首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 406 毫秒
1.
Carbonaceous characteristics of atmospheric particulate matter in Hong Kong   总被引:1,自引:0,他引:1  
To determine the characteristic of carbonaceous species in atmospheric particles in Hong Kong, PM10 and PM2.5 samples were collected using high volume (hi-vol.) air samplers from November 2000 to February 2001. The organic carbon (OC) and elemental carbon (EC) were analyzed by the selective thermal manganese dioxide oxidation (TMO) method. The ratios of PM2.5/PM10 mass ratios were 0.61, 0.78 and 0.53 for particulate matter collected at PolyU station (PolyU, near a major traffic corridor), Kwun Tong station (KT, mixed residential/commercial/industrial) and the Hok Tsui background station (HT), respectively. These results indicate that the PM2.5 concentrations constitute the majority of the PM10 concentrations, especially in urban and industrial areas of Hong Kong. The average concentrations at the three sites ranged from 73.11 to 83.52 μg/m3 for PM10 and from 42.37 to 57.38 μg/m3 for PM2.5. The highest daily mass concentrations of PM10 and PM2.5 were 125.89 μg/m3 and 116.89 μg/m3 at KT, respectively. The correlation between PM10 and PM2.5 was high at KT and HT (r>0.9, P<0.01). This means that the sources of PM10 and PM2.5 may be the same at both sites. The highest mean concentration of OC (12.02 μg/m3) and EC (6.86 μg/m3) in PM10 was found at the PolyU among the three sites. For PM2.5, the highest mean concentration of OC (10.16 μg/m3) was at KT while the highest mean concentration of EC (7.95 μg/m3) was at PolyU. However, the background concentrations at HT were higher than another background area, Kosan, Korea. Transportation of pollutants from the Asian continent may be responsible for the elevations of EC+OC at the remote site. More than 74% of the EC and more than 79% of the OC were found in the PM2.5 fraction at the three sampling locations. At PolyU station, PM2.5 consisted of 18.18% OC and 11.16% EC while 17.70% OC and 8.81% EC were found in KT station. Thus OC and EC are major constituents of aerosols in Hong Kong. OC/EC ratios for PM10 and PM2.5 were less than 2 at PolyU and KT stations while the ratio exceeded 3 at HT background station. This indicates that OC measured in the urban area may be emitted directly as a primary aerosol.  相似文献   

2.
An exposure study of children (aged 10-12 years) living in Santiago, Chile, was conducted. Personal, indoor and outdoor fine and inhalable particulate matter (< 2.5 .m in diameter, PM2.5 and < 10 microm in diameter, PM10, respectively), and nitrogen dioxide (NO2) were measured during pilot (N = 8) and main (N = 20) studies, which were conducted during the winters of 1998 and 1999, respectively. For the main study, personal, indoor and outdoor 24-h samples were collected for five consecutive days. Similar mean personal, indoor and outdoor PM2.5 concentrations (69.5, 68.5 and 68.1 microg/m3, respectively) were found. However, for coarse particles (calculated as the difference between measured PM10 and PM2.5, PM2.5-10), indoor and outdoor levels (35.4 and 47.4 microg/m3) were lower than their corresponding personal exposures (76.3 microg/m3). Indoor and outdoor NO2 concentrations were comparable (35.8 and 36.9 ppb) and higher than personal exposures (25.9 ppb). Very low ambient indoor and personal O3 levels were found, which were mostly below the method's limit of detection (LOD). Outdoor particles contributed significantly to indoor concentrations, with effective penetration efficiencies of 0.61 and 0.30 for PM2.5 and PM2.5-10, respectively. Personal exposures were strongly associated with indoor and outdoor concentrations for PM2.5, but weakly associated for PM2.5-10. For NO2, weak associations were obtained for indoor-outdoor and personal-outdoor relationships. This is probably a result of the presence of gas cooking stoves in all the homes. Median I/O, P/I and P/O ratios for PM2.5 were close to unity, and for NO2 they ranged between 0.64 and 0.95. These ratios were probably due to high ambient PM2.5 and NO2 levels in Santiago, which diminished the relative contribution of indoor sources and subjects' activities to indoor and personal PM2.5 and NO2 levels.  相似文献   

