首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 848 毫秒
1.
This article describes tapping mode atomic force microscopy (AFM) using a heated AFM cantilever. The electrical and thermal responses of the cantilever were investigated while the cantilever oscillated in free space or was in intermittent contact with a surface. The cantilever oscillates at its mechanical resonant frequency, 70.36 kHz, which is much faster than its thermal time constant of 300 micros, and so the cantilever operates in thermal steady state. The thermal impedance between the cantilever heater and the sample was measured through the cantilever temperature signal. Topographical imaging was performed on silicon calibration gratings of height 20 and 100 nm. The obtained topography sensitivity is as high as 200 microVnm and the resolution is as good as 0.5 nmHz(1/2), depending on the cantilever power. The cantilever heating power ranges 0-7 mW, which corresponds to a temperature range of 25-700 degrees C. The imaging was performed entirely using the cantilever thermal signal and no laser or other optics was required. As in conventional AFM, the tapping mode operation demonstrated here can suppress imaging artifacts and enable imaging of soft samples.  相似文献   

2.
This article summarizes improvements to the speed, simplicity and versatility of tapping mode atomic force microscopy (AFM). Improvements are enabled by a piezoelectric microcantilever with a sharp silicon tip and a thin, low-stress zinc oxide (ZnO) film to both actuate and sense deflection. First, we demonstrate self-sensing tapping mode without laser detection. Similar previous work has been limited by unoptimized probe tips, cantilever thicknesses, and stress in the piezoelectric films. Tests indicate self-sensing amplitude resolution is as good or better than optical detection, with double the sensitivity, using the same type of cantilever. Second, we demonstrate self-oscillating tapping mode AFM. The cantilever's integrated piezoelectric film serves as the frequency-determining component of an oscillator circuit. The circuit oscillates the cantilever near its resonant frequency by applying positive feedback to the film. We present images and force-distance curves using both self-sensing and self-oscillating techniques. Finally, high-speed tapping mode imaging in liquid, where electric components of the cantilever require insulation, is demonstrated. Three cantilever coating schemes are tested. The insulated microactuator is used to simultaneously vibrate and actuate the cantilever over topographical features. Preliminary images in water and saline are presented, including one taken at 75.5 μm/s—a threefold improvement in bandwidth versus conventional piezotube actuators.  相似文献   

3.
A noncontact atomic force microscope (nc-AFM) operating in magnetic fields up to ±7 T and liquid helium temperatures is presented in this article. In many common AFM experiments the cantilever is mounted parallel to the sample surface, while in our system the cantilever is assembled perpendicular to it; the so called pendulum mode of AFM operation. In this mode measurements employing very soft and, therefore, ultrasensitive cantilevers can be performed. The ultrahigh vacuum conditions allow to prepare and transfer cantilevers and samples in a requested manner avoiding surface contamination. We demonstrate the possibility of nc-AFM and Kelvin force probe microscopy imaging in the pendulum mode. Ultrasensitive experiments on small spin ensembles are presented as well.  相似文献   

4.
We describe a technique for studying living cells with the atomic force microscope (AFM) in tapping mode using a thermostated, controlled-environment culture system. We also describe the integration of the AFM with bright field, epifluorescence and surface interference microscopy, achieving the highest level of integration for the AFM thus far described. We succeeded in the continuous, long-term imaging of relatively flat but very fragile cytoplasmic regions of COS cells at a lateral resolution of about 70 nm and a vertical resolution of about 3 nm. In addition, we demonstrate the applicability of our technology for continuous force volume imaging of cultured vertebrate cells.
The hybrid instrument we describe can be used to collect simultaneously a diverse variety of physical, chemical and morphological data on living vertebrate cells. The integration of light microscopy with AFM and steady-state culture methods for vertebrate cells represents a new approach for studies in cell biology and physiology.  相似文献   

