首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Solar power generation using PV (photovoltaic) technology is a key but still evolving technology with the fastest growing renewable-based market worldwide in the last decade. In this sector with tremendous potential for energy security and economic development, grid-connected PV systems are becoming today the most important application of solar PV generation. Based on this trend, PV system designers require an accurate and reliable tool in order to predict the dynamic performance of grid-tied PV systems at any operating conditions. This will allow evaluating the impact of PV generation on the electricity grids. This paper presents a detailed characterization of the performance and dynamic behavior of a grid-connected PV energy conversion system. To this aim, a flexible and accurate PV simulation and evaluation tool (called PVSET 1.0) is developed. The PV system is modeled, simulated and validated under the MATLAB/Simulink environment. The accuracy of simulation results has been verified using a 250 Wp PV experimental set-up.  相似文献   

2.
The interest for the use of renewable energies has increased, because of the increasing concerns of the environmental problems. Among renewable energies, wind energy is now widely used. Wind turbines based on an asynchronous generator with a wound rotor present the inconvenience of requiring a system of rings and brooms and a multiplier, inferring significant costs of maintenance. To limit these inconveniences, certain manufacturers developed wind turbines based on synchronous machines with large number of pairs of poles coupled directly with the turbine, avoiding using the multiplier. If the generator is equipped with permanent magnets, the system of rings and brooms is eliminated. The control of the permanent magnet synchronous generator (PMSG) can be affected with the implementation of various techniques of control. This paper presented a new approach mainly based on the control strategy of power production system based on the PMSG. In fact, a mathematical model that simulates the Matlab chain was established with the introduction of control techniques, such as direct control of the torque (DTC) to control the load side converter (LSC), the control of the speed of the turbine and the DC-bus voltage ensured by PI regulators. To show the performance of the correctors used, some simulation results of the system were presented and analyzed.  相似文献   

3.
This paper aims to explore the possibility of synchronous generator (SG) based wind energy generation system feeding an isolated load using a latest power transmission technology i.e. variable frequency transformer (VFT). The proposed configuration does not employ any power electronics based interface as in conventional SG based stand-alone wind energy conversion systems (SWECS). For analysis, the simulation models of proposed configuration as well as conventional configuration have been developed under MATLAB-Simulink environment. A series of studies on power fed from the SG to the different loads at various SG input speeds has been carried out with the developed models. Further to analyze the effectiveness of the proposed method; the efficiency, total harmonic distortion (THD) of output voltage and THD of output current of the proposed method have been compared with those of the conventional method. From obtained results, it is observed that the proposed method is simple and does not produce harmonics. Moreover to validate the proposed scheme, an experimental analysis has been carried out. Further, the cost analysis of both systems has also been carried out. From the cost analysis, it is observed that the proposed system is cheaper than the conventional system.  相似文献   

4.
Frequency regulation in a generation mix having large wind power penetration is a critical issue, as wind units isolate from the grid during disturbances with advanced power electronics controllers and reduce equivalent system inertia. Thus, it is important that wind turbines also contribute to system frequency control. This paper examines the dynamic contribution of doubly fed induction generator (DFIG)-based wind turbine in system frequency regulation. The modified inertial support scheme is proposed which helps the DFIG to provide the short term transient active power support to the grid during transients and arrests the fall in frequency. The frequency deviation is considered by the controller to provide the inertial control. An additional reference power output is used which helps the DFIG to release kinetic energy stored in rotating masses of the turbine. The optimal speed control parameters have been used for the DFIG to increases its participation in frequency control. The simulations carried out in a two-area interconnected power system demonstrate the contribution of the DFIG in load frequency control.  相似文献   

5.
In this paper, critical review of various work done in the areas of wind energy resource, modelling of wind energy conversion system (WECS) and issues regarding wind power integration into the grid are presented with the aim of examining the development, progress, achievements and direction of research. Some of the findings show that every site is unique; therefore, no generic conclusion can be drawn with regards to wind characteristics and the wind power potential of locations. The study also reveals that there is no single model of WECS. The model to be adopted will depend on the problem to be solved. This paper is useful in providing background details for wind turbine designers, researchers and practical engineers who are new in the field of wind energy.  相似文献   

