1.
PurposeTo examine the influence of short-term miniscleral contact lens wear on corneal shape, thickness and anterior surface aberrations.MethodsScheimpflug imaging was captured before, immediately following and 3 h after a short period (3 h) of miniscleral contact lens wear for 10 young (mean 27 ± 5 years), healthy participants. Natural diurnal variations were considered by measuring baseline diurnal changes obtained on a separate control day without contact lens wear.ResultsSmall but significant anterior corneal flattening was observed immediately following lens removal (overall mean 0.02 ± 0.03 mm, p < 0.001) which returned to baseline levels 3 h after lens removal. During the 3 h recovery period significant corneal thinning (−13.4 ± 10.5 μm) and posterior surface flattening (0.03 ± 0.02 mm) were also observed (both p < 0.01). The magnitude of posterior corneal flattening during recovery correlated with the amount of corneal thinning (r = 0.69, p = 0.03). Central corneal clearance (maximum tear reservoir depth) was not associated with corneal swelling following lens removal (r = −0.24, p > 0.05). An increase in lower-order corneal astigmatism Z(2,2) was also observed following lens wear (mean −0.144 ± 0.075 μm, p = 0.02).ConclusionsFlattening of the anterior corneal surface was observed immediately following lens wear, while ‘rebound’ thinning and flattening of the posterior surface was evident following the recovery period. Modern miniscleral contact lenses that vault the cornea may slightly influence corneal shape and power but do not induce clinically significant corneal oedema during short-term wear.  相似文献   

2.
PurposeWe compare the agreement and the reliability in measuring central corneal thickness (CCT) using two different technologies.MethodThe right eyes of 35 healthy individuals who had a negative history of ophthalmic disease, or ocular surgery were examined. The CCT was determined sequentially with a rotating Scheimpflug camera (Sirius; CSO), and an ultrasound pachymeter (P-1; Takagi). For statistical analysis, we used the methods suggested by Bland and Altman.ResultsThe mean values of CCT obtained from Sirius, and ultrasound were 537 ± 28 μm, and 550 ± 35 μm, respectively. There was a high correlation between Sirius and ultrasound (r = 0.92; p < 0.001), but the difference between the two measurements was statistically significant (t = −5.7; p < 0.00001). The precision of Sirius and ultrasound were 9.4 and 15.9 μm; repeatability 13.3 and 22.4 μm, and coefficient of variation 0.9% and 1.5%, respectively. The intraclass correlation coefficient was 0.97 for Sirius and 0.95 for ultrasound.ConclusionsThe average difference between corneal thickness measured with Sirius and ultrasound pachymetry was small but clinically significant. This means that the two instruments cannot be used interchangeably. Sirius showed precision and repeatability almost twice as much as ultrasound pachymetry. Confidence interval of 13.3 μm for Sirius can show variations in corneal thickness with an uncertainty value lower than 2.5% in 95% of cases. The simplicity of use, the possibility to obtain pachymetric maps, and less invasiveness make this instrument potentially useful in contact lens practice.  相似文献   

3.
PurposeTo investigate the rate of progression of keratoconus in patients wearing pancorneal toric edge rigid gas-permeable contact lenses (pancorneal RGP-CL) compared to non-pancorneal RGP-CL. We also evaluated alterations in anterior chamber parameters with the progression of keratoconus and investigated the location of the cone in eyes with keratoconus.MethodsThe current study was a retrospective study including patients with clinically evident keratoconus from the outpatient clinic from the Department of Ophthalmology of the Erasmus Medical Center, Rotterdam, the Netherlands. Medical history and contact lens characteristics were documented. All participants underwent ophthalmic examination including corneal topography. Corneal topography was repeated at one of the consecutive visits of the patient. Patients were divided into two groups: those wearing pancorneal RGP-CL and those wearing other contact lens types. As a measure of progression of keratoconus differences in corneal topography parameters between both groups were compared.ResultsA total of 82 patients were included of which 42 had follow-up (mean 17.8 months) data. We found a significant difference in progression between eyes fitted with and without pancorneal RGP-CL (K-flat: p = 0.09, K-steep: p = 0.02, K-mean: p = 0.02, and K-minimum: p = 0.04). Compared with eyes fitted without pancorneal RGP-CL no significant difference in K-values was found for eyes fitted with pancorneal RGP-CL during follow-up. Furthermore, a significant decrease in anterior chamber volume (p < 0.001) and corneal volume (p = 0.008) was found during follow-up. In 86.6% the location of the cone was located infero-temporal.ConclusionsPancorneal RGP-CL have a better effect on stabilizing progression of keratoconus than non-pancorneal RGP-CL. The finding of an infero-temporal location of the cone in keratoconic corneas may improve results of contact lens fitting and surgical management.  相似文献   

