首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
The purpose of this paper is to present the performance analysis of a multifunction heat pipe type adsorption ice maker with activated carbon–CaCl2 as compound adsorbent and ammonia as refrigerant. For this test unit, the heating, cooling and heat recovery processes between two adsorbent beds are performed by multifunction heat pipes. A novel mass and heat recovery adsorption refrigeration cycle is developed. When mass recovery process is implemented before heat recovery process, the performance of the cycle with novel mass and heat recovery processes is much better than that for the cycle with the conventional mass and heat recovery processes. The experimental results show that the former cycle can increase the coefficient of performance (COP) and specific cooling power (SCP) by more than 17% compared with the latter cycle. In comparison with the basic adsorption cycle, the mass and heat recovery cycle can enlarge the cycled refrigerant mass and reduce the power consumption of boiler; the COP and SCP were improved by more than 11% when the mass recovery time was 20 s, while at the optimal mass recovery time of 40 s, the COP improvements for conventional and novel mass and heat recovery cycles are 43.8% and 68.7%, respectively. It was concluded that the novel mass and heat recovery processes are more beneficial to improve the performance of adsorption refrigeration system in comparison with the conventional mass and heat recovery processes.  相似文献   

2.
Numerical analysis of an adsorption cycle employing advanced three-bed mass recovery cycle with and without heat recovery is introduced in this paper. The cycle consists of three silica gel adsorbent beds with different heat utilization functions. The beds can be divided into two cycles with different desorption mechanisms. The working principle of the cycle is introduced, and performances of three-bed, single stage, and mass recovery adsorption cycles are compared in terms of coefficient of performance (COP) and specific cooling power (SCP). The paper also presents the effect of adsorber mass distribution and desorption time on performance. The results show that by applying heat recovery to the cycle, better COP values will be produced compared to that without heat recovery. The results also show that there is an optimum point of adsorber mass distribution and desorption time that produces optimum performance. Furthermore, the paper also compares the performances of the proposed cycle, a single-stage cycle, and a mass recovery cycle.  相似文献   

3.
吸附式制冷在余热回收方面具有很好的前景,设计了用于大客车发动机余热回收的吸附式制冷系统,进行了分布参数的模拟计算,结果显示吸附床设计是比较合理的。同时建立了一种新的回质计算模型,提出了新的回质操作方法。模拟计算显示,回质是改善吸附循环性能的重要手段,回质过程提高了循环SCP和COP达一倍以上,回质过程非常迅速,5s即已完成,可以有效地缩短循环时间,提高循环性能。  相似文献   

4.
Based on the previous work of the authors [K.C. Leong, Y. Liu, Numerical study of a combined heat and mass recovery adsorption cooling cycle, Int. J. Heat Mass Transfer 47 (2004) 4761–4770], a numerical study of the effects of system design and operation parameters on the performance of a combined heat and mass recovery adsorption cycle is presented in this paper. The effects of bed dimensions, bed thermal conductivity, heat exchange fluid velocity, driven temperature and the degree of the heat recovery on the system performance are investigated. It is found that an increase in the driven temperature results in the increase of both the coefficient of performance (COP) and specific cooling power (SCP) of the adsorption cycle. On the other hand, the system performance can be severely deteriorated for velocities of the heat exchange fluid smaller than a critical value. An increase in the bed thickness will result in an increase in COP and a decrease in the SCP. The results of our simulations will provide useful guidelines for the design of this type of advanced adsorption cooling cycle.  相似文献   

5.
A new transient two-dimensional model for the simulation of a combined heat and mass recovery adsorption cooling cycle based on the zeolite NaX/water working pair is proposed in this paper. The model describes the transfer phenomena in the adsorber in detail and is solved by control volume method. Internal and external mass transfer limitations which are neglected by many researchers are considered in the model since they have significant effects on the performance of the adsorption cooling cycle. The numerical results show that the combined heat and mass recovery cycle between two adsorbent beds can increase the coefficient of performance (COP) of an adsorption cooling system by more than 47% compared to the single bed cycle. This numerical model can be used in system optimization and design of adsorption cycles.  相似文献   

6.
This article presents the optimal cycle time and performance of two different types of silica gel–water-based three-bed adsorption chillers employing mass recovery with heating/cooling scheme. A new simulation program has been developed to analyze the effect of cycle time precisely on the performance of the systems. The particle swarm optimization (PSO) method has been used to optimize the cycle time and then the optimum performances of two chillers are compared. Sensitive analysis of cycle time has been conducted using the contour plot of specific cooling power (SCP) with driving heat source temperature at 80°C. It is found that the center point of the contour indicates the maximum SCP value and optimal cycle time, which are comparable with the quantitative values obtained for the PSO method. Both three-bed mass recovery adsorption cycles can produce effective cooling at heat source temperature as low as 50°C along with a coolant at 30°C. The optimal SCP is similar for both cycles and is greater than that of the conventional two-bed adsorption system employing the same adsorbent–refrigerant pair. Consequently, the proposed comparison method is effective and useful to identify the best performance of adsorption cycles.  相似文献   

