首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
For providing good performance of dehumidifier and regenerator with certain dimensions, a new type of internally cooled/heated dehumidifier/regenerator based on the plate–fin heat exchanger (PFHE) was designed. To investigate the behavior of the new equipment, an experimental setup was established in an environment chamber with regulable temperature and humidity air. By the internally cooled dehumidification testing, effects of the cooling water temperature, the air flow rate and the desiccant temperature on the dehumidification performance and the cooling efficiency were presented. The behavior of internally cooled dehumidification process was compared with that of the adiabatic dehumidification process. The results suggested that the cooling efficiency decreased with the increasing of the cooling water temperature and desiccant with low temperature could bring more mass transfer coefficients. There is an optimal air flow rate to achieve the maximum absolute humidity decrease of the air. By the internally heated regeneration testing, effects of the air flow rate and the desiccant inlet temperature on the regeneration performance and air outlet parameters were discussed and also compared with those of the adiabatic regeneration process. It was concluded that the regeneration efficiency of internally heated regeneration was more than that of the adiabatic regeneration, and the internally heated regenerator could offer better thermal performance.  相似文献   

2.
Evaporative cooling is used in industrial and air conditioning processes to reduce temperature in different fluids. Direct evaporation systems can lead to environmental problems such as Legionnaire's disease, and indirect systems reduce system efficiency.This work presents the manufacture, test bed set up and trials carried out on a ceramic evaporative cooling system which acts as a semi-indirect cooler. Depending on air characteristics, it may act as a sensible or enthalpic exchanger. The water cooled in a cooling tower, using the return air coming from the conditioned room (22 °C and 50% comfort conditions) goes through the ceramic pipes, exchanging sensible and latent heat with a current of outdoor air.The use of this recovery system is mainly in climates with a high temperature and humidity such as tropical environments where the system yields a decrease in supply air humidity, using the cooling power of return air.The tests presented show the system behaviour for various supply air conditions.  相似文献   

3.
The paper is aimed to develop a high performance rotary solid desiccant cooling system using a novel compound desiccant wheel (DW). The unique feature of the desiccant wheel is that it can work well under a lower regeneration temperature and have a higher dehumidification capacity due to the contribution of the new compound desiccant materials. Experimental results indicate that the novel desiccant wheel under practical operation can remove more moisture from the process air by about 20–40% over the desiccant wheel employing regular silica gel. A mathematical model that is used to predict the system performance has been validated with the test results. By integrating the desiccant wheel with evaporative cooling, heat recovery and heating for regeneration sections, a solid desiccant cooling system can be formed. Simulation results show that because of the use of the new compound desiccant, the desiccant cooling system can work under much lower regeneration temperature and have a relative high COP, thus low grade thermal energy resources, such as solar energy, waste heat, etc., can be efficiently utilized to drive such a cooling cycle.  相似文献   

4.
This paper presents heat transfer data for a multiport minichannel heat exchanger vertically mounted as an evaporator in a test-rig simulating a small water-to-water heat pump. The multiport minichannel heat exchanger was designed similar to a shell-and-tube type heat exchanger, with a six-channel tube of 1.42 mm hydraulic diameter, a tube-side heat transfer area of 0.777 m2 and a shell-side heat transfer area of 0.815 m2. Refrigerant propane with a desired vapour quality flowed upward through the tubes and exited with a desired superheat of 1–4 K. A temperature-controlled glycol solution that flowed downward on the shell-side supplied the heat for the evaporation of the propane. The heat transfer rate between the glycol solution and propane was controlled by varying the evaporation temperature and propane mass flow rate while the glycol flow rate was fixed (18.50 l min−1). Tests were conducted for a range of evaporation temperatures from −15 to +10 °C, heat flux from 2000 to 9000 W m−2 and mass flux from 13 to 66 kg m−2 s−1. The heat transfer coefficients were compared with 14 correlations found in the literature. The experimental heat transfer coefficients were higher than those predicted by many of the correlations. A correlation which was previously developed for a very large and long tube (21 mm diameter and 10 m long) was in good agreement with the experimental data (97% of the data within ±30%). Several other correlations were able to predict the data within a reasonable deviation (within ±30%) after some adjustments to the correlations.  相似文献   