5.
This paper presents a feedback scheme that simultaneously corrects, in real time, for the imaging artifacts caused by cantilever and photosensor misalignments as well as misinterpretations in relative lateral position of the tip with respect to the sample due to the tip-sample stick in atomic force microscopy (AFM). The optical beam bounce method, typically used in AFM for imaging, is sensitive to inaccuracies of cantilever geometry and the relative misalignment of the laser source, cantilever, and the laser sensitive diode from the intended design. These inaccuracies, which contribute to the geometrical cross-talk between the normal and the lateral signals, become prominent at the atomic and subnanometer scales, and thereby impede high resolution imaging studies. The feedback scheme accounts for these artifacts and makes imaging insensitive to, in fact, practically independent of these inaccuracies. This scheme counteracts the lateral twisting dynamics of the cantilever, and as a result, it avoids the misinterpretation problem of the relative lateral position of the cantilever tip from the sample and thereby avoids the corresponding imaging artifacts that are typically prominent in contact mode friction force microscopy (FFM). The feedback scheme consists of simultaneously regulating the normal as well as the lateral cantilever deflection signal at their respective set points. This not only removes the imaging artifacts due to geometrical misalignments, mechanical cross-talk, and irregular sliding but also the corresponding compensatory control signal gives a more accurate real time measure of the lateral interaction force between the sample and the cantilever as compared to the lateral deflection signal used in FFM. Experimental results show significant improvement, and in some cases, practical elimination of the artifacts. The design and implementation of a split piezoassembly needed for the lateral actuation for the feedback scheme are also presented.  相似文献   

6.
We present high-resolution aperture probes based on non-contact silicon atomic force microscopy (AFM) cantilevers for simultaneous AFM and near-infrared scanning near-field optical microscopy (SNOM). For use in near-field optical microscopy, conventional AFM cantilevers are modified by covering their tip side with an opaque aluminium layer. To fabricate an aperture, this metal layer is opened at the end of the polyhedral probe using focused ion beams (FIB). Here we show that apertures of less than 50 nm can be obtained using this technique, which actually yield a resolution of about 50 nm, corresponding to λ/20 at the wavelength used. To exclude artefacts induced by distance control, we work in constant-height mode. Our attention is particularly focused on the distance dependence of resolution and to the influence of slight cantilever bending on the optical images when scanning at such low scan heights, where first small attractive forces exerted on the cantilever become detectable.  相似文献   

7.
We employed magnetic ACmode atomic force microscopy (MACmode AFM) as a novel dynamic force microscopy method to image surfaces of biological membranes in their native environments. The lateral resolution achieved under optimized imaging conditions was in the nanometer range, even when the sample was only weakly attached to the support. Purple membranes (PM) from Halobacterium salinarum were used as a test standard for topographical imaging. The hexagonal arrangement of the bacteriorhodopsin trimers on the cytoplasmic side of PM was resolved with 1.5nm lateral accuracy, a resolution similar to images obtained in contact and tapping-mode AFM. Human rhinovirus 2 (HRV2) particles were attached to mica surfaces via nonspecific interactions. The capsid structure and 2nm sized protein loops of HRV2 were routinely obtained without any displacement of the virus. Globular and filamentous structures on living and fixed endothelial cells were observed with a resolution of 5-20nm. These examples show that MACmode AFM is a favorable method in studying the topography of soft and weakly attached biological samples with high resolution under physiological conditions.  相似文献   

8.
We present a high resolution electrical conductivity imaging technique based on the principles of eddy current and atomic force microscopy (AFM). An electromagnetic coil is used to generate eddy currents in an electrically conducting material. The eddy currents generated in the conducting sample are detected and measured with a magnetic tip attached to a flexible cantilever of an AFM. The eddy current generation and its interaction with the magnetic tip cantilever are theoretically modeled using monopole approximation. The model is used to estimate the eddy current force between the magnetic tip and the electrically conducting sample. The theoretical model is also used to choose a magnetic tip-cantilever system with appropriate magnetic field and spring constant to facilitate the design of a high resolution electrical conductivity imaging system. The force between the tip and the sample due to eddy currents is measured as a function of the separation distance and compared to the model in a single crystal copper. Images of electrical conductivity variations in a polycrystalline dual phase titanium alloy (Ti-6Al-4V) sample are obtained by scanning the magnetic tip-cantilever held at a standoff distance from the sample surface. The contrast in the image is explained based on the electrical conductivity and eddy current force between the magnetic tip and the sample. The spatial resolution of the eddy current imaging system is determined by imaging carbon nanofibers in a polymer matrix. The advantages, limitations, and applications of the technique are discussed.  相似文献   