7.
Three kinds of adsorption refrigeration cycles are analyzed in this paper, a two‐bed continuous cycle, an adiabatic mass recovery cycle, and an isothermal mass recovery cycle. Operating parameters (including desorption temperature, adsorption temperature, cycle adsorption rate, COP, and period refrigerating capacity) with the change of the evaporating temperature, condensing temperature, heat capacity ratio, and heat resource temperature are discussed. The analysis indicates that performance differences between the mass recovery cycle and the two‐bed continuous cycle are reduced with an increasing of evaporating temperature and heat source temperature. By increasing the heat capacity ratio, COP values for the three kinds of cycle decrease. When the heat source temperature is between 70 and 90°C, the performance of the isothermal mass recovery cycle is best. Through study, this paper puts forward that the isothermal mass recovery cycle is the best cycle for adsorption refrigeration systems driven by fuel cell electrical vehicle waste heat. © 2010 Wiley Periodicals, Inc. Heat Trans Asian Res, 39(7): 523–538, 2010; Published online 16 July 2010 in Wiley Online Library ( wileyonlinelibrary.com ). DOI 10.1002/htj.20315  相似文献   

8.
《Renewable Energy》2007,32(3):365-381
The study deals with a solar or waste heat driven three-bed adsorption cooling cycle employing mass recovery scheme. A cycle simulation computer program is developed to investigate the performance of the chiller. The innovative chiller is driven by exploiting solar/waste heat of temperatures between 60 and 90 °C with a cooling source at 30 °C for air-conditioning purpose. The performance of the three-bed adsorption chiller with mass recovery scheme was compared with that of the three-bed chiller without mass recovery. It is found that cooling effect as well as solar/waste heat recovery efficiency, η of the chiller with mass recovery scheme is superior to those of three-bed chiller without mass recovery for heat source temperatures between 60 and 90 °C. However, COP of the proposed chiller is higher than that of the three-bed chiller without mass recovery, when heat source temperature is below 65 °C.  相似文献   

9.
《Applied Thermal Engineering》2005,25(2-3):359-375
A newly developed adsorption water chiller is described and tested. In this adsorption refrigeration cycle system, there is no refrigerant valve. Thus, the problem of mass transfer resistance occurring in the conventional systems when methanol or water is used as refrigerant and resulting in pressure drop during the flow of refrigerant inside the tubing is eliminated. To make the utilization of low heat source with temperature ranging from 70 to 95 °C possible, silica gel–water was selected as working pair. The experimental results proved that it is able to produce a cooling power of 6.3 kW with a COP of about 0.4. The test results demonstrate that, through the heat recovery, the COP can be increased by 34.4% while mass recovery has the effect of increasing the cooling power by 13.7% and the COP by 18.3%. The performances of the system were analyzed for varied condensation temperature and for varied evaporation temperature. Based on the first prototype, the second prototype is designed and manufactured to improve the performance. Primary test results demonstrate that the performance is highly improved. It has a COP of about 0.5 and cooling power 9 kW for 13 °C evaporation temperature.  相似文献   

10.
Adsorption refrigeration systems are commercially developed due to the need of replacing the conventional systems which utilise environmentally harmful refrigerants and consume high grade electrical power. This paper presents the key equations necessary for developing a novel empirical lumped analytical simulation model for commercial 450 kW two-bed silica gel/water adsorption chiller incorporating mass and heat recovery schemes. The adsorption chiller governing equations were solved using MATLAB® platform integrated with REFPROP® to determine the working fluids thermo-physical properties. The simulation model predicted the chiller performance within acceptable tolerance and hence it was used as an evaluation and optimisation tool. The simulation model was used for investigating the effect of changing fin spacing on chiller performance where changing fin spacing from its design value to minimum permissible value increased chiller cooling capacity by 3.0% but decreased the COP by 2.3%. Furthermore, the effect of generation temperature lift on chiller performance and the feasibility of using it as a load control tool will be discussed. Genetic Algorithm optimisation tool was used to determine the optimum cycle time corresponding to maximum cooling capacity, where using the new cycle time increased the chiller cooling capacity by 8.3%.  相似文献   