3.
Field investigations of target air pollutants at two of the most famous temples in Hong Kong were conducted. The air pollution problems in these two temples during peak and non-peak periods were characterized. The target air pollutants included particulate matters (PM(10), PM(2.5)), volatile organic compounds (VOCs), carbonyl compounds, carbon monoxide (CO), nitrogen oxides (NO(x)), methane (CH(4)), non-methane hydrocarbons (NMHC), organic carbon (OC), elemental carbon (EC), and inorganic ions (Cl(-), NO(3)(-), SO(4)(2-), Na(+), NH(4)(+), and K(+)). The pollutant levels of the two temples during peak period were shown to be significantly higher than those during non-peak period. The highest average CO level was obtained at Temple 1 during peak period, which exceeded IAQO 8-h Good Class criteria. In general, the average PM(2.5)/PM(10) ratios were approximately 82%. The results revealed that the fine particulates (PM(2.5)) constituted the majority of suspended particulates at both temples. It was noted that formaldehyde was the most abundant carbonyl compounds, followed by acetaldehyde. At Temple 1 during peak period, the average benzene concentration exceeded almost 8 times more than Indoor Air Quality Objectives for Office Buildings and Public Places (IAQO) [HKEPD, 2003. Guidance notes for the management of indoor air quality in offices and public places. Indoor air quality management group, The Government of the Hong Kong Special Administrative Region.] Good Class criteria. The average OC/EC ratios ranged from 2.6 to 17 in PM(10) and from 4.2 to 18 in PM(2.5) at two temples, which suggested that OC measured in these two temple areas may be due to both direct emission from incense burning and secondary formation by chemical reactions. The total mass of inorganic ions, organic carbon, and elemental carbon accounted for about 71% in PM(2.5) and 72% in PM(10).  相似文献   

4.
PM2.5 (particle with an aerodynamic diameter less than 2.5 µm) was measured in different microenvironments of Hong Kong (including one urban tunnel, one Hong Kong/Mainland boundary roadside site, two urban roadside sites, and one urban ambient site) in 2003. The concentrations of organic carbon (OC), elemental carbon (EC), water-soluble ions, and up to 40 elements (Na to U) were determined. The average PM2.5 mass concentrations were 229 ± 90, 129 ± 95, 69 ± 12, 49 ± 18 µg m− 3 in the urban tunnel, cross boundary roadside, urban roadside, and urban ambient environments, respectively. Carbonaceous particles (sum of organic material [OM] and EC) were the dominant constituents, on average, accounting for ∼ 82% of PM2.5 emissions in the tunnel, ∼ 70% at the three roadside sites, and ∼ 48% at the ambient site, respectively. The OC/EC ratios were 0.6 ± 0.2 and 0.8 ± 0.1 at the tunnel and roadside sites, respectively, suggesting carbonaceous aerosols were mainly from vehicle exhausts. Higher OC/EC ratio (1.9 ± 0.7) occurred at the ambient site, indicating contributions from secondary organic aerosols. The PM2.5 emission factor for on-road diesel-fueled vehicles in the urban area of Hong Kong was 257 ± 31 mg veh− 1 km− 1, with a composition of ∼ 51% EC, ∼ 26% OC, and ∼ 9% SO4=. The other inorganic ions and elements made up ∼ 11% of the total PM2.5 emissions. OC composed the largest fraction (∼ 51%) in gasoline and liquid petroleum gas (LPG) emissions, followed by EC (∼ 19%). Diesel engines showed higher emission rates than did gasoline and LPG engines for most pollutants, except for V, Br, Sb, and Ba.  相似文献   

5.
Indoor air PM2.5 and PM10 samples were collected at the different types of indoor enviornment in the four hospitals and their adjacent outdoor environments in Guangzhou, China, during the summertime. The objectives of this study were (1) to characterize the indoor PM concentrations and associated carbonaceous species in hospitals, (2) to investigate the potential indoor sources and (3) to reconstruct carbonaceous composition in PM. Additionally, regression analysis was made to evaluate effect of outdoor sources to indoor PM levels and comparison was made between I/O levels in different types of indoor environment to evaluate effects of human activities and ventilation types to indoor PM levels.  相似文献   