9.
With semiconductor structures reaching the nanometer scale, heat conductivity measurements on the mesoscopic range of some tens of nanometers become an increasingly important aspect for the further improvement in digital processing and storage. Also the attempt to use atomic-force microscopy (AFM) technology for high-density data storage by writing information bits as nanometer-sized indentations into a polymer substrate with a heated cantilever tip asks for a careful investigation of the nano-scale heat-conductivity properties of polymers. Furthermore, in many AFM imaging applications, heat conductivity can provide additional information about the material the imaged structures consist of. In this respect, heat conductivity can also become very interesting in studies of usually quite heterogeneous biological samples, if the resolution can attain the nanometer range. In standard scanning thermal microscopy application, the tip forms a thermocouple, which precludes high-resolution imaging, as thermocouples cannot be made sufficiently small. In this paper, which focuses on biological applications, we demonstrate that by using an ultra sharp AFM cantilever with a Joule heating element above the tip structure different molecular components can be distinguished thanks to their different heat-conductivity properties. In this case, the resolution is determined by the actual tip size, and it can reach 10nm.  相似文献   

10.
Huang L  Su C 《Ultramicroscopy》2004,100(3-4):277-285
Changing the method of tip/sample interaction leads to contact, tapping and other dynamic imaging modes in atomic force microscopy (AFM) feedback controls. A common characteristic of these feedback controls is that the primary control signals are based on flexural deflection of the cantilever probes, statically or dynamically. We introduce a new AFM mode using the torsional resonance amplitude (or phase) to control the feedback loop and maintain the tip/surface relative position through lateral interaction. The torsional resonance mode (TRmode™) provides complementary information to tapping mode for surface imaging and studies. The nature of tip/surface interaction of the TRmode facilitates phase measurements to resolve the in-plane anisotropy of materials as well as measurements of dynamic friction at nanometer scale. TRmode can image surfaces interleaved with TappingMode™ with the same probe and in the same area. In this way we are able to probe samples dynamically in both vertical and lateral dimensions with high sensitivity to local mechanical and tribological properties. The benefit of TRmode has been proven in studies of water adsorption on HOPG surface steps. TR phase data yields approximately 20 times stronger contrast than tapping phase at step edges, revealing detailed structures that cannot be resolved in tapping mode imaging. The effect of sample rotation relative to the torsional oscillation axis of the cantilever on TR phase contrast has been observed. Tip wear studies of TRmode demonstrated that the interaction forces between tip and sample could be controlled for minimum tip damage by the feedback loop.  相似文献   

11.
Prototype cantilevers are presented that enable quantitative surface force measurements using contact-mode atomic force microscopy (AFM). The "hammerhead" cantilevers facilitate precise optical lever system calibrations for cantilever flexure and torsion, enabling quantifiable adhesion measurements and friction measurements by lateral force microscopy (LFM). Critically, a single hammerhead cantilever of known flexural stiffness and probe length dimension can be used to perform both a system calibration as well as surface force measurements in situ, which greatly increases force measurement precision and accuracy. During LFM calibration mode, a hammerhead cantilever allows an optical lever "torque sensitivity" to be generated for the quantification of LFM friction forces. Precise calibrations were performed on two different AFM instruments, in which torque sensitivity values were specified with sub-percent relative uncertainty. To examine the potential for accurate lateral force measurements using the prototype cantilevers, finite element analysis predicted measurement errors of a few percent or less, which could be reduced via refinement of calibration methodology or cantilever design. The cantilevers are compatible with commercial AFM instrumentation and can be used for other AFM techniques such as contact imaging and dynamic mode measurements.  相似文献   