6.
The use of wind energy by means of its conversion to electricity involves a number of constrains such as economic, environmental, technical, legal, social and institutional requirements. Planning for wind energy should solve these issues in the planning process by encouraging opportunities and discouraging constraints associated with the use of wind energy. The opportunities and constraints significant at the regional level (i.e. approximately 10,000 km2) were identified, and a systematic method was developed to select sites for large WECS by incorporating the identified factors. These factors include: wind resource, proximity to load centres, proximity to tie-in points, and exclusive land-use areas. The developed method was applied to the western Massachusetts region, and the first results of the study have been acquired.  相似文献   

7.
Wind–PV–diesel hybrid power generation system technology is a promising energy option since it provides opportunities for developed and developing countries to harness naturally available, inexhaustible and pollution-less resources. The aim of this study is to assess the techno-economic feasibility of utilizing a hybrid wind–PV–diesel power system to meet the load of Al Hallaniyat Island. Hybrid Optimization Model for Electric Renewables software has been employed to carry out the present study. The simulation results indicate that the cost of generating energy (COE) is $0.222 kWh?1 for a hybrid system composed of a 70 kW PV system, 60 kW wind turbine and batteries together with a 324.8 kW diesel system. Moreover, using the same system but without batteries will increase the COE to $0.225 kWh?1, the fuel consumption, the excess energy and the total operating hours for the diesel generators. The PV–wind hybrid option is techno-economically viable for rural electrification.  相似文献   

8.
This paper proposes and validates an efficient, generic and computationally simple dynamic model for the conversion of the wind speed at hub height into the electrical power by a wind turbine. This proposed wind turbine model was developed as a first step to simulate wind power time series for power system studies. This paper focuses on describing and validating the single wind turbine model, and is therefore neither describing wind speed modeling nor aggregation of contributions from a whole wind farm or a power system area. The state‐of‐the‐art is to use static power curves for the purpose of power system studies, but the idea of the proposed wind turbine model is to include the main dynamic effects in order to have a better representation of the fluctuations in the output power and of the fast power ramping especially because of high wind speed shutdowns of the wind turbine. The high wind speed shutdowns and restarts are represented as on–off switching rules that govern the output of the wind turbine at extreme wind speed conditions. The model uses the concept of equivalent wind speed, estimated from the single point (hub height) wind speed using a second‐order dynamic filter that is derived from an admittance function. The equivalent wind speed is a representation of the averaging of the wind speeds over the wind turbine rotor plane and is used as input to the static power curve to get the output power. The proposed wind turbine model is validated for the whole operating range using measurements available from the DONG Energy offshore wind farm Horns Rev 2. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

9.
In order to study the impact of a wind farm on the dynamics of the power system, a significant issue is to develop appropriate equivalent models that allow characterizing the dynamics of all individual wind turbine generators (WTGs) composing the park. In this sense, with the advance of power electronics, direct-driven permanent magnet synchronous generators (PMSGs) have drawn increased interest to wind turbine manufacturers due to their advantages over other variable-speed WTGs. These include the possibility of multi-pole design with a gearless construction that offers slow speed operation and reduced maintenance since no brushes are used, elimination of the excitation system, full controllability for maximum wind power extraction and grid interface, and easiness in accomplishing fault-ride through and grid support. In this way, this paper presents a comprehensive dynamic equivalent model of a wind farm with direct-driven PMSG wind turbines using full-scale converters and its control scheme. The proposed simplified modelling is developed using the state-space averaging technique and is implemented in the MATLAB/Simulink environment. The dynamic performance of the wind farm and its impact on the power system operation is evaluated using the phasor simulation method.  相似文献   

