首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
In this study, pilot scale experiments were carried out to examine membrane fouling occurring in membrane bioreactors (MBR) with or without pre-treatment (coagulation/sedimentation). Especially, the influence of suspension viscosity and dissolved organic matter (DOM) on membrane fouling was investigated. The pre-coagulation/sedimentation process improved the performance of a MBR in terms of membrane permeability by controlling irreversible fouling and formation of thick cake layer. The upper limit of MLSS concentration for an efficient operation in MBR without pre-treatment was suggested to be around 10 g/L based on the measurement of suspension viscosity. In this study, it was difficult to directly relate membrane fouling to DOM detected in the membrane chamber. A series of laboratory scale dead-end filtration experiments was carried out to investigate which fractions in biomass suspension would be the most influential in the deterioration of membrane permeability. Based on the dead-end tests, it was shown that the deterioration of membrane permeability was mainly caused by the colloidal particle fraction in the biomass suspension.  相似文献   

2.
Membrane fouling can be divided into two types: reversible fouling and irreversible fouling. The former can be easily canceled by physical cleaning (e.g., backwashing) while the latter needs chemical cleaning to be mitigated. For more efficient use of membranes, the control of irreversible membrane fouling is of importance. In this study, the effectiveness of pre-coagulation/sedimentation on irreversible membrane fouling was investigated, based on the pilot-scale operation of the membrane unit installed at an existing water purification plant. The membrane employed was a low-pressure ultrafiltration (UF) membrane made of polysulfone and having a molecular weight cut-off of 750,000 daltons. Although pre-coagulation/ sedimentation significantly mitigated membrane fouling mainly through the reduction of reversible membrane fouling, the degree of irreversible fouling was not reduced by the pre-treatment. This was because the irreversible fouling observed during this study was mainly attributed to polysaccharides/protein like fractions of organic substances that cannot be efficiently removed by coagulation/sedimentation. Aluminium used as coagulant was thought to cause irreversible fouling to some extent but did not in the pilot operation, which could probable be explained by the fact that coagulation was conducted at relatively high pH (7.0) in this study.  相似文献   

3.
In this research, we investigated the variation of transmembrane pressure and permeate water quality in pre-coagulation and sedimentation with iron based coagulant, and chlorination of feed water for PVDF (Polyvinylidene fluoride) based MF membrane filtration. NaCIO was fed to the membrane module at a dosage of 0.5 mg/L and maintained during filtration. To observe the effect of raw water, three types of raw and processed waters, including river surface water, coagulated water and coagulated-settled water, were employed. In the case of river surface water, the transmembrane pressure increased abruptly in 500 hours operation. On the contrary, no significant increase in transmembrane pressure was observed for coagulated water and coagulated-settled water for 1200 hours operation. The turbidity of permeate was lower than the detection limit for all applied waters. The removal efficiency for humic substances in coagulated water and coagulated-settled water was approximately ten times higher than that in surface river water. And, the removal efficiency for TOC and DOC was approximately two times higher than that in surface river water. From the results of the operation, it can be observed that it is possible to maintain stable operation at 0.9 m(3)/m(2)-day filtration flux through a combination of pre-coagulation and pre-chlorination. However, the water quality of permeate was the best when the pre-coagulation-sedimentation process was combined with pre-chlorination. With respect to fouling reduction and operation efficiency increase in membrane filtration, the pre-coagulation/sedimentation process is a promising alternative.  相似文献   

4.
组合工艺控制有机物及消毒副产物前体物的特性研究   总被引:3,自引:0,他引:3  
通过XAD-8树脂将水中有机物分成疏水性、亲水性两部分,对传统常规处理工艺(混凝气浮、过滤)和深度处理工艺(臭氧氧化、生物活性炭)出水的DOC,UV254THMFP,HAAFP指标以及疏水、亲水有机物去除率进行了检测分析。结果表明,生物活性炭(BAC)单元工艺能同时去除疏水性和亲水性两种有机物,且两者去除率均为最高。其次去除效果较好的是传统的常规工艺。臭氧工艺具有将天然的疏水性有机物氧化成可生化降解的亲水性小分子有机物的特点,在预臭氧+常规以及O3-BAC组合工艺中,起到了强化去除有机物和消毒副产物前体物的效果。  相似文献   

