1.
In this study, nucleate boiling heat transfer coefficients (HTCs) of HCFC22, HFC134a, HFC125, HFC32 were measured on a low fin, Turbo-B, and Thermoexcel-E tubes. All data were taken at the liquid pool temperature of 7 °C on horizontal tubes of 152 mm length and 18.6–18.8 mm outside diameter at heat fluxes of 10–80 kW m−2 with an interval of 10 kW m−2 in the decreasing order of heat flux. For a plain and low fin tubes, refrigerants with higher vapor pressures showed higher nucleate boiling HTCs consistently. This was due to the fact that the wall superheat required to activate given size cavities became smaller as pressure increased. For Turbo-B and Thermoexcel-E tubes, HFC125 showed a peculiar behavior exhibiting much reduced HTCs due to its high reduced pressure. The heat transfer enhancement ratios of the low fin, Turbo-B, and Thermoexcel-E tubes were 1.09–1.68, 1.77–5.41, 1.64–8.77 respectively in the range of heat fluxes tested.  相似文献   

2.
In this study, external condensation heat transfer coefficients (HTCs) of HFC134a and R1234yf are measured on a plain, low fin, and Turbo-C tubes at the saturated vapor temperature of 39 °C with the wall subcooling of 3-8 °C. R1234yf is a new alternative refrigerant of low greenhouse warming potential for replacing HFC134a, one of the greenhouse gases in Kyoto protocol, used extensively in automobile air conditioners and other refrigeration systems. Test results show that the condensation HTCs of R1234yf are very similar to those of HFC134a for all three surfaces tested. For the development of heat transfer correlations, thorough property measurements are needed for R1234yf in the near future.  相似文献   

3.
The flow boiling heat transfer coefficient of the low-GWP (global warming potential) refrigerant HFO-1234yf inside a smooth small-diameter horizontal tube (inner diameter: 2 mm) was experimentally investigated. The local heat transfer coefficient was measured at heat fluxes of 6-24 kW m−2, mass fluxes of 100-400 kg m−2 s−1, an evaporating temperature of 288.15 K, and an inlet vapor quality of 0-0.25. The results show that the effect of heat flux on the heat transfer was large at low vapor quality, while the effect of mass flux was large at high vapor quality. The heat transfer coefficient of HFO-1234yf was almost the same as that of R-134a. The heat transfer coefficients calculated based on correlations with Saitoh et al. agreed well with the measured values compared to other correlations. The measured pressure drop agreed well with that predicted by the Lockhart-Martinelli correlation.  相似文献   

4.
R1234ze(E) has a GWP<1 and a normal boiling temperature approximately 7.3 °C lower than that of R134a; it represents an interesting candidate for its replacement as working fluid in refrigerating machines. The refrigerant charge minimization in refrigerating and air conditioning equipment is a key issue for the new environmental challenges. Mini microfin tubes represent an optimal solution for both heat transfer enhancement and charge minimization tasks. This paper presents an experimental study of R1234ze(E) flow boiling inside a mini microfin tube with internal diameter at the fin tip of 3.4 mm. The experimental measurements were carried out at constant saturation temperature of 30 °C, by varying the refrigerant mass velocity between 190 kg m−2 s−1 and 940 kg m−2 s−1, the vapour quality from 0.2 to 0.99 at three different heat fluxes: 10, 25, and 50 kW m−2. The experimental results are then compared with those obtained for the more traditional R134a.  相似文献   

5.
New enhanced boiling tubes from Wolverine Tube Inc. (Turbo-B5) and Wieland-Werke AG (Gewa-B5) were investigated using R-134a and R-236fa as test fluids. The tests were done at saturation temperatures of 5 and 15 °C, mass flow rates from 4 to 35 kg m−2 s−1 and heat fluxes from 15 to 70 kW m−2. A new prediction method based on a theoretical analysis of thin film evaporation was used to propose a new correlating parameter. A large new database of local heat transfer coefficients was obtained and utilized to generate an improved prediction method for bundle boiling and the onset of dryout. Onset of dryout and the simultaneous reduction in heat transfer performance occurred at very high vapour quality on these enhanced tubes in convective bundle boiling. Furthermore, a direct comparison was made between the tubes operating in falling film and convective bundle boiling modes.  相似文献   

