首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents the results of an experimental study on the seismic performance of axially loaded reinforced concrete (RC) walls with boundary elements confined by limited transverse reinforcement. These specimens were initially subjected to axial compression loading and cyclic lateral loading to failure, and subsequently repaired and subjected to loading again. The test specimens include two low-rise walls of aspect ratio 1.125 and two medium-rise walls of aspect ratio 1.625. Results show that significant drift capacities were achieved from the strengthened walls. The performance of the repaired walls was similar to the original walls before repair in terms of the flexural behavior, shear strength, and ductility capacities. While the fiber-reinforced polymer (FRP) anchorage may undergo premature failure, it however failed only after the peak lateral strength of the repaired wall was attained. This paper demonstrates that repair of damaged RC walls using FRP is able to restore the performance of damaged RC walls while also serving as repair method of relative ease.  相似文献   

2.
The seismic performance of composite steel plate shear walls (CSPSWs) that consist of a steel plate shear wall (SPSW) with reinforced concrete (RC) panels attached to one or both sides by means of bolts or connectors is experimentally studied. The shear wall is connected to the frame beams but not to the columns. This arrangement restrains the possible outof-plane buckling of the thin-walled steel plate, thus significantly increasing the bearing capacity and ductility of the overall wall, and prevents the premature overall or local buckling failure of the frame columns. From a practical viewpoint, these solutions can provide open space in a floor as this type of composite shear walls with a relatively small aspect ratio can be placed parallel along a bay. In this study, four CSPSWs and one SPSW were tested and the results showed that both CSPSWs and SPSW possessed good ductility. For SPSW alone, the buckling appeared and resulted in a decrease of bearing capacity and energy dissipation capacity. In addition, welding stiffeners at comers were shown to be an effective way to increase the energy dissipation capacity of CSPSWs.  相似文献   

3.
In 2003, an experimental research program was initiated at the American University of Beirut with the objectives of (1) evaluating the effectiveness of external fiber-reinforced polymer (FRP) confinement in improving the bond strength of spliced reinforcement in reinforced-concrete (RC) columns and its implications on the lateral load capacity and ductility of the columns under seismic loading; and (2) establishing rational design criteria for bond strengthening of spliced reinforcement using external FRP jackets. This paper presents a discussion of recent experimental results dealing with rectangular columns and the results of a pilot study conducted on circular columns with particular emphasis on aspects related to the bond strength of the spliced column reinforcement. A nonlinear analysis model is developed for predicting the envelope load–drift response, taking into account the effect of FRP confinement on the stress–strain behavior of concrete in compression. Results predicted by the model showed excellent agreement with the test results. Design expressions of the bond strength of spliced bars in FRP-confined concrete were assessed against the current experimental data, and a criterion for seismic FRP strengthening of bond-critical regions in RC members is proposed.  相似文献   

4.
Despite the improved performance of fiber-reinforced plastic (FRP)-retrofitted bridges, residual deformations in the event of an earthquake are inevitable. Little consideration is currently given to these deformations when assessing seismic performance. Moreover, important structures are currently required not only to have high strength and high ductility but also to be usable and repairable after high intensity earthquakes. This paper presents a definition of an FRP-RC damage-controllable structure. An intensive study of 109 bridge columns, extracted from recent research literature on the inelastic performance of FRP retrofitted columns with lap-splice deficiencies, flexural deficiencies, or shear deficiencies, is used to evaluate the recoverability of such retrofitted columns. The residual deformation, as a seismic performance measure, is used to evaluate the performance of 39 FRP-retrofitted RC columns from the available database. Based on this evaluation, a requirement for the recoverable and irrecoverable states of FRP-RC bridges is specified. Finally, the Seismic Design Specifications of Highway Bridges for RC piers is adapted to predict the residual deformations of FRP-RC columns.  相似文献   

