1.
The paper presents a field study of occupants’ thermal comfort and residential thermal environment conducted in an urban and a rural area in Hunan province, which is located in central southern China. The study was performed during the cold winter 2006. Twenty-eight naturally ventilated urban residences and 30 also naturally ventilated rural residences were investigated. A comparative analysis was performed on results from urban and rural residences. The mean thermal sensation vote of rural residences is approximately 0.4 higher than that of urban residences at the same operative temperature. Thermal sensation votes calculated by Fanger’s PMV model did not agree with these obtained directly from the questionnaire data. The neutral operative temperature of urban and rural residences is 14.0 and 11.5 °C, respectively. Percentage of acceptable votes of rural occupants is higher than that of urban occupants at the same operative temperature. It suggests that rural occupants may have higher cold tolerance than urban occupants for their physiological acclimatization, or have relative lower thermal expectation than urban occupants because of few air-conditioners used in the rural area. The research will be instrumental to researchers to formulate thermal standards for naturally ventilated buildings in rural areas.  相似文献   

2.
The objective of this study was to develop an adaptive thermal comfort equation for naturally ventilated buildings in hot-humid climates. The study employed statistical meta-analysis of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) RP-884 database, which covered several climatic zones. The data were carefully sorted into three climate groups including hot-humid, hot-dry, and moderate and were analyzed separately. The results revealed that the adaptive equations for hot-humid and hot-dry climates were analogous with approximate regression coefficients of 0.6, which were nearly twice those of ASHRAE and European standards 55 and EN15251, respectively. The equation using the daily mean outdoor air temperature had the highest coefficient of determination for hot-humid climate, compared with other mean temperatures that considered acclimatization of previous days. Acceptable comfort ranges showed asymmetry and leaned toward operative temperatures below thermal neutrality for all climates. In the hot-humid climate, a lower comfort limit was not observed for naturally ventilated buildings, and the adaptive equation was influenced by indoor air speed rather than indoor relative humidity. The new equation developed in this study can be applied to tropical climates and hot-humid summer seasons of temperate climates.  相似文献   

3.
Sleep thermal environments substantially impact sleep quality. To study the sleep thermal environment and thermal comfort in China, this study carried out on-site monitoring of thermal environmental parameters in peoples’ homes, including 166 households in five climate zones, for one year. A questionnaire survey on sleep thermal comfort and adaptive behavior was also conducted. The results showed that the indoor temperature for sleep in northern China was more than 4°C higher than that in southern China in winter, while the indoor temperatures for sleep were similar in summer. Furthermore, 70% of people were satisfied with their sleep thermal environment. Due to the use of air conditioning and window opening in various areas in summer, people were satisfied with their sleep thermal environments. Due to the lack of central heating in the southern region in winter, people feel cold and their sleep thermal environment needs further improvement. The bedding insulation in summer and winter in northern China was 1.83clo and 2.67clo, respectively, and in southern China was 2.21clo and 3.17clo, respectively. Both northern China and southern China used air conditioning only in summer. People in southern China opened their windows all year, while those in northern China opened their windows during the summer and transitional periods.  相似文献   

4.
This paper presents the findings of a field study of occupant thermal comfort and thermal environments with a radiant slab cooling system. The study combined field measurements and questionnaires based on the ASHRAE RP-921 project protocol. A total of 116 sets of data from 82 participants were collected in summer and winter. The results reveal that occupant whole-body thermal sensations with radiant cooling were consistent with the PMV model. The main advantage of radiant cooling for thermal comfort was found to be reduced local thermal discomfort with reduced vertical air temperature difference as well as reduced draft rate. The survey results revealed that 14–22% of participants in the study reported local cold discomfort in the arm–hand and the leg–foot regions. The results indicated that there may be lower limits on air speeds acceptable to occupants. Statistical analysis indicated that occupant thermal votes were free of significant correlation with personal, contextual and psychological factors. Suggestions to improve the questionnaire and the field survey process are offered.  相似文献   

