首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
OBJECTIVE: To measure the T1 times in blood after the administration of the intravascular contrast agent gadofosveset trisodium in humans. MATERIALS AND METHODS: In a pilot study for parameter optimization, the T1-shortening induced by the injection of a single dose (0.03 mmol/kg body weight) of the MR contrast agent Vasovist (Bayer Schering Pharma AG) was measured at B (0) = 1.5 T as a function of time. In four sessions, T1 measurements were performed in the carotid vein of 9 volunteers up to 30 min after injection. T1 times were measured using a segmented saturation recovery turboFLASH (SSRTFL) pulse sequence with 7 different saturation recovery delay times in a total acquisition time of 20 s. RESULTS: The SSRTFL measurements showed T1 times of about 100 ms immediately after injection, which gradually increased to 175 ms at 30 min. The time curve of the R1 = 1/T1 averaged over all volunteers could be described with an exponential decay with a time constant T = 330 +/- 65 s and an amplitude DeltaR1 = 4.1 +/- 0.3 s(-1), and a constant offset of R1(0) = 5.7 +/- 0.2 s(-1). Mean relaxation values are in excellent agreement with theoretical predictions. CONCLUSION: An analytical expression for the initial T1-shortening of Vasovist was derived which can now be used for optimization of the pulse sequence parameters in clinical studies.  相似文献   

2.
OBJECT: This study has two objectives: (1) to compare the kinetics of low diffusion P846 with Gd-DOTA using inversion recovery echo planar (IR-EPI) magnetic resonance (MR) imaging and (2) to determine the potential of P846 in defining myocardial viability in hearts subjected to various injuries using T1-weighted spin echo (T1-SE). MATERIALS AND METHODS: Rats were subjected to (1) occlusive infarcts (n = 16), (2) reperfused ischemic injuries (n = 8) or (3) reperfused infarcts (n = 16). A dose of 0.05 mmol/kg P846 was compared to 0.1 mmol/kg Gd-DOTA. IR-EPI and T1-SE images were obtained during 60 min. T(1), DeltaR(1) and DeltaR(1) ratio were measured on IR-EPI. Infarct extents were evaluated on T1-SE and compared with histochemical staining. RESULTS: Blood DeltaR(1) was higher at 5 min after P846 (6.36 +/- 0.32 s(-1)) than after Gd-DOTA (1.30 +/- 0.14 s(-1); P < 0.001). With P846, occlusive infarcts appeared as a hypoenhanced region surrounded by a hyperenhanced rim that lasted for 60 min. The increase in the DeltaR(1) ratio value was slower after P846 than with Gd-DOTA in the reperfused infarcts, suggesting low diffusion/convection of P846. Gd-DOTA homogenously enhanced both occlusive and reperfused infarcts at 30 min. CONCLUSION: P846 provides better contrast and extended discrimination between occlusive and reperfused infarcts compared with Gd-DOTA. The gadolinium dose could be reduced with P846.  相似文献   

3.
Partial volume averaging of signal from multiple sclerosis lesions influences biexponential fitting of the water T2 relaxation as used for tissue/CSF segmentation of spectroscopic volumes. Periventricular volumes-of-interest comprising CSF, lesion and normal-appearing white matter in varying proportion were studied. The relaxation of the localized water signal was measured at 12 echo times (STEAM, geometric spacing from 30 ms to 2000 ms, least-squares fit). Magnetization transfer (MT) was applied to identify contributions of tissue signal to the CSF component. The T2 of the longlived component (T2(long)=433-1782 ms) and its prolongation after MT were inversely correlated to the MT ratio. Hence, short T2(long) is associated with overestimation of CSF partial volume, and thus metabolite concentrations. A T2-correction for the CSF partial volume was suggested and applied to the quantification of MR spectra of large MS lesions. The T2 of bulk CSF (2280+/-87 ms) and the influence of the TE sampling scheme were also studied.  相似文献   