5.
Hollow core reinforced concrete columns are generally preferred in use to decrease the cost and weight/stiffnesss ratio of members, such as bridge columns and piles. With a simplified stress state assumption, strengthening a hollow core reinforced concrete column with fiber-reinforced polymer (FRP) wrapping provides a biaxial confinement to the concrete, which leads to a need of defining the effect of FRP wrapping on the strength and ductility of the hollow core reinforced concrete columns. In this study, two groups of four hollow core reinforced concrete columns (205?mm outer diameter, 56?mm hollow core diameter, and 925?mm height) were tested under concentric, eccentric (25 and 50?mm eccentricity) and bending loads to observe the effect of carbon FRP (CFRP) wrapping. All the columns had internal steel reinforcement. Half of the columns had three layers of circumferential CFRP wrapping, whereas the other half had no external confinement. Axial load-bending moment (P–M) diagrams of each group were drawn using the obtained experimental results for both groups. It was observed that, CFRP wrapped columns had higher load and moment carrying capacities than the other group. An analytical model is proposed for drawing the P–M diagram of CFRP wrapped hollow core reinforced concrete columns.  相似文献   

6.
This paper presents the results of experimental program and analytical modeling for performance evaluation of a fiber-reinforced polymer (FRP) wrapping system to upgrade eccentrically loaded reinforced concrete (RC) columns. A total of 12 RC columns with end corbels were tested. The test specimen had an overall length of 1,200?mm. Each end corbel had a cross section of 250×250?mm and a length of 350?mm. The specimen in the test region was 125×125?mm having a longitudinal steel ratio of 1.9%. Test parameters included confinement condition (no wrapping, full FRP wrapping, and partial FRP wrapping), and eccentricity-to-section height (e/h) ratio (0.3, 0.43, 0.57, and 0.86). Research findings indicated that the strength gain caused by FRP wrapping decreased as e/h was increased. Full FRP wrapping resulted in about 37% enhancement in compression strength at a nominal e/h of 0.3, whereas only 3% strength gain was recorded at a nominal e/h of 0.86. The compression strengths of the partially wrapped columns were on average 5% lower than those of the fully wrapped columns. A nonlinear, second-order analysis that accounts for the change in eccentricity caused by the lateral deformation was proposed to predict the columns strength. A comparison between analytical and experimental results of the present study in addition to data published in the literature demonstrated the accuracy and validity of the proposed analysis.  相似文献   

7.
Numerous recent research findings evidenced the success of retrofitting existing RC columns using fiber-reinforced plastic (FRP) jacketing. However, little is known about the residual performance of FRP-retrofitted RC columns following limited seismic damage. In this paper, the residual performance of FRP-retrofitted columns damaged after simulated seismic loading is studied. Eight model columns with a shear aspect ratio of 5.0 were tested first under cyclic lateral force and a constant axial load equal to 20% of the column gross axial load capacity. The main parameters considered were the type of FRP jacket and peak drift ratio where the lateral loading was interrupted. Glass fiber-reinforced plastic (GFRP) and carbon fiber-reinforced plastic (CFRP) were both used for retrofitting. Five of the model columns were subjected to long-term axial loading after being subjected to limited damage by lateral cyclic loading. From the results of long-term loading test, it was found that FRP-retrofitted columns had much smaller creep deformation than the counterpart as-built model. The deformation of retrofitted columns under long-term axial loading depended on the previous damage intensity and the modulus of elasticity of FRP. The effective creep Poisson’s ratios of the retrofitted columns were much smaller than the as-built column but identical for GFRP and CFRP retrofitted columns. Under the testing conditions of this study, the long-term axial deformation of retrofitted columns tends to be sufficiently stable, despite the simulated earthquake damage.  相似文献   

8.
The rehabilitation of RC columns jacketed with carbon fiber-reinforced plastic (FRP) composites for improving shear strength, confinement, and ductility has received considerable attention. However, research for improving the shear capacity of beam-column T-joints using FRP composite materials is still in the early stages. The present paper describes the experimental results of 14 1∕3-scale tests of concrete beam-column joints. The variables considered were the composite system, the fiber orientation, and the surface preparation. The tests have demonstrated the viability of carbon FRP composites for their use in improving the shear capacity of the joints as evidenced by the experimental results. Based on these experimental results, a design aid was developed for T-joints with inadequate confinement and shear reinforcement.  相似文献   