5.
A long-term field survey was conducted with six buildings in order to investigate how the occupants adapt to the indoor climate in office buildings in Japan. More than 5000 questionnaires and corresponding indoor temperatures were collected. Clothing adjustment was observed to be related to outdoor temperature and indoor temperature, as well as dress codes. No considerable differences were found on the thermal perceptions between two groups of buildings, which provided different levels of opportunity for controlling indoor climate. With both groups, the preferred SET* was always close to 26 °C. The comfort temperature was estimated from the results of clothing adjustment and the preferred SET*. The gradient of the comfort temperature to outdoor temperature was found to be between the adaptive model for centralized HVAC and for natural ventilation. It could be caused by that the major part of the occupants in the present study had more opportunity to control their thermal conditions than in the centralized HVAC buildings (i.e. operable windows, controllable HVAC or personal fans).  相似文献   

6.
In the ASHRAE comfort database [1], underpinning the North American naturally ventilated adaptive comfort standard [2], the mean indoor air velocity associated with 90% thermal acceptability was relatively low, rarely exceeding 0.3 m/s. Post hoc studies of this database showed that the main complaint related to air movement was a preference for ‘more air movement’ 3 and 4. These observations suggest the potential to shift thermal acceptability to even higher operative temperature values, if higher air speeds are available. If that were the case, would it be reasonable to expect temperature and air movement acceptability levels at 90%? This paper focuses on this question and combines thermal and air movement acceptability percentages in order to assess occupants. Two field experiments took place in naturally ventilated buildings located on Brazil’s North-East. The fundamental feature of this research design is the proximity of the indoor climate observations with corresponding comfort questionnaire responses from the occupants. Almost 90% thermal acceptability was found within the predictions of the ASHRAE adaptive comfort standard and yet occupants required ‘more air velocity’. Minimum air velocity values were found in order to achieve 90% of thermal and air movement acceptability. From 24 to 27 °C the minimum air velocity for thermal and air movement acceptability is 0.4 m/s; from 27 to 29 °C is 0.41–0.8 m/s, and from 29 to 31 °C is >0.81 m/s. These results highlight the necessity of combining thermal and air movement acceptability in order to assess occupants’ perception of their indoor thermal environment in hot humid climates.  相似文献   

7.
《Energy and Buildings》2006,38(11):1308-1319
The purpose of this survey is to investigate the actual conditions of the residential indoor thermal environment in urban areas in China for evaluating thermal comfort and predicting the energy conservation feasibility for space heating and cooling.The apartment homes under investigation were located in the urban areas of nine major cities. The questionnaire survey revealed building characteristics, the types of space heating and cooling system in use, aspects of life style, during winter and summer seasons, and so on. The measurement showed that winter indoor temperatures in Harbin, Urumqi, Beijing and Xi’an remain at a relatively stable level near 20 °C due to the central heating system installed. However in the other cities lacking central heating systems, indoor temperatures fluctuated as a function of the change of outdoor temperature. On the other hand, summer indoor evening temperatures in Shanghai, Changsha, Chongqing and Hong Kong were higher than the comfort zone of ASHRAE. Therefore it is expected that energy use for space heating and cooling in the southern China will increase in the near future because of occupants’ requirement for comfortable indoor environment. Based on the results yielded by this study, in Beijing the calculation of space heating and cooling loads indicated that the energy used to heat indoor spaces can be halved by installing thermal insulation and properly sealing the building.  相似文献   

8.
This field study was conducted during summer 2009 in Harbin, northeast of China in order to investigate human responses to the thermal conditions in naturally ventilated residential buildings in cold climate. We visited 257 families in six residential communities and collected 423 sets of physical data and subjective questionnaires. The neutral temperature is 23.7 °C, with the clothing insulation of 0.54 clo. The neutral temperature in Harbin is lower than neutral temperatures in warm climates by others, which is in accordance with the thermal adaptive model. 80% of the occupants can accept the air temperature range of 21.5-31.0 °C, which is wider than the summer comfort temperature limits by the adaptive model. The preferred temperature range fell between 24.0 °C and 28.0 °C. About 57.9% of the subjects voted “no change” with the humid range of 40% and 70%. 61.5% of the occupants voted “no change” with the air velocity within the range of 0.05-0.30 m/s. In summer, occupants preferred air velocity of lower than 0.25 m/s even at higher indoor temperature, which is different from the other field studies. The Harbin occupants in naturally ventilated dwellings can achieve thermal comfort by operable windows instead of running air-conditioners.  相似文献   

