首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Hybridized engines have become the focus of research nowadays in order to update the existing engines in different transportation sectors. This paper presents a hybridized aircraft engine consisting of a molten carbonate fuel cell system and a commercial turbofan system. The MCFC units are connected to a steam reforming and a water gas shift system. Also, five clean fuels are selected, such as dimethyl ether, hydrogen, ethanol, methane, and methanol, which are combined with different mass ratios to form five different fuel blends. The hybridized aircraft is investigated using three approaches: exergy analysis, exergoeconomic analysis, and exergoenvironmental analysis. It is found that the proposed engine has an average exergetic efficiency of 88% and an average exergy destruction ratio of 12%. The specific exergetic cost of electricity of the engine has an average value of 710 $/GJ for the high-pressure turbine and 230$/GJ for the intermediate and low-pressure turbines, as well as 50 $/GJ for the MCFC. The average specific exergoenvironmental impact of electricity is 14 mPt/MJ for turbines and 4 mPt/MJ for the MCFC. In addition, a blend of ethanol and hydrogen appears to be a viable option economically and environmentally.  相似文献   

2.
LNG technology has been in use since the 1960s. During the last 20 years the total cost of LNG technology has decreased by 30% due mainly to improvements of the liquefaction process and shipping. However, the regasification system has not been significantly improved. The paper presents a detailed advanced exergetic analysis of a novel co-generation concept that combines LNG regasification with the generation of electricity. The analysis includes splitting the exergy destruction within each component into its unavoidable, avoidable, endogenous and exogenous parts as well as a detailed splitting of the avoidable exogenous exergy destruction. The results of the advanced exergetic analysis are confirmed through a sensitivity analysis. Finally, some suggestions for improving the overall system efficiency are developed.  相似文献   

3.
Hydrogen liquefaction systems have been the subject of intense investigations for many years. Some established gas liquefaction systems, such as the precooled Linde–Hampson systems, are not used for hydrogen liquefaction in part because of their relatively low efficiencies. Recently, more promising systems employing the modified Collins cycle have been introduced. This paper reports on second law analyses of a hydrogen liquefier operating on the modified Collins cycle. Two different modifications employing the cycle in question were attempted: (1) a helium‐refrigerated hydrogen liquefaction system and (2) a hydrogen‐refrigerated hydrogen liquefaction system. Analyses were carried out in order to identify potential areas of development and efficiency improvement. A computer code capable of computing system and component efficiencies; exergy losses; and optimum number and operating conditions of compressors, expanders, aftercoolers, intercoolers, and Joule–Thomson valves was developed. Evaluation of the thermodynamic and transport properties of hydrogen at different temperature levels was achieved by employing a hydrogen property code developed by researchers at the National Bureau of Standards (currently NIST). A parametric analysis was carried out and optimal decision rules pertaining to system component selection and design were reached. Economic analyses were also reported for both systems and indicated that the helium‐refrigerated hydrogen liquefier is more economically feasible than the hydrogen‐refrigerated hydrogen liquefier. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

4.
In this paper, the thermodynamic study of a combined geothermal power-based hydrogen generation and liquefaction system is investigated for performance assessment. Because hydrogen is the energy of future, the purpose of this study is to produce hydrogen in a clear way. The results of study can be helpful for decision makers in terms of the integrated system efficiency. The presented integrated hydrogen production and liquefaction system consists of a combined geothermal power system, a PEM electrolyzer, and a hydrogen liquefaction and storage system. The exergy destruction rates, exergy destruction ratios and exergetic performance values of presented integrated system and its subsystems are determined by using the balance equations for mass, energy, entropy, energy and exergy and evaluated their performances by means of energetic and exergetic efficiencies. In this regard, the impact of some design parameters and operating conditions on the hydrogen production and liquefaction and its exergy destruction rates and exergetic performances are investigated parametrically. According to these parametric analysis results, the most influential parameter affecting system exergy efficiency is found to be geothermal source temperature in such a way that as geothermal fluid temperature increases from 130 °C to 200 °C which results in an increase of exergy efficiency from 38% to 64%. Results also show that, PEM electrolyzer temperature is more effective than reference temperature. As PEM electrolyzer temperature increases from 60 °C to 85 °C, the hydrogen production efficiency increases from nearly 39% to 44%.  相似文献   

