首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ultrasound imaging can be improved with higher order arrays through elevation dynamic focusing in future, higher channel count systems. However, modifications to current system hardware could yield increased imaging depth-of-field with 1.75D arrays (arrays with individually addressable elements, several rows in elevation) through the use of synthetic elevation imaging. We describe synthetic elevation beamforming methods and its implementation with our 8 /spl times/ 128, 1.75D array (Tetrad Co., Englewood, CO). This array has been successfully interfaced with a Siemens Elegra scanner for summed RF and single channel RF data acquisition. Individual rows of the 8 /spl times/ 128 array can be controlled, allowing for different aperture configurations on transmit and receive beamforming. Advantages of using this array include finer elevation sampling, a larger array footprint for aberration measurements, and elevation focusing. We discuss system tradeoffs that occur in implementing synthetic receive and synthetic transmit/receive elevation focusing and show significant image quality improvements in simulation and phantom data results.  相似文献   

2.
The use of a synthetic receive aperture (SRA) system to increase the resolution, of a phased-array imaging system severalfold, by utilizing the available number of parallel receiver channels to address a larger number of transducer elements through a multiplexer system, is considered. Recent studies indicate that transducers with a very large number of elements will improve the detectability of small or low contrast targets when adaptive focusing is used to compensate for the effects of acoustic velocity inhomogeneities in tissue. With the effectively increased transducer element count afforded by an SRA system, a 1-by-N phased array could be split into an M-by-N array in order to improve resolution in the elevation dimension. Simulation results illustrate the lateral resolution achievable with several types of imaging systems: SRA, synthetic focus, and conventional phased array. Simulated images demonstrate the improvement in contrast resolution achievable using SRA. Experimental results show the improvement in beam width achieved by an experimental SRA system.  相似文献   

3.
许光  周胜增 《声学技术》2014,33(6):554-558
高分辨波束形成器比常规波束形成具有更好的方位分辨力与干扰抑制能力。该波束形成器能够提高阵列输出信干噪比,从而提高声呐的探测性能。与多重信号分类、旋转不变子空间等方法相比,最小方差无畸变响应(Minimum Variance Distortionless Response,MVDR)波束形成器输出真实反映了观察方向的信号功率,同时可提供波束时间序列做后置处理,在水声阵列处理领域得到了快速发展和深入研究。对高分辨MVDR技术在水声阵列处理中的研究进展进行了回顾,重点介绍了其宽带处理、稳健性、运动补偿、解相干等国内外的研究热点和最新成果,同时给出其在各种水声阵列处理领域的应用前景。  相似文献   

4.
张昌  王锦柏 《声学技术》2015,34(6):493-496
介绍了聚焦波束形成的基本原理,分析了一种基于半圆阵的相位补偿方法。通过Matlab仿真得出聚焦波束形成的波束图,相比远场方法,波束宽度减小,旁瓣得到抑制。设计了一种基于FPGA的数字聚焦波束形成器的实时处理结构,使用8组加权系数即可完成成像声呐近场范围内分辨力的改进。通过乒乓操作和并行结构提高处理速度,实时产生72个波束。实验结果表明,所设计的聚焦波束形成器使某型成像声呐近场分辨力得到了提高。  相似文献   

5.
An efficient dynamic focus control scheme for a delay-and-sum-based beamformer is proposed. The scheme simplifies dynamic focus control by exploiting the range-dependent characteristics of the focusing delay. Specifically, the overall delay is divided into a range-independent steering term and a range-dependent focusing term. Because the focusing term is inversely proportional to range, approximation can be made to simplify dynamic focus control significantly at the price of minimal degradation in focusing quality at shallow depths. In addition, the aperture growth controlled by a constant f//sub number/ can also be utilized to devise a nonuniform quantization scheme for the focusing delay values. Efficacy of the proposed scheme is demonstrated using simulated beam plots of a fully sampled, two-dimensional array. Design procedures are also described in detail. One design example shows that, with the proposed dynamic focus control scheme, a 4096-element array only requires 227 independent controllers for the range-dependent focusing term. Moreover, only 28 non-uniform quantization levels are required to achieve the same focusing quality as that of a conventional scheme with 784 uniform quantization levels. The beam plots of a fully sampled array show that sidelobes are slightly increased below the -30 dB level for imaging depths less than 3 cm. At greater depths, there is no observable degradation.  相似文献   