11.
A three‐effect heat pipe (heat pipe heating, heat pipe cooling and heat pipe heat recovery) adsorption refrigeration system using compound adsorbent (calcium chloride and activated carbon) was designed. The dynamic characteristics of mass and heat pipe heat recovery were studied. The results show that mass recovery and heat pipe heat recovery can improve (specific cooling power) SCP and (coefficient of performance) COP greatly. The averaged SCP of the cycle with mass recovery and the cycle without mass recovery is 502.9 W/kg and 436.7 W/kg at about 30 °C of cooling water temperature and ?15 °C of evaporating temperature. The corresponding COP is 0.27 and 0.24 respectively. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

12.
The study deals with an advanced four-bed mass recovery adsorption refrigeration cycle driven by low temperature heat source. The proposed cycle consists of two basic adsorption refrigeration cycle. The heat source rejected by one cycle is used to power the second cycle. Due to the cascading use of heat and cooling source, all major components of the system maintain different pressure levels. The proposed cycle utilize those pressure levels to enhance the refrigeration mass circulation that leads the system to perform better performances. The performance of the proposed cycle evaluated by the mathematical model at equilibrium condition and compared with the performance of the basic two-bed adsorption refrigeration cycle. It is seen that the cooling effect as well as COP of the proposed cycle is superior to those of the basic cycle. The performances of the cycle are also compared with those of the two-stage cycle. Results also show that though the cooling effect of the proposed cycle is lower than that of two-stage cycle for heat source temperature less than 70 °C, the COP of the cycle, however, is superior to that of two-stage cycle for heat source temperature greater than 60 °C.  相似文献   

13.
A solar-powered adsorption chiller with heat and mass recovery cycle was designed and constructed. It consists of a solar water heating unit, a silica gel-water adsorption chiller, a cooling tower and a fan coil unit. The adsorption chiller includes two identical adsorption units and a second stage evaporator with methanol working fluid. The effects of operation parameter on system performance were tested successfully. Test results indicated that the COP (coefficient of performance) and cooling power of the solar-powered adsorption chiller could be improved greatly by optimizing the key operation parameters, such as solar hot water temperature, heating/cooling time, mass recovery time, and chilled water temperature. Under the climatic conditions of daily solar radiation being about 16–21 MJ/m2, this solar-powered adsorption chiller can produce a cooling capacity about 66–90 W per m2 collector area, its daily solar cooling COP is about 0.1–0.13.  相似文献   

14.
Metal organic framework (MOF), for example Cu-BTC, has the characteristics of structure adversity, high pore volume, large surface area and strong selectivity. It is being considered as a new adsorbent in the field of pressure swing adsorption (PSA). A model describing hydrogen mixture flow, heat and mass transfer with multi-component adsorption is developed for predicting breakthrough curves and performance of PSA cycles in the hydrogen purification system using Cu-BTC as adsorbent. The model is implemented on Aspen platform and validated by experiments. Hydrogen purification performances (purity, recovery, productivity) were evaluated, and parametric study on the performance of hydrogen purification has been performed. The results show that the simulated mole fractions, temperature and pressure in the PSA cycles agree with the experiments very well. In general, the variation trend of hydrogen purity is opposite to that of recovery and productivity. As the parametric study shows, within a certain range, higher adsorption pressure, shorter feeding time and lower feeding flow rate lead to higher hydrogen purity, then lower recovery and productivity. Parametric studies help to effectively improve hydrogen purification performance in the Cu-BTC adsorption bed. Furthermore, a multi-objective algorithm is needed to optimize the PSA process.  相似文献   

15.
This paper has proposed an improved liquefied natural gas (LNG) fuelled combined cycle power plant with a waste heat recovery and utilization system. The proposed combined cycle, which provides power outputs and thermal energy, consists of the gas/steam combined cycle, the subsystem utilizing the latent heat of spent steam from the steam turbine to vaporize LNG, the subsystem that recovers both the sensible heat and the latent heat of water vapour in the exhaust gas from the heat recovery steam generator (HRSG) by installing a condensing heat exchanger, and the HRSG waste heat utilization subsystem. The conventional combined cycle and the proposed combined cycle are modelled, considering mass, energy and exergy balances for every component and both energy and exergy analyses are conducted. Parametric analyses are performed for the proposed combined cycle to evaluate the effects of several factors, such as the gas turbine inlet temperature (TIT), the condenser pressure, the pinch point temperature difference of the condensing heat exchanger and the fuel gas heating temperature on the performance of the proposed combined cycle through simulation calculations. The results show that the net electrical efficiency and the exergy efficiency of the proposed combined cycle can be increased by 1.6 and 2.84% than those of the conventional combined cycle, respectively. The heat recovery per kg of flue gas is equal to 86.27 kJ s?1. One MW of electric power for operating sea water pumps can be saved. The net electrical efficiency and the heat recovery ratio increase as the condenser pressure decreases. The higher heat recovery from the HRSG exit flue gas is achieved at higher gas TIT and at lower pinch point temperature of the condensing heat exchanger. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