4.
Objective/Patients: to investigate the efficacy of standard sequences of a low field system for the detection of osteomyelitis, we tested TlwI pre and post i.v. contrast, T2w and fat suppressed IR sequences. Design: on the basis of clinical and laboratory evidence, pathology reports, and three phase granulocyte scintigraphy, osteomyelitis was diagnosed in 18 of 21 patients with Charcot's joints. A consecutive low and high field magnetic resonance (MR) scan confirmed osteomyelitic bone marrow changes in the same osseous regions. These 18 diabetic patients were then studied on a 0.2 Tesla dedicated MR system (Esaote ArtoScan) using TlwI (SE: relaxation time (TR) 520/echo time (TE) 24: axial and coronal) before and after i.v. application of 0.1 mmol/1 Gd-DTPA/kg BW, T2w imaging (TSE: TR 3500/TE 80 or TR 2000/TE 120: axial), and fat suppressed inversion recovery (IR) imaging (short tau inversion recovery (STIR): TR 3000/TE 30/TI 80 or inversion recovery gradient echo (IRGE)/fat suppressed IRGE (GEFS): TR 1000/TE 16m 80: coronal). Results: the SE Tlw sequence showed a significantly higher contrast-to-noise ratio (CNR) before administration of i.v. contrast. The TSE T2w pulse sequence demonstrated bone marrow changes superiorily utilizing a TE of 120 ms (CNR=16.5±2.7 compared to 5.5±2.5 with TE=80 ms). The IRGE showed a higher CNR than the standard STIR (CNR=19.2±2.5 compared to 12.4±2.9). Conclusion: fat suppressed IRGE imaging and longer TE in T2w TSE sequences result in a significantly better, CNR in osteomyelitis. This way, using optimized sequences, low field systems are apt to depict bone marrow changes in the course of osteomyelitis.  相似文献   

5.

Objective

To segment and classify the different attenuation regions from MRI at the pelvis level using the T 1 and T 2 relaxation times and anatomical knowledge as a first step towards the creation of PET/MR attenuation maps.

Materials and methods

Relaxation times were calculated by fitting the pixel-wise intensities of acquired T 1- and T 2-weighted images from eight men with inversion-recovery and multi-echo multi-slice spin-echo sequences. A decision binary tree based on relaxation times was implemented to segment and classify fat, muscle, prostate, and air (within the body). Connected component analysis and an anatomical knowledge-based procedure were implemented to localize the background and bone.

Results

Relaxation times at 3 T are reported for fat (T 1 = 385 ms, T 2 = 121 ms), muscle (T 1 = 1295 ms, T 2 = 40 ms), and prostate (T 1 = 1700 ms, T 2 = 80 ms). The relaxation times allowed the segmentation–classification of fat, prostate, muscle, and air, and combined with anatomical knowledge, they allowed classification of bone. The good segmentation–classification of prostate [mean Dice similarity score (mDSC) = 0.70] suggests a viable implementation in oncology and that of fat (mDSC = 0.99), muscle (mDSC = 0.99), and bone (mDSCs = 0.78) advocates for its implementation in PET/MR attenuation correction.

Conclusion

Our method allows the segmentation and classification of the attenuation-relevant structures required for the generation of the attenuation map of PET/MR systems in prostate imaging: air, background, bone, fat, muscle, and prostate.
  相似文献   

6.
We have used natural abundance13C magnetic resonance spectroscopy (MRS) to measure glycogen content of muscle and liver before and after heavy exercise, and after consumption of different carbohydrate-based drinks. After an overnight fast, five healthy men (mean±SEM age 23±1 years) exercised to exhaustion at 75% of VO2max on two occasions (mean work rate 165±8 W for 78±14 min) and then, in a single blind random order, consumed either of two drinks containing the same carbohydrate load (177 g). Spectra were recorded over Vastus Lateralis muscle and the liver before and after exercise, and hourly for 5 h after the carbohydrate load. In muscle, glycogen content after exercise was 37% and 31% of basal (preexercise) concentration before consuming the drinks. After carbohydrate loading, glycogen concentration had increased significantly (p<0.05) to 70% and 64% of basal concentration respectively after 5 h. Hepatic glycogen concentration did not change significantly throughout. The study demonstrates the feasibility of sequential MRS measurement of muscle and liver glycogen before and after exercise and after carbohydrate loading.  相似文献   

7.