5.
Characterization of fouled membranes is the first step towards a good understanding of membrane fouling nature and thus formulating effective engineering measures for fouling prevention and control. In this study, fouled membrane fibres collected from a pilot scale membrane enhanced biological phosphorus removal (MEBPR) process were systematically examined. Several analytical tools, including scanning electron microscopy (SEM), conventional optical microscopy (COM), energy dispersive X-ray (EDX) microanalysis, matrix assisted laser desorption/ionization--mass spectrometry (MALDI-MS) analysis, and conventional chemical analysis techniques were used. The results indicated that membrane fouling in the MEBPR process was mainly of an organic nature, and most extractable foulants were carbohydrates and humic or humic-like substances. Unlike in other wastewater treatment membrane bioreactors, microbial growth on fouled membranes was not substantial, probably due to the vigorous aeration applied and the strong hydrodynamic conditions within the membrane pore structure. After a period of sludge filtration, membrane surfaces became more hydrophobic and the resultant hydrophobic interactions between the fouled membranes and mixed liquor constituents might have accelerated the fouling process.  相似文献   

6.
探讨了深圳某给水厂原水中NO2--N含量对预臭氧化工艺效果的影响.室内静态试验结果表明,深圳原水的O3消耗量与NO2--N完全去除的比例为51(O3消耗量/NO2--N的理论值约为3.4);当原水NO2--N<0.1 mg/L时,NO2--N对预臭氧工艺无影响,而当NO2--N>0.18 mg/L后,预臭氧化工艺去除有机物效果(以UV254表征)明显降低;水厂生产结果表明,NO2--N含量对预臭氧化工艺中的臭氧投加量及处理效果具有显著影响,原水中较高的NO2-N还会对后续混凝沉淀和砂滤工序造成不良影响,原水经生物预处理和封闭管道改造后,NO2--N由0.12~1.85 mg/L降低到0.02~0.14 mg/L,CODMn去除率明显升高.  相似文献   

7.
If coagulation is not completely successful and produces aggregates which are too small, fouling may increase. In some cases, a deep-bed filter could perhaps provide a solution. The paper examines these effects using experimental results for different waters. Activated sludge effluents, stormy seawater containing microalgae and spent filter backwash water (SFBW) were coagulated by alum or ferric chloride. Sand filtration tests were carried out. Tests were performed in a membrane filtration stirred cell, filtration pilot plant equipped with SDI analyzer (seawater) and pilot UF plant (SFBW). For activated sludge effluent, alum residual ratio curves of turbidity and total particle count (TPC) followed one another. With ferric chloride, low coagulant dosage showed negative turbidity removal. Contact granular filtration reduced membrane fouling intensity. Increasing the dose resulted in higher improvement in membrane flux. For seawater, a filter run period under storm conditions reached 35 hours with satisfactory filtrate quality. An iron chloride dose of 0.3 mg/l during normal conditions and 0.5 mg/l for stormy condition should be injected, mixed well before the filters, while maintaining 10 m/hr filtration rate and pH 6.8 value. For SFBW, alum flocculation pretreatment of SFBW was effective in reducing turbidity, TPC, viruses and protozoa. SFBW settling prior to flocculation did not enhance turbidity and TPC removal. The largest remaining particle fraction after alum flocculation was 3-10 microm in size, both Cryptosporidium and Giardia are found in this size range. Coagulation enhanced the removal of small size particles, a positive impact on reducing membrane fouling potential.  相似文献   

8.
Drinking water sources in Norway are characterized by high concentrations of natural organic matter (NOM), low alkalinity and low turbidity. The removal of NOM is therefore a general requirement in producing potable water. Drinking water treatment plants are commonly designed with coagulation direct filtration or NF spiral wound membrane processes. This study has investigated the feasibility and potential of a hybrid process combining ozonation and biofiltration with a rotating disk membrane for treating drinking water with high NOM concentrations. Ozonation will oxidize the NOM content removing colour and form biodegradable organic compounds, which can be removed in biological filters. A constructed water was used in this study which is representative of ozonated NOM-containing water. A rotating membrane disk bioreactor downstream the ozonation process was used to carry out both the biodegradation as well as biomass separation in the same reactor. Maintenance of biodegradation of the organic matter while controlling biofouling of the membrane and acceptable water production rates was the focus in the study. Three operating modes were investigated. Removal of the biodegradable organics was consistent throughout the study indicating that sufficient biomass was maintained in the reactor for all operating conditions tested. Biofouling control was not achieved through shear-induced cleaning by periodically rotating the membrane disks at high speed. By adding a small amount of sponges in the membrane chamber the biofouling could be controlled by mechanical cleaning of the membrane surface during disk rotation. The overall results indicate that the system can favorably be used in an ozonation/biofiltration process by carrying out both biodegradation as well as biomass separation in the same reactor.  相似文献   