4.
PurposeTo investigate the efficacy of spherical aberration (SA) correction with aspheric contact lenses (aspheric lenses) based on lens power, and compare the results with those of spherical contact lenses (spherical lenses).MethodsOcular higher-order aberrations were measured with a wavefront sensor, in 11 myopic subjects wearing an aspheric lens (Medalist Fresh fit (PUREVISION 2 HD); Bausch + Lomb) or a spherical lens (ACUVUE Oasys; Johnson & Johnson). Six different lens powers (−7.00 diopters (D), −5.00 D, −3.00 D, −1.00 D, +1.00 D, +3.00 D) were used for all subjects. The amount of SA correction from the contact lens at each power was calculated as the difference between SA with the contact lens on-eye and SA of the eye alone.ResultsFor the spherical lenses, SA correction was close to 0.00 μm for the +1.00 D lens, became more positive as the labeled lens power increased and became more negative as the labeled lens power decreased. For the aspheric lenses, SA correction was consistent, from −0.15 to −0.05 μm, for all lens powers except for the −1.00 D lens. SA correction for the spherical and aspheric lenses was significantly different at −7.00 D (p = 0.040), −3.00 D (p = 0.015), −1.00 D (p < 0.001), +1.00 D (p = 0.006), and +3.00 D (p < 0.001) powers.ConclusionAn aspheric lens is capable of correcting SA at different lens powers, and has SA correction in the range of −0.15 to −0.05 μm over a 6 mm aperture.  相似文献   

5.
IntroductionAccurate corneal measurements are crucial in corneal refractive surgery (CRS) to ensure successful outcomes. Soft contact lens (SCL) wear may result in changes to corneal curvature and structure. United States Food and Drug Administration (FDA) pre-operative guidelines recommend that prior to CRS, SCL wearers cease SCL wear for “at least two weeks before examination and treatment” [1]. Corneal curvature changes induced by SCL wear may take longer than two weeks to resolve.PurposeTo examine the effect of SCL wear on corneal curvature before and following two weeks SCL wear cessation. To explore the possible impact of different SCL materials and years of SCL wear.MethodsRetrospective data analysis, between a group of SCL wearers (SCL: n = 45); and a non-contact lens control group (NCL: n = 45). Corneal curvature parameters were measured using the Pentacam (Oculus, Germany), before and following two weeks cessation of SCL wear.ResultsNo significant differences in keratometry or Sagittal radius of curvature between SCL and NCL groups prior to or following SCL cessation. Tangential radius of curvature showed significant inferior steepening for the SCL group prior to SCL cessation (SCL vs. NCL; 7.77 ± 0.30 mm vs. 7.90 ± 0.30 mm; p = 0.04). Following two weeks cessation of SCL wear this appeared to have resolved.ConclusionsTwo weeks cessation of SCL wear appears sufficient for resolution of corneal curvature changes with modern SCL materials and years of SCL wear. However, further studies with longer lens deprivation periods are required to ensure stability for all SCL wearing patients.  相似文献   

