首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
During 1980s, China experienced an unprecedented settlement development which wastriggered by a major change of policies. lmplication of this development in the overall nationalsocio-economic development has been profound and lasting. It is no exaggeration to say that thesuccess of this settlement development has been playing an incomparable role in keeping the so-cial, political and economic stability of our country in the past volatile decade. The author of this paper has an intention to present readers with essentialmatter-of-facts about this development through the use of statistics and figures; to dis-cuss the reasons or momemturns including reforms and innovations that promoted therealization of this development; to explore issues relating to further development.  相似文献   

2.
3.
4.
○By the end of 1991, there have beenaltogether 479 cities in mainland China, anincrease of 12 over the previous year. Theurban population in the mainland was343.97 million (including the agriculturalpopulation in cities), accounting for 30.12%of the total population, an increase of0.74% over 1990. The non-agricultural  相似文献   

5.
6.
7.
8.
9.
《工程机械》2008,39(4):I0001
  相似文献   

10.
至in玩物     
杰克逊版iPod网上开拍;皮革版ThinkPad笔记本;超小禄莱数码双反相机登场;  相似文献   

11.
Fire detection experiments in a road traffic tunnel were performed in the Runehamar test tunnel 5th–8th March 2007. The Runehamar test tunnel is a full profile road traffic tunnel, 1.65 km long, located outside Åndalsnes, Norway. The goal was to examinate smoke and heat detection systems to determinate what kind of principle best suited for detecting a fire in an early stage. The systems were tested during small Heptane pool fires, varying between 0.16 m2 and 1 m2, giving heat release rates from 0.2 MW to 2.4 MW accordingly, and one car fire of about 3–5 MW, and with wind conditions varying from 1.1 m s?1 to 1.6 m s?1. The size of the fires, were designed to be in the range from impossible to difficult to detect. The results were conclusive. Earliest detection of a car fire, fire starts inside, was by smoke detection given fixed limits (3000 μg m?3). With open pool fires, or immediate flames, continues fibre optical heat detection systems was faster given the limits 3 °C/4 min.  相似文献   

12.
13.
This work investigated geopolymeric lightweight concretes based on binders composed of metakaolin with 0% and 25% fly ash, activated with 15.2% of Na2O using sodium silicate of modulus SiO2/Na2O = 1.2. Concretes of densities of 1200, 900 and 600 kg/m3 were obtained by aeration by adding aluminium powder, in some formulations lightweight aggregate of blast furnace slag was added at a ratio binder:aggregate 1:1; curing was carried out at 20 and 75 °C. The compressive and flexural strength development was monitored for up to 180 days. The strength diminished with the reduction of the density and high temperature curing accelerated strength development. The use of the slag had a positive effect on strength for 1200 kg/m3 concretes; reducing the amount of binder used. The thermal conductivity diminished from 1.65 to 0.47 W/mK for densities from 1800 to 600 kg/m3. The microstructures revealed dense cementitious matrices conformed of reaction products and unreacted metakaolin and fly ash. Energy dispersive spectroscopy and X-ray diffraction showed the formation of amorphous silicoaluminate reaction products.  相似文献   

14.
In this paper the thermal analysis by natural convection of a double glazing unit (DGU) is presented. One of the sheet glasses may or may not have a solar control film (SnS–CuxS) on its surface. Solar radiation falls on the outside surface of the DGU at 32 °C, the opposite sheet glass interacts with the inside environment at 24 °C. The governing equations of mass, momentum and energy of the air enclosed between the two sheet glasses are solved, as well as the heat conduction equation for both sheet glasses. The effect of varying the separation distance between the glasses (1.0  b (cm)  10.0) and the incident solar radiation is analyzed (500.0  G (W/m2)  800.0). From the results, it was found that in order to reduce heat gains towards the inside environment, the optimal separation distance between the sheet glasses was b  6.0 cm. It was also observed that, the use of a solar control film in this type of system (double glazing unit) is highly recommended; due to energy gain was reduced by 55% compared to the traditional DGU without solar control film.  相似文献   