5.
This paper reports heat transfer results obtained during condensation of refrigerant propane inside a minichannel aluminium heat exchanger vertically mounted in an experimental setup simulating a water-to-water heat pump. The condenser was constructed of multiport minichannel aluminium tubes assembled as a shell-and-tube heat exchanger. Propane vapour entered the condenser tubes via the top end and exited sub-cooled from the bottom. Coolant water flowed upward on the shell-side. The heat transfer areas of the tube-side and the shell-side of the condenser were 0.941 m2 and 0.985 m2, respectively. The heat transfer rate between the two fluids was controlled by varying the evaporation temperature while the condensation temperature was fixed. The applied heat transfer rate was within 3900–9500 W for all tests. Experiments were performed at constant condensing temperatures of 30 °C, 40 °C and 50 °C, respectively. The cooling water flow rate was maintained at 11.90 l min−1 for all tests. De-superheating length, two-phase length, sub-cooling length, local heat transfer coefficients and average heat transfer coefficients of the condenser were calculated. The experimental heat transfer coefficients were compared with predictions from correlations found in the literature. The experimental heat transfer coefficients in the different regions were higher than those predicted by the available correlations.  相似文献   

6.
A thermodynamic cycle model is used to select an optimum adsorbent-refrigerant pair in respect of a chosen figure of merit that could be the cooling production (MJ m−3), the heating production (MJ m−3) or the coefficient of performance (COP). This model is based mainly on the adsorption equilibrium equations of the adsorbent–refrigerant pair and heat flows. The simulation results of 26 various activated carbon–ammonia pairs for three cycles (single bed, two-bed and infinite number of beds) are presented at typical conditions for ice making, air conditioning and heat pumping applications. The driving temperature varies from 80 °C to 200 °C. The carbon absorbents investigated are mainly coconut shell and coal based types in multiple forms: monolithic, granular, compacted granular, fibre, compacted fibre, cloth, compacted cloth and powder. Considering a two-bed cycle, the best thermal performances based on power density are obtained with the monolithic carbon KOH-AC, with a driving temperature of 100 °C; the cooling production is about 66 MJ m−3 (COP = 0.45) and 151 MJ m−3 (COP = 0.61) for ice making and air conditioning respectively; the heating production is about 236 MJ m−3 (COP = 1.50).  相似文献   

7.
In order to settle the problem of the corrosion between sea water and the steel adsorber for ammonia system, a split heat pipe type adsorption ice making test unit, which use compound adsorbent of CaCl2 and activated carbon to improve the adsorption performance, is designed and constructed. For this test unit there is mass recovery function between two beds and the CaCl2 in compound adsorbent per bed is 1.88 kg, and there is only one pump for the whole heating and cooling phase for adsorbers. Performances of this system are tested; the lowest evaporating temperature is as low as −42 °C. At the evaporating temperature of −35 and −25 °C, the cooling powers are 0.89 and 1.18 kW, respectively. At the evaporating temperature of −15 °C, its average cooling power is 1.37 kW, which corresponds coefficient of performance of refrigeration COP=0.41 and specific cooling power per kilogram CaCl2 of each adsorber SCP=731 W kg−1. The mass recovery process has improved SCP and COP for the system by 15.5 and 24.1%, respectively. Heat transfer performance is also improved by the split heat pipe construction; the average heat transfer coefficient for a whole cycle is 155.8 W m−2 °C−1.  相似文献   

8.
Refrigerant vapor-injection technique has been well justified to improve the performance of systems in refrigeration applications. However, it has not received much attention for air conditioning applications, particularly for air conditioning in hot climates and for heat pumping in cold climates. In this study, the performance of an 11 kW R410A heat pump system with a two-stage vapor-injected scroll compressor was experimentally investigated. The vapor-injected scroll compressor was tested with the cycle options of both flash tank and internal heat exchanger configurations. A cooling capacity gain of around 14% with 4% COP improvement at the ambient temperature of 46.1 °C and about 30% heating capacity improvement with 20% COP gain at the ambient temperature of −17.8 °C were found for the vapor-injected R410A heat pump system as compared to the conventional system which has the same compressor displacement volume.  相似文献   

9.
CO2 flow condensation heat transfer coefficients and pressure drop are investigated for 0.89 mm microchannels at horizontal flow conditions. They were measured at saturation temperatures of −15 and −25 °C, mass fluxes from 200 to 800 kg m−2 s−1, and wall subcooling temperatures from 2 to 4 °C. Flow patterns for experimental conditions were predicted by two flow pattern maps, and it could be predicted that annular flow patterns could exist in most of flow conditions except low mass flux and low vapor quality conditions. Measured heat transfer coefficients increased with the increase of mass fluxes and vapor qualities, whereas they were almost independent of wall subcooling temperature changes. Several correlations could predict heat transfer coefficients within acceptable error range, and from this comparison, it could be inferred that the flow condensation mechanism in 0.89 mm channels should be similar to that in large tubes. CO2 two-phase pressure drop, measured in adiabatic conditions, increased with the increase of mass flux and vapor quality, and it decreased with the increase of saturation temperature. By comparing measured pressure drop with calculated values, it was shown that several correlations could predict the measured values relatively well.  相似文献   