6.
PurposeTo assess long-term intraocular straylight changes induced by corneal refractive therapy (CRT) and to determine whether these changes persist after cessation of CRT lens wear.MethodsA single-center, prospective, longitudinal study was performed in 22 subjects (group 1) undergoing overnight corneal refractive therapy for 1 year. Ten right eyes of 10 subjects (group 2) with emmetropia served as controls. In each subject, high contrast visual acuity (HCVA), manifest refraction and intraocular straylight were determined at several time points during treatment and 1 month after discontinuing treatment. Straylight was measured using the van den Berg straylight meter (third generation). EDTRS charts (logMAR units) were used to assess HCVA. For both groups, only data for the right eyes were analyzed.ResultsStraylight (mean ± standard deviation) significantly fell from baseline (0.98 ± 0.13) to values recorded after 1 month (0.88 ± 0.13, p = 0.011), 3 months (0.88 ± 0.13, p = 0.004), 6 months (0.88 ± 0.13, p = 0.000) and 12 months (0.76 ± 0.12, p = 0.003) of treatment. One month after discontinuing CRT lens wear, straylight was still significantly lower than baseline (0.89 ± 0.13, p = 0.003). No correlations were observed between intraocular straylight and HCVA.ConclusionsGood refractive outcomes and reductions in straylight were observed in response to corneal refractive therapy for myopia. The reduction in straylight observed after discontinuing CRT warrents further investigation.  相似文献   

7.
PurposeTo assess the precision and reproducibility of the corneal biomechanical parameters, and their relationships with the intraocular pressure (IOP) measured with the Goldmann tonometer and a noncontact tonometer.MethodsReadings for biomechanical properties and for IOP measured with the Goldmann and noncontact tonometers, were taken on one randomly selected eye of 106 normal subjects, on each one of two measurement sessions. Measurements with the ocular response analyzer (ORA) and the noncontact tonometer were randomized, followed by the measurement of central corneal thickness and with the Goldmann tonometer.ResultsRepeatability coefficients for CCT, corneal hysteresis (CH) and corneal resistance factor (CRF) in Session 1 were ±0.01 μm, ±3.05 mmHg and ±2.62 mmHg, respectively. The mean CCT, CH, CRF, Goldmann and noncontact tonometry did not vary significantly between sessions. Reproducibility coefficients for CCT, CH and CRF were ±0.02 μm, ±2.19 mmHg and ±1.97 mmHg, respectively. Univariate regression analysis showed that CCT, CH and CRF significantly (P < 0.0001) correlated with the IOP measured with the Goldmann and noncontact tonometers (and with the differences between tonometers) in Session 1. There were no significant correlations with the differences between tonometers in Session 2. Multivariate analysis revealed a minimal effect of CCT on Goldmann measurements but a significant effect on those of the noncontact tonometer.ConclusionsMeasurement of the biomechanical properties of the cornea, using the ORA, are repeatable and reproducible, affect Goldmann tonometry less than noncontact tonometry, and have a minimal influence on the difference in measured intraocular pressure between tonometers.  相似文献   

8.
PurposeTo analyse the relationship between measured intraocular pressure (IOP) and central corneal thickness (CCT), corneal hysteresis (CH) and corneal resistance factor (CRF) in ocular hypertension (OHT), primary open-angle (POAG) and normal tension glaucoma (NTG) eyes using multiple tonometry devices.MethodsRight eyes of patients diagnosed with OHT (n = 47), normal tension glaucoma (n = 17) and POAG (n = 50) were assessed. IOP was measured in random order with four devices: Goldmann applanation tonometry (GAT); Pascal® dynamic contour tonometer (DCT); Reichert® ocular response analyser (ORA); and Tono-Pen® XL. CCT was then measured using a hand-held ultrasonic pachymeter. CH and CRF were derived from the air pressure to corneal reflectance relationship of the ORA data.ResultsCompared to the GAT, the Tonopen and ORA Goldmann equivalent (IOPg) and corneal compensated (IOPcc) measured higher IOP readings (F = 19.351, p < 0.001), particularly in NTG (F = 12.604, p < 0.001). DCT was closest to Goldmann IOP and had the lowest variance. CCT was significantly different (F = 8.305, p < 0.001) between the 3 conditions as was CH (F = 6.854, p = 0.002) and CRF (F = 19.653, p < 0.001). IOPcc measures were not affected by CCT. The DCT was generally not affected by corneal biomechanical factors.ConclusionThis study suggests that as the true pressure of the eye cannot be determined non-invasively, measurements from any tonometer should be interpreted with care, particularly when alterations in the corneal tissue are suspected.  相似文献   

