首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 734 毫秒
1.
The energy and exergy analyses of the drying process of olive mill wastewater (OMW) using an indirect type natural convection solar dryer are presented. Olive mill wastewater gets sufficiently dried at temperatures between 34 °C and 52 °C. During the experimental process, air relative humidity did not exceed 58%, and solar radiation ranged from 227 W/m2 to 825 W/m2. Drying air mass flow was maintained within the interval 0.036–0.042 kg/s. Under these experimental conditions, 2 days were needed to reduce the moisture content to approximately one-third of the original value, in particular from 3.153 gwater/gdry matter down to 1.000 gwater/gdry matter.Using the first law of thermodynamics, energy analysis was carried out to estimate the amounts of energy gained from solar air heater and the ratio of energy utilization of the drying chamber. Also, applying the second law, exergy analysis was developed to determine the type and magnitude of exergy losses during the solar drying process. It was found that exergy losses took place mainly during the second day, when the available energy was less used. The exergy losses varied from 0 kJ/kg to 0.125 kJ/kg for the first day, and between 0 kJ/kg and 0.168 kJ/kg for the second. The exergetic efficiencies of the drying chamber decreased as inlet temperature was increased, provided that exergy losses became more significant. In particular, they ranged from 53.24% to 100% during the first day, and from 34.40% to 100% during the second.  相似文献   

2.
The present study deals with heat storage performance investigation of integrated solar pond and collector system. In the experimental work, a cylindrical solar pond system (CSPS) with a radius of 0.80 m and a depth of 2.0 m and four flat plate collectors dimensions of 1.90 m × 0.90 m was built in Cukurova University in Adana, Turkey. The CSPS was filled with salty water of various densities to form three salty water zones (Upper Convective Zone, Non-Convective Zone and Heat Storage Zone). Heat energy collected by collectors was transferred to the solar pond storage zone by using a heat exchanger system which is connected to the solar collectors. Several temperature sensors connected to a data acquisition system were placed vertically inside the CSPS and at the inlet and outlet of the heat exchanger. Experimental studies were performed using 1, 2, 3 and 4 collectors integrated with the CSPS under approximately the same condition. The integrated solar pond efficiencies were calculated experimentally and theoretically according to the number of collectors. As a result, the experimental efficiencies are found to be 21.30%, 23.60%, 24.28% and 26.52%; the theoretical efficiencies to be 23.42%, 25.48%, 26.55% and 27.70% for 1, 2, 3 and 4 collectors, respectively. Theoretical efficiencies were compared with the experimental results and hence a good agreement is found between experimental and theoretical efficiency profiles.  相似文献   

3.
Convective solar drying experiments in thin layers of Citrus aurantium leaves grown in Marrakech, morocco, were conducted. An indirect forced convection solar dryer consisting of a solar air collector, an auxiliary heater, a circulation fan and a drying cabinet is used for the experiments. The air temperature was varied from 50 to 60 °C; the relative humidity from 41% to 53%; and the drying air flow rate from 0.0277 to 0.0833 m3/s. Thirteen statistical models, which are semi-theoretical and/or empirical, were tested for fitting the experimental data. A nonlinear regression analysis using a statistical computer program was used to evaluate the constants of the models. The Midilli–Kucuk drying model was found to be the most suitable for describing the solar drying curves of Citrus aurantium leaves with a correlation coefficient (r) of 0.99998, chi-square (χ2) of 4.664 × 10−6 and MBE of 4.8381 × 10−4.  相似文献   

4.
In this study, performance assessment of an integrated cooling plant having both free cooling system and solar powered single-effect lithium bromide–water absorption chiller in operation since August 2002 in Oberhausen, Germany, was performed. A floor space of 270 m2 is air-conditioned by the plant. The plant includes 35.17 kW cooling (10-RT) absorption chiller, vacuum tube collectors’ aperture area of 108 m2, hot water storage capacity of 6.8 m3, cold water storage capacity of 1.5 m3 and a 134 kW cooling tower. The results show that free cooling in some cooling months can be up to 70% while it is about 25% during the 5 years period of the plant operation. For sunny clear sky days with equal incident solar radiation, the daily solar heat fraction ranged from 0.33 to 0.41, collectors’ field efficiency ranged from 0.352 to 0.492 and chiller COP varies from 0.37 to 0.81, respectively. The monthly average value of solar heat fraction varies from 31.1% up to 100% and the five years average value of about 60%. The monthly average collectors’ field efficiency value varies from 34.1% up 41.8% and the five-year average value amounts about 28.3%. Based on the obtained results, the specific collector area is 4.23 (m2/kWcold) and the solar energy system support of the institute heating system for the duration from August 2002 to November 2007 is 8124 kWh.  相似文献   

