma and Indoor Air Quality in informal settlement households.  相似文献   

6.
Different countries have tried to define guidelines to quantify what levels of fungi are considered as inappropriate for housing. This retrospective study analyzes indoor fungi by cultures of airborne samples from 1012 dwellings. Altogether, 908 patients suffering from rhinitis, conjunctivitis, and asthma were compared to 104 controls free of allergies. Portuguese decree law no 118/2013 (PDL118), ANSES (a French environmental and health agency) recommendations, and health regulations of Besançon University Hospital were applied to determine the rates of non‐conforming dwellings, which were respectively 55.2%, 5.2%, and 19%. Environmental microbiological results and medical data were compared. The whole number of colonies per cubic meter of air was correlated with asthma (P < 0.001) and rhinitis (P = 0.002). Sixty‐seven genera and species were detected in bedrooms. Asthma was correlated to Aspergillus versicolor (P = 0.004) and Cladosporium spp. (P = 0.02). Thresholds of 300 cfu/m3 for A. versicolor or 495 cfu/m3 for Cladosporium spp. are able to discriminate 90% of the asthmatic dwellings. We propose a new protocol to obtain an optimal cost for indoor fungi surveys, excluding surface analyses, and a new guideline to interpret the results based on >1000 cfu/m3 of whole colonies and/or above threshold levels for A. versicolor or Cladosporium spp.  相似文献   

7.
Organophosphate esters are used as additives in flame retardants and plasticizers, and they are ubiquitous in the indoor environment. Phosphorus flame retardants (PFRs) are present in residential dust, but few epidemiological studies have assessed their impact on human health. We measured the levels of 11 PFRs in indoor floor dust and multi‐surface dust in 182 single‐family dwellings in Japan. We evaluated their correlations with asthma and allergies of the inhabitants. Tris(2‐butoxyethyl) phosphate was detected in all samples (median value: 580 μg/g in floor dust, 111 μg/g in multi‐surface dust). Tris(2‐chloro‐iso‐propyl) phosphate (TCIPP) was detected at 8.69 μg/g in floor dust and 25.8 μg/g in multi‐surface dust. After adjustment for potential confounders, significant associations were found between the prevalence of atopic dermatitis and the presence of TCIPP and tris(1,3‐dichloro‐2‐propyl) phosphate in floor dust [per log10‐unit, odds ratio (OR): 2.43 and 1.84, respectively]. Tributyl phosphate was significantly associated with the prevalence of asthma (OR: 2.85 in floor dust, 5.34 in multi‐surface dust) and allergic rhinitis (OR: 2.55 in multi‐surface dust). PFR levels in Japan were high compared with values reported previously for Europe, Asia‐Pacific, and the USA. Higher levels of PFRs in house dust were related to the inhabitants' health status.  相似文献   

8.
We examined microbial correlates of health outcomes in building occupants with a sarcoidosis cluster and excess asthma. We offered employees a questionnaire and pulmonary function testing and collected floor dust and liquid/sludge from drain tubing traps of heat pumps that were analyzed for various microbial agents. Forty‐nine percent of participants reported any symptom reflecting possible granulomatous disease (shortness of breath on exertion, flu‐like achiness, or fever and chills) weekly in the last 4 weeks. In multivariate regressions, thermophilic actinomycetes (median = 529 CFU/m2) in dust were associated with FEV1/FVC [coefficient = ?2.8 per interquartile range change, P = 0.02], percent predicted FEF25–75% (coefficient = ?12.9, P = 0.01), and any granulomatous disease‐like symptom [odds ratio (OR) = 3.1, 95% confidence interval (CI) = 1.45?6.73]. Mycobacteria (median = 658 CFU/m2) were positively associated with asthma symptoms (OR = 1.5, 95% CI = 0.97?2.43). Composite score (median = 11.5) of total bacteria from heat pumps was negatively associated with asthma (0.8, 0.71?1.00) and positively associated with FEV1/FVC (coefficient = 0.44, P = 0.095). Endotoxin (median score = 12.0) was negatively associated with two or more granulomatous disease‐like symptoms (OR = 0.8, 95% CI = 0.67?0.98) and asthma (0.8, 0.67?0.96). Fungi or (1→3)‐β‐D‐glucan in dust or heat pump traps was not associated with any health outcomes. Thermophilic actinomycetes and non‐tuberculous mycobacteria may have played a role in the occupants' respiratory outcomes in this water‐damaged building.  相似文献   

