首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 889 毫秒
1.
Chemiresistor-based vapour sensors made from network films of single-walled carbon nanotube (SWNT) bundles on flexible plastic substrates (polyethylene terephthalate, PET) can be used to detect chemical warfare agent simulants for the nerve agents Sarin (diisopropyl methylphosphonate, DIMP) and Soman (dimethyl methylphosphonate, DMMP). Large, reproducible resistance changes (75-150%), are observed upon exposure to DIMP or DMMP vapours, and concentrations as low as 25?ppm can be detected. Robust sensor response to simulant vapours is observed even in the presence of large equilibrium concentrations of interferent vapours commonly found in battle-space environments, such as hexane, xylene and water (10?000?ppm each), suggesting that both DIMP and DMMP vapours are capable of selectively displacing other vapours from the walls of the SWNTs. Response to these interferent vapours can be effectively filtered out by using a 2?μm thick barrier film of the chemoselective polymer polyisobutylene (PIB) on the SWNT surface. These network films are composed of a 1-2?μm thick non-woven mesh of SWNT bundles (15-30?nm diameter), whose sensor response is qualitatively and quantitatively different from previous studies on individual SWNTs, or a network of individual SWNTs, suggesting that vapour sorption at interbundle sites could be playing an important role. This study also shows that the line patterning method used in device fabrication to obtain any desired pattern of films of SWNTs on flexible substrates can be used to rapidly screen simulants at high concentrations before developing more complicated sensor systems.  相似文献   

2.
Infrared multiple photon dissociation (IRMPD) was used to generate vibrational spectra of ions produced with a direct analysis in real time (DART) ionization source coupled to a 4.7 T Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. The location of protonation on the nerve agent simulants diisopropyl methylphosphonate (DIMP) and dimethyl methylphosphonate (DMMP) was studied while solutions of the compounds were introduced for extended periods of time with a syringe pump. Theoretical vibrational spectra were generated with density functional theory calculations. Visual comparison of experimental mid-IR IRMPD spectra and theoretical spectra could not establish definitively if a single structure or a mixture of conformations was present for the protonated parent of each compound. However, theoretical calculations, near-ir IRMPD spectra, and frequency-to-frequency and statistical comparisons indicated that the protonation site for both DIMP and DMMP was predominantly, if not exclusively, the phosphonyl oxygen instead of one of the oxygen atoms with only single bonds.  相似文献   

3.
Arrays of conducting polymer composite vapor detectors have been evaluated for performance in the presence of the nerve agent simulants dimethylmethylphosphonate (DMMP) and diisopropylmethylphosponate (DIMP). Limits of detection for DMMP on unoptimized carbon black/ organic polymer composite vapor detectors in laboratory air were estimated to be 0.047-0.24 mg m(-3). These values are lower than the EC50 value (where EC50 is the airborne concentration sufficient to induce severe effects in 50% of those exposed for 30 min) for the nerve agents sarin (methylphosphonofluoridic acid, 1-methylethyl ester) and soman (methylphosphonofluoridic acid, 1,2,2-trimethylpropyl ester), which has been established as approximately 0.8 mg m(-3). Arrays of these vapor detectors were easily able to resolve signatures due to exposures to DMMP from those due to DIMP or due to a variety of other test analytes (including water, methanol, benzene, toluene, diesel fuel, lighter fluid, vinegar, and tetrahydrofuran) in a laboratory air background. In addition, DMMP at 27 mg m(-3) could be detected and differentiated from the signatures of the other test analytes in the presence of backgrounds of potential interferences, including water, methanol, benzene, toluene, diesel fuel, lighter fluid, vinegar, and tetrahydrofuran, even when these interferents were present in much higher concentrations than that of the DMMP or DIMP being detected.  相似文献   

4.
Distributed sensing of gas-phase chemicals using highly sensitive and inexpensive sensors is of great interest for many defense and consumer applications. In this paper we present ppb-level detection of dimethyl methylphosphonate (DMMP), a common simulant for sarin gas, with a ppt-level resolution using an improved capacitive micromachined ultrasonic transducer (CMUT) as a resonant chemical sensor. The improved CMUT operates at a higher resonant frequency of 47.7 MHz and offers an improved mass sensitivity of 48.8 zg/Hz/μm(2) by a factor of 2.7 compared to the previous CMUT sensors developed. A low-noise oscillator using the CMUT resonant sensor as the frequency-selective device was developed for real-time sensing, which exhibits an Allan deviation of 1.65 Hz (3σ) in the presence of a gas flow; this translates into a mass resolution of 80.5 zg/μm(2). The CMUT resonant sensor is functionalized with a 50-nm thick DKAP polymer developed at Sandia National Laboratory for dimethyl methylphosphonate (DMMP) detection. To demonstrate ppb-level detection of the improved chemical sensor system, the sensor performance was tested at a certified lab (MIT Lincoln Laboratory), which is equipped with an experimental chemical setup that reliably and accurately delivers a wide range of low concentrations down to 10 ppb. We report a high volume sensitivity of 34.5 ± 0.79 pptv/Hz to DMMP and a good selectivity of the polymer to DMMP with respect to dodecane and 1-octanol.  相似文献   