Objectives

We describe measurement of skeletal muscle kinetics with multiple echo diffusion tensor imaging (MEDITI). This approach allows characterization of the microstructural dynamics in healthy and pathologic muscle.

Materials and methods

In a Siemens 3-T Skyra scanner, MEDITI was used to collect dynamic DTI with a combination of rapid diffusion encoding, radial imaging, and compressed sensing reconstruction in a multi-compartment agarose gel rotation phantom and within in vivo calf muscle. An MR-compatible ergometer (Ergospect Trispect) was employed to enable in-scanner plantar flexion exercise. In a HIPAA-compliant study with written informed consent, post-exercise recovery of DTI metrics was quantified in eight volunteers. Exercise response of DTI metrics was compared with that of T2-weighted imaging and characterized by a gamma variate model.

Results

Phantom results show quantification of diffusivities in each compartment over its full dynamic rotation. In vivo calf imaging results indicate larger radial than axial exercise response and recovery in the plantar flexion-challenged gastrocnemius medialis (fractional response: nT2w?=?0.385?±?0.244, nMD?=?0.163?±?0.130, nλ1?=?0.110?±?0.093, nλrad?=?0.303?±?0.185). Diffusion and T2-weighted response magnitudes were correlated (e.g., r?=?0.792, p?=?0.019 for nMD vs. nT2w).

Conclusion

We have demonstrated the feasibility of MEDITI for capturing spatially resolved diffusion tensor data in dynamic systems including post-exercise skeletal muscle recovery following in-scanner plantar flexion.
  相似文献   

8.
Purpose

To improve the precision of a free-breathing 3D saturation-recovery-based myocardial T1 mapping sequence using a post-processing 3D denoising technique.

Methods

A T1 phantom and 15 healthy subjects were scanned on a 1.5 T MRI scanner using 3D saturation-recovery single-shot acquisition (SASHA) for myocardial T1 mapping. A 3D denoising technique was applied to the native T1-weighted images before pixel-wise T1 fitting. The denoising technique imposes edge-preserving regularity and exploits the co-occurrence of 3D spatial gradients in the native T1-weighted images by incorporating a multi-contrast Beltrami regularization. Additionally, 2D modified Look-Locker inversion recovery (MOLLI) acquisitions were performed for comparison purposes. Accuracy and precision were measured in the myocardial septum of 2D MOLLI and 3D SASHA T1 maps and then compared. Furthermore, the accuracy and precision of the proposed approach were evaluated in a standardized phantom in comparison to an inversion-recovery spin-echo sequence (IRSE).

Results

For the phantom study, Bland–Altman plots showed good agreement in terms of accuracy between IRSE and 3D SASHA, both on non-denoised and denoised T1 maps (mean difference −1.4 ± 18.9 ms and −4.4 ± 21.2 ms, respectively), while 2D MOLLI generally underestimated the T1 values (69.4 ± 48.4 ms). For the in vivo study, there was a statistical difference between the precision measured on 2D MOLLI and on non-denoised 3D SASHA T1 maps (P = 0.005), while there was no statistical difference after denoising (P = 0.95).

Conclusion

The precision of 3D SASHA myocardial T1 mapping was substantially improved using a 3D Beltrami regularization based denoising technique and was similar to that of 2D MOLLI T1 mapping, while preserving the higher accuracy and whole-heart coverage of 3D SASHA.

  相似文献   

9.
Central nervous system disorders affect the anatomy and physiology of the lower motoneuron. This fact has an impact on the stimulation parameters, especially on the duration of the stimulating impulses, for functional electrical stimulation in chronic hemiparetic patients. The aim of this study was thus to test the excitability and to determine chronaxie values and strength-duration curves of weak wrist and finger extensor muscles and spastic finger and wrist flexor muscles in the hemiparetic arm. Twelve patients with chronic hemiplegia (>6 months after the onset of the cerebral lesion) participated in the study. A constant current stimulator was used. As to chronaxie values no significant differences were found between the extensor muscles (mean+/-SD: 0.44+/-0.16 ms) and flexor muscles (mean+/-SD: 0.36+/-0.22 ms). A moderate variability was seen for both extensor muscles (0.2-0.8 ms) and flexor muscles (0.1-0.9 ms). These values are well within the normal range determined for innervated muscles. All strength-duration curves were completely normal for each muscle. We conclude that in chronic hemiparetic muscles, impulses of the same duration can be used as in muscles of healthy subjects.  相似文献   

10.