10.
A wind gust can cause severe dynamic conditions that affect the operational behavior of the whole doubly fed induction generator (DFIG) wind energy conversion system and, as a result, the quality of power exchanged with the grid. In addition, it can cause great disturbances to critical system's variables with possible damages to the system's construction—to mechanical or electrical part. The knowledge of DFIG reaction in such conditions is useful for both protection issues and the risk assessment concerning system's tolerance, maintenance costs and revenue losses, because of the disconnection from the grid. In this paper, a quantitative and qualitative behavior analysis of a 2 MW DFIG wind energy conversion system under a wind gust and converter faults, which has been carried out via simulation, is presented. The pitch controller parameters impact to its behavior, when a gust appears, has been investigated. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
This paper investigates an analytical approach for the reliability modeling of doubly fed induction generator (DFIG) wind turbines. At present, to the best of the authors’ knowledge, wind speed and wind turbine generator outage have not been addressed simultaneously. In this paper, a novel methodology based on the Weibull- Markov method is proposed for evaluating the probabilistic reliability of the bulk electric power systems, including DFIG wind turbines, considering wind speed and wind turbine generator outage. The proposed model is presented in terms of appropriate wind speed modeling as well as capacity outage probability table (COPT), considering component failures of the wind turbine generators. Based on the proposed method, the COPT of the wind farm has been developed and utilized on the IEEE RBTS to estimate the well-known reliability and sensitive indices. The simulation results reveal the importance of inclusion of wind turbine generator outage as well as wind speed in the reliability assessment of the wind farms. Moreover, the proposed method reduces the complexity of using analytical methods and provides an accurate reliability model for the wind turbines. Furthermore, several case studies are considered to demonstrate the effectiveness of the proposed method in practical applications.  相似文献   

12.
根据光伏电池的数学模型在MATLAB上建立了仿真模块,同时利用MATLAB里已有的异步风力发电机模型及蓄电池模型构建了风光互补的微电网系统。采用直流微电网与交流微电网混合的方式对直流负荷和交流负荷供电,在交流侧,仅采用一个独立的公共DC/AC变换器,在满足了负荷需求的同时节约了变换器资源。针对微电网的并网运行模式,建立了PQ控制模型;针对微电网的孤岛运行模式,采用了V/f控制方法,在电感电流内环电压外环的基础上,加入了负载扰动前馈补偿,同时,对逆变器连续状态空间表达式进行离散化,建立了控制模型。最后,通过对微电网并网运行和孤岛运行时的实例仿真,验证了控制方法的可行性及有效性。  相似文献   

13.
Kai Liao  Yao Wang  Zhengyou He 《风能》2018,21(3):151-162
This paper proposes a novel control strategy for doubly fed induction generator (DFIG)‐based wind energy conversion system to investigate the potential of enhancing the stability of wind energy transmission system, a synchronous generator weakly integrated to a power system with a DFIG‐based wind farm. The proposed approach uses state feedback to exactly linearize the nonlinear wind energy transmission system from control actions (active power and reactive power control order of DFIG) to selected outputs (power angle and voltage behind transient resistance of synchronous generator) at first. Then, on account of the linearized subsystem, the stability enhancement controller is designed based on linear quadratic regulator algorithm to contribute adequate damping characteristics to oscillations of the synchronous generator system under various operation points. The proposed control strategy successfully deals with the nonlinear behaviors exist from the inputs to outputs and improve the robustness with respect to the variation of system operation points. Furthermore, not only the rotor angle stability but also the voltage stability is enhanced by using the proposed control strategy. The simulation results carried on the studied system verify the effectiveness of the proposed control strategy of wind energy conversion system for system stability enhancement and the robustness against various system operation points.  相似文献   

14.
More and more conversion systems have been proposed to capture wind energy in order to produce electrical power. In this paper, an energetic macroscopic representation is used to describe such systems composed of very different parts. This representation yields the simulation model of the overall system based on energetic considerations. Moreover, a control structure can be deduced from this representation by simple inversion rules. Hence, the different strategies of wind turbine management can be shown by the theoretical control structure. In order to illustrate this modelling and control methodology a 750 kW wind energy conversion system is studied and simulated.  相似文献   

15.
This paper presents modeling and control of a photovoltaic generator (PVG) connected to the grid. The parameters of the PVG have been identified in previous work (series and parallel resistance, reverse saturation current and thermal voltage) using Newton-Raphston and the gradient algorithm. The electrical energy from a PVG is transferred to the grid via two static converters (DC/DC and DC/AC). The objective of the proposed control strategy is to maximize energy captured from the PVG. The adapted control law for extracting maximum power from the PVG is based on the incremental conductance algorithm. The developed algorithm has the capability of searching the maximum photovoltaic power under variable irradiation and temperature. To control the DC/AC inverter, an intelligent system based on two structures is constructed: a current source control structure and a voltage source control structure. The system has been validated by numerical simulation using data obtained from the PVG installed in the laboratory research (INSAT, Tunisia).  相似文献   