9.
PurposeTo compare corneal hysteresis (CH) and corneal resistance factor (CRF) between eyes treated with small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (femto-LASIK).SettingBeyoğlu Eye Training and Research Hospital.DesignProspective comparative case series.MethodsSixty eyes from 30 patients with bilateral myopia or myopic astigmatism were studied. Inclusion criteria were spherical equivalent of subjective manifest refraction (SE) <10 diopters (D) and a difference ≤0.50 D between the SEs of both eyes. One eye of each patient was treated with SMILE, and the fellow eye underwent femto-LASIK. Randomization was performed using a sealed envelope system. The main outcome measures were CH and CRF measured preoperatively and postoperatively (1 and 6 months).ResultsPreoperative SE was similar in both groups (p = 0.852). CH and CRF values were reduced postoperatively in both groups compared to their corresponding preoperative values (p < 0.001). At the 6-month follow-up visit, the mean CH values in the SMILE and femto-LASIK groups were 8.95 ± 1.47 and 9.02 ± 1.27, respectively (p = 0.852), and the mean CRF values were 7.77 ± 1.37 and 8.07 ± 1.26, respectively (p = 0.380).ConclusionCH and CRF decreased after SMILE. There were no differences between SMILE and femto-LASIK treatments in postoperative CH or CRF values.  相似文献   

10.
PurposeTo assess the variation in central corneal thickness (CCT) following the instillation of oxybuprocaine hydrochloride (0.4%), in normal subjects.MethodsThis was a randomized, prospective study of CCT measurements (before and after the instillation of topical anaesthesia) obtained with the Topcon SP-3000P noncontact specular microscope, in 60 eyes of thirty subjects. The subjects’ mean age was 20 ± 1 years (mean ± SD). In each subject, one eye was treated with one drop of oxybuprocaine hydrochloride (HCl) and the fellow eye with one drop of normal saline (control). The SP-3000P CCT readings were first obtained before instillation (baseline) and monitored every 30 s after instillation of each eye drop for a period of 10 min.ResultsThe mean baseline CCT for oxybuprocaine was 526 ± 23 μm. Ten minutes after, it was 526 ± 24 μm. In the control, the mean CCT was 526 ± 27 μm, 10 min after it was 526 ± 28 μm. The mean variation in CCT measurement was ?0.7 ± 3.1 (5.5 to ?6.8 μm, 95% CI) for oxybuprocaine and ?0.6 ± 4.1 μm (7.5 and ?8.6 μm, 95% CI) for the fellow eyes (P > 0.05). There was no significant variation among the 20 CCT columns for either oxybuprocaine or the control group (P > 0.05 for both).ConclusionsOne drop of topical oxybuprocaine 0.4% did not cause a significant change in CCT at up to 10 min following instillation. However, higher differences were observed at 2.30 min and 4.30 min after instillation.  相似文献   

11.
PurposeTo investigate the accuracy of measuring intraocular pressure over a silicone hydrogel contact lens using Goldmann applanation tonometry in eyes with glaucoma.MethodsThis was a prospective, randomized study and enrolled 28 patients (28 right eyes) with primary open angle glaucoma. Intraocular pressure was taken with and without a silicone hydrogel contact lens (−0.50 D), in situ (using Goldmann applanation tonometry), in a randomized order of measurements. Statistical analysis was performed using paired t-test and Bland–Altman plot.ResultsThe mean difference (± standard deviation) found between intraocular pressure measurement without (mean 16.7 ± 3.2 mmHg) and with (mean 17.3 ± 3.0 mmHg) contact lens was found to be −0.57 ± 2.3 mmHg (95% confidence interval, −1.5 to 0.3). No significant statistical difference was found between the two groups with paired t-test (p = 0.19). The Bland Altman plot showed some evidence of increasing variability of differences between two measures of intraocular pressure, with increasing intraocular pressure. The 95% limits of agreement of the Bland Altman plot were unacceptably large (−5 mmHg to 3.9 mmHg).ConclusionAgreement between Goldmann applanation tonometry with and without contact lenses seems to be poor in patients with glaucoma, especially for high intraocular pressure.  相似文献   