16.
This study investigated the cycle optimization of four-bed, silica gel–water adsorption with reheat cycle, where the desorber (upper bed) and adsorber (lower bed) always interact with the condenser and evaporator, to exploit a low heat-source temperature. In a previous study, the performance of a reheat cycle with chilled water outlet temperature fixed at 9°C was observed without considering the cycle optimization. Maintaining a constant chilled water outlet temperature is also of equal importance to improve the conversion efficiency so that maximum cooling capacity can be derived. In this paper, a simulation model of reheat adsorption cycles is developed to analyze the optimization of the cycle time, including adsorption/desorption time, mass recovery time, and preheating/precooling time, with chilled water outlet temperature fixed. The reheat working principle is also introduced. The proposed cycle is compared with the four-bed versison without reheat cycle in terms of coefficient of performance (COP) and cooling capacity. The result shows that the performance of a reheat cycle is superior to that of four-bed version without reheat, especially for low heat-source temperature. For low heat-source temperature (55–65°C) both COP and cooling capacity of the reheat cycle with optimization were raised significantly compared to the high heat-source temperature (70–80°C).  相似文献   

17.
王令宝  卜宪标  马伟斌  陆振能 《热能动力工程》2012,27(3):366-371,396,397
为了开发出利用余热进行吸附制冷的高性能吸附剂,采用浸渍法在真空下将氯化钙担载于粗孔硅胶上,制备了硅胶/氯化钙复合吸附剂,测试了复合吸附剂的吸附等温线和吸附速率,测试结果表明:浸渍法得到的复合吸附剂对水具有更大的吸附能力,在20%的湿度下,复合吸附剂在2h的吸附量为15.64 g/100 g吸附剂,是单一硅胶在相同条件下吸附量的8.06倍。用制备的复合吸附剂制作了一台小型吸附制冷机并进行了测试,当热源温度为90℃,冷却水温度为35℃时,在整个循环周期内(15 min),制冷功率为0.705kW,单位质量吸附剂的制冷功率(SCP)为70.51 W/kg,COP为0.25。  相似文献   

18.
A numerical study of a thermodynamic cycle is described: solar energy powered Rankine cycle using supercritical carbon dioxide as the working fluid for combined power and heat production. A model is developed to predict the cycle performance. Experimental data is used to verify the numerical formulation. Of interest in the present study is the thermodynamic cycle of 0.3–1.0 kW power generation and 1.0–3.0 kW heat output. The effects of the governing parameters on the performance are investigated numerically. The results show that the cycle has a power generation efficiency of somewhat above 20.0% and heat recovery efficiency of 68.0%, respectively. It is seen that the cycle performance is strongly dependent on the governing parameters and they can be optimized to provide maximum power, maximum heat recovery or a combination of both. The power generation and heat recovery are found to be increased with solar collector efficient area. The power generation is also increased with water temperature of the heat recovery system, but decreased with heat exchanging area. It is also seen that the effect of the water flow rate in the heat recovery system on the cycle performance is negligible.  相似文献   

19.
对太阳能固体吸附式制冷技术的应用分析   总被引:2,自引:0,他引:2  
本文介绍了太阳能作为驱动热源的固体吸附式制冷系统的基本组成,依据Polnyi吸附势理论和D-R方程对系统的吸附一解吸过程进行了比较准确的描述,着重对固体吸附式制冷技术的实际应用技术分析。主要必须考虑:在对吸附系统的研究中引入“非平衡吸附”概述进行了动态吸附速度的测定,尽可能地选用带有吸收膜的集热器,以及改善吸附床的传热传质性能等。  相似文献   

20.
A small-scale silica gel-water adsorption system with modular adsorber, which utilizes solar energy to achieve the cogeneration of domestic air conditioning and water heating effect, is proposed and investigated in this paper. A heat recovery process between two adsorbers and a mass recovery process between two evaporators are adopted to improve the overall cooling and heating performance. First, the adsorption system is tested under different modes (different mass recovery, heat recovery, and cogeneration time) to determine the optimal operating conditions. Then, the cogeneration performance of domestic cooling and water heating effect is studied at different heat transfer fluid temperatures. The results show that the optimal time for cogeneration, mass recovery, and heat recovery are 600 s, 40 s, and 40 s, respectively. When the inlet temperature of hot water is around 85°C, the largest cooling power and heating power are 8.25 kW and 21.94 kW, respectively. Under the condition of cooling water temperature of 35°C, the obtained maximum COPc, COPh, and SCP of the system are 0.59, 1.39, and 184.5 W/kg, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