首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
Gold, platinum and tungsten films were deposited by low energy input (7 mA, 450 V), or high deposition rate (80 mA, 1500 V), diode sputter coating and by ion beam sputter coating. Film structures on Formvar coated grids and on the surface of coated erythrocytes, resin embedded, sectioned, and recorded at high magnification in a TEM were compared using computer-assisted measurements and analysis of film thickness and grain size. The average grain size of the thinnest gold and platinum films was relatively independent of the mode or rate of deposition but as the film thickness increased, significant differences in grain size and film structure were observed. Thick platinum or gold films deposited by low energy input sputter coating contained large grain size and electron transparent cracks; however, more even films with narrower cracks but larger grain size were produced at high deposition rates. Ion beam sputter coated gold had relatively large grain size in 10 nm thick films, but beyond this thickness the grains coalesced to form a continuous film. Platinum films deposited by ion beam sputter coating were even and free of electron transparent cracks and had a very small grain size (1–2 nm), which was relatively independent of the film thickness. Tungsten deposition either by low energy input or ion beam sputter coating resulted in fine grained even films which were free of electron transparent cracks. Such films remained granular in substructure and had a grain size of about 1 nm which was relatively independent of film thickness. Tungsten films produced at high deposition rates were of poorer quality. We conclude that thick diode sputter coated platinum and gold films are best deposited at high deposition rates provided the specimens are not heat sensitive, the improvement in film structure being more significant than the slight increase in grain size. Thick diode or ion beam sputter coated gold films should be suitable for low resolution SEM, and thin discontinuous gold films for medium resolution SEM. Diode sputter coated platinum should be suitable for medium resolution SEM and ion beam sputter coated platinum for medium and some high resolution SEM. 1–5 nm thick tungsten films, deposited by low energy input or ion beam sputter coating should be suitable for high resolution SEM, particularly where contrast is of less importance than resolution.  相似文献   

2.
Cell biologists probing the physiologic movement of macromolecules and solutes across the fenestrated microvascular endothelial cell have used electron microscopy to locate the postulated pore within the fenestrae. Prior to the advent of in-lens field-emission high-resolution scanning electron microscopy (HRSEM) and ultrathin m et al coating technology, quick-freeze, platinum-carbon replica and grazing thin-section transmission electron microscopy (TEM) methods provided two-dimensional or indirect imaging methods. Wedge-shaped octagonal channels composed of fibrils interwoven in a central mesh were depicted as the filtering structures of fenestral diaphragms in images of platinum replicas enhanced by photographic augmentation. However, image accuracy was limited to replication of the cell surface. Subsequent to this, HRSEM technology was developed and provided a high-fidelity, three-dimensional topographic image of the fenestral surface directly from a fixed and dried bulk adrenal specimen coated with a 1 nm chromium film. First described from TEM replicas, the “flower-like” structure comprising the fenestral pores was readily visualized by HRSEM. High-resolution images contained particulate ectodomains on the lumenal surface of the endothelial cell membrane. Particles arranged in a rough octagonal shape formed the fenestral rim. Digital acquisition of analog photographic recordings revealed a filamentous meshwork in the diaphragm, thus confirming and extending observations from replica and grazing section TEM preparations. Endothelial cell pockets, first described in murine renal peritubular capillaries, were observed in rhesus and rabbit adrenocortical capillaries. This report features recent observations of fenestral diaphragms and endothelial pockets fitted with multiple diaphragms utilizing a Schottky field-emission electron microscope. In-lens staging of bulk and thin section specimens allowed tandem imaging in HRSEM and scanning TEM modes at 25 kV.  相似文献   