5.
Development of environmentally acceptable decontaminants of chemical weapons and other highly toxic chemicals is important because of security, economical, health, political, and environmental reasons. The efficiency of natural zeolite (clinoptilolite) and synthetic zeolite, metal oxides, and their mixtures as chemical and physical sorbents of chemical warfare agents (CWA) was investigated. Commonly studied chemical warfare agent simulants dimethyl methylphosphonate (DMMP) and 2-chloroethyl ethyl sulfide (2-CEES) were included in this study. Organic solutions of DMMP and 2-CEES were passed through a column filled with natural and synthetic zeolites and their mixtures with metal oxides. After passing through the column filled with different sorbents, all eluents were filtered and centrifuged before the gas chromatography–mass spectroscopy (GC–MS) analysis. The efficiency of investigated adsorbents was estimated based on the obtained data. All investigated sorbents exhibited absorption efficiency for both simulants of chemical warfare agents. Infrared spectroscopy was used for the detection of DMMP and 2-CEES adsorbed to the investigated adsorbents. Since GC–MS analysis results indicate very good sorption properties of both simulants, the detection of adsorbed CWA simulants was a matter of routine.  相似文献   

6.
Gurton KP  Felton M  Dahmani R  Ligon D 《Applied optics》2007,46(25):6323-6329
We present newly measured results of an ongoing experimental program established to measure optical cross sections in the mid- and long-wave infrared for a variety of chemically and biologically based aerosols. For this study we consider only chemically derived aerosols, and in particular, a group of chemical compounds often used as simulants for the detection of extremely toxic organophosphorus nerve agents. These materials include: diethyl methylphosphonate (DEMP), dimethyl methylphosphonate (DMMP), diisopropyl methylphosphonate (DIMP), and diethyl phthalate (DEP). As reported in a prior study [Appl. Opt. 44, 4001 (2005)], we combine two optical techniques well suited for aerosol spectroscopy [i.e., flow-through photoacoustics and Fourier transform infrared (FTIR) emission spectroscopy], to measure in situ the absolute extinction and absorption cross sections over a variety of wavelengths spanning the IR spectral region from 3 to 13 mum. Aerosol size distribution(s), particle number density, and dosimetric measurements are recorded simultaneously in order to present optical cross sections that are aerosol mass normalized, i.e., m(2)/gram. Photoacoustic results, conducted at a series of CO(2) laser lines, compare well with measured broadband FTIR spectral extinction. Both FTIR and photoacoustic data also compare well with Mie theory calculations based on measured size distributions and previously published complex indices of refraction.  相似文献   

7.
For the first time, the use of a traditional ionization source for ion mobility spectrometry (radioactive nickel ((63)Ni) beta emission ionization) and three alternative ionization sources (electrospray ionization (ESI), secondary electrospray ionization (SESI), and electrical discharge (corona) ionization (CI)) were employed with an atmospheric pressure ion mobility orthogonal reflector time-of-flight mass spectrometer (IM(tof)MS) to detect chemical warfare agent (CWA) simulants from both aqueous- and gas-phase samples. For liquid-phase samples, ESI was used as the sample introduction and ionization method. For the secondary ionization (SESI, CI, and traditional (63)Ni ionization) of vapor-phase samples, two modes of sample volatilization (heated capillary and thermal desorption chamber) were investigated. Simulant reference materials, which closely mimic the characteristic chemical structures of CWA as defined and described by Schedule 1, 2, or 3 of the Chemical Warfare Convention treaty verification, were used in this study. A mixture of four G/V-type nerve simulants (dimethyl methylphosphonate, pinacolyl methylphosphonate, diethyl phosphoramidate, and 2-(butylamino)ethanethiol) and one S-type vesicant simulant (2-chloroethyl ethyl sulfide) were found in each case (sample ionization and introduction methods) to be clearly resolved using the IM(tof)MS method. In many cases, reduced mobility constants (K(o)) were determined for the first time. Ion mobility drift times, flight times, relative signal intensities, and fragmentation product signatures for each of the CWA simulants are reported for each of the methods investigated.  相似文献   