10.
This article experimentally investigates the thermal performance of a thermal battery used in the ice storage air-conditioning system as a subcooler. The thermal battery utilizes the superior heat transfer characteristics of two-phase closed thermosyphon and eliminates the drawbacks found in convectional energy storage systems. Experimental investigations are first conducted to study the thermal behavior of thermal battery under different charge temperatures (−5 °C to −9 °C) in which water is used as the energy storage material. This study also examines the thermal performance of the subcooled ice storage air conditioner under different cooling loads. Experimental data of temperature variation of water, ice fraction, refrigerant mass flow rate and coefficient of performance (COP) are obtained. The results show that supercooling phenomenon appears in the water and it can be ended when the charge temperature is lower than −6 °C. The system gives 28% more cooling capacity and 8% higher COP by the contribution of the thermal battery used as a subcooler.  相似文献   

11.
Energy for air dehumidification and cooling can be stored efficiently and non-dissipatively in liquid desiccants. For optimal storage capacity, new dehumidifiers have been developed and tested, dehumidifying air by a cooled microflow of a hygroscopic aqueous salt solution, e.g. LiClH2O in an almost isothermal absorption process. A small, theoretically sufficient solution flow of about 0.21 l/(hm2) could be distributed uniformly over a cooled exchanger surface. An air dehumidification of 5.5 g/kg and a storage solution has been measured under steady state ARI conditions with an experimental dehumidifier for an air flow of 1000 m3/h.  相似文献   

12.
This study presents a first-principles mathematical model developed to investigate the thermal behavior of a plate-type, roll-bond evaporator. The refrigerated cabinet was also taken into account in order to supply the proper boundary conditions to the evaporator model. The mathematical model was based on the mass, momentum and energy conservation principles applied to each of the following domains: (i) refrigerant flow through the evaporator channels; (ii) heat diffusion in the evaporator plate; and (iii) heat transmission to the refrigerated cabinet. Empirical correlations were also required to estimate the shear stresses, and the internal and external heat transfer rates. The governing partial differential equations were discretized through the finite-volume approach and the resulting set of algebraic equations was solved by successive iterations. Validation of the model against experimental steady-state data showed a reasonable level of agreement: the cabinet air temperature and the evaporator cooling capacity were predicted within error bands of ±1.5 °C and ±6%, respectively.  相似文献   

13.
In this study, the freezing time and rate of 1 cm3 cauliflower floret samples were determined under different freezing conditions in an air blast freezer. Four different air temperatures (−20, −25, −30 and −35°C) and six different air velocities (70, 131, 189, 244, 280 and 293 m min−1) were applied in the freezer, and the freezing rate and time of cauliflower pieces were determined under each condition. The freezing time of cauliflower samples frozen with cold air at −20°C and 280 m min−1 was similar to that of samples frozen with cold air at −35°C and 70 m min−1. When the velocity of air was increased from 70 m min−1 to 293 m min−1, the freezing time was approximately halved.  相似文献   

14.
Different designs of flat-tube heat exchangers with plain fins have been evaluated theoretically in a parameter study in order to evaluate their performance potential in indirectly cooled display cabinets. Two different types of flat-tube heat exchangers were considered; one with serpentine fins and one with continuous plate fins. Both flat-tube heat exchanger types were adapted to the laminar flow regime on the liquid as well as on the air side. The performance of the two heat exchanger types had previously been verified experimentally under dehumidifying conditions. The results from this parameter study show that considerable savings in the required electric drive power to compressors, pumps and fans can be obtained in comparison with the traditional cooling coil. The savings may be up to 15%. In addition, the required temperature difference for the flat-tube heat exchangers is so small that frost-free operation is possible, which would result in even larger savings.  相似文献   

15.
In most domestic and commercial refrigeration systems, frost forms on the air-side surface of the air-to-refrigerant heat exchanger. Frost-tolerant designs typically employ a large fin spacing in order to delay the need for a defrost cycle. Unfortunately, this approach does not allow for a very high air-side heat transfer coefficient, and the performance of these heat exchangers is often air-side limited. Longitudinal vortex generation is a proven and effective technique for thinning the thermal boundary layer and enhancing heat transfer, but its efficacy in a frosting environment is essentially unknown. In this study, an array of delta-wing vortex generators is applied to a plain-fin-and-tube heat exchanger with a fin spacing of 8.5 mm. Heat transfer and pressure drop performance are measured to determine the effectiveness of the vortex generator under frosting conditions. For air-side Reynolds numbers between 500 and 1300, the air-side thermal resistance is reduced by 35–42% when vortex generation is used. Correspondingly, the heat transfer coefficient is observed to range from 33 to 53 W m−2 K−1 for the enhanced heat exchanger and from 18 to 26 W m−2 K−1 for the baseline heat exchanger.  相似文献   