3.
Confocal microscopy imaging of cells allows to visualize the presence of specific antigens by using fluorescent tags or fluorescent proteins, with resolution of few hundreds of nanometers, providing their localization in a large field‐of‐view and the understanding of their cellular function. Conversely, in scanning electron microscopy (SEM), the surface morphology of cells is imaged down to nanometer scale using secondary electrons. Combining both imaging techniques have brought to the correlative light and electron microscopy, contributing to investigate the existing relationships between biological surface structures and functions. Furthermore, in SEM, backscattered electrons (BSE) can image local compositional differences, like those due to nanosized gold particles labeling cellular surface antigens. To perform SEM imaging of cells, they could be grown on conducting substrates, but obtaining images of limited quality. Alternatively, they could be rendered electrically conductive, coating them with a thin metal layer. However, when BSE are collected to detect gold‐labeled surface antigens, heavy metals cannot be used as coating material, as they would mask the BSE signal produced by the markers. Cell surface could be then coated with a thin layer of chromium, but this results in a loss of conductivity due to the fast chromium oxidation, if the samples come in contact with air. In order to overcome these major limitations, a thin layer of indium‐tin‐oxide was deposited by ion‐sputtering on gold‐decorated HeLa cells and neurons. Indium‐tin‐oxide was able to provide stable electrical conductivity and preservation of the BSE signal coming from the gold‐conjugated markers. Microsc. Res. Tech. 78:433–443, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

4.
This paper describes the use of sputter coating to prepare detergent-extracted cytoskeletons for observation by scanning (SEM), scanning transmission (STEM), inverted contrast STEM, and transmission (TEM) electron microscopy. Sputtered coats of 1–2 nm of platinum or tungsten provide both an adequate secondary electron signal for SEM and good contrast for STEM and TEM. At the same time, the grain size of the coating is sufficiently fine to be just at (platinum) or below (tungsten) the limit of resolution for SEM and STEM. In TEM, the granular structure of platinum coats is resolved, and platinum decoration artifacts are observed on the surface of structures. The platinum is deposited as small islands with a periodic distribution that may reveal information about the underlying molecular structure. This method produces samples that are similar in appearance to replicas prepared by low-angle rotary shadowing with platinum and carbon. However, the sputter-coating method is easier to use; more widely available to investigators; and compatible with SEM, STEM, and TEM. It may also be combined with immunogold and other labeling methods. While TEM provides the highest resolution images of sputter-coated cytoskeletons, it also damages the specimens owing to heating in the beam. In SEM and STEM cytoskeletons are stable and the resolution is adequate to resolve individual microfilaments. The best single method for visualizing cytoskeletons is inverted contrast STEM, which images both the metal-coated cytoskeletal structures and electron-dense material within the nucleus and cytoplasm as white against a dark background. STEM and TEM were both suitable for visualizing colloidal gold particles in immunolabeled samples.  相似文献   

5.
The paper shows the examples of application of transmission electron microscopy (TEM) techniques for characterization of two types of copper–cobalt magnetic nanomaterials: Cu-10 wt% Co granular giant magnetoresistance (GMR) thin ribbons and thin nanocrystalline Co films deposited on Cu substrate. Quantitative TEM microstructural analyses were used for determination of Co particle size distributions in GMR ribbons. It was demonstrated that the relative resistivity depends on the mean diameter of the cobalt nanoparticles. For nanocrystalline thin Co layers, off-axis electron holography was used to investigate their magnetic structure. The mean in-plane component of the magnetic field in cobalt was calculated from the phase gradient.  相似文献   

6.
Silicon cantilever probes with monolithically integrated tips are commercially available and are routinely used for atomic force microscopy (AFM). For such probes, amagnetic refinement of the silicon tip has been developed and results in a deposition of ferromagnetic material such as nickel or CrCoTa in the top area of the tip. The method consists of essentially three steps: (1) A broad-area sputter deposition of a ferromagnetic material; (2) a selective electron beam-induced carbon deposition at the top of the tip; (3) a broad-area ion-beam sputter etching, which removes the magnetic layer everywhere except underneath the carbon cap. The method allows to control the total amount and extension of the magnetic material left at the tip. It is applicable to all kinds of ferromagnetic materials which can be deposited as a thin layer by sputter deposition or evaporation. Experiments indicate that the method is reliable and improves the resolution of magnetic force microscopy (MFM). With such magnetically refined tips on silicon cantilevers, MFM measurements have been performed in contact mode as well as in dynamic and static noncontact modes. In this paper, the method for magnetic tip refinement is described and MFM measurements with these tips are presented.  相似文献   