5.
A. Boyano  G. Tsatsaronis 《Energy》2011,36(4):2202-2214
Steam methane reforming (SMR) is one of the most promising processes for hydrogen production. Several studies have demonstrated its advantages from the economic viewpoint. Nowadays process development is based on technical and economical aspects; however, in the near future, the environmental impact will play a significant role in the design of such processes. In this paper, an SMR process is studied from the viewpoint of overall environmental impact, using an exergoenvironmental analysis. This analysis presents the combination of exergy analysis and life cycle assessment. Components where chemical reactions occur are the most important plant components from the exergoenvironmental point of view, because, in general, there is a high environmental impact associated with these components. This is mainly caused by the exergy destruction within the components, and this in turn is mainly due to the chemical reactions. The obtained results show that the largest potential for reducing the overall environmental impact is associated with the combustion reactor, the steam reformer, the hydrogen separation unit and the major heat exchangers. The environmental impact in these components can mainly be reduced by improving their exergetic efficiency. A sensitivity analysis for some important exergoenvironmental variables is also presented in the paper.  相似文献   

6.
Renewable energy-based hydrogen production plants can offer potential solutions to both ensuring sustainability in energy generation systems and designing environmentally friendly systems. In this combined work, a novel solar energy supported plant is proposed that can generate hydrogen, electricity, heating, cooling and hot water. With the suggested integrated plant, the potential of solar energy usage is increased for energy generation systems. The modeled integrated system generally consists of the solar power cycle, solid oxide fuel cell plant, gas turbine process, supercritical power plant, organic Rankine cycle, cooling cycle, hydrogen production and liquefaction plant, and hot water production sub-system. To conduct a comprehensive thermodynamic performance analysis of the suggested plant, the combined plant is modeled according to thermodynamic equilibrium equations. A performance assessment is also conducted to evaluate the impact of several plant indicators on performance characteristics of integrated system and its sub-parts. Hydrogen production rate in the suggested plant according to the performance analysis performed is realized as 0.0642 kg/s. While maximum exergy destruction rate is seen in the solar power plant with 8279 kW, the cooling plant has the lowest exergy destruction rate as 1098 kW. Also, the highest power generation is obtained from gas turbine cycle with 7053 kW. In addition, energetic and exergetic efficiencies of solar power based combined cycle are found as 56.48% and 54.06%, respectively.  相似文献   

7.
T. Morosuk  G. Tsatsaronis 《Energy》2011,36(6):3771-3778
During the last two decades the total cost of LNG technology has decreased significantly due to improvements of the liquefaction process. However, the regasification system has not been considerably improved. It is known that for the regasification process about 1.5% of LNG is used. Two novel, gas-turbine-based concepts for combining LNG regasification with the generation of electricity are discussed in this paper. These concepts have relatively low investment costs and high efficiencies. An advanced exergetic analysis is applied to one of these attractive LNG-based cogeneration systems to identify the potential for improvement and the interactions among components. In an advanced exergetic analysis, the exergy destruction within each component is split into unavoidable/avoidable and endogenous/exogenous parts. The advantages of this analysis over a conventional one are demonstrated. Some new developments in the advanced exergetic analysis and options for improving the concepts are also presented.  相似文献   

8.
This paper provides an exergy analysis of the multistage cascade refrigeration cycle used for natural gas liquefaction. The equations of exergy destruction and exergetic efficiency for the main cycle components such as evaporators, condensers, compressors, and expansion valves are developed. The relations for the total exergy destruction in the cycle and the cycle exergetic efficiency are obtained. Also, an expression for the minimum work requirement for the liquefaction of natural gas is developed. It is shown that the minimum work depends only on the properties of the incoming and outgoing natural gas, and it increases with decreasing liquefaction temperature. The minimum work for a typical natural gas inlet and exit state is determined to be 456.8 kJ kg?1 of liquefied natural gas (LNG), which corresponds to a coefficient of performance (COP) of 1.8. Using a typical actual work input value; the exergetic efficiency of the multistage cascade refrigeration cycle is determined to be 38.5% indicating a great potential for improvements. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