12.
PurposeTo investigate the effect of long-term extended soft contact lens wear on limbal and central corneal cell morphology, and limbal architecture.MethodsEach participant attended a study visit involving in vivo confocal microscopy of central corneal and limbal epithelium. Scans were graded by five masked graders for three features: central epithelial irregularity, limbal epithelial irregularity and the prominence of palisades of Vogt. The variability of grades between different graders and the difference of grades between extended wearers and daily soft/non-contact lens wearers were assessed.ResultsNineteen participants (9 extended soft contact lens wearers and 10 daily soft/non-contact lens wearers) aged 31–65 years were enrolled in this study. Scans from 37 eyes were included in the analysis. Agreement between graders for each feature was moderate to good with inter class correlation >0.7. While there were no significant differences in central epithelial cell irregularity (p = 0.527) and the prominence of palisade of Vogt (p = 0.182) between extended or daily soft/non-contact lens wearers, limbal epithelial cell irregularity showed a trend with increased irregularity in extended soft contact lens wearers (p = 0.091).ConclusionsWhile no differences in limbal cell morphology and structure or central epithelial cell was found in this subjective grading study of extended wearers compared to daily soft/non-contact lens wearers, further studies using a larger sample size or a longitudinal study design are warranted.  相似文献   

13.
PurposeTo compare the topographic and biomechanical properties of corneas in eyes of patients with ichthyosis vulgaris (IV) and eyes of healthy individuals.MethodsThirty healthy individuals (control group) and 30 patients with IV (study group) were enrolled in this prospective study. Topographic measurements, including keratometry values, irregularity, and surface asymmetry index in the right eye of each participant were obtained using Scheimpflug camera with a Placido disc topographer (Sirius). Corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc) and Goldman-related intraocular pressure (IOPg) were measured using the Reichert Ocular Response Analyzer (ORA). Central corneal thickness (CCT) was also measured with ultrasonic pachymetry and the Sirius corneal topography system.ResultsTopographic parameters were not significantly different between both groups (p > 0.05). Although mean CH was not significantly different between the groups, the CRF was significantly lower in patients with IV (p = 0.249 and p = 0.005, respectively). The CCT was significantly lower in patients with IV compared to healthy controls (p < 0.001). The IOPg and IOPcc were significantly lower in the patients with ichthyosis than in healthy controls (p = 0.001 and p = 0.004, respectively).ConclusionsThe study demonstrated that while the eyes of patients with IV had corneal topographic findings and corneal hysteresis similar to those of healthy controls, some of corneal biomechanical properties such CRF and CCT and IOP values such as IOPg and IOPcc were significantly lower in patients with IV. These results should be taken into account when planning a corneal refractive surgery and glaucoma screening for patients with IV.  相似文献   

14.
PurposeThe aim of this cross-over study was to investigate the changes in corneal thickness, anterior and posterior corneal topography, corneal refractive power and ocular wavefront aberrations, following the short term use of rigid contact lenses.MethodFourteen participants wore 4 different types of contact lenses (RGP lenses of 9.5 mm and 10.5 mm diameter, and for comparison a PMMA lens of 9.5 mm diameter and a soft silicone hydrogel lens) on 4 different days for a period of 8 h on each day. Measures were collected before and after contact lens wear and additionally on a baseline day.ResultsAnterior corneal curvature generally showed a flattening with both of the RGP lenses and a steepening with the PMMA lens. A significant negative correlation was found between the change in corneal swelling and central and peripheral posterior corneal curvature (all p  0.001). RGP contact lenses caused a significant decrease in corneal refractive power (hyperopic shift) of approximately 0.5 D. The PMMA contact lenses caused the greatest corneal swelling in both the central (27.92 ± 15.49 μm, p < 0.001) and peripheral (17.78 ± 12.11 μm, p = 0.001) corneal regions, a significant flattening of the posterior cornea and an increase in ocular aberrations (all p  0.05).ConclusionThe corneal swelling associated with RGP lenses was relatively minor, but there was slight central corneal flattening and a clinically significant hyperopic change in corneal refractive power after the first day of lens wear. The PMMA contact lenses resulted in significant corneal swelling and reduced optical performance of the cornea.  相似文献   