9.
Indoor air pollution has been linked to adverse chronic obstructive pulmonary disease (COPD) health, but specific causative agents have not yet been identified. We evaluated the role of indoor endotoxin exposure upon respiratory health in former smokers with COPD. Eighty‐four adults with moderate to severe COPD were followed longitudinally and indoor air and dust samples collected at baseline, 3 and 6 months. Respiratory outcomes were repeatedly assessed at each time point. The associations between endotoxin exposure in air and settled dust and health outcomes were explored using generalizing estimating equations in multivariate models accounting for confounders. Dust endotoxin concentrations in the main living area were highest in spring and lowest in fall, while airborne endotoxins remained steady across seasons. Airborne and dust endotoxin concentrations were weakly correlated with one another (rs = +0.24, P = 0.005). Endotoxin concentrations were not significantly associated with respiratory symptoms, rescue medication use, quality of life, or severe exacerbations. In vitro whole‐blood assays of the pro‐inflammatory capacity of PM10 filters with and without endotoxin depletion demonstrated that the endotoxin component of indoor air pollution was not the primary trigger for interleukin‐1β release. Our findings support that endotoxin is not the major driver in the adverse effects of indoor PM upon COPD morbidity.  相似文献   

10.
Many volatile organic compounds (VOCs) are classified as known or possible carcinogens, irritants, and toxicants, and VOC exposure has been associated with the onset and exacerbation of asthma. This study characterizes VOC levels in 126 homes of children with asthma in Detroit, Michigan, USA. The total target VOC concentration ranged from 14 to 2274 μg/m3 (mean = 150 μg/m3; median = 91 μg/m3); 56 VOCs were quantified; and d‐limonene, toluene, p, m‐xylene, and ethyl acetate had the highest concentrations. Based on the potential for adverse health effects, priority VOCs included naphthalene, benzene, 1,4‐dichlorobenzene, isopropylbenzene, ethylbenzene, styrene, chloroform, 1,2‐dichloroethane, tetrachloroethene, and trichloroethylene. Concentrations varied mostly due to between‐residence and seasonal variation. Identified emission sources included cigarette smoking, solvent‐related emissions, renovations, household products, and pesticides. The effect of nearby traffic on indoor VOC levels was not distinguished. While concentrations in the Detroit homes were lower than levels found in other North American studies, many homes had elevated VOC levels, including compounds that are known health hazards. Thus, the identification and control of VOC sources are important and prudent, especially for vulnerable individuals. Actions and policies to reduce VOC exposures, for example, sales restrictions, improved product labeling, and consumer education, are recommended.  相似文献   

11.
Exposure to house dust has been associated with asthma in adults, and this is commonly interpreted as a direct immunologic response to dust‐mite allergens in those who are IgE sensitized to house dust‐mite. Mattress house dust‐mite concentrations were measured in a population‐based sample of 2890 adults aged between 27 and 56 years living in 22 centers in 10 countries. Generalized linear mixed models were employed to explore the association of respiratory symptoms with house dust‐mite concentrations, adjusting for individual and household confounders. There was no overall association of respiratory outcomes with measured house dust‐mite concentrations, even in those who reported they had symptoms on exposure to dust and those who had physician‐diagnosed asthma. However, there was a positive association of high serum specific IgE levels to HDM (>3.5 kUA/l) with mattress house dust‐mite concentrations and a negative association of sensitization to cat with increasing house dust‐mite concentrations. In conclusion, there was no evidence that respiratory symptoms in adults were associated with exposure to house dust‐mite allergen in the mattress, but an association of house mite with strong sensitization was observed.  相似文献   