16.
This study proposes dimensionless correlations for predicting the properties of frost formed on a cold plate. Frosting experiments are carried out to obtain the correlations with various environmental parameters including the air temperature, air velocity, absolute humidity, and cooling plate temperature. The thickness, density, surface temperature, effective thermal conductivity, average heat and mass transfer coefficients of the frost layer are correlated as functions of the Reynolds number, Fourier number, absolute humidity, and dimensionless temperature by using a dimensional analysis. The correlations proposed in this study agree well with the experimental data within a maximum error of 10%, and can be used to predict the average frost properties in the following ranges: the air temperature of 5–15 °C, air velocity of 1.0–2.5 m s−1, absolute humidity of 0.00322–0.00847 kg kga−1, and cooling plate temperature of −35–−15 °C.  相似文献   

17.
Desiccant coated heat exchanger provides a promising option for desiccant cooling system, since it can handle sensible load and latent load simultaneously within one component. It is fabricated by coating desiccant material on the surface of conventional fin-tube heat exchanger. In order to enhance the performance of conventional silica gel coated heat exchanger (SGCHE), a novel composite silica gel coated heat exchanger (CCHE) is proposed and fabricated. An experimental setup is built to test and compare the dynamic performance of SGCHE and CCHE. Influences of main operation parameters including water temperatures and inlet air conditions on system performance are analyzed in terms of average dehumidification capacity (Davg) and thermal coefficient of performance (COPth). Optimization of cycle switch modes is also discussed. Experimental results show that CCHE has better dehumidification performance compared with SGCHE. In addition, pre-cooling before dehumidification process is found to be advantageous to both Davg and COPth.  相似文献   

18.
Convection heat transfer to spherical particles inside a hydrofluidisation freezing unit was investigated. The unit contained a food tank with a perforated bottom plate to create agitating jets. An aqueous solution of 30% ethanol+20% glucose was used as the refrigeration medium in a temperature range of −20 to 0 °C and flow rates from 5 to 15 l min−1. The lumped capacitance method was applied on cooling profiles of aluminium spheres of 5–50 mm to obtain surface heat transfer coefficients. Coefficients were within a range of 154–1548 W m−2 °C−1, and depended on diameter, flow rate, refrigeration temperature and fluid agitation level. The agitation due to jets was accounted for by means of an agitation Reynolds number in a Nusselt correlation A large variability of measured surface heat transfer coefficients was observed. This could be attributed to non-constant flow and turbulence fields in the refrigeration medium. The value of the heat transfer coefficient was compared to values determined on strawberries.  相似文献   

19.
Heat transfer and pressure drop characteristics of the Printed Circuit Heat Exchanger (PCHE) were investigated in an experimental supercritical CO2 loop. The inlet temperature and pressure were varied from 280 to 300 °C/2.2 to 3.2 MPa in the hot side and from 90 to 108 °C/6.5 to 10.5 MPa in the cold side while the mass flow rate was varied from 40 to 80 kg h−1. The overall heat transfer coefficient range is 300–650 W m−2 K−1 while the compactness with respect to the heat exchanger core is approximately 1050 m2 m−3. The empirical correlations to predict the local heat transfer coefficient and pressure drop factor as a function of the Reynolds number have been proposed for the tested PCHE.  相似文献   

20.
An experimental study for air-side thermal-hydraulic performance of brazed aluminum heat exchangers under dehumidifying conditions has been performed. For 30 samples of louvered fin heat exchangers with different geometrical parameters, the heat transfer and pressure drop characteristics for wet surface were evaluated. The test was conducted for air-side Reynolds number in the range of 80–300 and tube-side water flow rate of 320 kg/h. The dry- and wet-bulb temperatures of the inlet air for heat exchangers were 27 and 19 °C, respectively and the inlet water temperature was 6 °C. The air-side thermal performance data for cooling and dehumidifying conditions were analyzed using effectiveness-NTU method for cross-flow heat exchanger with both fluids unmixed. The test results are reported, compared with those for the dry surface heat exchangers, in terms of sensible j factor and friction factor f, as functions of Reynolds number based on louver pitch. The correlations for j and f factors are developed within rms errors of ±16.9 and ±13.6%, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