12.
The accuracy of topography imaging in contact force mode of atomic force microscopy (AFM) depends on the one-to-one corresponding relationship between the cantilever deflection and the tip–sample distance, whereas such a relationship cannot be always achieved in the presence of friction and incline angle of sample surface. Recently, we have developed a novel operation mode in which we keep the van der Waals force as constant instead of the applied normal force, to eliminate the effect of inclination angle and friction on topography imaging in the contact force mode. We have improved our AFM to enable the new operation mode for validation. Comparative experiments have been performed and the results have shown that the effect of friction and inclination angle on topography imaging in contact mode of AFM can be eliminated or at least decreased effectively by working in the new operation mode we present.  相似文献   

13.
Higher harmonic contributions in the movement of an oscillating atomic force microscopy (AFM) cantilever are generated by nonlinear tip–sample interactions, yielding additional information on structure and physical properties such as sample stiffness. Higher harmonic amplitudes are strongly enhanced in liquid compared to the operation in air, and were previously reported to result in better structural resolution in highly organized lattices of proteins in bacterial S-layers and viral capsids [J. Preiner, J. Tang, V. Pastushenko, P. Hinterdorfer, Phys. Rev. Lett. 99 (2007) 046102]. We compared first and second harmonics AFM imaging of live and fixed human lung epithelial cells, and microvascular endothelial cells from mouse myocardium (MyEnd). Phase–distance cycles revealed that the second harmonic phase is 8 times more sensitive than the first harmonic phase with respect to variations in the distance between cantilever and sample surface. Frequency spectra were acquired at different positions on living and fixed cells with second harmonic amplitude values correlating with the sample stiffness. We conclude that variations in sample stiffness and corresponding changes in the cantilever–sample distance, latter effect caused by the finite feedback response, result in second harmonic images with improved contrast and information that is not attainable in the fundamental frequency of an oscillating cantilever.  相似文献   

14.
A large-sample atomic force microscope (AFM) that allows high resolution observation in both air and liquid has been developed. With a unique beam tracking method, laser beam is capable of reflecting off the same spot on the AFM cantilever throughout raster scan over the entire scan area, either operating in air or in liquid environment. Incorporating the stand-alone AFM probe unit with an automated large sample stage, wide-scan-range imaging can be realized with high resolution and slight distortion. In addition, an image stitching method is utilized to build a broad merged image with range up to millimeters while keeping nanometer order resolution. By using a large-volume liquid bath, large and massive sample can be observed in liquid with this AFM system. Several typical experiments have been carried out to demonstrate the imaging ability and stability of this AFM. Topographic structures of gold pattern on a glass substrate are scanned at two different places on the same specimen surface. The porosity of a sheet of filter paper is then characterized in both air and water. Finally, larger-area AFM image of anodic aluminum oxide template in oxalic acid is on spot obtained by merging several individually scanned images together. Experiments show that this AFM system can offer high resolution and wide range AFM images even for large samples with remarkable capabilities in various environments.  相似文献   

15.
An improved technique for obtaining tapping mode scanning force microscopy (TMSFM) images of soft samples submerged in water is described. This technique makes use of a carbon nanotube several microns in length mounted on a conventional silicon cantilever as the TMSFM probe. The sample is covered by a shallow water layer and during imaging only a portion of the nanotube is submerged. This mode of operation largely eliminates the undesirable effects of hydrodynamic damping and acoustic excitation that are present during conventional tapping mode operation in liquids and leads to high-quality TMSFM images. Because of their low bending force constants, carbon nanotubes are ideal for gentle imaging of soft samples. Because of their small (5–20 nm) diameter and cylindrical shape they provide excellent lateral resolution and are ideal for scanning high aspect ratio objects.  相似文献   

16.
Photothermal excitation is a promising means of actuating microscale structures. It is gaining increased interest for its capability to excite atomic force microscopy (AFM) microcantilevers with wide frequency bandwidth in liquid environments yielding clean resonance peaks without spurious resonances. These capabilities are particularly relevant for high speed and high resolution, quantitative AFM. However, photothermal efficiency is low, which means a large amount of laser power is required for a given mechanical response. The high laser power may cause local heating effects, or spill over the cantilever and damage sensitive samples. In this work, it is shown that by simply changing from a probe with a rectangular cross-section to one with a trapezoidal cross-section, the photothermal efficiency of an uncoated silicon cantilever can be increased by more than a order of magnitude, and the efficiency of a coated cantilever can be increased by a factor of 2. This effect is demonstrated experimentally and explained theoretically using thermomechanical analysis. Results are shown for both air and water, and for normal bending and torsional oscillations.  相似文献   