6.
Conventional linear arrays can be used for 3-D ultrasound imaging by moving the array in the elevation direction and stacking the planes in a volume. The point-spread function is larger in the elevation plane, because the aperture is smaller and has a fixed elevation focus. Resolution improvements in elevation can be achieved by applying synthetic aperture focusing to the beamformed-in-plane RF data. The proposed method uses a virtual source placed at the elevation focus for postbeamforming. This has previously been done in 2 steps, in-plane focusing followed by synthetic aperture post-focusing in elevation, due to lack of a simple expression for the exact time of flight. This paper presents a new single step method for calculating the time of flight for a 3-D case using a linear array. The new method is more flexible and is able to beamform a fewer number of points much more efficiently. The method is evaluated using both simulated data and phantom measurements using the RASMUS experimental scanner. Computational cost of the method is higher than the 2-step method for a full volume beamforming, but it allows for a reduction of an order-of-magnitude if 3 planes are used for real-time visualization. In addition, the need for a temporary storage of beamformed data is removed.  相似文献   

7.
A compact medical ultrasound beamformer architecture that uses oversampled 1-bit analog-to-digital (A/D) converters is presented. Sparse sample processing is used, as the echo signal for the image lines is reconstructed in 512 equidistant focal points along the line through its in-phase and quadrature components. That information is sufficient for presenting a B-mode image and creating a color flow map. The high sampling rate provides the necessary delay resolution for the focusing. The low channel data width (1-bit) makes it possible to construct a compact beamformer logic. The signal reconstruction is done using finite impulse reponse (FIR) filters, applied on selected bit sequences of the delta-sigma modulator output stream. The approach allows for a multichannel beamformer to fit in a single field programmable gate array (FPGA) device. A 32-channel beamformer is estimated to occupy 50% of the available logic resources in a commercially available mid-range FPGA, and to be able to operate at 129 MHz. Simulation of the architecture at 140 MHz provides images with a dynamic range approaching 60 dB for an excitation frequency of 3 MHz.  相似文献   

8.
Applying the Capon adaptive beamformer in medical ultrasound imaging results in enhanced resolution by improving the interference-suppressing capabilities of the array. This improvement comes at the expense of an increased computational complexity. We have investigated the application of a beamspace adaptive beamformer for medical ultrasound imaging, which can be used to achieve reduced computational complexity with performance comparable to that of the Capon beamformer. The idea behind beamspace beamforming is that, instead of using the spatial statistics of the elements in the array to differentiate between signals and interference, we use the spatial statistics of a set of orthogonal beams, which are formed in different directions. This represents a shift from element space to beamspace. Because the majority of interference in medical ultrasound imaging is constrained to a limited spatial interval due to the focused transmit beam, this latter space can be reduced to a dimension that is lower than that of element space. We show, using simulations and experimental data, that this dimension can be selected as low as 3 while still achieving performance comparable to its element space counterpart.  相似文献   

9.
冯杰  孙超  唐建生  张揽月 《声学技术》2006,25(6):617-622
为了减小来自旁瓣区快速运动的强干扰对波束域高分辨方位估计方法的影响,提出一种稳健的波束域高分辨方位估计方法。该方法在形成多波束时,将稳健自适应波束形成与零陷扩宽技术相结合,有效地抑制了运动强干扰所造成的快拍失效和扫描方向误差引起的自适应波束图畸变,从而保证波束域方法能准确地估计目标方位。仿真结果验证了该方法的有效性。  相似文献   