15.
A set of experiments was carried out in a 1/9 reduced-scale single-track railway tunnel to investigate the effect of fuel area size on the temperature distribution and behavior of fires in a tunnel with natural ventilation. Methanol pool fires with four different fuel areas 0.6 × 0.3 m2 (1 pan), 1.2 × 0.3 m2 (2 pans), 2.4 × 0.3 m2 (4 pans) and 3.6 × 0.3 m2 (6 pans), were used in these experiments. Data were collected on temperatures, radiative heat flux and mass loss rates. The temperature distribution and smoke layer in the tunnel, along with overflow dimensions and radiant heat at the tunnel entrance were analyzed. The results show that as the fuel area enlarges, the fire gradually becomes ventilation-controlled and the ceiling temperature over the center of fire source declines. Burning at the central region of fire source is depressed due to lack of oxygen. This makes the temperature distribution along the tunnel ceiling change from a typical inverted V-shape to an M-shape. As observed in the experiments, a jet flame appeared at tunnel entrances and both the size and temperature of the flame increased with the enlargement of fuel area leading to a great threat to firefighters and evacuees in actual tunnel fires.  相似文献   

16.
Among tunnel fire safety strategies, evacuation speed in smoke, which is the basic evacuation performance characteristic, is one of the most important factors when assessing safety. An evacuation experiment in a full-scale tunnel filled with smoke has been done in order to clarify the relation between extinction coefficient up to Cs = 1.0 m−1, which includes Cs = 0.4 m−1 as a Japanese road tunnel fire prevention standard, and evacuation speed. The maximum, minimum and mean values of normal walking speeds are almost constant regardless of the extinction coefficient. As for the emergency evacuation speeds, the maximum speed is largely influenced by extinction coefficient, decreasing rapidly from 3.55 m/s at Cs = 0.30 m−1 to 2.53 m/s at Cs = 0.75 m−1 while the minimum and mean speeds are almost constant with a slight decrease as Cs increases. The maximum evacuation speed trends in the present experiments and those in Frantzich and Nillson (2003, 2004) and Fridolf et al. (2013), lie on the same decreasing logarithmic curve as a function of extinction coefficient.  相似文献   

17.
Drilling and blasting is the most widely used excavation method in mining and tunnelling especially in hard rock conditions. But in recent years, the application of roadheaders and impact hammers in hard rock, especially in fractured geological formations has increased considerably. However, it is strongly emphasized that the prediction of the machine performance plays an important role in the time scheduling and in the economy of tunnelling projects and accumulated data will serve a sound basis for performance prediction models.This paper presents information on Istanbul Kadikoy–Kartal metro tunnels which are planned to be constructed in two stages, the first one which is in Kozyatagi–Kadikoy direction and the second in Kozyatagi–Kartal direction. The construction method of the Kozyatagi–Kadikoy station tunnels is first summarized and later, the performance of a roadheader, impact hammer and the results of drilling and blasting methods are compared.The results of this study show that machine utilization time is 28.2% for roadheader and 14.2% for impact hammers. Average net cutting rates (NCR) are 32.26 m3/h for roadheader (218.3 m3/day), net breaking rate (NBR) 13.1 m3/h (45 m3/day) for impact hammers and production rate with drill and blast method (D&B) is found to be 187 m3/day.  相似文献   

18.
Dust emission/deposition flux has been estimated using the gradient method with the two-level (3 and 15 m high) measured PM10 concentrations and the sonic anemometer measured momentum and kinematic heat fluxes at 8 m high from a 20-m monitoring tower located at Naiman (Horqin desert) in the Asian dust source region in China for the winter of November 2007 to March 2008. The time series of measured PM10 concentration at 3 m high is used to identify the dust event and the non-dust event periods. It is found that the dust emission/deposition flux (FC) shows a significant diurnal variation with the maximum emission flux of 5.8 kg km? 2 h? 1 at noon and the minimum of ? 1.6 kg km? 2 h? 1 in the afternoon for the non-dust event cases. Whereas for the dust event cases, the dust emission flux is found to occur when the prevailing winds are westerlies to northerlies with the maximum flux of 1275 kg km? 2 d? 1, while the maximum dust deposition flux of 148 kg km? 2 d? 1 occurs with the prevailing winds of southerlies to easterlies without any diurnal variation. The optimal regression equation between FC and the friction velocity (u*) for the dust emission cases is found to be FC = 9.55 u*3.13 with the R2 value of 0.73. However, this regression equation can be improved by taking into account the convective velocity (w*). The resulting optimal regression equation is found to be FC = 9.3(u* ? 0.1w*)3.19 for the stable stratification (w* < 0) with the R2 value of 0.77 and FC = 10.5(u* + 0.34w*)4.11 for the unstable stratification (w* > 0) with the R2 value of 0.78, suggesting the importance of the convective velocity on the dust emission flux.  相似文献   