6.
The chemical characteristics of ambient particulate matters in urban and rural areas of Hong Kong were determined in this study. A monitoring program starting from November 2000 to February 2001 (winter) and June 2001 to August 2001 (summer) for PM10 and PM2.5 was performed at three monitoring stations in Hong Kong. Twenty-four-hour PM10 and PM2.5 samples were collected once every 6 days at two urban sites, PolyU and KT, and every 12 days at a background site, HT, with Hi-Vol samplers. High concentrations of OC, EC (except in PolyU), water-soluble ions and elements were observed in winter among the three sampling sites for PM10 and PM2.5 fractions. Seasonal variations were significant in background HT. Dilution effect due to the increase in mixing depth and precipitation in summer reduced the concentrations of particulate matters. Long-range transport could contribute to the higher concentrations of particulate matter in the winter. Chemical mass closure calculations were performed for PM10 and PM2.5 observed. Mass closure improved when separate factors (1.4 and 1.9 respectively) were used to convert water-soluble organic carbon (WSOC) and water-insoluble organic carbon (WINSOC) into corresponding organic masses. The urban sites showed high percentages of water-soluble ions in winter and high percentages of carbonaceous species in summer. Better results were obtained for the chemical mass closure analysis in winter than in summer. High temperature and solar radiation in summer increased the rate of the complex photochemical reaction in the atmosphere. Therefore the chemical mass closure analysis would underestimate the volatized species and secondary aerosols during summer.  相似文献   

7.
PM2.5 chemical composition in Hong Kong: urban and regional variations   总被引:1,自引:0,他引:1  
Chemically speciated PM2.5 measurements were made at roadside, urban, and rural background sites in Hong Kong for 1 year during 2000/2001 to determine the spatial and temporal variations of PM2.5 mass and chemical composition in this highly populated region. Annual average PM2.5 concentrations at the urban and rural sites were 34.1 and 23.7 microg m(-3), respectively, approximately 50-100% higher than the United States' annual average National Ambient Air Quality Standard (NAAQS) of 15 microg m(-3). Daily PM2.5 concentrations exceeded the U.S. 24-h NAAQS of 65 microg m(-3) on 19 days, reaching 131+/-8 microg m(-3) at the roadside site on 02/28/2001. Carbonaceous aerosol is the largest contributor to PM2.5 mass (explaining 52-75% of PM2.5 mass at the two urban sites and 32% at the background site), followed by ammonium sulfate (ranging from 23% to 37% at the two urban sites and 51% at the background site). Ammonium sulfate and crustal concentrations showed more uniform spatial distributions, while the largest urban-rural contrasts found in carbonaceous aerosol (likely due to emissions from on-road gasoline and diesel vehicles). Marine influences accounted for 7% of the mass at the background site (more than twice as much as at the two urban sites). Ternary diagrams are utilized to illustrate the different spatial patterns.  相似文献   

8.
Lim JM  Jeong JH  Lee JH  Moon JH  Chung YS  Kim KH 《Indoor air》2011,21(2):145-155
In this study, elemental composition of PM2.5 and the status of indoor/outdoor pollution were investigated in a commercial building near a roadside area in Daejeon, Korea. A total of 60 parallel PM2.5 samples were collected both on the roof (outdoor) and in an indoor office of a building near a highly congested road during the spring and fall of 2008. The concentrations of 23 elements were analysed from these PM2.5 samples using instrumental neutron activation analysis. PM2.5 levels in indoor environment (47.6 ± 16.5 μg/m(3)) were noticeably higher than the outdoor levels (37.7 ± 17.2 μg/m(3)) with the I/O concentration ratio of 1.37 ± 0.33 [correlation coefficient (r) = 0.89, P < 0.001]. Principal component analysis results coincidently showed the predominance of sources such as soil dust, traffic, oil/coal combustion and road dust for both indoor and outdoor microenvironments. An isolated source in the indoor environment was assigned to environmental tobacco smoke (ETS) with high factor loading of Ce, Cl, I, K, La and Zn. The overall results of our study indicate that the sources of indoor constituents were strongly dependent on outdoor processes except for the ones affected by independent sources such as ETS. PRACTICAL IMPLICATIONS: An improved understanding of the factors affecting the indoor PM2.5 concentration levels can lead to the development of an efficient management strategy to control health risks from exposure to indoor PM2.5 and related toxic components. A comparison of our comprehensive data sets indicated that most indoor PM2.5 and associated elemental species were strongly enriched by indoor source activities along with infiltration of ambient outdoor air for a naturally ventilated building.  相似文献   