12.
Although the ubiquitous detection of polybrominated diphenyl ether (PBDE) and organophosphate flame retardants (PFRs) in indoor dust has raised health concerns, only very few epidemiological studies have assessed their impact on human health. Inhalation of dust is one of the exposure routes of FRs, especially in children and can be hazardous for the respiratory health. Moreover, PFRs are structurally similar to organophosphate pesticides, which have been associated with allergic asthma. Thus, we investigated whether the concentrations of PFRs and PBDEs in indoor dust are associated with the development of childhood asthma. We selected 110 children who developed asthma at 4 or at 8 years old and 110 matched controls from a large prospective birth cohort (BAMSE – Barn, Allergy, Milieu Stockholm Epidemiology). We analyzed the concentrations of 7 PFRs and 21 PBDEs in dust collected around 2 months after birth from the mother's mattress. The abundance rank in dust was as follows: TBOEP?TPHP>mmp‐TMPP>EHDPHP~TDCIPP>TCEP~TCIPP~BDE‐209?BDE‐99>BDE‐47>BDE‐153>BDE‐183>BDE‐100. There was no positive association between the FRs in mattress dust and the development of childhood asthma. In contrast, dust collected from mattresses of the mothers of children who would develop asthma contained significant lower levels of TPHP and mmp‐TMPP. This study provides data on a wide range of PFRs and PBDEs in dust samples and development of asthma in children.  相似文献   

13.
The relationship between household endotoxin and asthma in children is not clear. To further investigate the relationship between sources of endotoxin and childhood asthma, we conducted a case-control study of children with and without asthma and examined their more frequent household exposures in the home. Children ages 6-13 years with current asthma (n = 70) or wheeze only (n = 19) were sex and age matched (+/-1 year) to 107 controls. Play area and mattress dust were collected for endotoxin analysis. Atopic status was determined by skin prick testing for allergies. A family size of >4 per household was associated with higher endotoxin levels (EU/mg) in the bed dust (P < 0.05). Passive smoking (P < 0.05) and the presence of a cat were associated with higher levels of endotoxin in mattress dust. Endotoxin levels in either the play dust or the bed dust did not differ between cases and controls. Within atopic cases, those with higher endotoxin loads (EU/m2) in bed or play areas were more likely to miss school for chest illness (P < 0.05). In this study, household endotoxin is not a risk factor for current asthma overall but may be associated with increased severity in children with atopic asthma. PRACTICAL IMPLICATIONS: This study did not find that household sources of endotoxin were associated with asthma. However, within atopic asthmatics, asthma severity (as measured by a history of being kept home from school because of a chest illness in the past year) was associated with higher levels of endotoxin in dust from the child's bed. There is a need to further investigate the nature of the relationship between household endotoxin and asthma severity in children which could lead to better management of childhood asthma.  相似文献   

14.
Dampness and visible mold in homes are associated with asthma development, but causal mechanisms remain unclear. The goal of this research was to explore associations among measured dampness, fungal exposure, and childhood asthma development without the bias of culture‐based microbial analysis. In the low‐income, Latino CHAMACOS birth cohort, house dust was collected at age 12 months, and asthma status was determined at age 7 years. The current analysis included 13 asthma cases and 28 controls. Next‐generation DNA sequencing methods quantified fungal taxa and diversity. Lower fungal diversity (number of fungal operational taxonomic units) was significantly associated with increased risk of asthma development: unadjusted odds ratio (OR) 4.80 (95% confidence interval (CI) 1.04–22.1). Control for potential confounders strengthened this relationship. Decreased diversity within the genus Cryptococcus was significantly associated with increased asthma risk (OR 21.0, 95% CI 2.16–204). No fungal taxon (species, genus, class) was significantly positively associated with asthma development, and one was significantly negatively associated. Elevated moisture was associated with increased fungal diversity, and moisture/mold indicators were associated with four fungal taxa. Next‐generation DNA sequencing provided comprehensive estimates of fungal identity and diversity, demonstrating significant associations between low fungal diversity and childhood asthma development in this community.  相似文献   