9.
This study focuses on the experimental investigation to identify the effect of PAC at high concentrations on the fouling of membranes. A pilot-scale experimental apparatus was installed at a water treatment plant located downstream of Nakdong river basin, Korea. Effluent of rapid sand filter was used as influent of the system, which consists of PAC bio-reactor, submerged membrane module (hollow fiber with pore size 0.1 m) and air supply facility. PAC was dosed at 40 g/L initially and it was not replaced during the operation period. Suction type filtration was carried out at intervals of 12 min. suction and 3 min. idling. At the initial flux 0.36 m/d, the system could be operated stably for around 90 days at target trans-membrane pressure (TMP) of 40 kPa. Among total resistance of membrane filtration, cake and gel layer resistance, Rc+Rg, was the dominant fraction (more than 90% of the total) to increase the filtration pressure, which means that the filtration resistance could be controlled by the PAC cake layer and then irreversible membrane fouling could be prevented. Three minutes air backwashing every 3 days could extend the operation period to 127 days. Organics were analyzed in terms of molecular weight structure. The influent of the system consists of 15.0% and 74.4% of hydrophobic and hydrophilic natural organic matter (NOM), respectively. Hydrophobic and hydrophilic (electrostatic) interaction was the main factor on fouling of the membrane in the reactor. Hydrophobic fraction decreased slightly in the effluent, which means hydrophobic NOM removal in the reactor by adsorption. Organics accumulated in the membrane were extracted for analysis after a certain period of operation. The fraction of hydrophobic and hydrophilic organics was 41.4% and 38.9%, respectively. On the basis of the experimental results, the hydrophobic organics were the major materials causing the fouling of the membrane, which should be changed to other types of material.  相似文献   

10.
On-site greywater treatment and reuse in multi-storey buildings.   总被引:1,自引:0,他引:1  
The paper presents a study of a pilot plant treating light greywater for seven flats. The pilot plant combines biological treatment (RBC) with physicochemical treatment (sand filtration and disinfection). The pilot plant produced effluent of excellent quality, meeting the urban reuse quality regulations, and was very efficient in TSS turbidity and BOD removal: 82%, 98% and 96%, respectively. COD removal was somewhat lower (70-75%) indicating that the greywater may contain slowly-biodegradable organics. The RBC (attached growth biological system) was able to retain most of the solids as a result of bioflocculation; further it was proven to have very stable and reliable performance. Faecal coliforms and heterotrophic reductions were very high (100% and 99.99%, respectively) producing effluent that also met drinking water standards. The combination of low organic matter, nutrients and microbial indicators reduces the regrowth and fouling potentials in the reuse system, thus ensuring safe reuse of the treated greywater for toilet flushing.  相似文献   

11.
Two processes in the pilot plant were studied and compared to reduce the disinfection byproduct risk of the potable finished water of Feng-shan treatment utility in Taiwan. For 5 months study, two processes have both demonstrated to achieve a significant removal on the organic precursors of DBPs, including NPDOC and A-254. With the analysis of molecular weight distribution of organics in raw water, the study found the post ozonation plus BAC can provide additional enhancement in degrading organic contents. A process of coagulation/sedimentation/rapid sand filtration/post ozonation/BAC would be suggested as the advanced treatment process improving the supply quality of Feng-shan utility.  相似文献   

12.
Understanding the fate of effluent organic matter (EfOM) and natural organic matter (NOM) through riverbank filtration is essential to assess the impact of wastewater effluent on the post treatment requirements of riverbank filtrates. Furthermore, their fate during drinking water treatment can significantly determine the process design. The objective of this study was to characterise bulk organic matter which consists of EfOM and NOM during riverbank filtration using a suite of innovative analytical tools. Wastewater effluent-derived surface water and surface water were used as source waters in experiments with soil columns. Results showed the preferential removal of non-humic substances (i.e. biopolymers) from wastewater effluent-derived surface water. The bulk organic matter characteristics of wastewater effluent-derived surface water and surface water were similar after 5 m soil passage in laboratory column experiment. Humic-like organic matter in surface water and wastewater effluent-derived surface water persisted through the soil passage. More than 50% of total dissolved organic carbon (DOC) removal with significant reduction of dissolved oxygen (DO) was observed in the top 50 cm of the soil columns for both surface water and wastewater effluent-derived surface water. This was due to biodegradation by soil biomass which was determined by adenosine triphosphate (ATP) concentrations and heterotrophic plate counts. High concentrations of ATP in the first few centimeters of infiltration surface reflect the highest microbial activity which correlates with the extent of DOC reduction. Good correlation of DOC removal with DO and biomass development was observed in the soil columns.  相似文献   