9.
To characterize indoor air quality at the markets in Hong Kong, three non-air-conditioned and two air-conditioned markets were selected for this study. The indoor air pollutants measured included PM(10) (particulate matters with aerodynamic diameter less than 10 microm), total bacteria count (TBC), carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO(2)) and sulfur dioxide (SO(2)). The indoor and outdoor concentrations of these target air pollutants at these markets were measured and compared. The effects of air conditioning, temperature/relative humidity variation and different stalls on the indoor air quality were also investigated. The results indicated that all of the average indoor concentrations of PM(10), TBC, CO and NO(2) at the markets were below the Hong Kong Indoor Air Quality Objectives (HKIAQO) standards with a few exceptions for PM(10) and TBC. The elevated PM(10) concentrations at Hung Hom, Ngau Tau Kok and Wan Chai markets were probably due to the air filtration of outdoor airborne particulates emitted from vehicular exhaust, whereas high concentrations of airborne bacteria at Sai Ying Pun and Tin Shing markets were linked to the use of air conditioning. Correlation analysis demonstrated that indoor bacteria concentrations were correlated with temperature and relative humidity. The operation of air conditioning did not significantly reduce the levels of air pollutants at the markets. However, the higher indoor/outdoor ratios demonstrated that the operation of air conditioning had influence on the levels of bacteria at the markets. It was found that average PM(10) concentration at poultry stalls was higher than the HKIAQO standard of 180 microg/m(3), and was over two times that measured at vegetable, fish and meat stalls. Furthermore, the concentration of airborne bacteria at the poultry stalls was as high as 1031 CFU/m(3), which was above the HKIAQO standard of 1000 CFU/m(3). The bacteria levels at other three stalls were all below the HKIAQO standard. Statistical analysis indicated that there were no significant differences among the four stalls for CO, NO(x) and SO(2).  相似文献   

10.
Source contributions to urban fine particulate matter (PM(2.5) ) have been modelled using land use regression (LUR) and factor analysis (FA). However, people spend more time indoors, where these methods are less explored. We collected 3-4- day samples of nitrogen dioxide and PM(2.5) inside and outside of 43 homes in summer and winter, 2003-2005, in and around Boston, Massachusetts. Particle filters were analysed for black carbon and trace element concentrations using reflectometry, X-ray fluorescence (XRF), and high-resolution inductively coupled mass spectrometry (ICP-MS). We regressed indoor against outdoor concentrations modified by ventilation, isolating the indoor-attributable fraction, and then applied constrained FA to identify source factors in indoor concentrations and residuals. Finally, we developed LUR predictive models using GIS-based outdoor source indicators and questionnaire data on indoor sources. FA using concentrations and residuals reasonably separated outdoor (long-range transport/meteorology, fuel oil/diesel, road dust) from indoor sources (combustion, smoking, cleaning). Multivariate LUR regression models for factors from concentrations and indoor residuals showed limited predictive power, but corroborated some indoor and outdoor factor interpretations. Our approach to validating source interpretations using LUR methods provides direction for studies characterizing indoor and outdoor source contributions to indoor cocentrations. PRACTICAL IMPLICATIONS: By merging indoor-outdoor modeling, factor analysis, and LUR-style predictive regression modeling, we have added to previous source apportionment studies by attempting to corroborate factor interpretations. Our methods and results support the possibility that indoor exposures may be modeled for epidemiologic studies, provided adequate sample size and variability to identify indoor and outdoor source contributions. Using these techniques, epidemiologic studies can more clearly examine exposures to indoor sources and indoor penetration of source-specific components, reduce exposure misclassification, and improve the characterization of the relationship between particle constituents and health effects.  相似文献   

11.
During 2005-2007, a woodstove changeout program was conducted in a Rocky Mountain valley community in an effort to reduce ambient levels of PM(2.5). In addition to changes in ambient PM(2.5), an opportunity was provided to evaluate the changes in indoor air quality when old stoves were replaced with US Environmental Protection Agency (EPA)-certified woodstoves. PM(2.5) samples were measured in 16 homes prior to and following the changeout. For each sampling event, PM(2.5) mass was continuously measured throughout the 24-h sampling periods, and organic/elemental carbon (OC/EC) and associated chemical markers of woodsmoke were measured from quartz filters. Results showed that average PM(2.5) concentrations and maximum PM(2.5) concentrations were reduced by 71% and 76%, respectively (as measured by TSI DustTraks). Levoglucosan was reduced by 45% following the introduction of the new woodstove. However, the concentrations of resin acids, natural chemicals found in the bark of wood, were increased following the introduction of the new woodstove. There were no discernible trends in methoxphenol levels, likely due to the semi-volatile nature of the species that were measured. Although there is some uncertainty in this study regarding the amount of ambient PM infiltration to the indoor environment, these findings demonstrated a large impact on indoor air quality following this intervention. PRACTICAL IMPLICATIONS: Emissions from residential woodstoves are an important air quality issue (both indoors and ambient) in many regions throughout the US and the world. More specifically, woodstoves have been identified as a major source of PM(2.5) in valley locations throughout the Northern Rocky Mountains, where biomass combustion is the predominant source of home heating. In this study, we present results that demonstrate the dramatic reduction in PM(2.5) concentrations (as measured by TSI, Inc. DustTrak PM(2.5) air samplers) inside homes following the replacement of old, polluting woodstove with new EPA-certified woodstoves.  相似文献   