Objectives

The aim of this study was to demonstrate the feasibility of in vivo three-dimensional (3D) relaxation time T 2 * mapping of a dicarboxy-PROXYL radical using continuous-wave electron paramagnetic resonance (CW-EPR) imaging.

Materials and methods

Isotopically substituted dicarboxy-PROXYL radicals, 3,4-dicarboxy-2,2,5,5-tetra(2H3)methylpyrrolidin-(3,4-2H2)-(1-15N)-1-oxyl (2H,15N-DCP) and 3,4-dicarboxy-2,2,5,5-tetra(2H3)methylpyrrolidin-(3,4-2H2)-1-oxyl (2H-DCP), were used in the study. A clonogenic cell survival assay was performed with the 2H-DCP radical using squamous cell carcinoma (SCC VII) cells. The time course of EPR signal intensities of intravenously injected 2H,15N-DCP and 2H-DCP radicals were determined in tumor-bearing hind legs of mice (C3H/HeJ, male, n = 5). CW-EPR-based single-point imaging (SPI) was performed for 3D T 2 * mapping.

Results

2H-DCP radical did not exhibit cytotoxicity at concentrations below 10 mM. The in vivo half-life of 2H,15N-DCP in tumor tissues was 24.7 ± 2.9 min (mean ± standard deviation [SD], n = 5). The in vivo time course of the EPR signal intensity of the 2H,15N-DCP radical showed a plateau of 10.2 ± 1.2 min (mean ± SD) where the EPR signal intensity remained at more than 90% of the maximum intensity. During the plateau, in vivo 3D T 2 * maps with 2H,15N-DCP were obtained from tumor-bearing hind legs, with a total acquisition time of 7.5 min.

Conclusion

EPR signals of 2H,15N-DCP persisted long enough after bolus intravenous injection to conduct in vivo 3D T 2 * mapping with CW-EPR-based SPI.
  相似文献   

11.
Complications during laser lithotripsy include optical fiber bending failure resulting in endoscope damage and low irrigation rates leading to poor visibility. Both problems are related to fiber diameter and limited by the holmium:YAG (Ho:YAG) laser (lambda = 2120 nm) multimode beam profile. This study exploits the thulium fiber laser (lambda = 1908 nm) beam profile for higher power transmission through smaller fibers. Thulium fiber laser radiation with 1 ms pulse duration, pulse rates of 10-30 Hz, and 70-mu m-diameter spot was coupled into silica fibers with 100, 150, and 200 mum core diameters. Fiber transmission, bending, and endoscope irrigation tests were performed. Damage thresholds for 100, 150, and 200 mum fibers averaged 40, 60, and > 80 W, respectively. Irrigation rates measured 35, 26, and 15 mL/min for no fiber, and 100 and 200 mum fibers. Thulium fiber laser energy of 70 mJ delivered at 20 Hz through a 100 mum fiber resulted in vaporization and fragmentation rates of 10 and 60 mg/min for uric acid stones. The thulium fiber laser beam profile provides higher laser power through smaller fibers than Ho:YAG laser, potentially reducing fiber failure and endoscope damage, and allowing greater irrigation rates for improved visibility.  相似文献   

12.
Huang  Zhiwei  Gambarota  Giulio  Xiao  Ying  Wenz  Daniel  Xin  Lijing 《Magma (New York, N.Y.)》2023,36(2):309-315
Purpose

In this study, we aimed to measure the apparent diffusion coefficients (ADCs) of major phosphorous metabolites in the human calf muscle at 7 T with a diffusion-weighted (DW)-STEAM sequence.