7.
The interaction of sodium cholate (SC) with phosphatidylcholine liposomes was studied by means of transmission electron microscopy (TEM), changes in the mean particle size (quasielastic light scattering, QELS) and in the static light scattering (SLS) of the system during liposome solubilization. A good correlation was found between the TEM diameter of particles and the mean hydrodynamic diameter (HD) determined by QELS. The intermediate aggregates resulting in this interaction were dependent on the SC concentration in the system. Thus, an initial vesicle growth occurred when the SC concentration in the system was 13.79 mol%. Additional SC amounts (41.17 mol% SC) led to the formation of the largest vesicles (HD 410 nm). Increasing SC amounts led to a slight fall in the vesicle diameter and in the SLS of the system. Thus, for 47.08 mol% SC, TEM images still showed the presence of vesicles albeit with traces of smaller structures and signs of vesicle fusion. When SC concentration exceeded 48 mol% an abrupt decrease in SLS occurred, the size curve starting to show a bimodal distribution. Thus, for 50 mol% SC a sharp distribution curve appeared at 52 nm indicating the formation of small particles and TEM images showed clear signs of vesicle disintegration with formation of tubular structures. The subsequent self organization of these tubular structures (54 mol% SC) led to the formation of open multilayered structures in coexistence with small particles. A gradual increase in the number of these small particles (mixed micelles) led to the complete solubilization of liposomes.  相似文献   

8.
以纳米Fe3O4颗粒为核,分别采用液相沉积法和溶胶一凝胶法两种方法将MnO2包覆在其上制备了Fe3O4/MnO2磁性复合颗粒,并借助XRD、TEM、FTIR和VSM等手段分别对纳米Fe3O4颗粒和两种复合颗粒进行表征.结果表明:采用液相沉积法进行包覆可生成以多个纳米Fe3O4颗粒为核、粒径约为200 nm的近球形Fe3O4/MnO2磁性复合颗粒,其饱和磁化强度为24.4 kA·m-1;采用溶胶-凝胶法进行包覆则生成以单个纳米Fe3O4颗粒为核、粒径约为50 nm的磁性复合颗粒,包覆层为絮状MnO2,其饱和磁化强度为16.5 kA·m-1.  相似文献   

9.
Focused ion beam (FIB) techniques can prepare site‐specific transmission electron microscopy (TEM) cross‐section samples very quickly but they suffer from beam damage by the high energy Ga+ ion beam. An amorphous layer about 20–30 nm thick on each side of the TEM lamella and the supporting carbon film makes FIB‐prepared samples inferior to the traditional Ar+ thinned samples for some investigations such as high resolution transmission electron microscopy (HRTEM) and electron energy loss spectroscopy (EELS). We have developed techniques to combine broad argon ion milling with focused ion beam lift‐out methods to prepare high‐quality site‐specific TEM cross‐section samples. Site‐specific TEM cross‐sections were prepared by FIB and lifted out using a Narishige micromanipulator onto a half copper‐grid coated with carbon film. Pt deposition by FIB was used to bond the lamellae to the Cu grid, then the coating carbon film was removed and the sample on the bare Cu grid was polished by the usual broad beam Ar+ milling. By doing so, the thickness of the surface amorphous layers is reduced substantially and the sample quality for TEM observation is as good as the traditional Ar+ milled samples.  相似文献   

10.
Some examples are selected to demonstrate the variety of possible scanning probe microscopy application in industry. Magnetic and magneto-optical storage media can be investigated by magnetic force microscopy, whereas a conventional scanning force microscope is used to examine surface features of many different materials, such as technical glasses, photosensitive materials, new superconductors, and biomolecules. Some other examples include the modification as well as the observation of liquid crystal devices, and the impact that scanning probe microscopy has on other techniques such as high precision stepping motors and high quality electron beam sources.  相似文献   