17.
Enlightened by the principle of scanning probe microscopy or atomic force microscope (AFM), we proposed a novel surface topography imaging system based on the scanning of a piezoelectric unimorph cantilever. The height of sample surface can be obtained by recording the cantilever's strain using an ultra‐sensitive strain gauge and the Z‐axis movement is realized by electric bending of the cantilever. This system can be operated in the way similar to the contact mode in AFM, with the practical height detection resolution better than 100 nm. Imaging of the inner surface of a steel tube and on a transparent wing of a honey bee were conducted and the obtained results showed that this proposed system is a very promising solution for in situ topography mapping. Microsc. Res. Tech. 77:749–753, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

18.
We systematically studied the origin of surface patterns observed on single Sinorhizobium meliloti bacterial cells by comparing the complementary techniques atomic force microscopy (AFM) and scanning electron microscopy (SEM). Conditions ranged from living bacteria in liquid to fixed bacteria in high vacuum. Stepwise, we applied different sample modifications (fixation, drying, metal coating, etc.) and characterized the observed surface patterns. A detailed analysis revealed that the surface structure with wrinkled protrusions in SEM images were not generated de novo but most likely evolved from similar and naturally present structures on the surface of living bacteria. The influence of osmotic stress to the surface structure of living cells was evaluated and also the contribution of exopolysaccharide and lipopolysaccharide (LPS) by imaging two mutant strains of the bacterium under native conditions. AFM images of living bacteria in culture medium exhibited surface structures of the size of single proteins emphasizing the usefulness of AFM for high resolution cell imaging.  相似文献   

19.
Successful imaging of living human cells using atomic force microscopy (AFM) is influenced by many variables including cell culture conditions, cell morphology, surface topography, scan parameters, and cantilever choice. In this study, these variables were investigated while imaging two morphologically distinct human cell lines, namely LL24 (fibroblasts) and NCI H727 (epithelial) cells. The cell types used in this study were found to require different parameter settings to produce images showing the greatest detail. In contact mode, optimal loading forces ranged between 2-2.8 x 10(-9) and 0.1-0.7 x 10(-9) (N) for LL24 and NCI H727 cells respectively. In tapping (AC) mode, images of LL24 cells were obtained using cantilevers with a spring constant of at least 0.32 N/m, while NCI H727 cells required a greater spring constant of at least 0.58 N/m. To obtain tapping mode images, cantilevers needed to be tuned to resonate at higher frequencies than their resonance frequencies to obtain images. For NCI H727 cells, contact mode imaging produced the clearest images. For LL24 cells, contact and tapping mode AFM produced images of comparable quality. Overall, this study shows that cells with different morphologies and surface topography require different scanning approaches and optimal conditions must be determined empirically to achieve images of high quality.  相似文献   

20.
In order to improve the sensitivity and scanning speed of the dynamic AFM, a surface scanning method using higher-order resonant cantilever is adopted and investigated based on the higher-order resonance characteristics of the silicon cantilever, and the theoretical analysis and experimental verification on the higher-order resonance characteristics of the corresponding dynamic AFM cantilever are given. In this method, the cantilever is excited to oscillate near to its higher-order resonant frequency which is several times higher than that of the fundamental mode. Then the characteristic changes a lot compared with the first-order resonant cantilever. Because of the changes of the quality factor, amplitude and the mode shape of the cantilever, the higher-order resonant AFM gets higher sensitivity and scanning speed. Based on the home-built tapping-mode AFM experiment system, the resolution and the response time of the first and second order resonance measured by experiment are respectively: 0.83 nm, 0.42 nm; 1265 μs, 573 μs. The higher-order resonance cantilever has higher sensitivity and the dynamic measurement performance of the cantilever is significantly improved from the experimental results. This can be a useful method to develop AFM with high speed and high sensitivity. Besides above, the surface profile of a grating sample and its three-dimensional topography are obtained by the higher-order resonant mode AFM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号