19.
《Energy and Buildings》2005,37(10):1007-1016
Solar-reflective roofs stay cooler in the sun than solar-absorptive roofs. Such “cool” roofs achieve lower surface temperatures that reduce heat conduction into the building and the building's cooling load. We monitored the effects of cool roofs on energy use and environmental parameters in six California buildings at three different sites: a retail store in Sacramento; an elementary school in San Marcos (near San Diego); and a four-building cold storage facility in Reedley (near Fresno). The latter included a cold storage building, a conditioning and fruit-palletizing area, a conditioned packing area, and two unconditioned packing areas.Results showed that installing a cool roof reduced the daily peak roof surface temperature of each building by 33–42 K. In the retail store building in Sacramento, for the monitored period of 8 August–30 September 2002, the estimated savings in average air conditioning energy use was about 72 Wh/m2/day (52%). On hot days when the afternoon temperature exceeded 38 °C, the measured savings in average peak demand for peak hours (noon–5 p.m.) was about 10 W/m2 of conditioned area. In the school building in San Marcos, for the monitored period of 8 July–20 August 2002, the estimated savings in average air conditioning energy use was about 42–48 Wh/m2/day (17–18%). On hot days, when the afternoon temperature exceeded 32 °C, the measured savings in average peak demand for hours 10 a.m.–4 p.m. was about 5 W/m2 of conditioned area. In the cold storage facility in Reedley, for the monitored period of 11 July–14 September 2002, and 11 July–18 August 2003, the estimated savings in average chiller energy use was about 57–81 Wh/m2/day (3–4%). On hot days when the afternoon temperature exceeded 38 °C, the measured savings in average peak-period demand (average cooling-power demand during peak demand hours, typically noon–6 p.m.) was about 5–6 W/m2 of conditioned area.Using the measured data and calibrated simulations, we estimated savings for similar buildings installing cool roofs in retrofit applications for all 16 California climate zones. For similar retail stores in climate zones 2 and 4–16, installing a cool roof can save about 6–15 kWh/m2/year of conditioned area. In climate zones 2–16, estimates of average peak demand savings for hours noon–5 p.m. range from 2.9 to 5.8 W/m2. For similar school buildings in climate zones 2–16, installing a cool roof can save from 3 to 6 kWh/m2/year of conditioned roof area. For all 16 climate zones estimates of average peak demand savings for hours noon–5 p.m. range from 2.6 to 3.8 W/m2. In similar cold storage buildings in all 16 climate zones, installing a cool roof can save about 4.5–7.4 kWh/m2/year of conditioned roof area. In all 16 climate zones, estimates of average peak demand savings for hours noon–5 p.m. range from 3.9 to 6.6 W/m2.  相似文献   

20.
C20 and C30 classes of concrete are produced each with addition of Dramix RC-80/0.60-BN type of steel fibers (SFs) at dosages of 0, 30, 60 kg/m3, and their compressive strengths, split tensile strength, moduli of elasticity and toughnesses are measured. Nine reinforced concrete (RC) beams of 300 × 300 × 2000 mm outer dimensions, designed as tension failure and all having the same steel reinforcement, having SFs at dosages of 0, 30, 60 kg/m3 with C20 class concrete, and nine other RC beams of the same peculiarities with C30 class concrete again designed as tension failure and all having the same reinforcement are produced and tested under simple bending. The load versus mid-span deflection relationships of all these RC and steel-fiber-added RC (SFARC) beams under simple bending are recorded. First, the mechanical properties of C20 and C30 classes of concrete with no SFs and with SFs at dosages of 30 and 60 kg/m3 are determined in a comparative way. The flexural behaviours and toughnesses of RC and SFARC beams for C20 and C30 classes of concrete are also determined in a comparative way. The experimentally determined (mid-section load)–(SFs dosage) and (toughness)–(SFs dosage) relationships are given to reveal the quantitative effects of concrete class and SFs dosage on these crucial properties.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号