8.
A new, rapid air sampling/sample preparation methodology was investigated using adsorptive solid-phase microextraction (SPME) fiber coatings and nonequilibrium conditions for volatile organic compounds (VOCs). This method is the fastest extraction technique for air sampling at typical airborne VOC concentrations. A theoretical model for the extraction was formulated based on the diffusion through the interface between the sampled (bulk) air and the SPME coating. Parameters that affect the extraction process including sampling time, air velocity, air temperature, and relative humidity were investigated with the porous (solid) PDMS/DVB and Carboxen/PDMS coatings. Very short sampling times from 5 s to 1 min were used to minimize the effects of competitive adsorption and to calibrate the extraction process in the initial linear extraction region. The predicted amounts of extracted mass compared well with the measured amounts of target VOCs. Findings presented in this study extend the existing fundamental knowledge related to sampling/sample preparation with SPME, thereby enabling the development of new sampling devices for the rapid sampling of air, headspace, water, and soil.  相似文献   

9.
A needle trap device (NTD) and commercial poly(dimethylsiloxane) (PDMS) 7-microm film thickness solid-phase microextraction (SPME) fibers were used for the sampling and analysis of aerosols and airborne particulate matter (PM) from an inhaler-administered drug, spray insect repellant, and tailpipe diesel exhaust. The NTD consisted of a 0.53-mm o.d. stainless steel needle having 5 mm of quartz wool packing section near the needle tip. Samples were collected by drawing air across the NTD with a Luertip syringe or via direct exposure of the SPME fiber. The mass loading of PM was varied by adjusting the volume of air pulled through the NTD or by varying the sampling time for the SPME fiber. The air volumes ranged from 0.1 to 50 mL, and sampling times varied from 10 s to 16 min. Particulates were either trapped on the needle packing or sorbed onto the SPME fiber. The devices were introduced to a chromatograph/mass spectrometer (GC/MS) injector for 5 min desorption. In the case of the NTD, 10 microL of clean air was delivered by a gas-tight syringe to aid the introduction of desorbed analytes. The compounds sorbed onto particles extracted by the SPME fiber or trapped in the needle device were desorbed in the injector and no carry-over was observed. Both devices performed well in extracting airborne polycyclic aromatic hydrocarbons (PAHs) in diesel exhaust, triamcinolone acetonide in a dose of asthma drug and DEET in a dose of insect repellant spray. Results suggest that the NTDs and PDMS 7-microm fibers can be used for airborne particulate sampling and analysis, providing a simple, fast, reusable, and cost-effective screening tool. The advantage of the SPME fiber is the open-bed geometry allowing spectroscopic investigations of particulates; for example, with Raman microspectroscopy.  相似文献   

10.
Initial results demonstrating the ability to classify surface-enhanced Raman (SERS) spectra of chemical and biological warfare agent simulants are presented. The spectra of two endospores (B. subtilis and B. atrophaeus), two chemical agent simulants (dimethyl methylphosphonate (DMMP) and diethyl methylphosphonate (DEMP)), and two toxin simulants (ovalbumin and horseradish peroxidase) were studied on multiple substrates fabricated from colloidal gold adsorbed onto a silanized quartz surface. The use of principal component analysis (PCA) and hierarchical clustering were used to evaluate the efficacy of identifying potential threat agents from their spectra collected on a single substrate. The use of partial least squares-discriminate analysis (PLS-DA) and soft independent modeling of class analogies (SIMCA) on a compilation of data from separate substrates, fabricated under identical conditions, demonstrates both the feasibility and the limitations of this technique for the identification of known but previously unclassified spectra.  相似文献   

11.
12.
Previous aerosol studies utilizing solid-phase microextraction (SPME) predominantly focused on volatile and semivolatile compounds in the gaseous phase. Difficulties were associated with quantitative analysis of these compounds when they were associated with atmospheric particles. The present study combines SPME technology with that of carboxen packed needles (needle trap, NT) for analysis of gaseous and particle-bound compounds in atmospheric samples. The NT device is constructed as a micro trap by placing some small sorbents in a needle. Aerosol samples are collected by drawing air through the NT device with a pump. The trapped components contain both gaseous chemical compounds as well as particulate matter present in the sample. The total concentration of analytes in an aerosol sample can be obtained on the basis of the exhaustive sampling mode of the NT device. Direct SPME is simultaneously used to determine gaseous compound in the aerosol sample. As a result, the SPME and NT devices, when used together, can provide a complete solution to highly efficient and accurate aerosol studies. The theoretical considerations of SPME and NT devices for aerosol sampling are validated by sampling seasalt aerosol, barbecue, and cigarette smoke. The concentrations of PAHs in the different phases of the samples are few ng/L. Result analysis shows that SPME and the NT device demonstrate several important advantages such as simplicity, convenience, and low costs under laboratory and on-site field sampling conditions.  相似文献   