9.
基于我国湿热地区人群的气候室实验结果,从心理热反应、生理热反应和生理-心理关系等多方面对国内外研究结果进行了系统对比与分析,发现现行国际标准不适用于我国湿热地区,生理热习服和心理热适应是其重要原因。考虑热习服和热适应的影响作用,建立我国湿热地区人群的生理热调节模型与心理-生理模型,是掌握其基础热舒适反应规律、合理制定热环境标准的重要途径。  相似文献   

10.
沿用经典热舒适研究方法,对我国湿热地区自然通风环境受试者分别进行夏季和冬季气候室实验,并对其心理反应与生理反应作冬夏季对比,得到其热反应的季节性变化特征为:与夏季相比,冬季的热感觉保持不变,但热舒适度与可接受度在低温环境显著降低,而在高温环境显著升高;心率显著增加,皮肤温度有所升高,在高温环境下的皮肤湿润度有所降低.季节性变化特征为湿热地区人群心理适应与生理习服提供了重要证据.  相似文献   

11.
Building energy use in India is rising phenomenally. Indian codes prescribe a very narrow comfort temperature range (23-26 °C) for summer. Ventilation controls alone consume 47% of total energy in residences. Thermal comfort field studies in Indian residences were not attempted. The author conducted a field study in apartments in Hyderabad, in summer and monsoon seasons in 2008. This paper presents the occupants’ methods of environmental and behavioural adaptation and impediments in using controls.Only about 40% of the occupants were comfortable in summer due to inadequate adaptive opportunities. The comfort range obtained in this study (26.0-32.5 °C), was way above the standard. Fanger's PMV always overestimated the actual sensation.The occupants used many adaptation methods: the environmental controls, clothing, metabolism and many behavioural actions. Use of fans, air coolers and A/cs increased with temperature, and was impeded by their poor efficacy and noise, occupant's attitudes and economic affordability. A/c and air cooler usage was higher in top floors. Behavioural adaptation was better in summer and was restricted in higher economic groups always. Thermal tolerance was limited in subjects using A/cs and resulted in “thermal indulgence”. This study calls for special adaptation methods for top-floor flats.  相似文献   

12.
对昆明市200户住宅夏季室内热环境参数进行了实测,并进行了现场问卷调查。分析了室内温度、相对湿度、风速、人员服装热阻的分布频率,统计得出了昆明地区住宅夏季室内热环境及人体热舒适的基本情况,并分析了室内热环境改善措施。调查发现,昆明市居民夏季普遍通过开窗进行自然通风以降低室内温度,在非空调条件下约有90%的居民的热感觉在舒适范围内。  相似文献   

13.
The summer season in the state of Kuwait is long with a mean daily maximum temperature of 45 °C. Domestic air conditioning is generally deployed from the beginning of April to the end of October. This accounts for around 75% of Kuwaiti electrical power consumption. In terms of energy conservation, increasing the thermostat temperature by 1 °C could save about 10% of space cooling energy 1 and 2. However, knowledge of indoor domestic temperatures and thermal comfort sensations is important to aid future advice formulation and policy-making related to domestic energy consumption. A field study was therefore conducted during the summers of 2006 and 2007 to investigate the indoor climate and occupants' thermal comfort in 25 air-conditioned domestic buildings in Kuwait. The paper presents statistical data about the indoor environmental conditions in Kuwait domestic residences, together with an analysis of domestic-occupant thermal comfort sensations. With respect to the latter, a total of 111 participants provided 111 sets of physical measurements together with subjective information via questionnaires that were used to collect the data. By using linear regression analysis of responses on the ASHRAE-seven-point thermal sensation scale, the neutral operative temperatures based on Actual Mean Vote (AMV) and Predicted Mean Vote (PMV) were found to be 25.2 °C and 23.3 °C, respectively, in the summer season. Findings from this study provide information about the indoor domestic thermal environment in Kuwait, together with occupant thermal comfort sensations. This knowledge can contribute towards the development of future energy-related design codes for Kuwait.  相似文献   