6.
This paper investigates the effects of heat flux, saturation temperature, and outlet conditions on HFO1234ze(E) boiling inside a Brazed Plate Heat Exchanger (BPHE). The effect of the heat flux on the heat transfer coefficients was remarkable. Similar consideration applies for outlet condition effects whereas the impact of saturation temperature was found to be lower. The frictional pressure drop shows a linear dependence on the refrigerant kinetic energy per unit volume. The two-phase flow boiling heat transfer coefficients were compared with a new model for refrigerant boiling inside BPHE (Longo et al., 2015): the mean absolute percentage deviation between calculated and experimental data is 7.2%. The present data points were compared with those of HFC134a and HFO1234yf previously measured inside the same BPHE under the same operating conditions: HFO1234ze(E) exhibits heat transfer coefficients very similar to HFC134a and HFO1234yf and frictional pressure drops slightly higher than HFC134a and HFO1234yf.  相似文献   

7.
In this study, nucleate boiling heat transfer coefficients (HTCs) of five flammable refrigerants of propylene (R1270), propane (R290), isobutane (R600a), butane (R600), and dimethylether (RE170) were measured at the liquid temperature of 7 °C on a low fin tube of 1023 fins per meter, Turbo-B, and Thermoexcel-E tubes. All data were taken from 80 to 10 kW m−2 with an interval of 10 kW m−2 in the decreasing order of heat flux. Flammable refrigerants' data showed a typical trend that nucleate boiling HTCs obtained on enhanced tubes also increase with the vapor pressure. Fluids with lower reduced pressure such as DME, isobutene, and butane took more advantage of the heat transfer enhancement mechanism of enhanced tubes than those with higher reduced pressure such as propylene and propane. Finally, Thermoexcel-E showed the highest heat transfer enhancement ratios of 2.3–9.4 among the tubes tested due to its sub-channels and re-entrant cavities.  相似文献   

8.
Nuclate pool boiling heat transfer coefficients (HTCs) of HCFC123, CFC11, HCFC142b, HFC134a, CFC12, HCFC22, HFC125 and HFC32 on a horizontal smooth tube of 19.0 mm outside diameter have been measured. The experimental apparatus was specially designed to accomodate high vapor pressure refrigerants such as HFC32 and HFC125 with a sight glass. A cartridge heater was used to generate uniform heat flux on the tube. Data were taken in the order of decreasing heat flux from 80 to 10 kW m−2 with an interval of 10 kW m−2 in the pool of 7 °C. Test results showed that HTCs of HFC125 and HFC32 were 50–70% higher than those of HCFC22 while HTCs of HCFC123 and HFC134a were similar to those of CFC11 and CFC12 respectively. It was also found that nucleate boiling heat transfer correlations available in the literature were not good for certain alternative refrigerants such as HFC32 and HCFC142b. Hence, a new correlation was developed by a regression analysis taking into account the variation of the exponent to the heat flux term as a function of reduced pressure and some other properties. The new correlation showed a good agreement with all measured data including those of new refrigerants of significantly varying vapor pressures with a mean deviation of less than 7%.  相似文献   

9.
This paper presents a model of shell and tube evaporator with micro-fin tubes using R1234yf and R134a. The model developed for this evaporator uses the ε-NTU method to predict the evaporating pressure, the refrigerant outlet enthalpy and the outlet temperature of the secondary fluid. The model accuracy is evaluated using different two-phase flow boiling correlations for micro-fin tubes and comparing predicted and experimental data. The experimental tests were carried out for a wide range of operating conditions using R134a and R1234yf as working fluids. The predicted parameter with maximum deviations, between the predicted and experimental data, is the evaporating pressure. The correlation of Akhavan– Behabadi et al. was used to predict flow boiling heat transfer, with an error on cooling capacity prediction below 5%. Simulations, carried out with this validated model, show that the overall heat transfer coefficient of R1234yf has a maximum decrease of 10% compared with R134a.  相似文献   

10.
In this study, external condensation heat transfer coefficients (HTCs) are measured for nonazeotropic refrigerant mixtures (NARMs) of HFC32/HFC134a and HFC134a/HCFC123 on a low fin and Turbo-C tubes. All measurements are taken at the vapor temperature of 39 °C with the wall subcooling of 3–8 °C. Test results showed that condensation HTCs of NARMs on enhanced tubes were severely degraded from the ideal values showing up to 96% decrease. HTCs of the mixtures on Turbo-C tube were degraded more than those on low fin tube such that HTCs of the mixtures at the same composition were similar regardless of the tube. The mixture with larger gliding temperature differences (GTDs), HFC134a/HCFC123, showed a larger heat transfer reduction from the ideal values than the mixture with smaller GTDs, HFC32/HFC134a. Heat transfer enhancement ratios of the enhanced tubes with NARMs were almost 2 times lower than those with pure refrigerants and they decreased more as the GTDs of the mixtures increased.  相似文献   