15.
PurposeTo investigate the efficacy and safety of a fenestrated and channelled soft contact lens (F-SCL) compared to a standard and non-fenestrated soft contact lens (S-SCL) in experienced soft contact lens (SCL) wearers.MethodsThis was a randomised, crossover, single-blinded (subject), and multicentre clinical trial. Sixteen experienced SCL wearers were randomly divided into two groups (FS and SF). The FS group first wore F-SCLs followed by S-SCLs, each for 10 days, separated by a 1-week washout period, whereas the SF group wore the S-SCLs first and crossed over to F-SCLs in the same manner. The F-SCLs were designed with three equally spaced, symmetrical fenestrations and a partial-thickness, connecting, circumferential channel on the back surface of the mid-periphery of the lens. Measurement of central corneal thickness using ultrasonic pachymetry was performed on the day of screening, after the 1-week washout period, and after 10 days of wearing each kind of lens, based on which central corneal swelling was calculated and compared. One eye in each subject was chosen at random for analysis.ResultsCentral corneal swelling was 1.92 ± 1.73% vs. 5.26 ± 2.14% in F-SCLs vs. S-SCLs wearers, which was statistically significant (P < 0.001). There was no significant difference between the groups in terms of SCL-corrected visual acuity or SCL-related adverse events.ConclusionThe use of F-SCLs led to reduced corneal swelling compared to S-SCLs. The newly incorporated features appear to improve tear mixing and thereby the oxygen supply to the cornea, which results in reduced corneal oedema.  相似文献   

16.
PurposeTo evaluate the refractive and corneal topographical changes of overnight orthokeratology in myopia with two brands of contact lenses.MethodsFourty-four eyes of 22 myopic patients with manifest refraction spherical equivalent (MRSE) of −1.00 to −5.00 D (cylinder  −1.0) were fitted with either DreamLens (Hanita Lenses Investments, Hanita, Israel) (group A) or Rinehart–Reeves (R&R; Danker Laboratories, Sarasota, FL) (group B) reverse-geometry lenses. Each subject eye was evaluated in regards to the uncorrected and corrected distance visual acuities, manifest refraction, slit lamp biomicroscopy, and corneal topography at each follow-up examination.ResultsThe follow-up was 1 year. For groups A and B, the mean uncorrected distance visual acuity was −0.02 ± 0.10 log MAR (20/20) and −0.08 ± 0.12 log MAR (20/20) respectively at year-1 examination. The mean MRSE decreased from −2.70 ± 0.9 D to −0.50 ± 0.08 D in group A and −3.1 ± 1.1 to −0.62 ± 0.18 D in group B at week-1; and remained stable thereafter in each group. For both groups, starting with week-1, the mean anterior best-fit sphere (ABFS) was statistically significantly flatter from baseline. A high correlation was found between the change in apical corneal power (ACP) and MRSE (r1 = 0.79, r2 = 0.71), and there was a good correlation between the change in ABFS and MRSE (r1 = 0.67, r2 = 0.64) in both groups. No significant ocular adverse events were observed during study.ConclusionsBoth types of contact lenses safely and effectively decreased the myopic refractive error at 1 year follow-up. The refractive effect was mainly induced by the changes in the anterior corneal shape and the ACP.  相似文献   

17.
PurposeTo investigate usage of soft contact lens (SCL) on post-operative pain relief and daily, activity due to pterygium surgery.MethodsAutograft pterygium surgery was performed to 63 eyes of 63 patients. After surgery in 30, eyes of 30 patients in group-1, SCL was placed on the cornea. In 33 patients of group-2, antibiotic, pomade was applied and tightly covered with bandage. Follow-up visits were performed on 24th and, 48th h after the surgery. Re-epithelization time and pain scores were compared.ResultsPatients’ 24th h pain score was 2.96 ± 0.76 in group-1, and 4.15 ± 0.75 in group-2. The mean, pain score for 48 h was 1.66 ± 0.66 in group-1, and 2.96 ± 0.68 in group-2. Patients’ pain scores for, both 24th h and 48th h were lower in group-1 (p < 0.01). The mean re-epithelization times in, group 1 and 2 were 48 and 56.7 h, respectively. Corneal re-epithelization is improved in patients, with SCL compared to group 2.ConclusionSCL seems effective on reducing post-operative pain and eye stinging, and may accelerate, corneal re-epithelization and maintaining daily activities.  相似文献   