12.
PM10 and PM2.5 samples were collected in the indoor environments of four hospitals and their adjacent outdoor environments in Guangzhou, China during the summertime. The concentrations of 18 target elements in particles were also quantified. The results showed that indoor PM2.5 levels with an average of 99 microg m(-3) were significantly higher than outdoor PM2.5 standard of 65 microg m(-3) recommended by USEPA [United States Environmental Protection Agency. Office of Air and Radiation, Office of Air Quality Planning and Standards, Fact Sheet. EPA's Revised Particulate Matter Standards, 17, July 1997] and PM2.5 constituted a large fraction of indoor respirable particles (PM10) by an average of 78% in four hospitals. High correlation between PM2.5 and PM10 (R(2) of 0.87 for indoors and 0.90 for outdoors) suggested that PM2.5 and PM10 came from similar particulate emission sources. The indoor particulate levels were correlated with the corresponding outdoors (R(2) of 0.78 for PM2.5 and 0.67 for PM10), demonstrating that outdoor infiltration could lead to direct transportation into indoors. In addition to outdoor infiltration, human activities and ventilation types could also influence indoor particulate levels in four hospitals. Total target elements accounted for 3.18-5.56% of PM2.5 and 4.38-9.20% of PM10 by mass, respectively. Na, Al, Ca, Fe, Mg, Mn and Ti were found in the coarse particles, while K, V, Cr, Ni, Cu, Zn, Cd, Sn, Pb, As and Se existed more in the fine particles. The average indoor concentrations of total elements were lower than those measured outdoors, suggesting that indoor elements originated mainly from outdoor emission sources. Enrichment factors (EF) for trace element were calculated to show that elements of anthropogenic origins (Zn, Pb, As, Se, V, Ni, Cu and Cd) were highly enriched with respect to crustal composition (Al, Fe, Ca, Ti and Mn). Factor analysis was used to identify possible pollution source-types, namely street dust, road traffic and combustion processes.  相似文献   

13.
对上海市某住宅建筑室内外PM10、PM2.5、PM1的浓度进行了测量,研究了最小通风量(外门窗关闭)条件下3种天气时颗粒浓度随时间变化的规律以及相关性,分析了颗粒物浓度与环境温湿度参数之间的关系。研究结果显示,测试期间,室内外空气中细颗粒(PM 2.5)占可吸入颗粒(PM 10)浓度比例分别达65%和87%以上;无明显室内源时,I/O比值小于1且随粒径减小而减小;室内外颗粒浓度相关性与粒径大小有关系,PM1、PM2.5的浓度相关性大于PM10。研究还表明,颗粒物浓度的关联性与天气状况有关系,多云、雨天和阴天时浓度关联性有显著差别;颗粒物的浓度受到室内外温湿度的影响,且受天气状况影响而呈现复杂性。  相似文献   