11.
为了满足逐步严苛的环保法规要求,R1234yf成为车用热泵制冷剂R134a的热门替代制冷剂之一。本文对R1234yf热泵技术的研究进行了综述与分析,其GWP<1,各方面性质均符合车用热泵系统的工作需求。在传热效果上,R1234yf的沸腾传热性能略优于R134a,且冷凝过程压降比R134a低5%~10%,优于R134a系统。在诸多R1234yf和R134a系统的仿真和实验研究中,R1234yf热泵性能略低于R134a,但可以通过优化零部件、强化补气、改善工况等方式使其与R134a十分接近甚至超越。R1234yf低压饱和压力比R134a高约15%,可以适配更高的压缩机转速,低温下制热性能比R134a更好,且较低的压缩机排气温度使系统工作更为稳定,强化补气的效果也优于R134a。因此,R1234yf在车用热泵中具有较好的工作性能和发展前景,可以作为R134a的替代制冷剂。  相似文献   

12.
This paper presents the comparative performance analysis of the low GWP refrigerants HFO1234yf, HFO1234ze(E) and HC600a inside a commercial roll-bond evaporator for household refrigerators. The vaporisation performances were evaluated at two evaporation temperatures, −15 and −20 °C, and different refrigerant mass flow rates and compared with those of the traditional refrigerant for domestic refrigeration HFC134a. The performance analysis was carried out using both thermocouples installed on the rear side of the roll-bond evaporator and an IR thermo-camera. Each of the low GWP refrigerants tested can be considered a good substitute for HFC134a, provided that the compressor displacement is adjusted to deliver the proper refrigerant mass flow rate. Only HFO1234yf exhibits performance similar to HFC134a at the same mass flow rate, therefore it can be considered a direct drop-in substitute for HFC134a.  相似文献   

13.
Flow boiling of a potential refrigerant R32/R1234ze(E) in a horizontal microfin tube of 5.21 mm inner diameter is experimentally investigated. The heat transfer coefficient (HTC) and pressure drop are measured at a saturation temperature of 10 °C, heat fluxes of 10 and 15 kW m?2, and mass velocities from 150 to 400 kg m?2 s?1. The HTC of R1234ze(E) is lower than that of R32. Degradation in the HTC of the R32/R1234ze(E) mixture is significant; the HTC is even lower than that of R1234ze(E). The HTC is minimized at the composition 0.2/0.8 by mass, where the temperature glide and the mass fraction distribution are maximized. A predicting correlation based on Momoki et al. (1995) associated with the correction methods of Thome (1981) to consider the mass transfer resistance and Stephan (1992) to consider the additionally required sensible heat is proposed and validated with the experimental results.  相似文献   

14.
Nucleate boiling heat transfer coefficients (HTCs) of binary and ternary mixtures composed of HFC32, HFC125, and HFC134a on a horizontal smooth tube of 19.0 mm outside diameter were measured. A cartridge heater was used to generate uniform heat flux on the tube. Data were taken in the order of decreasing heat flux from 80 kW m−2 to 10 kW m−2 with an interval of 10 kW m−2 in the pool temperature at 7 °C. HTCs of nonazeotropic mixtures of HFC32/HFC134a, HFC125/HFC134a, and HFC32/HFC125/HFC134a showed a reduction of HTCs as much as 40% from the ideal values while the near azeotropic mixture of HFC32/HFC125 did not show the reduction. Four of the well known correlations were compared against the present data for binary mixtures. Stephan and Körner's and Schlünder's correlations yielded a good agreement with a deviation of less than 10% but they can not be easily extended to multi-component mixtures of more than three components. A new correlation was developed utilizing only the phase equilibrium data and physical properties. A regression analysis was carried out to account for the reduction of HTCs and the final correlation, which can be easily extended to multi-component mixtures of more than three components, yielded a deviation of 7% for all binary and ternary mixtures.  相似文献   

15.
Condensation is usually assumed to begin when the bulk enthalpy reaches the saturated vapor enthalpy, which leads to discontinuity of heat transfer coefficient calculation in modeling. This paper addresses the discontinuity by showing the presence of condensation in desuperheating region when the wall temperature decreases below the saturation temperature at any operating condition. The experiments have been conducted with R134a, R1234ze(E) and R32 for mass fluxes of 100–300 kgm−2 s−1, saturation temperatures of 30°C–50 °C and from x = 0.05 to superheat of 50 °C in a horizontal smooth tube with 6.1 mm inner diameter. R134a is observed to have approximately 10% higher and 20% lower HTC compared to R1234ze(E) and R32 respectively. Cavallini correlation predicted the data within an accuracy of 12% while Kondo-Hrnjak correlation predicted HTC for condensation in de-superheating zone within accuracy of 23%.  相似文献   