9.
In this paper, a fuel cell power generation system fed by hydrogen is analyzed by different performance criteria over the entire range of potential operating conditions. First law efficiency and net power output are considered for conventional energetic indices of performance, and exergy destruction rate is taken into consideration as an exergetic performance criteria. A new exergetic criterion called the exergetic performance coefficient (EPC) is introduced and is applied to the system model based on zero-dimensional approach. The system model consists of the following components: fuel cell stack, afterburner, fuel and air compressors, and heat exchangers. The effects of the operating conditions on the system performance are studied parametrically. The obtained results based on the exergetic performance coefficient criterion are compared with first law efficiency, power output and exergy destruction rate. Results show that design insights of fuel cell systems can be considerably improved when conventional energetic analyses are supplemented with EPC criterion.  相似文献   

10.
C. Coskun  I. Dincer 《Energy》2011,36(11):6358-6366
In this study, a modified exergoeconomic model is proposed for geothermal power plants using exergy and cost accounting analyses, and a case study is in this regard presented for the Tuzla geothermal power plant system (Tuzla GPPS) in Turkey to illustrate an application of the currently modified exergoeconomic model. Tuzla GPPS has a total installed capacity of 7.5 MW and was recently put into operation. Electricity is generated using a binary cycle. In the analysis, the actual system data are used to assess the power plant system performance through both energy and exergy efficiencies, exergy losses and loss cost rates. Exergy efficiency values vary between 35% and 49% with an average exergy efficiency of 45.2%. The relations between the capital costs and the exergetic loss/destruction for the system components are studied. Six new exergetic cost parameters, e.g., the component annualized cost rate, exergy balance cost, overall unavoidable system exergy destruction/loss cost rate, overall unavoidable system exergy destruction/loss cost rate, overall unavoidable system exergy production cost rate and the overall unavoidable system exergy production cost rate are studied to provide a more comprehensive evaluation of the system.  相似文献   

11.
In the present work, conventional and enhanced exergy analyses were applied to the cryogenic liquefaction process of hydrogen gas. The hydrogen liquefaction unit consists of a multi-stage compressor, booster compressor-turbine pair, and heat exchanger block. Convectional exergy analysis cannot identify parts of exergy inefficiencies. In addition, by convectional exergy analysis, it cannot determine inevitable exergy losses that occur due to technological limits. For this reason, enhanced exergy analysis should be applied to the system. The exergy destruction affecting the exergy efficiency of the hydrogen liquefaction unit was investigated in detail. This study suggests an enhanced exergy analysis of a cryogenic liquefaction system. According to the results of the convectional exergy analysis, exergy efficiency of the whole liquefaction process are 32.22%. Also, the highest and lowest endogenous exergy destruction among whole components is calculated as 9563 kW and 92.83 kW in the turbine and CM-1, respectively. With these calculated results, the potential for improvement in the turbine in the liquefaction system was found to be high.  相似文献   

12.
In this paper, a conceptual hybrid biomass gasification system is developed to produce hydrogen and is exergoeconomically analyzed. The system is based on steam biomass gasification with the lumped solid oxide fuel cell (SOFC) and solid oxide electrolyser cell (SOEC) subsystem as the core components. The gasifier gasifies sawdust in a steam medium and operates at a temperature range of 1023-1423 K and near atmospheric pressure. The analysis is conducted for a specific steam biomass ratio of 0.8 kmol-steam/kmol-biomass. The gasification process is assumed to be self-thermally standing. The pressurized SOFC and SOEC are of planar types and operate at 1000 K and 1.2 bar. The system can produce multi-outputs, such as hydrogen (with a production capacity range of 21.8-25.2 kgh−1), power and heat. The internal hydrogen consumption in the lumped SOFC-SOEC subsystem increases from 8.1 to 8.6 kg/h. The SOFC performs an efficiency of 50.3% and utilizes the hydrogen produced from the steam that decomposes in the SOEC. The exergoeconomic analysis is performed to investigate and describe the exergetic and economic interactions between the system components through calculations of the unit exergy cost of the process streams. It obtains a set of cost balance equations belonging to an exergy flow with material streams to and from the components which constitute the system. Solving the developed cost balance equations provides the cost values of the exergy streams. For the gasification temperature range and the electricity cost of 0.1046 $/kWh considered, the unit exergy cost of hydrogen ranges from 0.258 to 0.211 $/kWh.  相似文献   