13.
Rapid sampling and sample preparation methodology was investigated using adsorptive poly(dimethylsiloxane)/divinylbenzene and Carboxen/poly(dimethylsiloxane) solid-phase microextraction (SPME) fiber coatings and volatile aromatic hydrocarbons (BTEX: benzene, toluene, ethylbenzene, and o-xylene). A flow-through system was used to generate a standard aqueous solution of BTEX as model sample with known linear velocity. Parameters that affect the extraction process, including sampling time, concentration, water velocity, and temperature, were investigated. Very short sampling times from 10 s and sorbents with strong affinity and large capacity were used to ensure the effect of '"zero sink" and to calibrate the extraction process in the initial linear extraction region. Several different concentrations were investigated, and it was found that mass uptake changes with concentration linearly. The increase of water velocity increases mass uptake, though the increase is not linear. Temperature does not affect mass uptake significantly under typical field sampling conditions. To further accurately describe rapid SPME analysis of aqueous samples, a new model translated from heat transfer to a circular cylinder in cross-flow was used. An empirical correlation to this model was used to predict the mass-transfer coefficient. Findings indicate that predicted mass uptake compares well with experimental mass uptake. The new model was tested for rapid air sampling, and it was found that this new model also predicted rapid air sampling accurately. Findings presented in this study extend the existing fundamental knowledge related to rapid sampling/sample preparation with SPME.  相似文献   

14.
The potential of solid-phase microextraction (SPME) for time-weighted average (TWA) sampling of volatile sulfur compounds in air at ppb concentrations was investigated. The target compounds (hydrogen sulfide, methanethiol (MeSH), ethanethiol (EtSH), dimethyl sulfide (Me2S), and dimethyl disulfide (Me2S2)) were extracted using SPME with a Carboxen-poly(dimethylsiloxane) fiber coating, and diffusion was controlled by keeping the fiber retracted within the needle of the sampling device. The effects of several important experimental variables (air velocity, direction of air flow, analyte concentration, humidity, temperature, extraction time) were studied. The uptake by the fiber was not affected by the direction of the air flow or the air velocity. The effects of concentration, humidity, temperature, and extraction time were examined in experiments with a central composite face design. The results showed that all or most of the investigated parameters had a significant impact on the uptake rates of H2S, MeSH, EtSH, and Me2S, which invalidated time-weighted average sampling of these compounds by SPME under the tested conditions. Moreover, reverse diffusion of H2S, MeSH, and EtSH occurred at 40% relative humidity. For Me2S2, the uptake rate had a variation of only 8% within the whole experimental domain, and the experimental value derived for the uptake rate was consistent with the theoretical value. This result was confirmed by comparative analyses of industrial samples by the standard addition method. Therefore, SPME appears to be a suitable technique for TWA sampling of Me2S2 using the Carboxen-poly(dimethylsiloxane) fiber coating. Finally, in an investigation of potential losses during storage of the fiber, no significant losses of the target compounds were detected after 3 days at -80 degrees C.  相似文献   

15.
Commercial poly(dimethylsiloxane) (PDMS) 7-microm solid-phase microextraction (SPME) fibers were used for sampling and Raman spectroscopic analysis of a tailpipe diesel exhaust, candle smoke, cigarette smoke, and asbestos dust. Samples were collected via direct exposure of the SPME fiber to contaminated air. The mass loading for SPME fibers was varied by changing the sampling time. Results indicate that PDMS-coated fibers provide a simple, fast, reusable, and cost-effective air sampling tool for airborne particulates. The PDMS coating was stable; Raman bands of the PDMS coating were observed exactly at the same wavenumber positions before and after air sampling. Raman spectroscopic analysis resulted in identification of several characteristic bands allowing chemical speciation of particulates. The advantage of the SPME fiber is the open bed geometry allowing for application of various spectroscopic methods of particulate analysis. This paper describes the first-ever combined application of SPME technology with Raman confocal microspectroscopy for sampling and analysis of airborne particulates. Advantages of the combination of solid-phase microextraction and Raman microspectroscopy for airborne particulate analysis are discussed. Challenges associated with combined SPME sampling and Raman analysis of single particles are also described.  相似文献   