5.
Concentrating solar thermal systems offer a promising method for large scale solar energy collection. Although concentrating collectors are generally thought of as large-scale stand-alone systems, there is a huge opportunity to use novel concentrating solar thermal systems for rooftop applications such as domestic hot water, industrial process heat and solar air conditioning for commercial, industrial and institutional buildings. This paper describes the thermal performance of a new low-cost solar thermal micro-concentrating collector (MCT), which uses linear Fresnel reflectors, and is designed to operate at temperatures up to 220 °C. The modules of this collector system are approximately 3 m long by 1 m wide and 0.3 m high. The objective of the study is to optimise the design to maximise the overall thermal efficiency. The absorber is contained in a sealed enclosure to minimise convective losses. The main heat losses are due to natural convection inside the enclosure and radiation heat transfer from the absorber tube. In this paper we present the results of a computational and experimental investigation of radiation and convection heat transfer in order to understand the heat loss mechanisms. A computational model for the prototype collector has been developed using ANSYS–CFX, a commercial computational fluid dynamics software package. The numerical results are compared to experimental measurements of the heat loss from the absorber, and flow visualisation within the cavity. This paper also presents new correlations for the Nusselt number as a function of Rayleigh number.  相似文献   

6.
《Applied Thermal Engineering》2007,27(2-3):442-449
Solar energy integrated with the building is an important approach for the synchronous development of solar energy and architecture. The energy gain of the solar collector integrated with the pitched roof has been greatly influenced by the roof azimuth and tilted angle. Investment cost of the collectors is mainly decided by the size of the collector area. Accordingly, it is significant for solar building design to economically determinate the area compensation of the solar collector at different azimuth and tilted angles. Take Kunming and Beijing as examples, area compensation for the flat-plate tube-fin solar collector used in southern regions and the evacuated tube collector with cylindrical absorbers used in northern regions in China have been theoretically calculated. The results to some extent show that the daily horizontal solar radiation, ambient temperature, the azimuth and tilted angle of the collector integrated into the roof have an influence on the area compensation. The azimuth angle and tilted angle of the roof are the main factors that influence the A/A0, which is defined as the collector area ratio of the non-south-facing collectors to the south-facing ones with the optimal tilted angle. Comparative studies found that the range of A/A0 for the evacuated tube collector used in the northern regions is close to that for the flat-plate tube-fin solar collector used in the southern regions. When the pitched roof tilted angle β  [25°, 45°] and the azimuth angle ∣γ  30°, the collectors can intercept a lot of solar radiant-energy. Considering the economic situations of the ordinary consumers in China, the optimal area compensation A/A0  1.30 is recommended in this paper.  相似文献   

7.
This paper presents an overview of the parabolic-trough collectors that have been built and marketed during the past century, as well as the prototypes currently under development. It also presents a survey of systems which could incorporate this type of concentrating solar system to supply thermal energy up to 400 °C, especially steam power cycles for electricity generation, including examples of each application.  相似文献   

8.
The work presented in this article aims to investigate a PV/T hybrid solar window on a system level. A PV/T hybrid is an absorber on which solar cells have been laminated. The solar window is a PV/T hybrid collector with tiltable insulated reflectors integrated into a window. It simultaneously replaces thermal collectors, PV-modules and sunshade. The building integration lowers the total price of the construction since the collector utilizes the frame and the glazing in the window. When it is placed in the window a complex interaction takes place. On the positive side is the reduction of the thermal losses due to the insulated reflectors. On the negative side is the blocking of solar radiation that would otherwise heat the building passively. This limits the performance of the solar window since a photon can only be used once. To investigate the sum of such complex interaction a system analysis has to be performed. In this paper results are presented from such a system analysis showing both benefits and problems with the product. The building system with individual solar energy components, i.e. solar collector and PV modules, of the same size as the solar window, uses 1100 kW h less auxiliary energy than the system with a solar window. However, the solar window system uses 600 kW h less auxiliary energy than a system with no solar collector.  相似文献   