13.
In the proposed study, the thermodynamic performance assessment of ocean thermal energy conversion (OTEC) based hydrogen generation and liquefaction system are evaluated. In this context, the energetic and exergetic analyses of integrated system are conducted for multigeneration. This integrated process is consisted of the heat exchangers, turbine, condenser, pumps, solar collector system, hot storage tank, cold storage tank and proton exchange membrane (PEM) electrolyzer. In addition to that, the impacts of different design indicators and reference ambient parameters on the exergetic performance and exergy destruction rate of OTEC based hydrogen production system are analyzed. The energetic and exergetic efficiencies of integrated system are founded as 43.49% and 36.49%, respectively.  相似文献   

14.
A hybrid renewable-based integrated energy system for power-to-X conversion is designed and analyzed. The system produces several valuable commodities: Hydrogen, electricity, heat, ammonia, urea, and synthetic natural gas (SNG). Hydrogen is produced and stored for power generation from solar energy by utilizing solid oxide electrolyzers and fuel cells. Ammonia, urea, and synthetic natural gas are produced to mitigate hydrogen transportation and storage complexities and act as energy carriers or valuable chemical products. The system is analyzed from a thermodynamic perspective, the exergy destruction rates are compared, and the effects of different parameters are evaluated. The overall system's energy efficiency is 56%, while the exergy efficiency is 14%. The highest exergy destruction occurs in the Rankine cycle with 48 MW. The mass flow rates of the produced chemicals are 0.064, 0.088, and 0.048 kg/s for ammonia, urea, and SNG, respectively.  相似文献   

15.
In this study, a novel multi-generation system is proposed by integrating a solid oxide fuel cell (SOFC)-gas turbine (GT) with multi-effect desalination (MED), organic flash cycle (OFC) and polymer electrolyte membrane electrolyzer (PEME) for simultaneous production of electricity, fresh water and hydrogen. A comprehensive exergoeconomic analysis and optimization are conducted to find the best design parameters considering exergy efficiency and total unit cost of products as objective functions. The results show that the exergy efficiency and the total unit cost of products in the optimal condition are 59.4% and 23.6 $/GJ, respectively, which offers an increase of 2% compared to exergy efficiency of SOFC-GT system. Moreover, the system is capable of producing 2.5 MW of electricity by the SOFC-GT system, 5.6 m3/h of fresh water by MED unit, and 1.8 kg/h of hydrogen by the PEME. The associated cost for producing electricity, fresh water and hydrogen are 3.4 cent/kWh, 37.8 cent/m3, and 1.7 $/kg, respectively. A comparison between the results of the proposed system and those reported in other related papers are presented. The diagram of the exergy flow is also plotted for the exact determination of the exergy flow rate in each component, and also, location and value of exergy destruction. Finally, the capability of the proposed system for a case study of Iran is examined.  相似文献   

16.
The present paper deals with the hydrogen liquefaction with absorption precooling cycle assisted by geothermal water is modeled and analyzed. Uses geothermal heat in an absorption refrigeration process to precool the hydrogen gas is liquefied in a liquefaction cycle. High-temperature geothermal water using the absorption refrigeration cycle is used to decrease electricity work consumption in the gas liquefaction cycle. The thermoeconomic optimization procedure is applied using the genetic algorithm method to the hydrogen liquefaction system. The objective is to minimize the unit cost of hydrogen liquefaction of the composed system. Based on optimization calculations, hydrogen gas can be cooled down to ?30 °C in the precooling cycle. This allows the exergetic cost of hydrogen gas to be reduced to be 20.16 $/GJ (2.42 $/kg LH2). The optimized exergetic cost of liquefied hydrogen is 4.905 $/GJ (1.349 $/kg LH2), respectively.  相似文献   