10.
A minimum variance (MV) approach for nearfield beamforming of broadband data is proposed. The approach is implemented in the frequency domain, and it provides a set of adapted, complex apodization weights for each frequency subband. The performance of the proposed MV beamformer is tested on simulated data obtained using Field II. The method is validated using synthetic aperture data and data obtained from a plane wave emission. Data for 13 point targets and a circular cyst with a radius of 5 mm are simulated. The performance of the MV beamformer is compared with delay-and-sum (DS) using boxcar weights and Hanning weights and is quantified by the full width at half maximum (FWHM) and the peak-side-lobe level (PSL). Single emission {DS boxcar, DS Hanning, MV} provide a PSL of {-16, -36, -49} dB and a FWHM of {0.79, 1.33, 0.08} mm. Using all 128 emissions, {DS boxcar, DS Hanning, MV} provides a PSL of {-32, -49, -65} dB, and a FWHM of {0.63, 0.97, 0.08} mm. The contrast of the beamformed single emission responses of the circular cyst was calculated as {-18, -37, -40} dB. The simulations have shown that the frequency subband MV beamformer provides a significant increase in lateral resolution compared with DS, even when using considerably fewer emissions. An increase in resolution is seen when using only one single emission. Furthermore, the effect of steering vector errors is investigated. The steering vector errors are investigated by applying an error of the sound speed estimate to the ultrasound data. As the error increases, it is seen that the MV beamformer is not as robust compared with the DS beamformer with boxcar and Hanning weights. Nevertheless, it is noted that the DS does not outperform the MV beamformer. For errors of 2% and 4% of the correct value, the FWHM are {0.81, 1.25, 0.34} mm and {0.89, 1.44, 0.46} mm, respectively.  相似文献   

11.
An experimental system to take advantage of the imaging capabilities of a 5-ring polyvinylidene fluoride (PVDF)-based annular array is presented. The array has a 6-mm total aperture and a 12-mm geometric focus. The experimental system is designed to pulse a single element of the array and then digitize the received data of all array channels simultaneously. All transmit/receive pairs are digitized and then the data are post-processed with a synthetic-focusing technique to achieve an enhanced depth of field (DOF). The performance of the array is experimentally tested with a wire phantom consisting of 25-microm diameter wires diagonally spaced at 1-mm by 1-mm intervals. The phantom permitted the efficacy of the synthetic-focusing algorithm to be tested and was also used for two-way beam characterization. Experimental results are compared to a spatial impulse response method beam simulation. After synthetic focusing, the two-way echo amplitude was enhanced over the range of 8 to 19 mm and the 6-dB DOF spanned from 9 to 15 mm. For a wire at a fixed axial depth, the relative time delays between transmit/receive ring pairs agreed with theoretical predictions to within +/- 2 ns. To further test the system, B-mode images of an excised bovine eye were rendered.  相似文献   

12.
Capon beamforming in medical ultrasound imaging with focused beams   总被引:1,自引:0,他引:1  
Medical ultrasound imaging is conventionally done by insonifying the imaged medium with focused beams. The backscattered echoes are beamformed using delay-and-sum operations that cannot completely eliminate the contribution of signals backscattered by structures off the imaging beam to the beamsum. It leads to images with limited resolution and contrast. This paper presents an adaptation of the Capon beamformer algorithm to ultrasound medical imaging with focused beams. The strategy is to apply data-dependent weight functions to the imaging aperture. These weights act as lateral spatial filters that filter out off-axis signals. The weights are computed for each point in the imaged medium, from the statistical analysis of the signals backscattered by that point to the different elements of the imaging probe when insonifying it with different focused beams. Phantom and in vivo images are presented to illustrate the benefits of the Capon algorithm over the conventional delay and-sum approach. On heart sector images, the clutter in the heart chambers is decreased. The endocardium border is better defined. On abdominal linear array images, significant contrast and resolution enhancement are observed.  相似文献   