Methods

A DW-STEAM sequence with bipolar gradients was implemented at 7 T, and DW MR spectra were acquired in three orthogonal directions in the human calf muscle of six healthy volunteers (TE/TM/TR = 15 ms/750 ms/5 s) at three b-values (0, 800, and 1200 s/mm2). Frequency and phase alignments were applied prior to spectral averaging. Averaged DW MR spectra were analyzed with LCModel, and ADCs of 31P metabolites were estimated.

Results

Four metabolites (phosphocreatine (PCr), adenosine triphosphate (ATP), inorganic phosphate (Pi) and glycerol phosphorylcholine (GPC)) were quantified at all b-values with mean CRLBs below 10%. The ADC values of PCr, ATP, Pi, and GPC were (0.24 ± 0.02, 0.15 ± 0.04, 0.43 ± 0.14, 0.40 ± 0.09) × 10–3 mm2/s, respectively.

Conclusion

The ADCs of four 31P metabolites were successfully measured in the human calf muscle at 7 T, among which those of ATP, Pi and GPC were reported for the first time in humans. This study paves the way to investigate 31P metabolite diffusion properties in health and disease on the clinical MR scanner.

  相似文献   

13.
INTRODUCTION: Given that we have reached a point in the field of muscle energetics where absolute measurements are warranted to take the area forward, we designed an ergometer, including two force and two displacement transducers, allowing dynamic and isometric knee extension within a MR system and accurate measurements of power output. METHODS: On the basis of repeated measurements, the force and displacement transducers accuracy was 1% for values ranging from 0 to 394 N and 4% for values ranging from 0 to 20 cm. In addition, measurements were not affected by magnetic field. MRS experiments in exercising muscle were conducted in eight subjects. They performed two standardized dynamic alternate leg extension exercises (25 and 35% of MVC) while the corresponding metabolic changes were measured using (31)P-MRS. RESULTS: The mean power output produced during both exercises were 63 +/- 16 and 81 +/- 15 W while the eccentric work was reduced i.e. 12 +/- 14 and 21 +/- 6 W for the moderate and heavy exercise respectively. The corresponding metabolic changes were significant with a 20-40% PCr depletion and an end of exercise pH ranging from 0.02 to 0.70 pH units. CONCLUSION: Overall, the present ergometer allows quadriceps exercise in a MR system and should be useful for future metabolic studies for which reliable and absolute quantification of power output is warranted.  相似文献   

14.
Neuromuscular electrical stimulation was used to evoke isometric knee extension contractions in seven individuals with spinal cord injury (SCI) and the time for knee extension torque to rise and fall was measured across a range of knee angles. The stimulated muscles took more than twice as long to develop 50% of maximum torque at an angle of 15 degrees, compared to an angle of 90 degrees. This time difference comprised both an increased delay before torque rose above resting levels (31 +/- 3 ms at 90 degrees, 67 +/- 24 ms at 15 degrees), and a prolonged duration over which torque was rising (72 +/- 14 ms at 90 degrees, 140 +/- 62 ms at 15 degrees). There was no change, however, in the time taken for torque to fall after cessation of stimulation at different knee angles (58 +/- 5-ms delay, 60 +/- 11-ms fall time). The difference in torque rise time with joint angle has implications for modeling functional activities that differ greatly in their joint angles. This study provides regression equations whereby activation times for the quadriceps muscles of individuals with SCI can be predicted for specific angles of knee flexion.  相似文献   

15.
The glass-ceramic in the Li2O-Al2O3-SiO2 system has been prepared by melt quenching route. The crystallization kinetics was studied by differential scanning calorimetry. The effects of sintering temperature on the phase transformation, sintering behavior, bulk density, microstructure, thermal expansion, bending strength and dielectric properties were also investigated by X-ray diffractometry and scanning electron microscopy. (Li, Mg, Zn)1.7Al2O4Si6O12 is the first crystalline phase forming in the glass-ceramic and transforms to LiAlSi3O8 phase at 800 °C. The other two crystalline phases of ZrO2 and CaMgSi2O6 precipitate at 700 and 750 °C, respectively. The densification of this LAS glass-ceramic starts at around 730 °C and stops at about 805 °C. The coefficient of thermal expansion increases with the increasing sintering temperature. The sample sintered at 800 °C for 30 min exhibited excellent properties. The nonisothermal activation energy of crystallization is 149 kJ/mol and the values of Avrami constant (n) are in the range of 3.2 to 3.9. The LAS glass-ceramic sintered at 800 °C for 30 min showed excellent properties. This makes that this material suitable for a number of LTCC applications.  相似文献   