14.
The indoor air quality of 27 primary schools located in the city centre and suburbs of Antwerp, Belgium, was assessed. The primary aim was to obtain correlations between the various pollutant levels. Indoor:outdoor ratios and the building and classroom characteristics of each school were investigated. This paper presents results on indoor and local outdoor PM2.5 mass concentrations, its elemental composition in terms of K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Pb, Al, Si, S, and Cl, and its black smoke content. In addition, indoor and local outdoor levels of the gases NO2, SO2, O3, and BTEX (benzene, toluene, ethyl benzene, and xylene isomers) were determined. Black smoke, NO2, SO2 and O3, occurred at indoor:outdoor ratios below unity, indicating their significant outdoor sources. No linear correlation was established between indoor and outdoor levels for PM2.5 mass concentrations and BTEX; their indoor:outdoor ratios exceeded unity except for benzene. Classroom PM2.5 occurred with a different elemental composition than local outdoor PM2.5. The re-suspension of dust because of room occupation is probably the main contributor for the I/O ratios higher than 1 reported for elements typically constituting dust particles. Finally, increased benzene concentrations were reported for classrooms located at the lower levels. PRACTICAL IMPLICATIONS: The elevated indoor PM2.5, and BTEX concentrations in primary school classrooms, exceeding the ambient concentrations, raise concerns about possible adverse health effects on susceptible children. This is aggravated by the presence of carpets and in the case of classrooms at lower levels. Analysis of PM2.5's elemental composition indicated a considerable contribution of soil dust to indoor PM2.5 mass. In order to set adequate threshold values and guidelines, detailed information on the health impact of specific PM2.5 composites is needed. The results suggest that local outdoor air concentrations measurements do not provide an accurate estimation of children's personal exposures to the identified air pollutants inside classrooms.  相似文献   

15.
Indoor air quality at nine shopping malls in Hong Kong.   总被引:5,自引:0,他引:5  
Hong Kong is one of the most attractive shopping paradises in the world. Many local people and international tourists favor to spend their time in shopping malls in Hong Kong. Good indoor air quality is, therefore, very essential to shoppers. In order to characterize the indoor air quality in shopping malls, nine shopping malls in Hong Kong were selected for this study. The indoor air pollutants included carbon dioxide (CO2), carbon monoxide (CO), total hydrocarbons (THC), formaldehyde (HCHO), respirable particulate matter (PM10) and total bacteria count (TBC). More than 40% of the shopping malls had 1-h average CO2 levels above the 1000 ppm of the ASHRAE standard on both weekdays and weekends. Also, they had average weekday PM10 concentrations that exceeded the Hong Kong Indoor Air Quality Objective (HKIAQO). The highest indoor PM10 level at a mall was 380 microg/m3. Of the malls surveyed, 30% had indoor airborne bacteria levels above 1000 cfu/m3 set by the HKIAQO. The elevated indoor CO2 and bacteria levels could result from high occupancy combined with insufficient ventilation. The increased PM10 levels could be probably attributed to illegal smoking inside these establishments. In comparison, the shopping malls that contained internal public transport drop-off areas, where vehicles were parked with idling engines and had major entry doors close to heavy traffic roads had higher CO and PM10 indoor levels. In addition, the extensive use of cooking stoves without adequate ventilation inside food courts could increase indoor CO2, CO and PM10 levels.  相似文献   

16.
Indoor air quality (IAQ) of a restaurant has increasingly received a lot of public concerns in Hong Kong. Unfortunately, there is limited data about the IAQ of Hong Kong restaurants. In order to characterize the current IAQ of local restaurants, four restaurants in metropolitan Hong Kong including a Korean barbecue style restaurant, a Chinese hot pot restaurant, a Chinese dim sum restaurant and a Western canteen were selected for this study. The results of this study showed that the mean concentrations of CO2 at restaurants with gas stoves for food cooking in dining areas exceeded the range from 40 to 60% indoor CO2 concentrations at restaurants without gas stoves in dining areas. The average levels of PM10 and PM2.5 at the Korean barbecue style restaurant were as high as 1442 and 1167 microg/m3, respectively. At the Korean barbecue and Chinese hot pot restaurants, the levels of PM2.5 accounted for 80-93% of their respective PM10 concentrations. The 1-h average levels of CO observed at Korean barbecue style and hot pot restaurants were 15,100 and 8000 microg/m3, respectively. Relatively high concentrations of CO2, CO, PM10, PM2.5 benzene, toluene, methylene chloride and chloroform were measured in the dining areas of the Korean barbecue style and the Chinese hot pot restaurants. The operations of pan-frying food and boiling food with soup in a hot pot could generate considerable quantities of air pollutants.  相似文献   