14.
A comparative study of the occupant comfort (neutral) in a conventional high-rise office block and a contemporary environmentally-concerned building for Sheffield UK climate conditions was carried out. A questionnaire was designed for occupants to rate their workplace environment in terms of the thermal, visual, acoustic and overall perception and satisfaction level. The basic physical parameters were measured at the same time, e.g. air temperature, humidity, illuminance and sound level. It is inferred that (1) There is a noticeable difference between the conventional building and environmentally-concerned building in terms of their thermal and visual environment. (2) A clear distinction of the occupant sensation and satisfaction level towards their thermal and visual environment is presented between these two buildings. (3) The effect of basic physical variables on the occupants’ perception and satisfaction level becomes less significant when minimal standards are attained. (4) The acoustic satisfaction level however, was not perceived differently by the occupants of the two building types.  相似文献   

15.
This study investigates the effectiveness of night ventilation technique for residential buildings in hot-humid climate of Malaysia. This paper firstly presents the results of a survey on usage patterns of windows and air-conditioners in typical Malaysian residential areas. Secondly, the effects of different natural ventilation strategies on indoor thermal environment for Malaysian terraced houses are evaluated based on the results of a full-scale field experiment. The results show that the majority of occupants tend to apply not night ventilation but daytime ventilation in Malaysian residential areas. It can be seen from the field experiment that night ventilation would provide better thermal comfort for occupants in Malaysian terraced houses compared with the other ventilation strategies in terms of operative temperature. However, when the evaporative heat loss of occupants is taken into account by using SET*, the night ventilation would not be the superior technique to the others in providing daytime thermal comfort mainly due to the high humidity conditions. Therefore, the indoor humidity control during the daytime such as by dehumidification would be needed when the night ventilation technique is applied to Malaysian terraced houses. Otherwise, full-day ventilation would be a better option compared with night ventilation.  相似文献   

16.
X. Zhou  Q. Ouyang  Y. Zhu  C. Feng  X. Zhang 《Indoor air》2014,24(2):171-177
To investigate whether occupants’ anticipated control of their thermal environment can influence their thermal comfort and to explain why the acceptable temperature range in naturally ventilated environments is greater than that in air‐conditioned environments, a series of experiments were conducted in a climate chamber in which the thermal environment remained the same but the psychological environment varied. The results of the experiments show that the ability to control the environment can improve occupants’ thermal sensation and thermal comfort. Specifically, occupants’ anticipated control decreased their thermal sensation vote (TSV) by 0.4–0.5 and improved their thermal comfort vote (TCV) by 0.3–0.4 in neutral‐warm environment. This improvement was due exclusively to psychological factors. In addition, having to pay the cost of cooling had no significant influence on the occupants’ thermal sensation and thermal comfort in this experiment. Thus, having the ability to control the thermal environment can improve occupants’ comfort even if there is a monetary cost involved.  相似文献   