9.
Chile is expecting a 5.4% growth in energy consumption per year until 2030, requiring new and better solutions for the upward trend of its electricity demand. This state leads to select and study one of the potential alternatives for electricity generation: concentrated solar power (CSP) plants. Such renewable technology found in Chile a very favorable condition. Recent researches indicate Atacama Desert as one of the best regions for solar energy worldwide, having an average radiation higher than in places where CSP plants are currently implemented, e.g. Spain and USA. The aim of this study is to present an analysis of levelized energy cost (LEC) for different power capacities of CSP plants placed in distinct locations in northern Chile. The results showed that CSP plants can be implemented in Atacama Desert with LECs around 19 ¢US$/kWh when a gas-fired backup and thermal energy storage (TES) systems are fitted. This value increases to approximately 28 ¢US$/kWh if there is no backup system.  相似文献   

10.
The thin layer solar drying of mango slices of 8 mm thick was simulated and experimented using a solar dryer designed and constructed in laboratory. Under meteorological conditions of harvest period of mangoes, the results showed that 3 “typical days” of drying were necessary to reach the range of preservation water contents. During these 3 days of solar drying, 50%, 40% and 5% of unbound water were eliminated, respectively, at the first, second and the third day. The final water content obtained was about 16 ± 1.33% d.b. (13.79% w.b.). This final water content and the corresponding water activity (0.6 ± 0.02) were in accordance with previous work. The drying rates with correction for shrinkage and the critical water content were experimentally determined. The critical water content was close to 70% of the initial water content and the drying rates were reduced almost at 6% of their maximum value at night. The thin layer drying model made it possible to simulate suitably the solar drying kinetics of mango slices with a correlation coefficient of r2 = 0.990. This study thus contributed to the setting of solar drying time of mango and to the establishment of solar drying rates' curves of this fruit.  相似文献   

11.
Ian Edmonds 《Renewable Energy》2009,34(4):1100-1105
This paper describes a solar powered reciprocating engine based on the use of a tethered hot air balloon fuelled by hot air from a glazed collector. The basic theory of the balloon engine is derived and used to predict the performance of engines in the 10 kW to 1 MW range. The engine can operate over several thousand metres altitude with thermal efficiencies higher than 5%. The engine thermal efficiency compares favorably with the efficiency of other engines, such as solar updraft towers, that also utilize the atmospheric temperature gradient but are limited by technical constraints to operate over a much lower altitude range. The increased efficiency allows the use of smaller area glazed collectors. Preliminary cost estimates suggest a lower $/W installation cost than equivalent power output tower engines.  相似文献   

12.
In the present study the chevron pattern of fold structure produced using a recently developed continuous folding technique is considered for the first time in the application of solar air collectors. An experimental study of two types of flat bed solar air collectors, with flat plate and chevron pattern absorbers, is carried out to investigate their performance over a wide range of operating conditions. A theoretical comparison between flat plate, v-grooved and chevron pattern absorbers is also presented. Under the considered configurations and operating conditions, the chevron pattern absorber is found to be the most efficient and that the flat plate absorber the least efficient. The chevron pattern is found to have higher performance, reaching up to 20% improvement in thermal efficiency and an increase of 10 °C in outlet temperature at some ranges of mass flow rates.  相似文献   