13.
A real-time 3-D imaging system requires the development of a beamformer that can generate many beams simultaneously. In this paper, we discuss and evaluate a suitable synthetic aperture beamformer. The proposed beamformer is based on a pipelined network of high speed digital signal processors (DSP). By using simple interpolation-based beamforming, only a few calculations per pixel are required for each channel, and an entire 2-D synthetic aperture image can be formed in the time of one transmit event. The performance of this beamformer was explored using a computer simulation of the radiation pattern. The simulations were done for a full 64-element array and a sparse array with the same receive aperture but only five transmit elements. We assessed the effects of changing the sampling rate and amplitude quantization by comparing the relative levels of secondary lobes in the radiation patterns. The results show that the proposed beamformer produces a radiation pattern equivalent to a conventional beamformer using baseband demodulation, provided that the sampling rate is approximately 10 times the center frequency of the transducer (34% bandwidth pulse). The simulations also show that the sparse array is not significantly more sensitive to delay or amplitude quantization than the full array.  相似文献   

14.
Shadowing of an imaging aperture occurs when ultrasound beams are partially obstructed by an acoustically hard tissue, e.g., bone tissue. This effect leads to reduced resolution and, in some cases, geometrical distortion. In this paper, we initially introduce a binary apodization model to simulate effects of the shadowing on the point scatterers located close to a bone structure. Further, in a simulation study and an in vitro experiment, the minimum variance (MV) beamforming method is employed to image scatterers partly located in the shadow of bone. We show that the MV beamformer can result in a distorted image when the imaging aperture is highly obstructed by the bone structure. This distortion can be seen as an apparent lateral shift of the point spread function and a decrease in the sensitivity. Based on the signal power across the aperture, we adaptively determine the shadowed elements and discard their corresponding data from the covariance matrix to improve the MV beamformer performance. This modified MV beamformer can retain the resolution and compensate for the apparent lateral shifting and signal attenuation for the shadowed point scatterers.  相似文献   

15.
Yura HT 《Applied optics》1995,34(15):2774-2779
The mean on-axis far-field (or focal-plane) irradiance of a Gaussian beam that is truncated by a circular aperture in the presence of atmospheric turbulence is considered. In the absence of turbulence, an accurate analytic approximation for the irradiance distribution that is valid within the main central lobe of the beam is presented. Based on this approximation, the mean on-axis far-field irradiance and the corresponding turbulence Strehl ratio for the truncated Gaussian beam are then obtained. By maximization of the on-axis irradiance, the optimum ratio of the beam diameter to the aperture diameter in the presence of turbulence is obtained, and the results for the corresponding maximum on-axis irradiance as a function of the strength of turbulence are presented. In particular, for D/r(0) > 1, where D is the aperture diameter and r(0) is Fried's coherence length, optimum truncation of a Gaussian beam and uniform illumination of a circular aperture (where the same total power isuniformly distributed over the aperture) result in the same on-axis irradiance in the presence of uncompensated turbulence.  相似文献   

16.
Near-field scanning optical microscopy (NSOM) offers high optical resolution beyond the diffraction limit for various applications in imaging, sensing, and lithography; however, for many applications the very low brightness of NSOM aperture probes is a major constraint. Here, we report a novel NSOM aperture probe that gives a 100× higher throughput and 40× increased damage threshold than conventional near-field aperture probes. These brighter probes facilitate near-field imaging of single molecules with apertures as small as 45 nm in diameter. We achieve this improvement by nanostructuring the probe and by employing a novel variant of extraordinary optical transmission, relying solely on a single aperture and a coupled waveguide. Comprehensive electromagnetic simulations show good agreement with the measured transmission spectra. Due to their significantly increased throughput and damage threshold, these resonant configuration probes provide an important step forward for near-field applications.  相似文献   