9.
A set of column-footing subassemblies were prepared to investigate construction feasibility and seismic performance of structural joints for concrete-filled fiber reinforced polymer (FRP) tubes (CFFT) as bridge substructure. Based on the common practices of the precast industry and previous research on CFFT, the test matrix included a control reinforced concrete (RC) column and three CFFT columns, all with similar RC footings. The three CFFT columns included a cast-in-place CFFT column with starter bars, a precast CFFT column with grouted starter bars, and a precast CFFT column with unbonded posttensioned rods. The columns were subjected to a constant axial load and a pseudostatic lateral load. All proposed joints proved feasible in construction and robust under extreme load conditions. FRP tube, when secured properly in the footing, showed great influence on the seismic performance of the column by providing both longitudinal reinforcement and hoop confinement to the core concrete. The CFFT columns exhibited significant improvement over traditional RC columns in both ultimate strength and ductility. The study also showed that practices of the precast concrete industry can be easily and effectively implemented for the CFFT column construction.  相似文献   

10.
The paper aims to contribute to a better understanding and modeling of the shear behavior of reinforced-concrete (RC) beams strengthened with carbon fiber reinforced polymer (FRP) sheets. The study is based on an experimental program carried out on 11 beams with and without transverse steel reinforcement, and with different amounts of FRP shear strengthening. The test results provide some new insights into the complex failure mechanisms that characterize the ultimate shear capacity of RC members with transverse steel reinforcement and FRP sheets. After the discussion of the above topics, a new upper bound of the shear strength is introduced. It should be capable of taking into account how the cracking pattern in the web failing under shear is modified by the presence of FRP sheets, and how such a modified cracking pattern actually modifies the anchorage conditions of the sheets and their effective contribution to the ultimate shear strength of the beams.  相似文献   

11.
Seismic Retrofit of Hollow Rectangular Bridge Columns   总被引:1,自引:0,他引:1  
The seismic performance of rectangular hollow bridge columns is a significant issue of the high-speed rail project in Taiwan. The flexural ductility and shear capacity of such columns with the configuration of lateral reinforcement used in Taiwan have been studied recently. This paper reports that hollow rectangular bridge columns retrofitted with fiber-reinforced polymer (FRP) sheets were tested under a constant axial load and a cyclically reversed horizontal load to investigate their seismic behavior, including flexural ductility, dissipated energy, and shear capacity. An analytical model was also developed to predict the moment-curvature curve of sections and the load-displacement relationship of columns. Based on the test results, the seismic behavior of such columns will be presented. The test results were also compared to the proposed analytical model. It was found that the ductility factors of the tested piers are in the range from 3.4 to 6.3, and the proposed analytical model can predict the load-displacement relationship of such columns with acceptable accuracy. All in all, FRP sheets can effectively improve both the ductility factor and shear capacity of hollow rectangular bridge columns.  相似文献   

12.
The seismic performance of reinforced concrete frames designed for gravity loads is evaluated experimentally using a shake table. Two 1:3 scale models of one-bay, three-storied space frames, one without infill and the other with a brick masonry infill in the first and second floors, are tested under excitation equivalent to the spectrum given in IS 1893-2002. From the measured response of the models during excitation, the shear force, interstory drift, and stiffness are evaluated. The effect of masonry infill on the seismic performance of reinforced concrete frames is also investigated. Then, the frames are tested to failure. Severe damage is observed in the columns in the ground floor. The damaged columns are strengthened by a reinforced concrete jacket. The frames are again tested under the same earthquake excitations. The test results showed that the retrofitted frames could sustain low to medium seismic forces due to a significant increase in strength and stiffness.  相似文献   

13.
In recent years, fiber-reinforced polymer (FRP) wrapping effectiveness has been clearly confirmed especially with reference to concrete structures. Despite evident advantages of FRP based confinement on members subjected to compressive overloads due to static or seismic actions, the use of such technique in the field of masonry has not been fully explored. Thus, to assess the potential of confinement of masonry columns, the present paper shows the results of an experimental program dealing with 18 square cross sections (listed faced tuff or clay brick) masonry scaled columns subjected to uniaxial compression load. In particular, three different confinement solutions have been experimentally analyzed in order to evaluate and compare the effectiveness of uniaxial glass FRP, carbon FRP, and basalt FRP laminates wrapping. The main experimental outcomes are presented and discussed in the paper considering mechanical behavior of specimens, axial stress-axial strain relationships, and effective strains at failure on the reinforcement. Test results have showed that the investigated confining systems are able to provide significant gains both in terms of compressive strength and ductility of masonry columns. Results of the presented experimental activity along with data available in the literature have been finally used to assess the reliability of the main existing analytical models; refined equations have been then proposed to minimize the scattering between theoretical predictions and experimental available data.  相似文献   