13.
微滤膜法饮用水处理工艺中膜污染控制的研究   总被引:1,自引:1,他引:0  
采用150 m3/d的微滤膜法饮用水处理中试研究了膜污染的控制方法,包括反冲洗、混凝预处理以及在线的通量维护措施--EFM(Enhance Flux Maintenance).结果表明,单独采用水反冲洗时,膜比通量的恢复效果较差,采用气水联合反冲洗时效果明显好转,膜污染速率降低为原来的44%.混凝预处理能够很好地控制膜污染,其主要作用在于降低滤饼层阻力和减轻不可逆膜污染.在研究的范围内,混凝剂投加量越高,对膜污染的控制作用越好.EFM能够阶段性地去除膜污染,有效地恢复膜比通量,因而能够显著地延长化学清洗周期,减少化学清洗频率.  相似文献   

14.
夏萍  叶辉  周新宇  张东  王铮 《给水排水》2012,38(1):119-122
为了考察UV/H2O2工艺对微量有机物的去除效果,在砂滤池出水后接UV/H2O2高级氧化中试设备,并投加了特征污染物(阿特拉津、臭味物质2-MIB与Geosmine)。结果表明,UV/H2O2工艺对Geosmine去除效果最好,去除率能达到90%以上,对MIB和阿特拉津的去除效果比较接近,去除率均在50%以上,对UV254的去除率为20%~38%。在UV/H2O2工艺中无溴酸盐生成。  相似文献   

15.
One of the main problems for seawater reverse osmosis desalination is membrane fouling associated with natural organic matter. Bisphenol-A (BPA) and 17alpha-ethinylestradiol (EE2) are well-known endocrine-disrupting compounds that have been detected in wastewater and seawater. In this study, the contribution of carbon nanotubes (CNTs, single-walled carbon nanotubes) to membrane fouling control and the potential adsorption mechanisms of BPA and EE2 were investigated using artificial seawater (ASW) in a bench scale ultrafiltration (UF) membrane coupled with CNTs. For high ionic strength ASW, UVA254 nm is a good alternative for highly aromatic dissolved organic carbon (DOC) determination, with a very strong linear relationship (R2 > or = 0.99) with increasing DOC concentrations. Approximately 80% of DOC in ASW was rejected by the CNT-UF system where 31% of DOC was removed due to adsorption by CNTs. The presence of CNTs shows a 20% increase in membrane flux in ASW. A strong linear correlation between retention and adsorption of BPA and EE2 was obtained. The percentage of adsorption/retention of BPA and EE2 in UF-CNTs follows the order: 94.0/96.6 (DI + CNTs, EE2) > 86.2/90.0 (ASW + CNTs, EE2) > 73.6/78.9 (DI + CNTS, BPA) > or = 74.1/77.3 (ASW + CNTS, BPA) > 29.8/29.8 (ASW, EE2) approximately equal to 27.3/27.3 (ASW, BPA) > or = 25.3/25.3 (DI, EE2) approximately equal to 24.8/24.8 (DI, BPA). This indicates that retention by the UF-CNT system is mainly due to adsorption. Overall, EE2 adsorption was greater than BPA during the UF-CNT experiments, presumably due to the higher hydrophobicity of EE2 than BPA.  相似文献   