16.
Thermal characteristics of ammonia flow boiling in a microfin plate evaporator are experimentally investigated. Titanium microfin heat transfer surface is manufactured to enhance boiling heat transfer. Longitudinally- and laterally-microfined surfaces are used and those performances are compared. Heat transfer coefficient of microfin plate evaporator is also compared with that of plain-surface plate evaporator. The effects of mass flux, heat flux, channel height, and saturation pressure on heat transfer coefficient are presented and discussed. The experiments are conducted for the range of mass flux (5 and 7.5 kg m−2 s−1), heat flux (10, 15, and 20 kW m−2), channel height (1, 2, and 5 mm), and saturation pressure (0.7 and 0.9 MPa). Heat transfer coefficient is compared with that predicted by available empirical correlations proposed by other researchers. Modified correlations using Lockhart-Martinelli parameter to predict heat transfer coefficient are developed and they cover more than 87% of the experimental data.  相似文献   

17.
The EU Regulation No 517/2014 is going to phase-out most of the refrigerants commonly used in refrigeration and air conditioning systems (R134a, R404A and R410A) because of their extended use and their high GWP values. There are very different options to replace them; however, no refrigerant has yet imposed. In this paper we review and analyze the different mixtures proposed by the AHRI as alternative refrigerants to those employed currently. These mixtures are composed by HFC refrigerants: R32, R125, R152a and R134a; and HFO refrigerants: R1234yf and R1234ze(E). It is concluded, from the theoretical analysis, that most of the new HFO/HFC mixtures perform under the HFC analyzed (although some experimental studies show the contrary) and, in most cases, do not meet the GWP restrictions approved by the European normative. Furthermore, some of the mixtures proposed would have problems due to their flammability.  相似文献   

18.
The evaporative two-phase heat transfer coefficient of CO2/oil contaminated as a refrigerant under forced flow conditions through a smooth horizontal tube was experimentally investigated. The experiments were carried out for two test sections of evaporators. The test sections were made of seamless precision steel tubes with a length of 1.12 m and two inner diameters of 4 and 10 mm to fulfill the influence of the evaporator geometry. Experimental parameters include mass fluxes varied from 90 to 750 (kg m−2 s), heat flux ranged from 5 to 40 (kW m−2), evaporation temperatures changed from −10 to −35 °C, and the oil concentration is varied from 0.2 to 7 %. The results from the experiment are compared with those calculated from correlations reported in the literature. The results of this study are of technological importance for the efficient design of evaporators when systems are assigned to utilize CO2 as a refrigerant.  相似文献   

19.
The vapor viscosities of the new refrigerant R1234yf and its binary mixtures, R32+R1234yf, R125+R1234yf, were measured at atmospheric pressure with a falling-ball-type viscometer. The combined expanded uncertainty of the measurement apparatus was less than 1.5%. The binary mixtures consisted of 20.0, 30.0, 40.0, and 50.0 wt% R32 for R32+R1234yf and of 20.0, 35.0, 50.0, and 70.0 wt% R125 for R125+R1234yf. The viscosities of R1234yf were correlated with the Chapman–Enskog gas kinetic theory and those of binary mixtures were correlated with the Wilke mixture rule. The average absolute deviation (AAD) is 0.189% for R32+R1234yf and 1.169% for R125+R1234yf. The deviations of experimental viscosities of the binary mixtures from data calculated using RefProp v9.1 were also obtained. The AAD is 0.555% for R32+R1234yf and 1.479% for R125+R1234yf.  相似文献   

20.
R1234ze(E), trans-1, 3, 3, 3-tetrafluoropropene, is a fluorinated propene isomer which may be a substitute of R134a for refrigeration applications. R1234ze(E) has a much lower GWP100-years than that of R134a. In this paper, the local heat transfer coefficient during condensation of R1234ze(E) is investigated in a single minichannel, horizontally arranged, with hydraulic diameter equal to 0.96 mm. Since the saturation temperature drop directly affects the heat transfer rate, the pressure drop during adiabatic two phase flow of R1234ze(E) is also measured. Predictive models are assessed both for condensation heat transfer and pressure drop. A comparative analysis is carried out among several fluids (R1234ze(E), R32, R134a and R1234yf) starting from experimental data collected at the same conditions and using the Performance Evaluation Criteria (PEC) named Penalty Factor (PF) and Total Temperature Penalization (TTP) to rank the tested refrigerants in forced convective condensation.  相似文献   