14.
Steel-fiber-reinforced polymer (FRP) composite bars (SFCBs) are a novel reinforcement for concrete structures. Because of the FRP’s linear elastic characteristic and high ultimate strength, they can achieve a stable postyield stiffness even after the inner steel bar has yielded, which subsequently enables a performance-based seismic design to easily be implemented. In this study, lateral cyclic loading tests of concrete columns reinforced either by SFCBs or by ordinary steel bars were conducted with axial compression ratios of 0.12. The main variable parameters were the FRP type (basalt or carbon FRP) and the steel/FRP ratio of the SFCBs. The test results showed the following: (1)?compared with ordinary RC columns, SFCB-reinforced concrete columns had a stable postyield stiffness after the SFCB’s inner steel bar yielded; (2)?because of the postyield stiffness of the SFCB, the SFCB-reinforced concrete columns exhibited less column-base curvature demand than ordinary RC columns for a given column cap lateral deformation. Thus, reduced unloading residual deformation (i.e., higher postearthquake reparability) of SFCB columns could be achieved; (3)?the outer FRP type of SFCB had a direct influence on the performance of SFCB-reinforced concrete columns, and concrete columns reinforced with steel-basalt FRP (BFRP) composite bars exhibited better ductility (i.e., a longer effective length of postyield stiffness) and a smaller unloading residual deformation under the same unloading displacement when compared with steel-carbon FRP (CFRP) composite bar columns; (4)?the degradation of the unloading stiffness by an ordinary RC column based on the Takeda (TK) model was only suitable at a certain lateral displacement. In evaluating the reparability of important structures at the small plastic deformation stage, the TK model estimated a much smaller residual displacement, which is unsafe for important structures.  相似文献   

15.
This paper deals with the shear strengthening of RC beams using externally bonded (EB) fiber-reinforced polymers (FRP). Current code provisions and design guidelines related to shear strengthening of RC beams with FRP are discussed in this paper. The findings of research studies, including recent work, have been collected and analyzed. The parameters that have the greatest influence on the shear behavior of RC members strengthened with EB FRP and the role of these parameters in current design codes are reviewed. This study reveals that the effect of transverse steel on the shear contribution of FRP is important and yet is not considered by any existing codes or guidelines. Therefore, a new design method is proposed to consider the effect of transverse steel in addition to other influencing factors on the shear contribution of FRP (Vf). Separate design equations are proposed for U-wrap and side-bonded FRP configurations. The accuracy of the proposed equations has been verified by predicting the shear strength of experimentally tested RC beams using data collected from the literature. Finally, comparison with current design guidelines has shown that the proposed model achieves a better correlation with experimental results than current design guidelines.  相似文献   

16.
The results of a research program that evaluated the confinement effectiveness of the type and the amount of fiber-reinforced polymer (FRP) used to retrofit circular concrete columns are presented. A total of 17 circular concrete columns were tested under combined lateral cyclic displacement excursions and constant axial load. It is demonstrated that a high axial load level has a detrimental effect and that a large aspect ratio has a positive effect on drift capacity. Compared with the performance of columns that are monotonically loaded until failure, three cycles of every displacement excursion significantly affect drift capacity. The energy dissipation capacity is controlled by FRP jacket confinement stiffness, especially under a high axial load level. The fracture strain of FRP material has no significant impact on the drift capacity of retrofitted circular concrete columns as long as the same confining pressure is provided, which differs from the common opinion that a larger FRP fracture strain is advantageous in seismic retrofitting. The amount of confining FRP greatly affects the length of the plastic hinge region and the drift capacity of FRP-retrofitted columns. A further increase in confinement after a critical value causes a reduction in the deformation capacity of the columns.  相似文献   