17.
In the present work, an advanced hydrogen liquefaction system with catalyst infused heat exchangers is proposed, analyzed and assessed energetically and exergetically. The analysis starts with exergetic considerations on hydrogen liquefaction using different alternatives of pre-cooling including the conversion from normal to parahydrogen. It further explains the fundamentals of a proposed liquefaction process. The goal is then to assess the proposed system, make modifications and improve the system. The present system covers all of these portions of a hydrogen liquefaction system with an ultimate goal of achieving a sustainable and environmentally harmless system. The proposed hydrogen liquefaction system is simulated in the Aspen Plus and the performance of the system is measured through energy and exergy efficiencies. The resulting energy efficiency of the system is calculated to be 15.4%, and the exergy efficiency of the system is found to be 11.5%.  相似文献   

18.
In a hydrogen liquefier the pre-compression of feed gas has generally higher stand-alone exergy efficiency than the cooling and liquefaction sub-process. Direct comparison of liquefiers based on overall exergy efficiency and specific power consumption will favour those with a higher portion of pre-compression. A methodology for comparing hydrogen liquefaction processes that compensates for non-uniformity in feed specifications has been developed and applied to three different hydrogen liquefiers. The processes in consideration have been modified to have equal hydrogen feed pressure, resulting in a more consistent comparison. Decreased feed pressure results in generally higher power consumption but also higher exergy efficiency, and vice versa. This approach can be adapted to the boundary conditions that the liquefaction process will be subject to in a real energy system.  相似文献   

19.
In this article, a thermodynamic investigation of solar power tower assisted multigeneration system with hydrogen production and liquefaction is presented for more environmentally-benign multigenerational outputs. The proposed multigeneration system is consisted of mainly eight sub-systems, such as a solar power tower, a high temperature solid oxide steam electrolyzer, a steam Rankine cycle with two turbines, a hydrogen generation and liquefaction cycle, a quadruple effect absorption cooling process, a drying process, a membrane distillation unit and a domestic hot water tank to supply hydrogen, electrical power, heating, cooling, dry products, fresh and hot water generation for a community. The energetic and exergetic efficiencies for the performance of the present multigeneration system are found as 65.17% and 62.35%, respectively. Also, numerous operating conditions and parameters of the systems and their effects on the respective energy and exergy efficiencies are investigated, evaluated and discussed in this study. A parametric study is carried out to analyze the impact of various system design indicators on the sub-systems, exergy destruction rates and exergetic efficiencies and COPs. In addition, the impacts of varying the ambient temperature and solar radiation intensity on the irreversibility and exergetic performance for the present multigeneration system and its components are investigated and evaluated comparatively. According to the modeling results, the solar irradiation intensity is found to be the most influential parameter among other conditions and factors on system performance.  相似文献   

20.
The present study deals with a comprehensive thermodynamic modeling of a combined heat and power (CHP) system in a paper mill, which provides 50 MW of electric power and 100 ton h?1 saturated steam at 13 bars. This CHP plant is composed of air compressor, combustion chamber (CC), Air Preheater, Gas Turbine (GT) and a Heat Recovery Heat Exchanger. The design parameters of this cycle are compressor pressure ratio (rAC), compressor isentropic efficiency (ηAC), GT isentropic efficiency (ηGT), CC inlet temperature (T3), and turbine inlet temperature (T4). In the multi‐objective optimization three objective functions, including CHP exergy efficiency, total cost rate of the system products, and CO2 emission of the whole plant, are considered. The exergoenvironmental objective function is minimized whereas power plant exergy efficiency is maximized using a Genetic algorithm. To have a good insight into this study, a sensitivity analysis of the results to the interest rate as well as fuel cost is performed. The results show that at the lower exergetic efficiency, in which the weight of exergoenvironmental objective is higher, the sensitivity of the optimal solutions to the fuel cost is much higher than the location of the Pareto Frontier with the lower weight of exergoenvironmental objective. In addition, with increasing exergy efficiency, the purchase cost of equipment in the plant is increased as the cost rate of the plant increases. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   