13.
Institutional buildings contain different types of functional spaces which require different types of heating, ventilating and air conditioning (HVAC) systems. In addition, institutional buildings should be designed to maintain an optimal indoor comfort condition with minimal energy consumption and minimal negative environmental impact. Recently there has been a significant interest in implementing desiccant cooling technologies within institutional buildings. Solar desiccant cooling systems are reliable in performance, environmentally friendly and capable of improving indoor air quality at a lower cost. In this study, a solar desiccant cooling system for an institutional building in subtropical Queensland (Australia) is assessed using TRNSYS 16 software. This system has been designed and installed at the Rockhampton campus of Central Queensland University. The system's technical performance, economic analysis, energy savings, and avoided gas emission are quantified in reference to a conventional HVAC system under the influence of Rockhampton's typical meteorological year. The technical and economic parameters that are used to assess the system's viability are: coefficient of performance (COP), solar fraction, life cycle analysis, payback period, present worth factor and the avoided gas emission. Results showed that, the installed cooling system at Central Queensland University which consists of 10 m2 of solar collectors and a 0.400 m3 of hot water storage tank, achieved a 0.7 COP and 22% of solar fraction during the cooling season. These values can be boosted to 1.2 COP and 69% respectively if 20 m2 of evacuated tube collector's area and 1.5 m3 of solar hot water storage volume are installed.  相似文献   

14.
《Energy Conversion and Management》2005,46(15-16):2530-2552
This paper is concerned with the energy and exergy analyses of the single layer drying process of potato slices via a cyclone type dryer. Using the first law of thermodynamics, an energy analysis was performed to estimate the ratios of energy utilization. An exergy analysis was accomplished to determine the location, type and magnitude of the exergy losses during the drying process by applying the second law of thermodynamics. It was concluded that the exergy losses took place mostly in the 1st tray where the available energy was less utilized during the single layer drying process of potato slices. It is emphasized that the potato slices are sufficiently dried in the ranges between 60 and 80 °C and 20–10% relative humidity at 1 and 1.5 ms−1 of drying air velocity during 10–12 h despite the exergy losses of 0–1.796 kJ s−1.  相似文献   

15.
This research presents the MODERGIS Integrated Simulation's Platform as a tool to promote and develop renewable energy plans under sustainability criteria, in order to increment the participation of renewable technologies in the national “energy mix” and shows an application to Colombia as a case study. Potential zones of solar and wind energy and productive areas were determined for bio-energies, by means of a geographical information system which simulated energy scenarios influenced by climatic phenomena up to the year 2030. Results yield potentials of 26,600 MW in wind energy and 350,000 MW in solar energy. Bioenergy potentiates in a sustainable way of 366,310 km per biomass, 291,486 km in African palm, 9,667 km in sugar cane. These scenarios were simulated in a supply/demand with time horizons up until 2030, including an analysis of the effects on the energy systems of the El Niño Southern Oscillation atmospheric component (ENSO). Finally, in order to obtain an appropriate mix of renewable sources that could be introduced in the national energy mix, the Multi-Criteria Analysis method VIKOR was used, allowing to perform performing 5151 possible combinations of renewable projects; the optimal selection corresponds to 600 MW from wind power, 740 MW solar photovoltaic and 660 MW solar thermoelectric. Giving these results to the new scene allowed for incrementing the participation of renewable technologies up to a 0.23% in the current year and up to a 7% of the “energy mix” in the year 2030.  相似文献   

16.
《Energy Conversion and Management》2005,46(15-16):2439-2454
In this paper, an attempt was made to evaluate the convective heat transfer coefficient during drying of various crops and to investigate the influences of drying air velocity and temperature on the convective heat transfer coefficient. Drying was conducted in a convective cyclone type dryer at drying air temperatures of 60, 70 and 80 °C and velocities of 1 and 1.5 m/s using rectangle shaped potato and apple slices (12.5 × 12.5 × 25 mm) and cylindrical shaped pumpkin slices (35 × 5 mm). The temperature changes of the dried crops and the temperature of the drying air were measured during the drying process. It was found that the values of convective heat transfer coefficient varied from crop to crop with a range 30.21406 and 20.65470 W/m2 C for the crops studied, and it was observed that the convective heat transfer coefficient increased in large amounts with the increase of the drying air velocity but increased in small amounts with the rise of the drying air temperature.  相似文献   