17.
《Building and Environment》1999,34(4):479-503
The main function of a mechanically ventilated office building is to provide a healthy and comfortable working environment for occupants, while maintaining minimum energy consumption. Twelve mechanically ventilated buildings were selected. They varied greatly in surface area, number of floors, occupant density, and building use. The indoor air quality, thermal comfort, energy consumption, and perception of occupants were investigated in these buildings. A total of 877 subjects participated in the questionnaire survey during the hot summer months of June, July, and August, and during the cold winter months of January, February, and March. The questions included in the questionnaire dealt with health, environmental sensitivity, work area satisfaction, personal control of the workstations environment, and job satisfaction. Measured parameters concerning the quality of indoor air included ventilation rate, concentration of TVOC, CO2, CO, RH, and formaldehyde. The thermal comfort parameters included room air, mean radiant, plane radiant asymmetry, and dew point temperatures, as well as air velocity and turbulence intensity. Monthly energy consumption data was also gathered for each building. Ventilation performance, in terms of air flow rate and indoor air quality, was compared with the ASHRAE Standard 62-89R (Ventilation for Acceptable Indoor Air Quality. Atlanta: American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc. U.S.A. [1]). The measured and calculated thermal environmental results were also compared with the ASHRAE Standard 55-92 (Thermal Environmental Conditions for Human Occupancy. Atlanta: American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc. U.S.A. [2]). CO2 and CO levels satisfied the recommended limits. The outdoor airflow rate was half that recommended in only one building. The formaldehyde and TVOC levels were moderately higher than suggested comfort levels. However, more than 56% of the occupants rated dissatisfaction with the indoor air quality. Only 63% of the indoor climatic observations fell within the ASHRAE Standard 55-92 summer comfort zone; 27% in the winter. However, only 69% of those surveyed agreed with the comfort zones. More symptoms were reported by workers who perceived IAQ to be poor. Positive relationships were observed between the job satisfaction and satisfaction with office air quality, ventilation, work area temperature, and ratings of work area environment. However, job dissatisfaction did not correlate with symptom reports. The occupants were more dissatisfied with IAQ when they preferred more air movement. In other words, the higher the perceived air movement, the greater the satisfaction with IAQ.  相似文献   

18.
为研究热湿工况下使用工位辐射空调的人体热舒适情况,在人工环境实验室内,通过改变环境背景温度来影响人体的热感觉,并采用热感觉投票(TSV)作为评价标准,重点研究了人体头部、躯干、上肢、下肢以及整体热感觉情况。实验结果表明,尽管背景环境参数超出舒适范围,但使用工位辐射空调能维持受试者的舒适状态,即背景温度稳定在28℃时,平均整体热感觉投票值低于+0.2;背景温度为30℃时,受试者热感觉仍能满足ASHRAE规范中规定的80%可接受范围要求。  相似文献   

19.
Standards governing thermal comfort evaluation are on a constant cycle of revision and public review. One of the main topics being discussed in the latest round was the introduction of an adaptive thermal comfort model, which now forms an optional part of ASHRAE Standard 55. Also on a national level, adaptive thermal comfort guidelines come into being, such as in the Netherlands. This paper discusses two implementations of the adaptive comfort model in terms of usability and energy use for moderate maritime climate zones by means of literature study, a case study comprising temperature measurements, and building performance simulation. It is concluded that for moderate climate zones the adaptive model is only applicable during summer months, and can reduce energy for naturally conditioned buildings. However, the adaptive thermal comfort model has very limited application potential for such climates. Additionally we suggest a temperature parameter with a gradual course to replace the mean monthly outdoor air temperature to avoid step changes in optimum comfort temperatures.  相似文献   

20.
This paper explores how upper extremity skin temperatures correlate with overall-body thermal sensation. Skin temperature measurements of the finger, hand, and forearm might be useful in monitoring and predicting people's thermal state. Subjective perceptions of overall thermal sensation and comfort were collected by repeated surveys, for subjects in a range of test chamber temperatures. A positive temperature gradient (finger warmer than the forearm) of as much as 2 K was seen when subjects felt warm and hot, while a negative temperature gradient (finger colder than the forearm) as much as 8.5 K was seen for cool and cold subjects. A useful warm/cold boundary of 30 °C was found in finger temperature, for both steady state and transient conditions. When finger temperature was above 30 °C, or finger-forearm skin temperature gradient above 0 K, there was no cool discomfort. When finger temperature was below 30 °C, or the finger-forearm skin temperature gradient less than 0 K, cool discomfort was a possibility. Finger temperature and finger-forearm temperature gradient are very similar in their correlation to overall sensation. We also examine how overall sensation is affected by actively manipulating the hand's temperature.  相似文献   