11.
Three-dimensional confocal laser scanning microscopy (CLSM) was used as an essential investigation method to obtain information about the formation and morphological characteristics of nanocapsules. Nanocapsules are built by layer-by-layer deposition of alternatively charged polyelectrolytes on templates forming nanostructured hollow shells. CLSM is unique in allowing for monitoring of the core dissolution process in real time and for studying nanocapsule functioning in hydrated conditions within a three-dimensional and temporal framework. Since we are also interested in the identification of other possible templates, we briefly report on the use of yeast cells as biocolloidal cores monitored by means of two-photon microscopy. Here we focus our attention on the use of CdCO(3) crystals as template candidates for the preparation of stable capsules. Both cubic and spherical CdCO(3) cores have been produced. Cubic cores exhibit higher monodispersity and smaller size compared to spherical ones. Capsules templated on these cores have a higher surface-to-volume ratio that is valuable for applications related to drug delivery, functional properties of the shells and adsorption of proteins, and other biologically relevant molecules. Microsc. Res. Tech. 59:536-541, 2002.  相似文献   

12.
When electron microscopy (EM) was introduced in the 1930s it gave scientists their first look into the nanoworld of cells. Over the last 80 years EM has vastly increased our understanding of the complex cellular structures that underlie the diverse functions that cells need to maintain life. One drawback that has been difficult to overcome was the inherent lack of volume information, mainly due to the limit on the thickness of sections that could be viewed in a transmission electron microscope (TEM). For many years scientists struggled to achieve three‐dimensional (3D) EM using serial section reconstructions, TEM tomography, and scanning EM (SEM) techniques such as freeze‐fracture. Although each technique yielded some special information, they required a significant amount of time and specialist expertise to obtain even a very small 3D EM dataset. Almost 20 years ago scientists began to exploit SEMs to image blocks of embedded tissues and perform serial sectioning of these tissues inside the SEM chamber. Using first focused ion beams (FIB) and subsequently robotic ultramicrotomes (serial block‐face, SBF‐SEM) microscopists were able to collect large volumes of 3D EM information at resolutions that could address many important biological questions, and do so in an efficient manner. We present here some examples of 3D EM taken from the many diverse specimens that have been imaged in our core facility. We propose that the next major step forward will be to efficiently correlate functional information obtained using light microscopy (LM) with 3D EM datasets to more completely investigate the important links between cell structures and their functions.  相似文献   

13.
M. Anders  H. Fuchs 《Scanning》1993,15(5):275-281
Scanning force microscopy techniques were applied to investigate the surface of magnetic tapes and organic surfaces such as film forming and radiation-sensitive polymeric materials. The unique potential of the method to derive quantitative data, that is, surface roughness and asymmetry parameters, is demonstrated. Force-modulation experiments indicate that liquid/gas interfaces can be directly detected.  相似文献   

14.
Scanning electron microscopy (SEM) has produced a wealth of novel images that have significantly complemented our perception of biological structure and function, derived initially from transmission electron microscopy (TEM) information. SEM is a surface imaging technology, and its impact at the subcellular level has been restricted by reduced resolution in comparison with TEM. Recently, SEM resolution has been considerably improved by the advent of high-brightness sources used in field-emission instruments (FEISEM) which have produced resolution of around 1 nm, virtually equivalent to TEM “working resolution.” Here we review our findings in the use of FEISEM in the imaging of nuclear envelopes and their associated structures, such as nuclear pore complexes, and the relationships of structure and function. FEISEM allows the structurally orientated cell biologist to visualise, directly and in three dimensions, subcellular structure and its modulation with a view to understanding its functional significance.  相似文献   

15.
Preparing cellular structures for visualization by high-resolution scanning electron microscopy (SEM) is a multi-step process which includes fixation, dehydration, drying and metal coating. Drying and metal coating are limiting for high-resolution work. Commonly, the dried samples are exposed to the air before they are inserted into a metal coating apparatus, thereby exposing them to moisture and the accompanying risk of rehydration, which may cause changes in the supramolecular structure. We have modified a freeze-dryer to accommodate a magnetron sputtering head, in order to sputter-coat the frozen-dried samples while still in the drying chamber in the cold, a process we call cryosputtering. A layer of 1·5 nm of tungsten was cryosputtered onto whole mounts of cytoskeletons from detergent-extracted human glioma cells or fibroblasts and the specimens were examined by high-resolution SEM and transmission electron microscopy (TEM). To reduce the effects of backstreaming oil from the vacuum system, a turbomolecular pump backed by a two-stage rotary vane pump was connected to the drying-coating chamber. This pump system provides a high vacuum, making it possible to dry the specimens at — 90°C/183 K, thus reducing the risk for recrystallization of water. Furthermore, the high vacuum minimizes the negative effects of contaminants, which can be deposited onto the specimen surface and affect the quality of the metal coat formed during sputtering.  相似文献   