17.
This paper presents characterization and initial imaging results of a 32 x 32 element two-dimensional capacitive micromachined ultrasonic transducer array. The devices are fabricated using a wafer bonding process in which both the insulation layer and the membrane are user-deposited silicon nitride. The transducers use a row-column addressing scheme to simplify the fabrication process and beamformer. By adjusting the number of rows and columns that are biased, the effective aperture of the transducer can be adjusted. This is significant because it permits imaging in the near-field of the transducer without the use of a lens. The effect on the transmit beam profile is demonstrated. The transducer has a center frequency of 5.9 MHz and a relative bandwidth of 110%. Images of horizontal and vertical wires are taken to demonstrate image resolution. A three-dimensional image of four pin heads is also demonstrated.  相似文献   

18.
Recently, significant improvement in image resolution has been demonstrated by applying adaptive beamforming to medical ultrasound imaging. In this paper, we have used the minimum-variance beamformer to show how the low sidelobe levels and narrow beamwidth of adaptive methods can be used, not only to increase resolution, but also to enhance imaging in several ways. By using a minimum-variance beamformer instead of delay-and-sum on reception, reduced aperture, higher frame rates, or increased depth of penetration can be achieved without sacrificing image quality. We demonstrate comparable resolution on images of wire targets and a cyst phantom obtained with a 96-element, 18.5-mm transducer using delay-and-sum, and a 48-element, 9.25-mm transducer using minimum variance. To increase frame rate, fewer and wider transmit beams in combination with several parallel receive beams may be used. We show comparable resolution to delay-and-sum using minimum variance, 1/4th of the number of transmit beams and 4 parallel receive beams, potentially increasing the frame rate by 4. Finally, we show that by lowering the frequency of the transmitted beam and beamforming the received data with the minimum variance beamformer, increased depth of penetration is achieved without sacrificing lateral resolution.  相似文献   

19.
In adaptive ultrasound imaging, accurate estimation of the array covariance matrix is of great importance, and biases the performance of the adaptive beamformer. The more accurately the covariance matrix can be estimated, the better the resolution and contrast can be achieved in the ultrasound image. To this end, in this paper, we have used the forward-backward spatial averaging for array covariance matrix estimation, which is then employed in minimum variance (MV) weights calculation. The performance of the proposed forward-backward MV (FBMV) beamformer is tested on simulated data obtained using Field II. Data for two closely located point targets surrounded by speckle pattern are simulated showing the higher amplitude resolution of the FBMV beamformer in comparison to the forward-only (F-only) MV beamformers, without the need for diagonal loading. A circular cyst with a diameter of 6 mm and a phantom containing wire targets and two cysts with different diameters of 8 mm and 6 mm are also simulated. The simulations show that the FBMV beamformer, in contrast to the F-only MV, could estimate the background speckle statistics without the need for temporal smoothing, resulting in higher contrast for the FBMV-resulted image in comparison to the MV images. In addition, the effect of steering vector errors is investigated by applying an error of the sound speed estimate to the ultrasound data. The simulations show that the proposed FBMV beamformer presents a satisfactory robustness against data misalignment resulted from steering vector errors, outperforming the regularized F-only MV beamformer. These improvements are achieved without compromising the good resolution of the MV beamformer and resulted from more accurate estimation of the covariance matrix and consequently, the more accurate setting of the MV weights.  相似文献   

20.
Aperture weighting functions are critical design parameters in the development of ultrasound systems because beam characteristics affect the contrast and point resolution of the final output image. In previous work by our group, we developed a metric that quantifies a broadband imaging system's contrast resolution performance. We now use this metric to formulate a novel general ultrasound beamformer design method. In our algorithm, we use constrained least squares (CLS) techniques and a linear algebra formulation to describe the system point spread function (PSF) as a function of the aperture weightings. In one approach, we minimize the energy of the PSF outside a certain boundary and impose a linear constraint on the aperture weights. In a second approach, we minimize the energy of the PSF outside a certain boundary while imposing a quadratic constraint on the energy of the PSF inside the boundary. We present detailed analysis for an arbitrary ultrasound imaging system and discuss several possible applications of the CLS techniques, such as designing aperture weightings to maximize contrast resolution and improve the system depth of field.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