17.
Exposure assessment studies for particulates have been conducted in several U.S. and European cities; however, exposure data remain sparse for Asian populations whose cultural practices and living styles are distinct from those in the developed world. This study assessed personal PM(10) exposure in urban residents and evaluated PM(10) indoor/outdoor levels in communities with different characteristics. Important factors of personal PM(10) exposure in Taiwan were explored. Sampling was conducted in 6 communities in Taiwan, two in each of the three major metropolitan areas. Up to nine non-smoking volunteers in each community carried personal samplers for 24 h. The geometric means (GM) of PM(10) in personal, indoor and outdoor samples were 76.3 microg/m(3) (geometric standard deviation, GSD=1.8), 73.4 microg/m(3) (GSD=1.5), and 85.8 microg/m(3) (GSD=1.7), respectively. It was found that outdoor levels rather than indoor levels contributed significantly to personal exposure. The important exposure factors include the time spent outdoors and on transportation, riding a motorcycle, passing by factories, cooking or being in the kitchen, and incense burning at home. Motorcycle riding and the proximity to factories are related to the special living and housing characteristics in Taiwan, while incense burning and Chinese cooking are culture-related. Motorcyclists experienced an average of 27.7 microg/m(3) higher PM(10) than others, while subjects passing by a factory were exposed to an average of 38.4 microg/m(3) higher PM(10) than others. Effective control and public education should be applied to reduce the contribution of these PM exposure sources.  相似文献   

18.
The daily concentration and chemical composition of PM2.5 was determined in indoor and outdoor 24‐h samples simultaneously collected for a total of 5 weeks during a winter and a summer period in an apartment sited in Rome, Italy. The use of a specifically developed very quiet sampler (<35 dB) allowed the execution of the study while the family living in the apartment led its normal life. The indoor concentration of PM2.5 showed a small seasonal variation, while outdoor values were much higher during the winter study. Outdoor sources were found to contribute significantly to indoor PM concentration especially during the summer, when the apartment was naturally ventilated by opening the windows. During the winter the infiltration of outdoor PM components was lower and mostly regulated by the particle dimensions. Organics displayed In/Out ratios higher than unity during both periods; their indoor production increased significantly during the weekends, where the family stayed mostly at home. PM components were grouped into macrosources (soil, sea, secondary inorganics, traffic, organics). During the summer the main contributions to outdoor PM2.5 came from soil (30%), secondary inorganics (29%) and organics (22%). Organics dominated both indoor PM2.5 during the summer (60%) and outdoor and indoor PM2.5 during the winter (51% and 66%, respectively).  相似文献   

19.
污染物接触量是用以衡量环境污染对人类健康影响的指标之一。调查结果显示,香港居民日常生活主要在各类室内环境,特别是居住建筑中度过,其室内空气污染对居民健康构成威胁。本文的研究首先选择了多间香港不同类型居住建筑,对其室内PM10、CO、NO2等主要室内污染物浓度进行监测,并分析了室内、外PM10浓度与居民室内各种活动等其它有关因素之间的相关关系。其次,结合香港居民日常时间安排调查的结果,计算出各种室内污染物的接触量,对居住建筑室内环境污染对居民健康的影响进行了初步评估。  相似文献   

20.
A weekly monitoring campaign of volatile organic compounds (VOC), with single sampling of 24 h, was carried out in non-residential indoor environments such as libraries, pharmacies, offices, gymnasiums, etc., in order to evaluate the VOC concentrations to which people are exposed. Moreover, an outdoor sample was coupled to each indoor site to point out the influence of indoor sources. They were sampled with Radiello diffusive samplers for thermal desorption and analyzed by GC-MS. As already described in other papers, the VOC levels of most of the indoor sites were higher than that observed in the corresponding outdoor sites. For example, some sites showed a level of pollution that is ten times higher than their corresponding outdoor site. The monitored environments that had higher concentrations of the investigated VOC were the pharmacies, a newspaper stand, a copy center, and the coffee shops. Analysis of the weekly average concentrations of each pollutant and the use of literature allowed pointing out some site-specific characteristics that singled out possible sources of VOC. These results were verified analyzing the indoor-outdoor ratio (I/O) too. Newspaper stands were characterized by very high concentrations of toluene and pharmacies were characterized by high concentrations of aromatic compounds. PRACTICAL IMPLICATIONS: Indoor air pollution caused by volatile organic compounds (VOC) might affect human health at home as well as in public and commercial buildings. The main VOC sources in indoor environments are human activities, personal care products, smoking, house cleaning products, building products, and outside pollution. To preserve human health it is necessary to evaluate the average concentrations of VOC to which people are exposed and to identify the main sources of indoor pollution by means of suitable indoor monitoring campaigns in several environments. These investigations allow pointing out the characteristic critical situations of some indoor environments or some other types of environments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