16.
T2 relaxation time study of iron overload in b-thalassemia   总被引:7,自引:0,他引:7  
Myocardial iron deposition occurs as a result of blood transfusion therapy in b-thalassemia major patients. Since this deposition causes various cardiac complications, it is of interest to assess the iron content of the myocardium in relation to the clinical picture of the patients. Two different MRI indices were used to achieve this purpose: the T2 relaxation time and the heart/skeletal muscle signal intensity ratio. ECG gated spin echo images were obtained from 54 adult thalassemic patients, with a mean age of 26 (18–44) years, at TE = 22 ms and 60 ms, using a 1.5 T system. Patients were divided into 2 groups (A and B), according to their serum ferritin levels (> or < 2000 ng ml-1). Results were compared with nine controls, with a mean age of 25 (18–43) years. Heart T2 relaxation time in controls (44.3 ± 3.5 ms) was higher than in group A (29.9 ± 5.7 ms,P< 0.001) and group B (33.4 ± 6.8 ms,P < 0.01). T2 was measurable in 66% of group A and 83% of group B patients. The heart/muscle signal intensity ratio in group A (0.45 ± 0.27) was lower than in group B (0.82 ± 0.33,P < 0.001) and the controls (1.15 ± 0.20,P < 0.001). The heart/muscle signal intensity ratio was measurable in 94% of the patients and demonstrated an inverse relationship with the serum ferritin levels(r = - 0.52, P<0.01). This study indicates that the heart/muscle ratio is a sensitive index of iron overload and it can be measured in the majority of patients, irrespective of tissue iron concentration, thereby offering an advantage over the use of T2 relaxation time. © 1998 Elsevier Science B.V. All rights reserved.  相似文献   

17.
Objective

To implement magnetic resonance fingerprinting (MRF) on a permanent magnet 50 mT low-field system deployable as a future point-of-care (POC) unit and explore the quality of the parameter maps.

Materials and methods

3D MRF was implemented on a custom-built Halbach array using a slab-selective spoiled steady-state free precession sequence with 3D Cartesian readout. Undersampled scans were acquired with different MRF flip angle patterns and reconstructed using matrix completion and matched to the simulated dictionary, taking excitation profile and coil ringing into account. MRF relaxation times were compared to that of inversion recovery (IR) and multi-echo spin echo (MESE) experiments in phantom and in vivo. Furthermore, B0 inhomogeneities were encoded in the MRF sequence using an alternating TE pattern, and the estimated map was used to correct for image distortions in the MRF images using a model-based reconstruction.

Results

Phantom relaxation times measured with an optimized MRF sequence for low field were in better agreement with reference techniques than for a standard MRF sequence. In vivo muscle relaxation times measured with MRF were longer than those obtained with an IR sequence (T1: 182 ± 21.5 vs 168 ± 9.89 ms) and with an MESE sequence (T2: 69.8 ± 19.7 vs 46.1 ± 9.65 ms). In vivo lipid MRF relaxation times were also longer compared with IR (T1: 165 ± 15.1 ms vs 127 ± 8.28 ms) and with MESE (T2: 160 ± 15.0 ms vs 124 ± 4.27 ms). Integrated ΔB0 estimation and correction resulted in parameter maps with reduced distortions.

Discussion

It is possible to measure volumetric relaxation times with MRF at 2.5 × 2.5 × 3.0 mm3 resolution in a 13 min scan time on a 50 mT permanent magnet system. The measured MRF relaxation times are longer compared to those measured with reference techniques, especially for T2. This discrepancy can potentially be addressed by hardware, reconstruction and sequence design, but long-term reproducibility needs to be further improved.