18.
PurposeTo investigate the differences of functional visual acuity (FVA) and high order aberrations (HOAs) in relation to tinted and clear hydrogel soft contact lens (SCL) wear.MethodsA prospective comparative study was performed in 16 eyes of 16 healthy volunteers. Dynamic visual acuity (using a FVA measurement system) and higher-order aberrations (using a wavefront sensor) were compared in subjects wearing two types of soft contact lenses: 1-day Acuvue® (Vistakon, Jacksonville, FL) clear and the 1-day Acuvue® DefineTM (Vistakon, Jacksonville, FL) tinted lens. The blink rates were recorded during FVA testing. The correlation between the difference of HOAs and differences in FVA values was analyzed.ResultsThe mean LogMAR FVA scores with clear and tinted SCLs were 0.07 ± 0.13 and 0.14 ± 0.17 (P < 0.05). The mean blink frequencies with clear and tinted SCL wear were 18.4 ± 8.3 and 25.3 ± 4.7 blinks/min (P < 0.05). Both 3rd-order aberrations and total HOAs showed statistically significant differences between the two types of soft contact lenses for 6 mm pupil measurements (P < 0.05). A significant positive linear correlation was observed between ΔHOAs and ΔLogMAR FVA for 6 mm pupil measurements (R = 0.53, P = 0.04).ConclusionsTinted contact lens wear appears to induce a reduction in optical quality. Functional visual acuity measurement is a useful procedure to study the changes of visual performance and quality in tinted contact lens wear.  相似文献   

19.
PurposeTo compare intraocular pressure (IOP) measured with ocular response analyzer (ORA) with and without soft contact lenses (CL) on eye.MethodsGoldmann correlated intraocular pressure (IOPg) and corneal compensated intraocular pressure (IOPcc) were measured in 56 eyes of 28 subjects without any ocular pathology, using ORA. One eye was fitted with Narafilcon A (1-Day Acuvue True Eye, Johnson & Johnson) and the other eye with Nelfilcon A (Daily AquaComfort Plus, Ciba Vision), each with −3.00D and IOPg and IOPcc were again measured over CL. The variation in the IOP with and without CL was determined.ResultsOut of 28 subjects, 54% (15) were female. Mean age of the subjects was 29.4 ± 9.8 years. Both the IOPg and IOPcc when measured with CL, were found statistically significantly lower than without CL (p < 0.05). In subjects wearing Narafilcon A lens, IOPg and IOPcc were found 0.88 ± 2.04 mmHg and 1.55 ± 2.16 mmHg lower than without CL, respectively. Similarly, with Nelfilcon A lens, IOPg and IOPcc were found to be 1.03 ± 1.93 mmHg and 1.62 ± 3.12 mmHg lower, respectively. IOPcc was highly affected and underestimated by more than 3 mmHg in upto 36% of the subjects.ConclusionMeasurement of IOP over minus (−3.00D) CL with ORA is dependent upon CL properties when measured in normal IOP population. It showed lower IOP over Narafilcon A and Nelfilcon A soft CL in comparison to the pressures measured without lenses. IOPg was found less affected by CL. For the accurate measurement of IOP with ORA, CL should be removed.  相似文献   

20.
PurposeTo compare conventional method of contact lens fitting with software based contact lens fitting using Medmont corneal topographer in eyes with nebular and macular corneal scars.MethodsFifteen participants who were diagnosed with nebular and macular scars were fitted with rigid gas permeable lenses using conventional method of contact lens fitting. During the lens dispensing visit, participants underwent Medmont corneal topography. Agreement between the two methods of contact lens fitting was studied.ResultsParameters of contact lenses which were concluded using conventional method was compared to that of software based fitting. Mean difference in base curve of contact lens between the two methods was 0.094 mm ± 0.147 mm (95% CI: +0.383 to −0.194). Mean difference in diameter of contact lens between the two methods was 0.16 mm ± 0.172 mm (95% CI: +0.497 to −0.177). Contact lens parameters that were achieved using two different methods of fitting showed good correlation. Correlation coefficients, as comparison of two methods in base curve and diameter were 0.96 (P < 0.05) and 0.94 (P < 0.05), respectively.ConclusionSoftware based contact lens fitting would be useful for contact lens practitioners to predict initial base curve of contact lens in corneal scars.  相似文献   