17.
In this research, a solar air heater is designed, fabricated and its performance is assessed in the perspective of an emerging/developing country with a huge energy demand like Bangladesh. The winter season (mid-November–mid-February) of the country characterizes by low temperatures, cool air blowing from the west or northwest, clear sky and meager rainfall. Minimum temperature in the extreme northwest in late December and early January sometimes reaches 3 °C and day length is about 10 h. The shortness of winter days can be compensated by reducing the heat loss during long nights. The solar air heater is constructed to prevent as much heat loss as possible. In other words, the heating of air is accomplished by maximizing light gain and minimizing heat loss. It is observed that the fabricated solar air heater is working efficiently. The maximum room temperature and the temperature difference from ambient are 45.5 °C and 12.25 °C for forced circulation and 41.75 °C and 8.5 °C for natural circulation respectively. The experimental outlet temperatures have been compared with that of theoretical values. Due to its low-cost and simple technology, it is affordable in all aspects, viz. of cost, operation and maintenance by the typical people of Bangladesh.  相似文献   

18.
When using passive solar heating systems, it is necessary to have available an Equator-facing facade on which to install them. Rooms without such a facade are not the best option for conventional passive solar heating systems. SIRASOL is a passive solar radiant system that captures solar energy and is to be installed in the ceiling of the room. This room must not necessarily have an Equator-facing facade. Solar energy heats up a metal sheet, which is the radiant panel, which transfers heat by long-wave radiation to the room below it. This paper presents a mathematical model and a sensitivity analysis. The mathematical model was used to analyze radiant panel temperature, radiant mean temperature, operative temperature and panel surface area. Results of the sensitivity study showed that when solar radiation rises (from 200 to 800 W) panel temperature increases from 36 °C to 92 °C, whereas variations in outside and inside air temperature have a negligible impact on the panel temperature. Thus, the use of SIRASOL is possible in locations with clear skies. Moreover, from panel temperature values we calculated mean radiant temperature and thereby the room’s operative temperature, which is proportional to the radiant panel area. When this area is 50% of the room’s floor area, operative temperature grows 3.1 °C higher than inside air temperature when solar radiation is 500 W/m2. The analysis shows that a thermal asymmetry appears only when SIRASOL’s surface area to floor area ratio is higher than 32%.  相似文献   

19.
Photovoltaic-thermal collectors (or PV-T collector) are hybrid collectors where PV modules are integrated as an absorber of a thermal collector in order to convert solar energy into electricity and usable heat at the same time. In most of the cases, the hybrid collectors are made by the superposition of a PV module on the thermal absorber of a solar collector. In this paper, the approach is different and is to analyze thermal and optical properties related to both PV and solar thermal functions in order to identify an optimum combination leading to a maximum overall efficiency. Indeed, although these two functions do not exploit the same range of radiation wavelengths, thermal and PV functions are not so complementary due to photo-conversion thermal dependency. In this context, an alternative PV cell lamination has been developed with increased optical and thermal performance. The improvements were evaluated around 2 mA/cm2 in terms of current density in comparison to a standard module encapsulation. Based on this technique, a real size PV-T module has been built and tested at Fraunhofer solar test facilities. The results show a global efficiency of the PV-T collector above 87% (79% thermal efficiency plus 8.7% electrical efficiency, based on the absorber area).  相似文献   

20.
This paper describes the experimental studies carried out to test thermal cycling of a real-scale PCM–air heat exchanger at ambient temperatures. To achieve this goal an experimental setup previously designed and used for testing real-scale prototypes of PCM–air heat exchangers is modified. The PCM used is commercially available, organic, and paraffin based. The total energy exchanged during melting and solidification, as well as the time elapsed until total melting/solidification are determined from the power curves experimentally obtained. The influence of the inlet air temperature and air flow is studied, and results show that the continuous thermal cycling of the unit is a repetitive process: running experiments with similar conditions leads to the same thermal behavior, no degradation in the PCM properties is noticed. Pressure drop is measured for different air flows. Depending on the inlet air temperature, full solidification of the PCM could be achieved in less than 3 h for an 8 °C temperature difference between the inlet air and the average phase change of the PCM. Average thermal powers of up to 4.5 kW and 3.5 kW for 1 h are obtained for melting and solidification stages, respectively. An empirical model is developed from the experimental results, which could be a useful designing tool for applications that use such technology: green housing, curing and drying processes, plant production, HVAC, and free-cooling.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