15.
Nearly half of the world's population depends on biomass fuels to meet domestic energy needs, producing high levels of pollutants responsible for substantial morbidity and mortality. We compare carbon monoxide (CO) and particulate matter (PM2.5) exposures and kitchen concentrations in households with study‐promoted intervention (OPTIMA‐improved stoves and control stoves) in San Marcos Province, Cajamarca Region, Peru. We determined 48‐h indoor air concentration levels of CO and PM2.5 in 93 kitchen environments and personal exposure, after OPTIMA‐improved stoves had been installed for an average of 7 months. PM2.5 and CO measurements did not differ significantly between OPTIMA‐improved stoves and control stoves. Although not statistically significant, a post hoc stratification of OPTIMA‐improved stoves by level of performance revealed mean PM2.5 and CO levels of fully functional OPTIMA‐improved stoves were 28% lower (n = 20, PM2.5, 136 μg/m3 95% CI 54–217) and 45% lower (n = 25, CO, 3.2 ppm, 95% CI 1.5–4.9) in the kitchen environment compared with the control stoves (n = 34, PM2.5, 189 μg/m3, 95% CI 116–261; n = 44, CO, 5.8 ppm, 95% CI 3.3–8.2). Likewise, although not statistically significant, personal exposures for OPTIMA‐improved stoves were 43% and 17% lower for PM2.5 (n = 23) and CO (n = 25), respectively. Stove maintenance and functionality level are factors worthy of consideration for future evaluations of stove interventions.  相似文献   

16.
Most previous research on indoor environments and health has studied school children or occupants in non‐school settings. This investigation assessed building‐related health symptoms and classroom characteristics via telephone survey of New York State school teachers. Participants were asked about 14 building‐related symptoms and 23 classroom characteristics potentially related to poor indoor air quality (IAQ). Poisson regression analysis was used to assess the relationship between these symptoms and each classroom characteristic, controlling for potential confounders. About 500 teachers completed the survey. The most frequently reported classroom characteristics included open shelving (70.7%), food eaten in class (65.5%), dust (59.1%), and carpeting (46.9%). The most commonly reported symptoms included sinus problems (16.8%), headache (15.0%), allergies/congestion (14.8%), and throat irritation (14.6%). Experiencing one or more symptoms was associated most strongly with reported dust (relative risk (RR) = 3.67; 95% confidence interval (CI): 2.62–5.13), dust reservoirs (RR = 2.13; 95% CI: 1.72–2.65), paint odors (RR = 1.73; 95% CI: 1.40–2.13), mold (RR = 1.71; 95% CI: 1.39–2.11), and moldy odors (RR = 1.65 95% CI: 1.30–2.10). Stronger associations were found with increasing numbers of reported IAQ‐related classroom characteristics. Similar results were found with having any building‐related allergic/respiratory symptom. This research adds to the body of evidence underscoring the importance to occupant health of school IAQ.  相似文献   

17.
The envelope of low‐energy buildings is generally constructed with significant amounts of plastics, sealants and insulation materials that are known to contain various chemical additives to improve specific functionalities. A commonly used group of additives are flame retardants to prevent the spread of fire. In this study, decabromodiphenyl ether (BDE‐209) and fourteen emerging brominated flame retardants (BFRs) were analyzed in indoor dust, air and on the window surface of newly built low‐energy preschools to study their occurrence and distribution. BDE‐209 and decabromodiphenyl ethane (DBDPE) were frequently detected in the indoor dust (BDE‐209: <4.1‐1200 ng/g, DBDPE: <2.2‐420 ng/g) and on window surfaces (BDE‐209: <1000‐20 000 pg/m2, DBDPE: <34‐5900 pg/m2) while the other thirteen BFRs were found in low levels (dust: <0.0020‐5.2 ng/g, window surface: 0.0078‐35 pg/m2). In addition, the detection frequencies of BFRs in the indoor air were low in all preschools. Interestingly, the dust levels of BDE‐209 and DBDPE were found to be lower in the environmentally certified low‐energy preschools, which could be attributed to stricter requirements on the chemical content in building materials and products. However, an increase of some BFR levels in dust was observed which could imply continuous emissions or introduction of new sources.  相似文献   