  相似文献   

18.
Background: Skeletal muscle mitochondrial function in type 2 diabetes (T2D) is currently being studied intensively. In vivo 31P magnetic resonance spectroscopy (31P MRS) is a noninvasive tool used to measure mitochondrial respiratory function (MIFU) in skeletal muscle tissue. However, microvascular co-morbidity in long-standing T2D can interfere with the 31P MRS methodology. Aim: To compare 31P MRS-derived parameters describing in vivo MIFU with an in vitro assessment of muscle respiratory capacity and muscle fiber-type composition in T2D patients. Methods: 31P MRS was applied in long-standing, insulin-treated T2D patients. 31P MRS markers of MIFU were measured in the M. vastus lateralis. Muscle biopsy samples were collected from the same muscle and analyzed for succinate dehydrogenase activity (SDH) and fiber-type distribution. Results: Several 31P MRS parameters of MIFU showed moderate to good correlations with the percentage of type I fibers and type I fiber-specific SDH activity (Pearson’s R between 0.70 and 0.75). In vivo and in vitro parameters of local mitochondrial respiration also correlated well with whole-body fitness levels (VO 2peak) in these patients (Pearson’s R between 0.62 and 0.90). Conclusion: Good correlations exist between in vivo and in vitro measurements of MIFU in long-standing insulin-treated T2D subjects, which are qualitatively and quantitatively consistent with previous results measured in healthy subjects. This justifies the use of 31P MRS to measure MIFU in relation to T2D.  相似文献   

19.

Object

To investigate whether postural change from erect to recumbent position affects calf muscle water diffusivity.

Materials and methods

Ten healthy adults (27.2 ± 4.9 years, 3 females) were imaged at baseline (following assumption of recumbent position), and after 34 min (session 2) and 64 min (session 3) of laying supine within a 3T MRI scanner. Diffusion tensor imaging (DTI) eigenvalues, fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were evaluated in five calf muscles (anterior and posterior tibialis and triceps surae) during each of the three imaging sessions.

Results

Significant decreases were observed in all of the eigenvalues and ADC in each of the muscles with postural change. These reductions ranged from 3.2 to 6.7 % and 3.4 to 7.5 % for the various DTI metrics, following 34 and 64 min of supine rest, respectively (P < 0.05). No significant differences were noted in ADC or eigenvalues between the second and third imaging sessions for any muscle. FA did not change significantly with postural manipulation in any muscle compartment.

Conclusion

Diffusion tensor imaging indices were altered with postural change. As differences were not apparent between the latter two imaging sessions, we suggest that a short supine resting period (~34 min) is sufficient for muscle diffusivity to stabilize prior to quantitative MR imaging in healthy young adults.  相似文献   

20.

Objective

To develop a low-cost pedal ergometer compatible with ultrahigh (7 T) field MR systems to reliably quantify metabolic parameters in human lower leg muscle using phosphorus magnetic resonance spectroscopy.

Materials and methods

We constructed an MR compatible ergometer using commercially available materials and elastic bands that provide resistance to movement. We recruited ten healthy subjects (eight men and two women, mean age ± standard deviation: 32.8 ± 6.0 years, BMI: 24.1 ± 3.9 kg/m2). All subjects were scanned on a 7 T whole-body magnet. Each subject was scanned on two visits and performed a 90 s plantar flexion exercise at 40% maximum voluntary contraction during each scan. During the first visit, each subject performed the exercise twice in order for us to estimate the intra-exam repeatability, and once during the second visit in order to estimate the inter-exam repeatability of the time constant of phosphocreatine recovery kinetics. We assessed the intra and inter-exam reliability in terms of the within-subject coefficient of variation (CV).

Results

We acquired reliable measurements of PCr recovery kinetics with an intra- and inter-exam CV of 7.9% and 5.7%, respectively.

Conclusion

We constructed a low-cost pedal ergometer compatible with ultrahigh (7 T) field MR systems, which allowed us to quantify reliably PCr recovery kinetics in lower leg muscle using 31P-MRS.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号