16.
针对在风力发电机上具有广泛应用前景的飞轮储能技术,设计了储能系统的矢量控制器硬件电路及实验平台、电机控制系统的主电路和驱动电路、DSP主控板、电压及电流信号的采集系统等。基于矢量控制原理,进行了电机控制系统仿真研究。仿真结果表明,该系统能够精确地实现对电机速度的跟踪。在飞轮储能与风力发电模拟系统的试验中,为了验证控制系统的响应速度及稳态精度,利用交流电网对飞轮充电,有效地实现了飞轮与电机的耦合及飞轮能量的快速存储和释放。  相似文献   

17.
In this paper, a doubly fed variable speed wind induction generator connected to the grid associated to a flywheel energy storage system (FESS) is investigated. The dynamic behaviour of a wind generator, including the models of the wind turbine (aerodynamic), the doubly fed induction generator (DFIG), a ac/ac direct converter, the converter control (algorithm of VENTURINI) and the power control of this system, is studied. Also investigated is a control method of the FESS system, which consists of the classical squirrel-cage induction machine supplied off the variable speed wind generator (VSWG) through a rectifier–inverter cascade arrangement. Simulation results obtained on the basis of the dynamic models of the wind generator are presented, for different operating points, to demonstrate the performance of the proposed system.  相似文献   

18.
Over the last few decades, doubly fed induction generators (DFIG) have become one of the most successful and preferred types of wind energy generators (WEG). The DFIG has the advantages of a wide range of speed operations, a high efficiency, and partial rated converters. However, direct coupling of the stator with the grid makes the system more prone to grid disturbances. The consequences of grid disturbances, such as a rotor overcurrent, stator overcurrent, electromagnetic torque oscillations, and direct current (DC) link overvoltage, are the predominant considerations that affect the rotor circuit, stator circuit, mechanical components, and DC‐link capacitor of the DFIG, respectively. These uncertainties affect the operation of the generator and may lead to the generator to be shutdown. In this paper, a novel position for the placement of a passive resistive element (PRE) is illustrated. This position of the PRE placement is compared with all other possible locations for the PRE. The different locations for PRE placement are the stator side, rotor side, across the DC‐link capacitor, and between the rotor side converter (RSC) and grid side converter (GSC). This paper aims to determine a cost‐effective solution among all possible locations of the PRE placement. The novel position of the PRE, ie, between the RSC and GSC, is the best position among the other possible locations of the PRE, when the performance, cost, and loss are taken into consideration. The effectiveness of the PRE is further compared with the resistive‐type superconducting fault current limiter (R‐SFCL). The PRE performs better and has a lower cost than the R‐SFCL.  相似文献   

19.
This paper describes a hybrid energy system consisting of a 5 kW wind turbine and a fuel cell system. Such a system is expected to be a more efficient, zero emission alternative to wind diesel system. Dynamic modeling of various components of this isolated system is presented. Selection of control strategies and design of controllers for the system is described. Simnon is used for the simulation of this highly nonlinear system. Transient responses of the system for a step change in the electrical load and wind speed are presented. System simulation results for a pre-recorded wind speed data indicates the transients expected in such a system. Design, modeling, control and limitations of a wind fuel cell hybrid energy system are discussed.  相似文献   

20.
Grid‐connected photo voltaic (PV) systems are being developed very fast and systems from a few kW to tenths of a MW are now in operation. As an important source of distributed generation (DS) the PV systems need to comply with a series of standard requirements in order to ensure the safety and the seamless transfer of the electrical energy to the grid. Multilevel voltage source converters (VSC) is a heart of the PV system and are emerging as an important power converter options for low, medium, and high‐power applications. These VSCs have bought numerous advantages, especially in renewable energy systems such as PV and wind energy systems. In this article, several topologies of VSCs, which brings together some concepts from traditional converters and multi‐level converters, are presented. Also, several control strategies for controlling current, voltage, active power and reactive power have also been reviewed. Various topologies with their technical aspects have been reviewed and the best suitable topology and control scheme for grid connected PV and wind energy systems has been suggested. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号