18.
C. An  N. Yamamoto 《Indoor air》2016,26(5):714-723
Indoor visible mold growths are known to be associated with allergies and respiratory illnesses. However, a question remains of their compositions and diversities. Using swab sampling and high‐throughput DNA sequencing, this study analyzed taxonomic compositions and diversities of fungi on indoor surfaces laden with visible mold growths in residential apartments in South Korea. The sequencing results showed low species diversities with Shannon indices ranging from 0.14 to 2.29 (mean = 1.11). Several allergy‐related genera were detected on the same surface, where the most abundant Cladosporium with a mean relative abundance of 41% co‐occurred with less abundant Aspergillus (0.094%), Rhodotorula (6.3%), Cryptococcus (3.7%), Alternaria (4.1%), and Crivellia (17%). β diversity analyses showed significant differences in the fungal communities between enclosed balconies and other indoor areas (< 0.05, ANOSIM), emphasizing a need to sample at multiple indoor locations when assessments are made for indoor visible mold growths. High‐throughput sequencing is powerful in characterizing compositions and diversities of fungal communities. Future studies should examine the relationships between taxonomic compositions and diversities of indoor visible molds and health outcomes of allergies and respiratory illnesses in residential buildings.  相似文献   

19.
Residential endotoxin exposure is associated with protective and pathogenic health outcomes. Evaporative coolers, an energy‐efficient type of air conditioner used in dry climates, are a potential source of indoor endotoxins; however, this association is largely unstudied. We collected settled dust biannually from four locations in homes with evaporative coolers (n=18) and central air conditioners (n=22) in Utah County, Utah (USA), during winter (Jan‐Apr) and summer (Aug‐Sept), 2014. Dust samples (n=281) were analyzed by the Limulus amebocyte lysate test. Housing factors were measured by survey, and indoor temperature and relative humidity measures were collected during both seasons. Endotoxin concentrations (EU/mg) were significantly higher in homes with evaporative coolers from mattress and bedroom floor samples during both seasons. Endotoxin surface loads (EU/m2) were significantly higher in homes with evaporative coolers from mattress and bedroom floor samples during both seasons and in upholstered furniture during winter. For the nine significant season‐by‐location comparisons, EU/mg and EU/m2 were approximately three to six times greater in homes using evaporative coolers. A plausible explanation for these findings is that evaporative coolers serve as a reservoir and distribution system for Gram‐negative bacteria or their cell wall components in homes.  相似文献   

20.
Few prospective studies exist on indoor and outdoor air pollution in relation to adolescent rhinitis. We studied associations between onset and remission of rhinitis among junior high school students in relation to the home and school environment. A 2‐year questionnaire cohort study was performed among 1325 students (11‐15 years) in eight schools in Taiyuan, Northern China. Climate and air pollution were measured by direct reading instruments and passive samplers inside and outside the schools at baseline. Associations were calculated by multilevel logistic regression. Two‐year onset of rhinitis and weekly rhinitis were 26.7% and 13.1%, respectively. RH (P < 0.001), CO2 (P < 0.01) and PM10 (P < 0.01) in the classrooms, PM10 (P < 0.01) and NO2 (P < 0.05) outside the schools, and redecoration (OR = 2.25) and dampness/indoor mold at home (OR = 2.04) were associated with onset of weekly rhinitis. RH (P < 0.05) and CO2 (P < 0.05) in the classroom and dampness/indoor mold (OR = 0.67) and environmental tobacco smoke (ETS) at home (OR = 0.63) reduced remission of rhinitis. In conclusion, dampness/mold and chemical emissions from new materials at home can increase onset of rhinitis and ETS and dampness/mold can reduce the remission. PM10, RH, CO2, and NO2 at school can increase the onset, and RH and CO2 can reduce the remission of rhinitis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号