16.
For the first time, a traditional radioactive nickel (63Ni) beta emission ionization source for ion mobility spectrometry was employed with an atmospheric pressure ion mobility orthogonal reflector time-of-flight mass spectrometer (IM(tof)MS) to detect a chemical warfare agent (CWA) simulant from aerosol samples. Aerosol-phase sampling employed a quartz cyclonic chamber for sample introduction. The simulant reference material, which closely mimicked the characteristic chemical structure of CWAs as defined and described by Schedule 1, 2, or 3 of the Chemical Warfare Convention treaty verification, was used in this study. An overall elevation in arbitrary signal intensity of approximately 1.0 orders of magnitude was obtained by the progressive increase of the thermal AP-IMS temperature from 75 to 275 degrees C. A mixture of one G-type nerve simulant (dimethyl methylphosphonate (DMMP)) in four (water, kerosene, gasoline, diesel) matrixes was found in each case (AP-IMS temperature 75-275 degrees C) to be clearly resolved in less than 2.20 x 10(4) micros using the IM(tof)MS instrument. Corresponding ions, masses, drift times, K(o) values, and arbitrary signal intensities for each of the sample matrixes are reported for the CWA simulant DMMP.  相似文献   

17.
Metal-organic frameworks (MOFs) have high surface areas and tailorable molecular properties so they have the potential of being selective adsorbents for preconcentrators. In this paper, IRMOF1 is tested as an adsorbent for preconcentration for the first time using dimethyl methylphosphonate (DMMP) as a test case. We find that DMMP is selectively adsorbed on IRMOF1 and is released upon heating to 250 degrees C. Concentration gains of more than 5000 are observed for DMMP with a 4-s sampling time. Sorption capacities are 0.95 g of DMMP/g of IRMOF1. By comparison, dodecane shows a preconcentration gain of approximately 5 under similar conditions. These results demonstrate that MOFs can be quite useful in selective preconcentrators.  相似文献   

18.
To address the challenge of measuring real-time analyte concentrations within dynamic systems, the temporal resolution of the solid-phase microextraction (SPME) approach has been investigated. A mass-uptake model for SPME within a dynamic system was developed and validated, with experimental factors affecting the temporal resolution (sampling time, agitation, SPME fiber dimensions, sample concentration and change rate, and instrument sensitivity) characterized. Calibration methods for time-resolved sampling in a dynamic system were compared. To demonstrate the efficacy of time-resolved SPME, this approach was successfully applied to investigate the binding kinetics between plasma proteins and pharmaceuticals, which verified a decrease in free pharmaceutical concentrations over time in the presence of bovine serum albumin. The current study provides the theoretical and logistical framework for applying SPME to the real-time measurement of dynamic systems, facilitating future SPME applications such as in vivo metabolomic studies.  相似文献   

19.
Ultraviolet (UV) Raman spectroscopy is being applied to the detection of chemical agent contamination of natural and man-made surfaces. In support of these efforts, we have measured the UV Raman signatures of the G-series nerve agents GA (tabun), GB (sarin), GD (soman), GF (cyclosarin), and the agent simulant diisopropyl methylphosphonate (DIMP) at 248 nm and 262 nm, as well as taking their UV Raman and UV absorption cross-sections. Of these chemicals, only GA exhibits any significant pre-resonance enhancement. We also show that reduction of the excitation wavelength from 262 nm to 248 nm effectively shifts the Raman spectrum away from a substantial sample fluorescence background, implying a significant improvement in detection capability.  相似文献   

20.
Single-walled carbon nanotube (SWNT) films were prepared on interdigitated electrodes by airbrush technique, and their sensing properties to dimethyl methylphosphonate (DMMP) were studied. The SWNT films were characterized by field-emission scanning electron microscope. The response to different concentrations of DMMP vapors were investigated at room temperature. The results showed that the capacitance of airbrush SWNT sensor decreased rapidly in varying concentrations ranging from 12 to 60 mg/m3 (2.4–12 ppm). The capacitance sensitivity was about 12.5 % when exposed to 12 mg/m3 DMMP vapor. The capacitance sensitivity was higher when the initial capacitance and loss tangent were higher and the SWNT film was denser. It was found that the capacitance sensitivity was nearly 10 times to the resistance sensitivity. The airbrush SWNT sensor exhibited highly and fast capacitance response, good repeatability and selectivity for DMMP vapor.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号