16.
A combination of scanning electron microscopy (SEM) and environmental scanning electron microscopy (ESEM) techniques, as well as atomic force microscopy (AFM) methods has been used to study fragments of the Martian meteorite ALH84001. Images of the same areas on the meteorite were obtained prior to and following gold/palladium coating by mapping the surface of the fragment using ESEM coupled with energy-dispersive X-ray analysis. Viewing of the fragments demonstrated the presence of structures, previously described as nanofossils by McKay et al . (Search for past life on Mars — possible relic biogenic activity in martian meteorite ALH84001. Science , 1996, pp. 924–930) of NASA who used SEM imaging of gold-coated meteorite samples. Careful imaging of the fragments revealed that the observed structures were not an artefact introduced by the coating procedure.  相似文献   

17.
Visualization of structural details of specimens in field emission scanning electron microscopy (FE-SEM) requires optimal conductivity. This paper reports on the differences in conductive layers of Au/Pd, Pt and Cr, with a thickness of 1.5–3.0 nm, deposited by planar magnetron sputtering devices. The coating units were used under standard conditions for source–substrate distance, current, HT and argon pressure. Carbon films, deposited by high-vacuum evaporation on small, freshly cleaved pieces of mica, were used as substrate and mounted on copper grids for TEM and SEM inspection. Au/Pd, Pt and, to a lesser extent, Cr coatings varied in particle density, size and shape. Au/Pd coatings have a slightly more granular appearance than Cr and Pt coatings, but this is strongly dependent on the type of sputtering device employed. In FE-SEM images there is almost no difference in contrast and particle size between the Au/Pd layer and the Pt layers of a similar thickness. The nuclei of Au/Pd are rather small with almost no growth to the sides or in height, making Au/Pd coatings a good alternative to chromium and platinum for FE-SEM of biological tissues because of its higher yield of secondary electrons.  相似文献   

18.
The presented article characterized microstructural aspects of thermal barrier coatings (TBCs) analysis using methods of electron microscopy such as electron backscatter diffraction (EBSD), transmission/scanning electron microscopy (S/TEM), and TEM. The analyzed TBC system is based on gadolinium zirconate deposited by air plasma spraying method, and additionally, it was subjected to an oxidation test for 500 hr at a temperature of 1,100°C. Moreover, the morphological characterization of feedstock powder was showed. EBSD analysis revealed the inhomogeneity of feedstock materials in the form of complex phase composition. In the case of deposited coating, this method was used to characterize the crystallite size of zirconate coating and phase composition of thermally grown oxide zone. S/TEM and TEM analysis showed morphological details of this zone but not revealed such phase as perovskite oxide of GdAlO3 type.  相似文献   

19.
Thin cross-sections of human hairs were investigated by scanning near-field optical microscopy (SNOM) and confocal laser scanning microscopy (CLSM) after penetration of a fluorescent dye. The same samples were measured with both techniques to compare the observed structures. The images obtained from the two methods show nearly identical structures representing pathways of the dye molecules in hairs. The SNOM images provide a higher resolution than the CLSM images. Therefore, SNOM is believed to be a suitable method for investigations at a resolution of 100 nm on penetration pathways of fluorescent dyes such as the cell membrane complex pathway in cross-sections of hairs.  相似文献   

20.
针对电火花沉积层存在的孔隙、微裂纹、表面组织疏松、连续性差及表面质量差等缺陷,提出了电火花沉积重熔碾轧修整加工方法。进行了所提方法与电火花沉积的对比试验,并对制备的沉积层进行了分析。结果表明:重熔碾轧修整时电极对沉积表面有较大的挤压碾轧作用,能有效消除沉积层内部孔隙、微裂纹、组织疏松等缺陷,细化沉积层晶粒结构,提高沉积层的连续性、完整性。电极对沉积层表面有显著的磨削涂覆作用,重熔碾轧修整表面粗糙度为电火花沉积表面粗糙度的76.3%,基本消除了表面孔洞、裂纹等缺陷,提高了沉积层表面质量。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号