16.
Investigation of membrane fouling by synthetic and natural particles.   总被引:1,自引:0,他引:1  
The biggest impediment for applying membrane processes is fouling that comes from mass flux better (such as particle and organic matter) to the membrane surface and its pores. Numerous research articles have indicated that either particles or natural organic matter (NOM) has been the most detrimental foulant. Therefore, the role of particles in membrane fouling was investigated with two synthetic waters (having either particles alone or particles with simple organic matter) and a natural water. Membrane fouling was evaluated with flux decline behavior and direct images from scanning electron microscopy. The results showed that the combined fouling by kaolin and dextran (a simple organic compound selected as a surrogate for NOM) showed no difference from the fouling with only the organic matter. The similarity might stem from the fact that dextran (i.e., polysaccharide) has no ability to be adsorbed on the clay material, so that the polysaccharide behaves the same with respect to the membrane with or without clay material being present. In contrast to kaolin, the natural particles showed a dramatic effect on membrane fouling.  相似文献   

17.
In order to optimize some operational conditions of MBR systems, a MBR pilot plant equipped with a submerged hollow fibre membrane module was employed in this study. The pilot MBR was fed with real municipal wastewater and the filtration flux, backwashing interval, aeration frequency and temperature were varied. A filtration flux below 25 I/m2h is generally recommended, at below this flux, the MBR operated at sub-critical flux conditions, the filter cake was minimized and membrane fouling was mainly attributed to the membrane pore blocking. Moreover, the membrane fouling, at below 25 I/m2h, was more reversible to backwashing; above this value, backwashing became less efficient to clean the membrane. Less frequent backwashing (e.g. 600 s filtration/45 s backwashing) decreased the amount of fouling irreversible to backwashing and its performance was superior to that of frequent backwashing (e.g. 200 s filtration/15 s backwashing). The MBR suffered more fouling at low temperature conditions (e.g. at 13-14 degrees C) than at high temperature conditions (e.g. at 17-18 degrees C). A conceptual model was built up and successfully interpreted this temperature effect.  相似文献   

18.
Natural organic matter (NOM) is known to be the worst foulant in the membrane processes, but the complexities of NOM make it difficult to determine its effects on membrane fouling. Therefore, simple organic compounds (surrogates for NOM) were used in this research to investigate the fouling mechanisms in ultrafiltration. Previous research on NOM components in membrane processes indicated that polysaccharides formed an important part of the fouling cake. Three polysaccharides (dextran, alginic acid, and polygalacturonic acid) and a smaller carbohydrate (tannic acid) were evaluated for their removal in softening (the treatment process in the City of Austin). Two polysaccharides (dextran and alginic acid) were selected and further investigated for their effects on membrane fouling. The two raw organic waters (4 mg/L C) showed quite different patterns of flux decline indicating different fouling mechanisms. Softening pretreatment was effective to reduce flux decline of both waters. The SEM images of the fouled membrane clearly showed the shapes of deposited foulants. The high resolution results of the XPS spectra showed substantially different spectra of carbon, C(1s), in the membrane fouled by two raw organic waters. The XPS was beneficial in determining the relative composition of each fouling material on the membrane surface.  相似文献   

19.
低浊高色富含有机物地表水难于混凝,试验采用“混凝-溶气气浮”(“混凝-DAF”)工艺处理此类水,并与常规“混凝-沉淀”工艺进行了比较。结果表明,“混凝-DAF”工艺在较低投药量时能取得更好的处理效果;对于“混凝-DAF”工艺,增大混凝剂投量后出水浊度基本不变,但出水色度及CODMn可进一步降低;“混凝-DAF”工艺去除水中有机物的能力优于“混凝-沉淀”工艺。最后,对“混凝-DAF”工艺去除水中有机污染物的机理进行了探讨。  相似文献   

20.
The role of particle separation on the performance of ozone-biological activated carbon (BAC) was evaluated based on the analyses of the fate of organic substances in the process. Pilot plant studies were carried out using eutrophic lake water as raw water. The ozonation not only converted refractory organic matter into biodegradable matter but also particulate organic carbon (POC) into dissolved organic carbon (DOC). Total decrease in adsorbable and non biodegradable DOC fraction (ADOC) after ozonation was only 1690 of the influent into the biofiltration process followed by ozonation. However, the ozone-BAC process before membrane separation could reduce organic loading to membrane system. The smaller loading to microfiltration will result in long intervals of back washing and less frequent membrane fouling. Membrane separation before ozonation removed not only POC but also a part of DOC and could prevent dissolution of POC during ozonation. The decreases in ADOC by membrane and ozonation were 20% and 37% of the influent ADOC, respectively. The total decrease in ADOC for membrane process followed by ozonation was 57%. The separation of particulate matter will decrease loading of ADOC onto BAC significantly and, therefore, will extend service life of BAC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号