17.
This paper explores a new hybrid fiber-reinforced polymer (FRP) sheet/ductile anchor system for rehabilitation of reinforced concrete (RC) beams. The advantages of the proposed strengthening method is that it overcomes the problem of low ductility that is associated with brittle failure mode in conventional methods of strengthening beams using epoxy-bonded FRP sheets. The proposed system leads to a ductile failure mode by triggering yielding to occur in a steel anchor system (steel links) rather than by rupture or debonding of FRP sheets, which is sudden in nature. Four half-scale RC T-beams were tested under four-point bending. Three retrofitted beams were strengthened using one layer of carbon FRP sheet. The results of the two beams that were strengthened with the new hybrid FRP sheet/ductile anchor system were compared with the results from the beam strengthened with conventional FRP bonding method and the control beam. The results show the effectiveness of the proposed strengthening system in increasing flexural capacity and ductility of RC beams.  相似文献   

18.
Repair, strengthening, and retrofit of reinforced and prestressed concrete members have become increasingly important issues as the World’s infrastructure deteriorates with time. Buildings and bridges are often in need of repair or strengthening to accommodate larger live loads as traffic and building occupancies change. In addition, inadequate design and detailing for seismic and other severe natural events has resulted in considerable structural damage and loss of life, particularly in reinforced concrete buildings. Numerous buildings and bridges suffer damage during such events and need to be repaired. The use of carbon fiber reinforced polymer (CFRP) composite fabric bonded to the surface of concrete members is comparatively simple, quick and virtually unnoticeable after installation. The use of composites has become routine for increasing both the flexural and shear capacities of reinforced and prestressed concrete beams. Earthquake retrofit of bridge and building structures has relied increasingly on composite wrapping of columns, beams and joints to provide confinement and increase ductility. This paper presents the results of cyclic testing of three large-scale reinforced concrete slab–column connections. Each of the specimens was a half-scale model of an interior slab–column connection common to flat-slab buildings. The specimens were reinforced according to ACI-318 code requirements and included slab shear reinforcement. While supporting a slab gravity load equivalent to dead load plus 30% of the live load, the specimens were subjected to an increasing cyclic lateral loading protocol up to 5% lateral drift. The specimens were subjected to the same loading protocol after they were repaired with epoxy crack sealers and CFRP sheet on the surfaces of the slab. Repair with epoxy and CFRP on the top surface of the slab was able to restore both initial stiffness and ultimate strength of the original specimen.  相似文献   

19.
Advancements in fiber-reinforced polymers (FRPs) have made this an attractive material for rehabilitation and strengthening of bridge superstructures. FRP has primarily been used with the intention of increasing the bending strength of bridge members. However, this paper investigates the use of externally placed FRP strips to increase shear capacity of short-span, 5.7?m (19?ft), precast concrete channel beam bridges. A statewide survey revealed that as many as 389 bridges in the state of Arkansas are comprised of these members. Notably, beams within these bridges were designed under provisions that did not require shear reinforcement. In this research, four sections were retrofitted using carbon fiber-reinforced polymer (CFRP) strips and load tested to failure to measure the repair effectiveness. The performance of the retrofitted sections far exceeded that of unretrofitted sections. It was concluded that the addition of the CFRP repair increased the deflection ductility at least 123%. In addition, beams retrofitted with the CFRP strips experienced at least 26% more deflection after the initiation of a shear crack; therefore reducing the risk of a catastrophic failure.  相似文献   

20.
The encasement of concrete in fiber-reinforced polymer (FRP) composite jackets can significantly increase the compressive strength and strain ductility of concrete columns and the structural system of which the columns are a part, be it a building or a bridge. Due to the approximate bilinear compressive behavior of FRP-confined concrete, analysis and design of FRP-confined concrete members requires an accurate estimate of the performance enhancement due to the confinement provided by FRP composite jackets. An analytical model is presented for predicting the bilinear compressive behavior of concrete confined with either bonded or nonbonded FRP composite jackets. This article describes the basis of the model, which is a variable plastic strain ductility ratio. The variable plastic strain ductility ratio defines the increase in plastic compressive strain relative to the increase in the plastic compressive strength of the FRP-confined concrete, which is a function of the hoop stiffness of the confining FRP composite jacket, the plastic dilation rate, and the type of bond between the FRP composite and concrete.  相似文献   